897 resultados para Soft biometrics


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Certain areas of Iowa abound in loess, others contain soft limestones that are readily and cheaply available, and a large portion of the state is underlaid with sand. None of these materials is considered suitable in present practices for use in all-weather road construction. The loess is too fine and too difficult to handle; the limestones are considered too soft, and some of the harder ones unsound for this use; the sands are not naturally of the desired gradation and do not lend themselves to blending into satisfactory gradations. The purpose of this project is, therefore, to study and develop means and to determine the feasibility of using these materials, loess, fine sand, and soft limestones, either separately or in combinations in conjunction with liquid binders to produce paving mixtures applicable for all-weather road construction. Also included in the project was the development of methods of processing any of these materials, if necessary, to make them suitable for the desired purpose

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Interest in marine natural products has allowed the discovery of new drugs and trabectedin (ET-743, Yondelis), derived from the marine tunicate Ecteinascidia turbinata, was approved for clinical use in 2007. It binds to the DNA minor groove leading to interferences with the intracellular transcription pathways and DNA-repair proteins. In vitro antitumor activity was demonstrated against various cancer cell lines and soft tissue sarcoma cell lines. In phase I studies tumor responses were observed also in osteosarcomas and different soft tissue sarcoma subtypes. The most common toxicities were myelosuppression and transient elevation of liver function tests, which could be reduced by dexamethasone premedication. The efficacy of trabectedin was established in three phase II studies where it was administered at 1.5 mg/m2 as a 24 h intravenous infusion repeated every three weeks, in previously treated patients. The objective response rate was 3.7%-8.3% and the tumor control rate (which included complete response, partial response and stable disease) was obtained in half of patients for a median overall survival reaching 12 months. In nonpretreated patients the overall response rate was 17%. Twenty-four percent of patients were without progression at six months. The median overall survival was almost 16 months with 72% surviving at one year. Predictive factors of response are being explored to identify patients who are most likely to respond to trabectedin. Combination with other agents are currently studied with promising results. In summary trabectedin is an active new chemotherapeutic agents that has demonstrated its role in the armamentarium of treatments for patients with sarcomas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Accurate measurement of knee kinematics during functional activities suffers mainly from soft tissue artifact (STA): the combination of local surface deformations and rigid movement of markers relative to the underlying bone (also called rigid STA movement: RSTAM). This study proposes to assess RSTAM on the thigh, shank, and knee joint and to observe possible features between subjects. Nineteen subjects with knee arthroplasty were asked to walk on a treadmill while a biplane fluoroscopic system (X-rays) and a stereophotogrammetric system (skin markers) recorded their knee movement. The RSTAM was defined as the rigid movement of the cluster of skin markers relative to the prosthesis. The results showed that RSTAM amplitude represents approximately 80-100% of the STA. The vertical axis of the anatomical frame of the femur was influenced the most by RSTAM. Combined with tibial error, internal/external rotation angle and distraction-compression were the knee kinematics parameters most affected by RSTAM during the gait cycle, with average rms values of 3.8° and 11.1 mm. This study highlighted higher RSTAM during the swing phase particularly in the thigh segment and suggests new features for RSTAM such as the particular shape of some RSTAM waveforms and the absence of RSTAM in certain kinematics during the gait phases. The comparison of coefficient of multiple correlations showed some similarities of RSTAM between subjects, while some correlations were found with gait speed and BMI. These new insights could potentially allow the development of new methods of compensation to avoid STA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Low energy x-ray fluorescence (LEXRF) detection was optimized for imaging cerebral glucose metabolism by mapping the fluorine LEXRF signal of 19 F in 19 FDG, trapped as intracellular 19 F-deoxyglucose-6-phosphate ( 19 FDG-6P) at 1μm spatial resolution from 3μm thick brain slices. 19 FDG metabolism was evaluated in brain structures closely resembling the general cerebral cytoarchitecture following formalin fixation of brain slices and their inclusion in an epon matrix. 2-dimensional distribution maps of 19 FDG-6P were placed in a cytoarchitectural and morphological context by simultaneous LEXRF mapping of N and O, and scanning transmission x-ray (STXM) imaging. A disproportionately high uptake and metabolism of glucose was found in neuropil relative to intracellular domains of the cell body of hypothalamic neurons, showing directly that neurons, like glial cells, also metabolize glucose. As 19 F-deoxyglucose-6P is structurally identical to 18 F-deoxyglucose-6P, LEXRF of subcellular 19 F provides a link to in vivo 18 FDG PET, forming a novel basis for understanding the physiological mechanisms underlying the 18 FDG PET image, and the contribution of neurons and glia to the PET signal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

European regulatory networks (ERNs) are in charge of producing and disseminating non-bindings standards, guidelines and recommendations in a number of important domains, such as banking and finance, electricity and gas, telecommunications, and competition regulation. The goal of these soft rules is to promote 'best practices', achieve co-ordination among regulatory authorities and ensure the consistent application of harmonized pro-competition rules across Europe. This contribution examines the domestic adoption of the soft rules developed within the four main ERNs. Different factors are expected to influence the process of domestic adoption: the resources of regulators; the existence of a review panel; and the interdependence of the issues at stake. The empirical analysis supports hypotheses about the relevance of network-level factors: monitoring and public reporting procedures increase the final level of adoption, while soft rules concerning highly interdependent policy areas are adopted earlier.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Epithelioid neoplasms are generally carcinomas. As confirmation that every rule is meant to be broken, some sarcomas demonstrate epithelioid morphology, and can even express cytokeratins. These sarcomas have unique behavior, for example, a much higher rate of lymph node metastasis than other sarcomas. This group of sarcomas also presents diagnostic and therapeutic challenges to those clinicians who help patients contend with these difficult tumors. In this review, some of the major categories of epithelioid soft tissue tumors are described, with clinical data reported as available. Some of these tumors provide excellent opportunities to examine newer protein-targeted agents in investigational settings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L'expérience Belle, située dans le centre de recherche du KEK, au Japon, est consacrée principalement à l'étude de la violation de CP dans le système des mésons B. Elle est placée sur le collisionneur KEKB, qui produit des paires Banti-B. KEKB, l'une des deux « usines à B » actuellement en fonction, détient le record du nombre d'événements produits avec plus de 150 millions de paires. Cet échantillon permet des mesures d'une grande précision dans le domaine de la physique du méson B. C'est dans le cadre de ces mesures de précision que s'inscrit cette analyse. L'un des phénomènes remarquables de la physique des hautes énergies est la faculté qu'a l'interaction faible de coupler un méson neutre avec son anti-méson. Dans le présent travail, nous nous intéressons au méson B neutre couplé à l'anti-méson B neutre, avec une fréquence d'oscillation _md mesurable précisément. Outre la beauté de ce phénomène lui-même, une telle mesure trouve sa place dans la quête de l'origine de la violation de CP. Cette dernière n'est incluse que d'une façon peu satisfaisante dans le modèle standard des interactions électro-faibles. C'est donc la recherche de phénomènes physiques encore inexpliqués qui motive en premier lieu la collaboration Belle. Il existe déjà de nombreuses mesures de _md antérieures. Celle que nous présentons ici est cependant d'une précision encore jamais atteinte grâce, d'une part, à l'excellente performance de KEKB et, d'autre part, à une approche originale qui permet de réduire considérablement la contamination de la mesure par des événements indésirés. Cette approche fut déjà mise à profit par d'autres expériences, dans des conditions quelque peu différentes de celles de Belle. La méthode utilisée consiste à reconstruire partiellement l'un des mésons dans le canal ___D*(D0_)l_l, en n'utilisant que les informations relatives au lepton l et au pion _. L'information concernant l'autre méson de la paire Banti-B initiale n'est tirée que d'un seul lepton de haute énergie. Ainsi, l'échantillon à disposition ne souffre pas de grandes réductions dues à une reconstruction complète, tandis que la contamination due aux mésons B chargés, produits par KEKB en quantité égale aux B0, est fortement diminuée en comparaison d'une analyse inclusive. Nous obtenons finalement le résultat suivant : _md = 0.513±0.006±0.008 ps^-1, la première erreur étant l'erreur statistique et la deuxième, l'erreur systématique.<br/><br/>The Belle experiment is located in the KEK research centre (Japan) and is primarily devoted to the study of CP violation in the B meson sector. Belle is placed on the KEKB collider, one of the two currently running "B-meson factories", which produce Banti-B pairs. KEKB has created more than 150 million pairs in total, a world record for this kind of colliders. This large sample allows very precise measurements in the physics of beauty mesons. The present analysis falls within the framework of these precise measurements. One of the most remarkable phenomena in high-energy physics is the ability of weak interactions to couple a neutral meson to its anti-meson. In this work, we study the coupling of neutral B with neutral anti-B meson, which induces an oscillation of frequency _md we can measure accurately. Besides the interest of this phenomenon itself, this measurement plays an important role in the quest for the origin of CP violation. The standard model of electro-weak interactions does not include CP violation in a fully satisfactory way. The search for yet unexplained physical phenomena is, therefore, the main motivation of the Belle collaboration. Many measurements of _md have previously been performed. The present work, however, leads to a precision on _md that was never reached before. This is the result of the excellent performance of KEKB, and of an original approach that allows to considerably reduce background contamination of pertinent events. This approach was already successfully used by other collaborations, in slightly different conditions as here. The method we employed consists in the partial reconstruction of one of the B mesons through the decay channel ___D*(D0_)l_l, where only the information on the lepton l and the pion _ are used. The information on the other B meson of the initial Banti-B pair is extracted from a single high-energy lepton. The available sample of Banti-B pairs thus does not suffer from large reductions due to complete reconstruction, nor does it suffer of high charged B meson background, as in inclusive analyses. We finally obtain the following result: _md = 0.513±0.006±0.008 ps^-1, where the first error is statistical, and the second, systematical.<br/><br/>De quoi la matière est-elle constituée ? Comment tient-elle ensemble ? Ce sont là les questions auxquelles la recherche en physique des hautes énergies tente de répondre. Cette recherche est conduite à deux niveaux en constante interaction. D?une part, des modèles théoriques sont élaborés pour tenter de comprendre et de décrire les observations. Ces dernières, d?autre part, sont réalisées au moyen de collisions à haute énergie de particules élémentaires. C?est ainsi que l?on a pu mettre en évidence l?existence de quatre forces fondamentales et de 24 constituants élémentaires, classés en « quarks » et « leptons ». Il s?agit là de l?une des plus belles réussites du modèle en usage aujourd?hui, appelé « Modèle Standard ». Il est une observation fondamentale que le Modèle Standard peine cependant à expliquer, c?est la disparition quasi complète de l?anti-matière (le « négatif » de la matière). Au niveau fondamental, cela doit correspondre à une asymétrie entre particules (constituants de la matière) et antiparticules (constituants de l?anti-matière). On l?appelle l?asymétrie (ou violation) CP. Bien qu?incluse dans le Modèle Standard, cette asymétrie n?est que partiellement prise en compte, semble-t-il. En outre, son origine est inconnue. D?intenses recherches sont donc aujourd?hui entreprises pour mettre en lumière cette asymétrie. L?expérience Belle, au Japon, en est une des pionnières. Belle étudie en effet les phénomènes physiques liés à une famille de particules appelées les « mésons B », dont on sait qu?elles sont liées de près à l?asymétrie CP. C?est dans le cadre de cette recherche que se place cette thèse. Nous avons étudié une propriété remarquable du méson B neutre : l?oscillation de ce méson avec son anti-méson. Cette particule est de se désintégrer pour donner l?antiparticule associée. Il est clair que cette oscillation est rattachée à l?asymétrie CP. Nous avons ici déterminé avec une précision encore inégalée la fréquence de cette oscillation. La méthode utilisée consiste à caractériser une paire de mésons B à l?aide de leur désintégration comprenant un lepton chacun. Une plus grande précision est obtenue en recherchant également une particule appelée le pion, et qui provient de la désintégration d?un des mésons. Outre l?intérêt de ce phénomène oscillatoire en lui-même, cette mesure permet d?affiner, directement ou indirectement, le Modèle Standard. Elle pourra aussi, à terme, aider à élucider le mystère de l?asymétrie entre matière et anti-matière.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quartz tuning forks are extremely good resonators and their use is growing in scanning probe microscopy. Nevertheless, only a few studies on soft biological samples have been reported using these probes. In this work, we present the methodology to develop and use these nanosensors to properly work with biological samples. The working principles, fabrication and experimental setup are presented. The results in the nanocharacterization of different samples in different ambients are presented by using different working modes: amplitude modulation with and without the use of a Phase-Locked Loop (PLL) and frequency modulation. Pseudomonas aeruginosa bacteria are imaged in nitrogen using amplitude modulation. Microcontact printed antibodies are imaged in buffer using amplitude modulation with a PLL. Finally, metastatic cells are imaged in air using frequency modulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In metallurgic plants a high quality metal production is always required. Nowadays soft computing applications are more often used for automation of manufacturing process and quality control instead of mechanical techniques. In this thesis an overview of soft computing methods presents. As an example of soft computing application, an effective model of fuzzy expert system for the automotive quality control of steel degassing process was developed. The purpose of this work is to describe the fuzzy relations as quality hypersurfaces by varying number of linguistic variables and fuzzy sets.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The aim of this in vitro experimental study was to perform histological evaluation of the thermal effect produced on soft tissue irradiated with CO2, Er,Cr:YSGG or diode lasers. Study design: Porcine oral mucosa samples were irradiated with Er,Cr:YSGG laser at 1 W with and without water / air spray, at 2 W with and without water / air spray, and at 4 W with water / air spray, with CO2 laser at 1 W, 2 W, 10 W, 20 W continuous mode and 20 W pulsed mode and diode laser at 2W, 5W, and 10W pulsed mode. The thermal effect was evaluated measuring the width of damaged tissue adjacent to the incision, stained positively for hyalinized tissue with Hematoxylin-Eosin and Masson Trichrome stains. Besides, histological changes in the irradiated tissue were described using subjective grading scales. Results: The evaluated lasers developed a wide range of thermal damage with significant differences between groups. The samples with lowest thermal effect were those irradiated with Er,Cr:YSGG laser using water / air spray, followed by CO2 and diode lasers. Conclusions: Emission parameters of each laser system may influence the thermal damage inflicted on the soft tissue, however, the wave length of each laser determines the absorption rate characteristics of every tissue and the thermal effect

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Segment poses and joint kinematics estimated from skin markers are highly affected by soft tissue artifact (STA) and its rigid motion component (STARM). While four marker-clusters could decrease the STA non-rigid motion during gait activity, other data, such as marker location or STARM patterns, would be crucial to compensate for STA in clinical gait analysis. The present study proposed 1) to devise a comprehensive average map illustrating the spatial distribution of STA for the lower limb during treadmill gait and 2) to analyze STARM from four marker-clusters assigned to areas extracted from spatial distribution. All experiments were realized using a stereophotogrammetric system to track the skin markers and a bi-plane fluoroscopic system to track the knee prosthesis. Computation of the spatial distribution of STA was realized on 19 subjects using 80 markers apposed on the lower limb. Three different areas were extracted from the distribution map of the thigh. The marker displacement reached a maximum of 24.9mm and 15.3mm in the proximal areas of thigh and shank, respectively. STARM was larger on thigh than the shank with RMS error in cluster orientations between 1.2° and 8.1°. The translation RMS errors were also large (3.0mm to 16.2mm). No marker-cluster correctly compensated for STARM. However, the coefficient of multiple correlations exhibited excellent scores between skin and bone kinematics, as well as for STARM between subjects. These correlations highlight dependencies between STARM and the kinematic components. This study provides new insights for modeling STARM for gait activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Molecular dynamics simulations were performed to study the ion and water distribution around a spherical charged nanoparticle. A soft nanoparticle model was designed using a set of hydrophobic interaction sites distributed in six concentric spherical layers. In order to simulate the effect of charged functionalyzed groups on the nanoparticle surface, a set of charged sites were distributed in the outer layer. Four charged nanoparticle models, from a surface charge value of −0.035 Cm−2 to − 0.28 Cm−2, were studied in NaCl and CaCl2 salt solutions at 1 M and 0.1 M concentrations to evaluate the effect of the surface charge, counterion valence, and concentration of added salt. We obtain that Na + and Ca2 + ions enter inside the soft nanoparticle. Monovalent ions are more accumulated inside the nanoparticle surface, whereas divalent ions are more accumulated just in the plane of the nanoparticle surface sites. The increasing of the the salt concentration has little effect on the internalization of counterions, but significantly reduces the number of water molecules that enter inside the nanoparticle. The manner of distributing the surface charge in the nanoparticle (uniformly over all surface sites or discretely over a limited set of randomly selected sites) considerably affects the distribution of counterions in the proximities of the nanoparticle surface.