988 resultados para Sixty-minute isotherm


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to rapid and continuous deforestation, recent bird surveys in the Atlantic Forest are following rapid assessment programs to accumulate significant amounts of data during short periods of time. During this study, two surveying methods were used to evaluate which technique rapidly accumulated most species (> 90% of the estimated empirical value) at lowland Atlantic Forests in the state of São Paulo, southeastern Brazil. Birds were counted during the 2008-2010 breeding seasons using 10-minute point counts and 10-species lists. Overall, point counting detected as many species as lists (79 vs. 83, respectively), and 88 points (14.7 h) detected 90% of the estimated species richness. Forty-one lists were insufficient to detect 90% of all species. However, lists accumulated species faster in a shorter time period, probably due to the nature of the point count method in which species detected while moving between points are not considered. Rapid assessment programs in these forests will rapidly detect more species using 10-species lists. Both methods shared 63% of all forest species, but this may be due to spatial and temporal mismatch between samplings of each method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: To evaluate the outcomes of short (15 minutes) oral hygiene vs. hand hygiene education for preschool children 4 weeks after these interventions. MATERIALS AND METHODS: Sixty-one preschool children (age range 4-6 years) attending four kindergarten classes participated in a 15-minute health education programme on the importance of body cleanliness for general health. In addition, specific instructions on oral hygiene were provided for two randomly selected classes (30 children), while the remaining two classes (31 children) were given instruction of hand and nail cleaning. The oral hygiene status was assessed usingthe plaque control record (PCR). The cleanliness of the hands and fingernails was determined using a hand hygiene index (HHI) and a nail hygiene index (NHI). All three parameters were assessed before the intervention as well as 4 weeks thereafter. RESULTS: Four weeks after education, the PCR had improved for all children from 79.95% to 72.35% (p < 0.001). The NHI had improved from 74.91% to 61.71% (p < 0.001). In addition, the mean PCR of the children given oral hygiene instruction decreased from 83.67% to 72.40%, while the mean PCR of the children given hand and nail cleaning instruction decreased from 76.23% to 72.29% (interaction effect 'time x type of instruction': p = 0.044). Girls' PCR improved significantly more than boys' PCR (Girls, 80.98 vs. 69.71; boys, 78.33 vs. 75.31; p = 0.021). CONCLUSIONS: The results of the study show that even a short, school-based educational intervention at an early age may affect children's oral health promotion significantly. Teachers should, therefore, be encouraged to educate children from an early age about oral hygiene promotion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To quantify the interobserver variability of abdominal aortic aneurysm (AAA) neck length and angulation measurements. MATERIALS AND METHODS: A total of 25 consecutive patients scheduled for endovascular AAA repair underwent follow-up 64-row computed tomographic (CT) angiography in 0.625-mm collimation. AAA neck length and angulation were determined by four blinded, independent readers. AAA neck length was defined as the longitudinal distance between the first transverse CT slice directly distal to the lowermost renal artery and the first transverse CT slice that showed at least a 15% larger outer aortic wall diameter versus the diameter measured directly below the lowermost renal artery. Infrarenal AAA neck angulation was defined as the true angle between the longitudinal axis of the proximal AAA neck and the longitudinal axis of the AAA lumen as analyzed on three-dimensional CT reconstructions. RESULTS: Mean deviation in aortic neck length determination was 32.3% and that in aortic neck angulation was 32.1%. Interobserver variability of aortic neck length and angulation measurements was considerable: in any reader combination, at least one measurement difference was outside the predefined limits of agreement. CONCLUSIONS: Assessment of the longitudinal extension and angulation of the infrarenal aortic neck is associated with substantial observer variability, even if measurement is carried out according to a standardized protocol. Further studies are mandatory to assess dedicated technical approaches to minimize variance in the determination of the longitudinal extension and angulation of the infrarenal aortic neck.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This dissertation established a standard foam index: the absolute foam index test. This test characterized a wide range of coal fly ash by the absolute volume of air-entraining admixture (AEA) necessary to produce a 15-second metastable foam in a coal fly ash-cement slurry in a specified time. The absolute foam index test was used to characterize fly ash samples having loss on ignition (LOI) values that ranged from 0.17 to 23.3 %wt. The absolute foam index characterized the fly ash samples by absolute volume of AEA, defined as the amount of undiluted AEA solution added to obtain a 15-minute endpoint signified by 15-second metastable foam. Results were compared from several foam index test time trials that used different initial test concentrations to reach termination at selected times. Based on the coefficient of variation (CV), a 15-minute endpoint, with limits of 12 to 18 minutes was chosen. Various initial test concentrations were used to accomplish consistent contact times and concentration gradients for the 15-minute test endpoint for the fly ash samples. A set of four standard concentrations for the absolute foam index test were defined by regression analyses and a procedure simplifying the test process. The set of standard concentrations for the absolute foam index test was determined by analyzing experimental results of 80 tests on coal fly ashes with loss on ignition (LOI) values ranging from 0.39 to 23.3 wt.%. A regression analysis informed selection of four concentrations (2, 6, 10, and 15 vol.% AEA) that are expected to accommodate fly ashes with 0.39 to 23.3 wt.% LOI, depending on the AEA type. Higher concentrations should be used for high-LOI fly ash when necessary. A procedure developed using these standard concentrations is expected to require only 1-3 trials to meet specified endpoint criteria for most fly ashes. The AEA solution concentration that achieved the metastable foam in the foam index test was compared to the AEA equilibrium concentration obtained from the direct adsorption isotherm test with the same fly ash. The results showed that the AEA concentration that satisfied the absolute foam index test was much less than the equilibrium concentration. This indicated that the absolute foam index test was not at or near equilibrium. Rather, it was a dynamic test where the time of the test played an important role in the results. Even though the absolute foam index was not an equilibrium condition, a correlation was made between the absolute foam index and adsorption isotherms. Equilibrium isotherm equations obtained from direct isotherm tests were used to calculate the equilibrium concentrations and capacities of fly ash from 0.17 to 10.5% LOI. The results showed that the calculated fly ash capacity was much less than capacities obtained from isotherm tests that were conducted with higher initial concentrations. This indicated that the absolute foam index was not equilibrium. Rather, the test is dynamic where the time of the test played an important role in the results. Even though the absolute foam index was not an equilibrium condition, a correlation was made between the absolute foam index and adsorption isotherms for fly ash of 0.17 to 10.5% LOI. Several batches of mortars were mixed for the same fly ash type increasing only the AEA concentration (dosage) in each subsequent batch. Mortar air test results for each batch showed for each increase in AEA concentration, air contents increased until a point where the next increase in AEA concentration resulted in no increase in air content. This was maximum air content that could be achieved by the particular mortar system; the system reached its air capacity at the saturation limit. This concentration of AEA was compared to the critical micelle concentration (CMC) for the AEA and the absolute foam index.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To compare tunnelled scleral intravitreal injection with straight scleral intravitreal injection concerning short-term intraocular pressure (IOP) changes, occurrence and amount of vitreous reflux, and patient discomfort. METHODS: Sixty patients were randomly allocated to two groups (tunnelled intravitreal injection and straight intravitreal injection). IOP was measured before and directly (<1 minute) after the injection of 0.05 mL of an antivascular endothelial growth factor agent and then every 5 minutes until IOP was <30 mmHg. Occurrence and amount of vitreous reflux were recorded. Patient discomfort during injection was assessed with a Wong-Baker faces pain rating scale. RESULTS: IOP (mmHg +/- SD) increased significantly directly after injection to 35.97 +/- 8.13 (tunnelled intravitreal injection) and 30.19 +/- 12.14 (straight intravitreal injection). These pressure spikes differed significantly between both groups (P = 0.01, mean difference: -7.11). Five minutes after injection, there was no significant difference in IOP increase between the groups. All IOP measurements were <30 mmHg after 15 minutes. Occurrence and amount of vitreous reflux were significantly higher with straight intravitreal injection. There was no significant difference in Wong-Baker faces pain rating scale score between both groups. CONCLUSION: Tunnelled intravitreal injection seems to be the technique of choice for low-volume intravitreal injection (0.05 mL). There is neither a difference in patient discomfort nor a difference in IOP increase 5 minutes after injection between both groups. Significantly less vitreous reflux with tunnelled intravitreal injection should lead to less postinjectional drug loss.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The discovery and characterization of oncofetal proteins have led to significant advances in early cancer diagnosis and therapeutic monitoring of patients undergoing cancer chemotherapy. These tumor-associated antigens are presently measured by sensitive, specific immunoassay techniques based on the detection of minute amounts of labeled antigen or antibody incorporated into immune complexes, which must be isolated from free antigen and antibody.^ Since there are several disadvantages with using radioisotopes, the most common immunolabel, one major objective was to prepare covalently coupled enzyme-antibody conjugates and evaluate their use as a practical alternative to radiolabeled immune reagents. An improved technique for the production of enzyme-antibody conjugates was developed that involves oxidizing the carbohydrate moieties on a glycoprotein enzyme, then introducing antibody in the presence of polyethylene glycol (PEG). Covalent enzyme-antibody conjugates involving alkaline phosphatase and amyloglucosidase were produced and characterized.^ In order to increase the sensitivity of detecting the amyloglucosidase-antibody conjugate, an enzyme cycling assay was developed that measures glucose, the product of maltose cleavage by amyloglucosidase, in the picomole range. The increased sensitivity obtained by combined usage of the amyloglucosidase-antibody conjugate and enzyme cycling assay was then compared to that of conventional enzyme immunoassay (EIA).^ For immune complex isolation, polystyrene tubes and protein A-bearing Staphylococcus aureus were evaluated as solid phase matrices, upon which antibodies can be immobilized. A sandwich-type EIA, using antibody-coated S. aureus, was developed that measures human albumin (HSA) in the nanogram range. The assay, using an alkaline phosphatase-anti-HSA conjugate, was applied to the determination of HSA in human urine and evaluated extensively for its clinical applicability.^ Finally, in view of the clinical significance of alpha-fetoprotein (AFP) as an oncofetal antigen and the difficulty with its purification for use as an immunogen and assay standard, a chemical purification protocol was developed that resulted in a high yield of immunochemically pure AFP. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: In clinical practise the high dose ACTH stimulation test (HDT) is frequently used in the assessment of adrenal insufficiency (AI). However, there is uncertainty regarding optimal time-points and number of blood samplings. The present study compared the utility of a single cortisol value taken either 30 or 60 minutes after ACTH stimulation with the traditional interpretation of the HDT. METHODS: Retrospective analysis of 73 HDT performed at a single tertiary endocrine centre. Serum cortisol was measured at baseline, 30 and 60 minutes after intravenous administration of 250 µg synthetic ACTH1-24. Adrenal insufficiency (AI) was defined as a stimulated cortisol level <550 nmol/l. RESULTS: There were twenty patients (27.4%) who showed an insufficient rise in serum cortisol using traditional HDT criteria and were diagnosed to suffer from AI. There were ten individuals who showed insufficient cortisol values after 30 minutes, rising to sufficient levels at 60 minutes. All patients revealing an insufficient cortisol response result after 60 minutes also had an insufficient result after 30 minutes. The cortisol value taken after 30 minutes did not add incremental diagnostic value in any of the cases under investigation compared with the 60 minutes' sample. CONCLUSIONS: Based on the findings of the present analysis the utility of a cortisol measurement 30 minutes after high dose ACTH injection was low and did not add incremental diagnostic value to a single measurement after 60 minutes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Several studies show yoga may benefit chronic pain management. We investigated the effect of a single yoga session on the perception of pain, measured by a standardized pain provocation test in healthy yoga participants while also comparing pain perception to participants' own expectations. MATERIALS AND METHODS Ninety yoga participants were recruited at hatha yoga schools in Switzerland. Pain perception was measured with a standardized algometric pain provocation test; i.e., a calibrated peg was applied for 10 seconds after which the participant rated pain intensity on a 0-10 numerical rating scale. The test was applied to the middle finger, ear lobe, and second toe before and after a 60-minute yoga session. RESULTS Sixty out of 90 (66.7%) yoga participants expected a reduced pain perception after the yoga session. However, 36 (40%) participants actually experienced less pain after compared to before the yoga session. But overall, pain perception statistically did not significantly change from before to after the yoga session at any of the three body locations assessed. The expectations and also the previous yoga experience did not significantly influence the participants' pain perception. CONCLUSIONS Regardless of the high positive expectations on the influence of yoga on pain, a single yoga session does not significantly influence pain perception induced by a pain provocation test. Hypoalgesic effects of yoga should be explained otherwise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RATIONALE The use of 6-minute-walk distance (6MWD) as an indicator of exercise capacity to predict postoperative survival in lung transplantation has not previously been well studied. OBJECTIVES To evaluate the association between 6MWD and postoperative survival following lung transplantation. METHODS Adult, first time, lung-only transplantations per the United Network for Organ Sharing database from May 2005 to December 2011 were analyzed. Kaplan-Meier methods and Cox proportional hazards modeling were used to determine the association between preoperative 6MWD and post-transplant survival after adjusting for potential confounders. A receiver operating characteristic curve was used to determine the 6MWD value that provided maximal separation in 1-year mortality. A subanalysis was performed to assess the association between 6MWD and post-transplant survival by disease category. MEASUREMENTS AND MAIN RESULTS A total of 9,526 patients were included for analysis. The median 6MWD was 787 ft (25th-75th percentiles = 450-1,082 ft). Increasing 6MWD was associated with significantly lower overall hazard of death (P < 0.001). Continuous increase in walk distance through 1,200-1,400 ft conferred an incremental survival advantage. Although 6MWD strongly correlated with survival, the impact of a single dichotomous value to predict outcomes was limited. All disease categories demonstrated significantly longer survival with increasing 6MWD (P ≤ 0.009) except pulmonary vascular disease (P = 0.74); however, the low volume in this category (n = 312; 3.3%) may limit the ability to detect an association. CONCLUSIONS 6MWD is significantly associated with post-transplant survival and is best incorporated into transplant evaluations on a continuous basis given limited ability of a single, dichotomous value to predict outcomes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In Fraktur

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In Fraktur