958 resultados para Six-min walk test
Resumo:
Background and objective: Field exercise tests have been increasingly used for pulmonary risk assessment. The 6-min walking distance (6MWD) is a field test commonly employed in clinical practice; however, there is limited evidence supporting its use as a risk assessment method in abdominal surgery. The aim was to assess if the 6MWD can predict the development of post-operative pulmonary complications (PPCs) in patients having upper abdominal surgery (UAS). Methods: This prospective cohort study included 137 consecutive subjects undergoing elective UAS. Subjects performed the 6MWD on the day prior to surgery, and their performance were compared with predicted values of 6MWD (p6MWD) using a previously validated formula. PPCs (including pneumonia, tracheobronchitis, atelectasis with clinical repercussions, bronchospasm and acute respiratory failure) were assessed daily by a pulmonologist blinded to the 6MWD results. 6MWD and p6MWD were compared between subjects who developed PPC (PPC group) and those who did not (no PPC group) using Student's t-test. Results: Ten subjects experienced PPC (7.2%) and no significant difference was observed between the 6MWD obtained in the PPC group and no PPC group (466.0 +/- 97.0 m vs 485.3 +/- 107.1 m; P = 0.57, respectively). There was also no significant difference observed between groups for the p6MWD (100.7 +/- 29.1% vs 90.6 -/+ 20.9%; P > 0.05). Conclusions: The results of the present study suggest that the 6-min walking test is not a useful tool to identify subjects with increased risk of developing PPC following UAS.
Resumo:
BACKGROUND: Although lung clearance index (LCI) is a sensitive indicator of mild cystic fibrosis (CF) lung disease, it is rarely measured due to lengthy protocols and the commercial unavailability of multiple-breath washout (MBW) setups and tracer gases. We used a newly validated, commercially available nitrogen (N(2) ) MBW setup to assess success rate, duration, and variability of LCI within a 20 min timeframe, during clinical routine. We also evaluated the relationship between LCI and other clinical markers of CF lung disease. METHODS: One hundred thirty six children (83 with CF) between 4 and 16 years were studied in a pediatric CF outpatient setting. One hundred eighteen out of 136 children were naïve to MBW. Within 20 min, each child was trained, N(2) MBW was performed, and LCI was analyzed. We assessed intra- and between-test reproducibility in a subgroup of children. RESULTS: At least one LCI was feasible in 123 (90%) children, with a mean (range) of 3.3 (1.2-6.4) min per test. Two or more measurements were feasible in 56 (41%) children. Comparing LCI in CF versus controls, LCI mean (SD) was 12.0 (3.9) versus 6.1 (0.9), and the intra- and inter-test coefficient of repeatability was 1.00 versus 0.81 and 0.96 versus 0.62, respectively. LCI was correlated with spirometry, blood gases, and Pseudomonas aeruginosa infection. CONCLUSIONS: Using available N(2) MBW equipment, LCI measurements are practical and fast in children. LCI is correlated with markers of CF lung disease. Longer timeframes would be required for triplicate N(2) MBW tests in inexperienced children. Pediatr Pulmonol. © 2012 Wiley Periodicals, Inc.
Resumo:
Therapy has improved the survival of heart failure (HF) patients. However, many patients progress to advanced chronic HF (ACHF). We propose a practical clinical definition and describe the characteristics of this condition. Patients that are generally recognised as ACHF often exhibit the following characteristics: 1) severe symptoms (NYHA class III to IV); 2) episodes with clinical signs of fluid retention and/or peripheral hypoperfusion; 3) objective evidence of severe cardiac dysfunction, shown by at least one of the following: left ventricular ejection fraction<30%, pseudonormal or restrictive mitral inflow pattern at Doppler-echocardiography; high left and/or right ventricular filling pressures; elevated B-type natriuretic peptides; 4) severe impairment of functional capacity demonstrated by either inability to exercise, a 6-minute walk test distance<300 m or a peak oxygen uptake<12-14 ml/kg/min; 5) history of >1 HF hospitalisation in the past 6 months; 6) presence of all the previous features despite optimal therapy. This definition identifies a group of patients with compromised quality of life, poor prognosis, and a high risk of clinical events. These patients deserve effective therapeutic options and should be potential targets for future clinical research initiatives.
Resumo:
Introdução A poluição do ar é um fator de risco associado com descompensação e mortalidade em pacientes com insuficiência cardíaca (IC). Objetivo Avaliar o impacto de um filtro de polipropileno sobre desfechos cardiovasculares em pacientes com IC e voluntários saudáveis durante exposição controlada à poluição. Métodos Ensaio clínico duplocego, controlado e cruzado, incluindo 26 pacientes com IC e 15 voluntários saudáveis, expostos a três protocolos diferentes de inalação randomizados por ordem: Ar Limpo; Exposição à Partículas de Exaustão do Diesel (ED); e ED filtrada. Os desfechos estudados foram função endotelial por índice de hiperemia reativa (RHi) e índice de aumento (Aix), biomarcadores séricos, variáveis de teste cardiopulmonar submáximo (caminhada de seis-minutos [tc6m]; consumo de oxigênio [VO2]; equivalente ventilatório de gás carbônico [VE/VCO2 slope]; consumo de O2 por batida [PulsoO2]) e variabilidade da frequência cardíaca (VFC). Resultados No grupo IC, a ED piorou o RHi [de 2,17 (IQR: 1,8-2,5) para 1,72 (IQR: 1,5-2,2); p=0,002], reduziu o VO2 [de 11.0 ± 3.9 para 8.4±2.8ml/Kg/min; p < 0.001], o tc6m [de 243,3±13 para 220,8 ± 14m; p=0,030] e o PulsoO2 [de 8.9 ± 1.0 para 7.8±0.7ml/bpm; p < 0.001]; e aumentou o BNP [de 47,0pg/ml (IQR: 17,3-118,0) para 66,5pg/ml (IQR: 26,5-155,5); p=0,004]. O filtro foi capaz de reduzir a concentração de poluição de 325±31 para 25±6?g/m3 (p < 0,001 vs. ED). No grupo IC, o filtro foi associado com melhora no RHi [2,06 (IQR: 1,5-2,6); p=0,019 vs. ED); aumento no VO2 (10.4 ± 3.8ml/Kg/min; p < 0.001 vs. ED) e PulsoO2 (9.7±1.1ml/bpm; p < 0.001 vs. ED); e redução no BNP [44,0pg/ml (IQR: 20,0-110,0); p=0,015 vs. ED]. Em ambos os grupos, a ED reduziu o Aix, sem efeito do filtro. O uso do filtro foi associado com maior ventilação e reinalação de CO2. Outras variáveis pesquisadas como VE/VCO2 slope e VFC não sofreram influências entre os protocolos. Conclusão A poluição do ar afetou adversamente o desempenho cardiovascular de pacientes com IC. Este é o primeiro ensaio clínico demonstrando que um simples filtrorespiratório pode prevenir a disfunção endotelial, a intolerância ao exercício e o aumento do BNP associados à poluição em pacientes com IC. O uso de máscaras com filtro tem o potencial de reduzir a morbidade associada à IC. Identificador ClinicalTrials.gov: NCT01960920
Resumo:
Objectives: Physical fitness is related to all-cause mortality, quality of life and risk of falls in patients with type 2 diabetes. This study aimed to analyse the impact of a long-term community-based combined exercise program (aerobic + resistance + agility/balance + flexibility) developed with minimum and low-cost material resources on physical fitness in middle-aged and older patients with type 2 diabetes. Methods: This was a non-experimental pre-post evaluation study. Participants (N = 43; 62.92 ± 5.92 years old) were engaged in a community-based supervised exercise programme (consisting of combined aerobic, resistance, agility/balance and flexibility exercises; three sessions per week; 70 min per session) of 9 months' duration. Aerobic fitness (6-Minute Walk Test), muscle strength (30-Second Chair Stand Test), agility/balance (Timed Up and Go Test) and flexibility (Chair Sit and Reach Test) were assessed before (baseline) and after the exercise intervention. Results: Significant improvements in the performance of the 6-Minute Walk Test (Δ = 8.20%, p < 0.001), 30-Second Chair Stand Test (Δ = 28.84%, p < 0.001), Timed Up and Go Test (Δ = 14.31%, p < 0.001), and Chair Sit and Reach Test (Δ = 102.90%, p < 0.001) were identified between baseline and end-exercise intervention time points. Conclusions: A long-term community-based combined exercise programme, developed with low-cost exercise strategies, produced significant benefits in physical fitness in middle-aged and older patients with type 2 diabetes. This supervised group exercise programme significantly improved aerobic fitness, muscle strength, agility/balance and flexibility, assessed with field tests in community settings.
Resumo:
The dinoflagellates of Alexandrium genus are known to be producers of paralytic shellfish toxins that regularly impact the shellfish aquaculture industry and fisheries. Accurate detection of Alexandrium including A. minutum is crucial for environmental monitoring and sanitary issues. In this study, we firstly developed a quantitative lateral flow immunoassay (LFIA) using super-paramagnetic nanobeads for A. minutum whole cells. This dipstick assay relies on two distinct monoclonal antibodies used in a sandwich format and directed against surface antigens of this organism. No sample preparation is required. Either frozen or live cells can be detected and quantified. The specificity and sensitivity are assessed by using phytoplankton culture and field samples spiked with a known amount of cultured A. minutum cells. This LFIA is shown to be highly specific for A. minutum and able to detect reproducibly 105 cells/L within 30 min. The test is applied to environmental samples already characterized by light microscopy counting. No significant difference is observed between the cell densities obtained by these two methods. This handy super-paramagnetic lateral flow immnunoassay biosensor can greatly assist water quality monitoring programs as well as ecological research.
Resumo:
Obstructive lung diseases of different etiologies present with progressive peripheral airway involvement. The peripheral airways, known as the silent lung zone, are not adequately evaluated with conventional function tests. The principle of gas washout has been used to detect pulmonary ventilation inhomogeneity and to estimate the location of the underlying disease process. Volumetric capnography (VC) analyzes the pattern of CO2 elimination as a function of expired volume. To measure normalized phase 3 slopes with VC in patients with non-cystic fibrosis bronchiectasis (NCB) and in bronchitic patients with chronic obstructive pulmonary disease (COPD) in order to compare the slopes obtained for the groups. NCB and severe COPD were enrolled sequentially from an outpatient clinic (Hospital of the State University of Campinas). A control group was established for the NCB group, paired by sex and age. All subjects performed spirometry, VC, and the 6-Minute Walk Test (6MWT). Two comparisons were made: NCB group versus its control group, and NCB group versus COPD group. The project was approved by the ethical committee of the institution. Statistical tests used were Wilcoxon or Student's t-test; P<0.05 was considered to be a statistically significant difference. Concerning the NCB group (N=20) versus the control group (N=20), significant differences were found in body mass index and in several functional variables (spirometric, VC, 6MWT) with worse results observed in the NCB group. In the comparison between the COPD group (N=20) versus the NCB group, although patients with COPD had worse spirometric and 6MWT values, the capnographic variables mean phase 2 slope (Slp2), mean phase 3 slope normalized by the mean expiratory volume, or mean phase 3 slope normalized by the end-tidal CO2 concentration were similar. These findings may indicate that the gas elimination curves are not sensitive enough to monitor the severity of structural abnormalities. The role of normalized phase 3 slope may be worth exploring as a more sensitive index of small airway disease, even though it may not be equally sensitive in discriminating the severity of the alterations.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
A 12 week kayak training programme was evaluated in children who either had or did not have the anthropometric characteristics identified as being unique to senior elite sprint kayakers. Altogether, 234 male and female school children were screened to select 10 children with and 10 children without the identified key anthropometric characteristics. Before and after training, the children completed an all-out 2 min kayak ergometer simulation test; measures of oxygen consumption, plasma lactate and total work accomplished were recorded. In addition, a 500 m time trial was performed at weeks 3 and 12. The coaches were unaware which 20 children possessed those anthropometric characteristics deemed to favour development of kayak ability. All children improved in both the 2 min ergometer simulation test and 500 m time trial. However, boys who were selected according to favourable anthropometric characteristics showed greater improvement than those without such characteristics in the 2 min ergometer test only. In summary, in a small group of children selected according to anthropometric data unique to elite adult kayakers, 12 weeks of intensive kayak training did not influence the rate of improvement of on-water sprint kayak performance.
Resumo:
Background: Worsening in clinical and cardiac status has been noted after chronic right ventricular pacing, but it is uncertain whether atriobiventricular (BiVP) is preferable to atrio-right ventricular pacing (RVP). Conventional versus Multisite Pacing for BradyArrhythmia Therapy study (COMBAT) sought to compare BiVP versus RVP in patients with symptomatic heart failure (HF) and atrioventricular (AV) block. Methods and Results: COMBAT is a prospective multicenter randomized double blind crossover study. Patients with New York Heart Association functional class (FC) II-IV, left ventricular ejection fraction (LVEF) <40%, and AV block as an indication for pacing were enrolled. All patients underwent biventricular system implantation and then were randomized to receive successively (group A) RVP-BiVP-RVP, or (group B) BiVP-RVP-BiVP. At the end of each 3-month crossover period, patients were evaluated according to Quality of Life (QoL), FC, echocardiographic parameters, 6-Minute Walk Test (6MWT), and peak oxygen consumption (VO(2max)). Sixty patients were enrolled, and the mean follow-up period was 17.5 +/- 10.7 months. There were significant improvements in QoL, FC, LVEF, and left ventricular end-systolic volume with BiVP compared with RVP. The effects of pacing mode on 6MWT and VO(2max) were not significantly different. Death occurred more frequently with RVP. Conclusion: In patients with systolic HF and AV block requiring permanent ventricular pacing, BiVP is superior to RVP and should be considered the preferred pacing mode. (J Cardiac Fail 2010;16:293-300)
Resumo:
Background: Patients with idiopathic pulmonary fibrosis (IPF) present an important ventilatory (imitation reducing their exercise capacity. Non-invasive ventilatory support has been shown to improve exercise capacity in patients with obstructive diseases; however, its effect on IPF patients remains unknown. Objective: The present study assessed the effect of ventilatory support using proportional, assist ventilation (PAV) on exercise capacity in patients with IPF. Methods: Ten patients (61.2 +/- 9.2 year-old) were submitted to a cardiopulmonary exercise testing, plethysmography and three submaximal. exercise tests (60% of maximum load): without ventilatory support, with continuous positive airway pressure (CPAP) and PAV. Submaximal tests were performed randomly and exercise capacity, cardiovascular and ventilatory response as well as breathlessness subjective perception were evaluated. Lactate plasmatic levels were obtained before and after submaximal. exercise. Results: Our data show that patients presented a limited exercise capacity (9.7 +/- 3.8 mL O(2)/kg/min). Submaximal. test was increased in patients with PAV compared with CPAP and without ventilatory support (respectively, 11.1 +/- 8.8 min, 5.6 +/- 4.7 and 4.5 +/- 3.8 min; p < 0.05). An improved arterial oxygenation and lower subjective perception to effort was also observed in patients with IPF when exercise was performed with PAV (p < 0.05). IPF patients performing submaximal exercise with PAV also presented a lower heart rate during exercise, although systolic and diastolic pressures were not different among submaximal tests. Our results suggest that PAV can increase exercise tolerance and decrease dyspnoea and cardiac effort in patients with idiopathic pulmonary fibrosis. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
Quality of life (QOL) has been extensively studied in clinical trials and in research on chronic degenerative diseases and dementia. The aim of this study was to assess the reliability and construct validity of the Brazilian version of the QOL scale in Alzheimer`s disease (AD; QOL-AD). The QOL-AD was administered to 60 patients with mild or moderate AD and to their caregivers. The construct validation was accomplished through correlations amongst total scores of patients` and caregivers` reports on patients` quality of life (PQOL and C-PQOL, respectively), and data related to cognitive impairment, depressive symptoms, functional performance, behavioral disturbances and a generic instrument of quality of life (WHOQOL-brief), as well as correlation of total score of caregivers` reports on their own quality of life (CQOL) with the measurements cited above, QOL-AD patient reports, and depressive symptoms. The reliability was high for PQOL, C-PQOL, and CQOL versions (Cronbach`s alpha = 0.80, 0.83, and 0.86, respectively). We observed significant correlations in the construct validity of all three versions regarding the variables associated with the disease and also with WHOQOL-brief. The scale took, on average, six min for each version. The results indicate reliability and construct validity of the Brazilian version of the QOL-AD in the studied sample.
Resumo:
Introduction: Familial amyloidotic polyneuropathy (FAP) is a neurodegenerative disease that leads to sensory and motor polyneuropathies as well as functional limitations. So far, liver transplantation is the only treatment for FAP because the mutated protein causing the disease is mainly produced in the liver. With the increasing survival of transplant recipients, functional and cardiovascular problems as consequences of immunosuppressant side effects are increasing associated with sedentary lifestyles and/or retransplantation status. We sought to analyze the impact of exercise training programs on 1 FAP patient’s course long-term after liver transplantation. Methodology. A FAP patient (female; 49 years of age; body mass index 18.8 kg/m2) underwent a liver transplantation 133 months before assessment. She was assessed for body composition, isometric quadriceps muscle strength, functional capacity, fatigue, and levels of physical activity before and after a 6-month period of combined exercise training. Results: After the exercise training program, almost all variables were improved, namely, total body skeletal muscle mass, proximal femoral bone mineral density, quadriceps strength, maximal oxygen consumption on 6 minutes walk test (6mwt) or VO2peak, total ventilation on 6mwt, and fatigue. The improvement in distance on 6mwt (69.2 m) was clinically significant. Preintervention the levels of physical activity were below international recommendations for health; after the program they achieved the recommendations. Conclusion: The results showed an improvement in functional capacity with a decrease in future disability risk associated with a better lifestyle with respect to physical activity levels in 1 patient.
Resumo:
Liver transplantation is the unique treatment for several end stage diseases. Familial Amiloidotic Polineuropathy (FAP) is a neurodegenerative disease related with systemic deposition of amyloidal fibre mainly on peripheral nervous system, clinically translated by an autonomous sensitive-motor neuropathy with severe functional limitations in some cases. The unique treatment for FAP disease is a liver transplant with a very aggressive medication to muscle metabolism and force production. To our knowledge there are no quantitative characterizations of body composition, strength or functional capacity in this population. The purpose of this study was to compare levels of specific strength (isometric strength adjusted by lean mass or muscle quality) and functional capacity (meters in 6 minutes walk test) between FAP patients after a liver transplant (4.1±2 months after transplant surgery) (FAPT) and a healthy group (HG).