938 resultados para Single stage converters
Resumo:
Purpose: It is recognized that chronic inflammation can cause cancer. Even though most of the available synthetic meshes are considered non-carcinogenic, the inflammatory response to an infected mesh plays a constant aggression to the skin. Chronic mesh infection is frequently the result of misuse of mesh, and due to the challenging nature of this condition, patients usually suffer for years until the infected mesh is removed by surgical excision. Methods: We report two cases of squamous-cell carcinoma (SCC) of the abdominal wall, arising in patients with long-term mesh infection. Results: In both patients, the degeneration of mesh infection into SCC was presumably caused by the long-term inflammation secondary to infection. Patients presented with advanced SCC behaving just like the Marjolin's ulcers of burns. Radical surgical excision was the treatment of choice. The involvement of the bowel played an additional challenge in case 1, but it was possible to resect the tumor and the involved bowel and reconstruct the abdominal wall using polypropylene mesh as onlay reinforcement, in a single stage operation. He is now under adjuvant chemotherapy. The big gap in the midline after tumor resection in case 2 required mesh bridging to close the defect. The poor prognosis of case 2 who died months after the operation, and the involvement of the armpit, groin and mesenteric nodes in case 1 shows how aggressive this disease can be. Conclusion: Infected mesh must be treated early, by complete excision of the mesh. Long-standing mesh infection can degenerate into aggressive squamous-cell carcinoma of the skin. © 2013 Springer-Verlag France.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Engenharia Mecânica - FEB
Resumo:
Pós-graduação em Zootecnia - FCAV
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Na atualidade, o estudo do desempenho térmico de um sistema de refrigeração por compressão de vapor representa uma ferramenta importante no auxílio do desenvolvimento de novos produtos ou melhoria dos já existentes. Um modelo de simulação em regime permanente foi elaborado para avaliar o desempenho do sistema frigorífico. O sistema estudado inclui uma Central de Ar Condicionado, modelo PA HILTON, constituída de um compressor alternativo do tipo semi-hermético, evaporador e condensador compacto de tubos e aletas e uma válvula de expansão termostática. O modelo do condensador considera três regiões distintas de troca de calor as quais são respectivamente a região de dessuperaquecimento, condensação e subresfriamento. Para a modelagem do evaporador, foram consideradas as regiões de evaporação e superaquecimento. No modelo de simulação foram utilizadas correlações adequadas para a estimativa dos coeficientes de transferência de calor e perda de pressão para cada região do evaporador e condensador. Não foram consideradas a transferência de calor e queda de pressão nas linhas de conexão entre os componentes. A solução do sistema de equações não lineares resultantes da modelagem matemática dos componentes do sistema simulado foi obtida utilizando-se o método das substituições sucessivas com o emprego do software Engineenng Equation Solver . Os resultados obtidos pelo modelo de simulação apresentaram erros inferiores a 9% em relação aos valores experimentais.
Resumo:
Matrizes poliméricas como os hidrogéis são sistemas de liberação controlada que estão sendo largamente utilizados na indústria farmacêutica. Neste trabalho os hidrogéis de PAAm-co-MC foram obtidos e caracterizados afim de carrear o propranolol, fármaco anti-hipertensivo. Os hidrogéis compostos pelos monômeros AAm e MC foram sintetizados por polimerização via radical livre, sendo investigada quatro concentrações de AAm (3,6%; 7,2%; 14,7% e 21,7% m/v). A caracterização dos hidrogéis foi realizada com os estudos de grau de intumescimento, potencial zeta, IR-FT, MEV e análises térmicas (TG, DTA, DTG e DSC). O hidrogel 3,6% apresentou maior grau de intumescimento em todos os meios de análise. O potencial zeta revelou que todos os hidrogéis permanecem próximo do ponto isoelétrico. O espectro de absorção do infravermelho permitiu identificar bandas características, tanto do hidrogel como do propranolol. As curvas de TG dos hidrogéis evidenciaram a degradação dos mesmos em dois estágios, sendo observado na curva DTG a maior perda de massa em torno de 400ºC e as curvas DTA e DSC confirmaram os três eventos endotérmicos. Já o propranolol apresentou um único estágio de degradação e seu pico de fusão foi em 163,4ºC. As microfotografias relevaram a disposição da rede tridimensional dos hidrogéis. A relação da adsorção propranolol/hidrogel foi de 573 mg/g, seguindo o modelo da isoterma de Langmuir. No estudo da cinética de liberação in vitro a liberação do propranolol a partir da matriz do hidrogel foi de aproximadamente 80% do fármaco em 424 horas, apresentando um modelo bimodal. A realização deste trabalho demonstrou que o hidrogel de PAAm-co-MC é um grande promissor para aplicação em sistemas carreadores de fármacos.
Resumo:
This paper addresses the single stage lot-sizing problem in parallel machines. Each item can be produced on any machine, and incurs a setup time before to start the production. The objective of this paper is to obtain lower bounds of good quality for this problem. A solution method is developed based on a reformulation of the problem and the Lagrangian relaxation of a set of constraints. Some computational results are presented comparing the proposed method with a method from the literature and with a computational package.
Resumo:
Pós-graduação em Zootecnia - FCAV
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
H2 demand is continuously increasing since its many relevant applications, for example, in the ammonia production, refinery processes or fuel cells. The Water Gas Shift (WGS) reaction (CO + H2O = CO2 + H2 DeltaH = -41.1 kJ.mol-1) is a step in the H2 production, reducing significantly the CO content and increasing the H2 one in the gas mixtures obtained from steam reforming. Industrially, the reaction is carried out in two stages with different temperature: the first stage operates at high temperature (350-450 °C) using Fe-based catalysts, while the second one is performed at lower temperature (190-250 °C) over Cu-based catalysts. However, recently, an increasing interest emerges to develop new catalytic formulations, operating in a single-stage at middle temperature (MTS), while maintaining optimum characteristics of activity and stability. These formulations may be obtained by improving activity and selectivity of Fe-based catalysts or increasing thermal stability of Cu-based catalysts. In the present work, Cu-based catalysts (Cu/ZnO/Al2O3) prepared starting from hydrotalcite-type precursors show good homogeneity and very interesting physical properties, which worsen by increasing the Cu content. Among the catalysts with different Cu contents, the catalyst with 20 wt.% of Cu represents the best compromise to obtain high catalytic activity and stability. On these bases, the catalytic performances seem to depend on both metallic Cu surface area and synergetic interactions between Cu and ZnO. The increase of the Al content enhances the homogeneity of the precursors, leading to a higher Cu dispersion and consequent better catalytic performances. The catalyst with 20 wt.% of Cu and a molar ratio M(II)/M(III) of 2 shows a high activity also at 250 °C and a good stability at middle temperature. Thus, it may be considered an optimum catalyst for the WGS reaction at middle temperature (about 300 °C). Finally, by replacing 50 % (as at. ratio) of Zn by Mg (which is not active in the WGS reaction), better physical properties were observed, although associate with poor catalytic performances. This result confirms the important role of ZnO on the catalytic performances, favoring synergetic interactions with metallic Cu.
Resumo:
In questo lavoro di tesi si è elaborato un quadro di riferimento per l’utilizzo combinato di due metodologie di valutazione di impatti LCA e RA, per tecnologie emergenti. L’originalità dello studio sta nell’aver proposto e anche applicato il quadro di riferimento ad un caso studio, in particolare ad una tecnologia innovativa di refrigerazione, basata su nanofluidi (NF), sviluppata da partner del progetto Europeo Nanohex che hanno collaborato all’elaborazione degli studi soprattutto per quanto riguarda l’inventario dei dati necessari. La complessità dello studio è da ritrovare tanto nella difficile integrazione di due metodologie nate per scopi differenti e strutturate per assolvere a quegli scopi, quanto nel settore di applicazione che seppur in forte espansione ha delle forti lacune di informazioni circa processi di produzione e comportamento delle sostanze. L’applicazione è stata effettuata sulla produzione di nanofluido (NF) di allumina secondo due vie produttive (single-stage e two-stage) per valutare e confrontare gli impatti per la salute umana e l’ambiente. Occorre specificare che il LCA è stato quantitativo ma non ha considerato gli impatti dei NM nelle categorie di tossicità. Per quanto concerne il RA è stato sviluppato uno studio di tipo qualitativo, a causa della problematica di carenza di parametri tossicologici e di esposizione su citata avente come focus la categoria dei lavoratori, pertanto è stata fatta l’assunzione che i rilasci in ambiente durante la fase di produzione sono trascurabili. Per il RA qualitativo è stato utilizzato un SW specifico, lo Stoffenmanger-Nano che rende possibile la prioritizzazione dei rischi associati ad inalazione in ambiente di lavoro. Il quadro di riferimento prevede una procedura articolata in quattro fasi: DEFINIZIONE SISTEMA TECNOLOGICO, RACCOLTA DATI, VALUTAZIONE DEL RISCHIO E QUANTIFICAZIONE DEGLI IMPATTI, INTERPRETAZIONE.
Resumo:
The energy harvesting research field has grown considerably in the last decade due to increasing interests in energy autonomous sensing systems, which require smart and efficient interfaces for extracting power from energy source and power management (PM) circuits. This thesis investigates the design trade-offs for minimizing the intrinsic power of PM circuits, in order to allow operation with very weak energy sources. For validation purposes, three different integrated power converter and PM circuits for energy harvesting applications are presented. They have been designed for nano-power operations and single-source converters can operate with input power lower than 1 μW. The first IC is a buck-boost converter for piezoelectric transducers (PZ) implementing Synchronous Electrical Charge Extraction (SECE), a non-linear energy extraction technique. Moreover, Residual Charge Inversion technique is exploited for extracting energy from PZ with weak and irregular excitations (i.e. lower voltage), and the implemented PM policy, named Two-Way Energy Storage, considerably reduces the start-up time of the converter, improving the overall conversion efficiency. The second proposed IC is a general-purpose buck-boost converter for low-voltage DC energy sources, up to 2.5 V. An ultra-low-power MPPT circuit has been designed in order to track variations of source power. Furthermore, a capacitive boost circuit has been included, allowing the converter start-up from a source voltage VDC0 = 223 mV. A nano-power programmable linear regulator is also included in order to provide a stable voltage to the load. The third IC implements an heterogeneous multisource buck-boost converter. It provides up to 9 independent input channels, of which 5 are specific for PZ (with SECE) and 4 for DC energy sources with MPPT. The inductor is shared among channels and an arbiter, designed with asynchronous logic to reduce the energy consumption, avoids simultaneous access to the buck-boost core, with a dynamic schedule based on source priority.
Resumo:
In the last years, the European countries have paid increasing attention to renewable sources and greenhouse emissions. The Council of the European Union and the European Parliament have established ambitious targets for the next years. In this scenario, biomass plays a prominent role since its life cycle produces a zero net carbon dioxide emission. Additionally, biomass can ensure plant operation continuity thanks to its availability and storage ability. Several conventional systems running on biomass are available at the moment. Most of them are performant either in the large-scale or in the small power range. The absence of an efficient system on the small-middle scale inspired this thesis project. The object is an innovative plant based on a wet indirectly fired gas turbine (WIFGT) integrated with an organic Rankine cycle (ORC) unit for combined heat and power production. The WIFGT is a performant system in the small-middle power range; the ORC cycle is capable of giving value to low-temperature heat sources. Their integration is investigated in this thesis with the aim of carrying out a preliminary design of the components. The targeted plant output is around 200 kW in order not to need a wide cultivation area and to avoid biomass shipping. Existing in-house simulation tools are used: They are adapted to this purpose. Firstly the WIFGT + ORC model is built; Zero-dimensional models of heat exchangers, compressor, turbines, furnace, dryer and pump are used. Different fluids are selected but toluene and benzene turn out to be the most suitable. In the indirectly fired gas turbine a pressure ratio around 4 leads to the highest efficiency. From the thermodynamic analysis the system shows an electric efficiency of 38%, outdoing other conventional plants in the same power range. The combined plant is designed to recover thermal energy: Water is used as coolant in the condenser. It is heated from 60°C up to 90°C, ensuring the possibility of space heating. Mono-dimensional models are used to design the heat exchange equipment. Different types of heat exchangers are chosen depending on the working temperature. A finned-plate heat exchanger is selected for the WIFGT heat transfer equipment due to the high temperature, oxidizing and corrosive environment. A once-through boiler with finned tubes is chosen to vaporize the organic fluid in the ORC. A plate heat exchanger is chosen for the condenser and recuperator. A quasi-monodimensional model for single-stage axial turbine is implemented to design both the WIFGT and the ORC turbine. The system simulation after the components design shows an electric efficiency around 34% with a decrease by 10% compared to the zero-dimensional analysis. The work exhibits the system potentiality compared to the existing plants from both technical and economic point of view.