971 resultados para Silicon detectors, transient current technique (TCT), TCAD, ATLAS, ATHENA, SILAVACO, MixedMode


Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present results, obtained by means of an analytic study and a numerical simulation, about the resonant condition necessary to produce a Localized Surface Plasmonic Resonance (LSPR) effect at the surface of metal nanospheres embedded in an amorphous silicon matrix. The study is based on a Lorentz dispersive model for a-Si:H permittivity and a Drude model for the metals. Considering the absorption spectra of a-Si:H, the best choice for the metal nanoparticles appears to be aluminium, indium or magnesium. No difference has been observed when considering a-SiC:H. Finite-difference time-domain (FDTD) simulation of an Al nanosphere embedded into an amorphous silicon matrix shows an increased scattering radius and the presence of LSPR induced by the metal/semiconductor interaction under green light (560 nm) illumination. Further results include the effect of the nanoparticles shape (nano-ellipsoids) in controlling the wavelength suitable to produce LSPR. It has been shown that is possible to produce LSPR in the red part of the visible spectrum (the most critical for a-Si:H solar cells applications in terms of light absorption enhancement) with aluminium nano-ellipsoids. As an additional results we may conclude that the double Lorentz-Lorenz model for the optical functions of a-Si:H is numerically stable in 3D simulations and can be used safely in the FDTD algorithm. A further simulation study is directed to determine an optimal spatial distribution of Al nanoparticles, with variable shapes, capable to enhance light absorption in the red part of the visible spectrum, exploiting light trapping and plasmonic effects. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

RESUMO: A cefaleia cervicogénica é uma forma comum de dor de cabeça, que tem sido associada à existência de uma disfunção das estruturas da coluna cervical superior. Estudos recentes mostram uma grande incidência dessa disfunção a nível de C1-C2, avaliada pelo teste de flexão-rotação. Vários terapeutas manuais, como Brian Mulligan e Mariano Rocabado, têm sido sugerido técnicas de tratamento para este tipo de disfunção. Contudo, a evidência acerca da efectividade dessas técnicas é escassa. Desenho do estudo: Foi efectuado um ensaio clínico aleatório, duplamente cego, composto por três fases: pré-intervenção, intervenção e pós-intervenção. Objectivos: Avaliar e comparar os efeitos imediatos de duas técnicas de Terapia Manual Ortopédica (SNAG C1/2 de Mulligan e técnica de desrotação do atlas de Rocabado), na amplitude de movimento de rotação do segmento vertebral C1-C2, em indivíduos com história de cefaleia cervicogénica e com limitação no teste de flexão-rotação. As técnicas de tratamento foram usadas de forma isolada, em comparação a um grupo placebo. Métodos: Uma amostra de 60 indivíduos, com cefaleia cervicogénica e limitação do teste de flexão-rotação, foram aleatoriamente distribuídos por três grupos: SNAG C1/2 de Mulligan, técnica de desrotação do atlas de Rocabado e grupo placebo. O outcome primário foi a amplitude de movimento obtida no teste de flexão-rotação, que foi medido antes e imediatamente após a intervenção. Resultados: Imediatamente após a intervenção, a amplitude verificada no teste de flexão-rotação aumentou 21.8º (DP, 4.68) no grupo submetido ao SNAG C1/2 de Mulligan, 15º (DP, 5.07) no grupo em que foi aplicada a técnica de desrotação do atlas de Rocabado e 0.65º (DP, 0.67) no grupo placebo. Uma ANOVA modelo misto, 2 por 3, revelou efeito principal significativo do tempo (p<.001) e grupo (p<.001), assim como uma interacção significativa entre grupo e tempo (p<.001), relativamente à variável amplitude do teste de flexão-rotação. Estes resultados indicam que as diferenças verificadas entre os grupos eram dependentes do momento de avaliação. Uma comparação múltipla post hoc revelou que quer as técnicas de Mulligan, quer de Rocabado, produziram efeitos significativamente maiores que a intervenção placebo na amplitude de movimento do teste de flexão-rotação (p<.001 e p=.001, respectivamente). No entanto,não se verificou uma diferença significativa no que diz respeito à efectividade de ambas as técnicas de Terapia Manual Ortopédica aplicadas (p=.42). Conclusão: Esta investigação sugere que as duas técnicas de Terapia Manual Ortopédica avaliadas produziram efeito clínica e estatisticamente significativo na amplitude do teste de flexão-rotação. No entanto, não se verificaram diferenças entre as duas técnicas, no que diz respeito ao seu efeito no ganho de amplitude de movimento. Os resultados obtidos fornecem evidência preliminar sobre a efectividade de ambas as intervenções no tratamento da redução de amplitude de movimento em indivíduos com história de cefaleia cervicogénica.-------------------------------ABSTRACT:Background: Cervicogenic headache is a common form of headache arising from dysfunction in structures of the upper cervical spine. Recent studies have shown a high incidence of C1/2 dysfunction, evaluated by the flexion-rotation test (FRT). Several manual therapists have suggested different approaches to manage that dysfunction, such as Brian Mulligan and Mariano Rocabado. However, the evidence of the effectiveness of those manual techniques is anedoctal. Design: Randomized double blinded controlled trial with three phases: pre-intervention, intervention and post-intervention. Objectives: To determine and compare the immediate effects of two manual therapy techniques (Mulligan’s SNAG C1/2 and Rocabado’s atlas’ derotation technique) in the range of motion of C1-C2 vertebral segments, in cervicogenic headache patients and with limitation on the flexion-rotatoin test. The treatment techniques were used as single treatments against a placebo group. Methods: A sample of 60 subjects with cervicogenic headache and FRT limitation were randomly allocated into one of three groups: Mulligan’s C1/2 SNAG, Rocabado’s atlas derotation technique or placebo group. The primary outcome was the flexion rotation test range, which was measured before and immediately after the intervention. Results: Immediately after the application of the interventions, FRT range increased by 21.8º (SD, 4.68) for the Mulligan’s C1-2 SNAG group, 15º (SD, 5.07) for the Rocabado’s atlas derotation technique and 0.65º (SD, 0.67) for the placebo group. A 2-by-3 mixedmodel ANOVA a significant main effect of time (p<.001) and group (p<.001), as well as a significant interaction between group and time (p<.001) for the variable FRT range. These results indicate that group differences were dependent on time. A pairwise post hoc comparison revelad that both the Mulligan and Rocabado techniques produced significantly more effect on FRT range of motion than the placebo intervention (p<.001 and p=.001, respectively). However, there was not a significant difference between the effectiveness of the two manual therapy techniques (p=.42).Conclusion: This investigation’s findings suggest that both Mulligan’s C1/2 SNAG and Rocabado’s atlas derotation techniques produced a clinically and statistically significant effect on FRT range, but there were no changes between the two techniques in their effectiveness. These results provide preliminary evidence for the efficacy of both manual therapy techniques in the management of individuals with cervicogenic headache and FRT limitation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Breast cancer is the most common type of cancer worldwide. The effectiveness of its treatment depends on early stage detection, as well as on the accuracy of its diagnosis. Recently, diagnosis techniques have been submitted to relevant breakthroughs with the upcoming of Magnetic Resonance Imaging, Ultrasound Sonograms and Positron Emission Tomography (PET) scans, among others. The work presented here is focused on studying the application of a PET system to a Positron Emission Mammography (PEM) system. A PET/PEM system works under the principle that a scintillating crystal will detect a gamma-ray pulse, originated at the cancerous cells, converting it into a correspondent visible light pulse. The latter must then be converted into an electrical current pulse by means of a Photo- -Sensitive Device (PSD). After the PSD there must be a Transimpedance Amplifier (TIA) in order to convert the current pulse into a suitable output voltage, in a time period lower than 40 ns. In this Thesis, the PSD considered is a Silicon Photo-Multiplier (SiPM). The usage of this recently developed type of PSD is impracticable with the conventional TIA topologies, as it will be proven. Therefore, the usage of the Regulated Common-Gate (RCG) topology will be studied in the design of the amplifier. There will be also presented two RCG variations, comprising a noise response improvement and differential operation of the circuit. The mentioned topology will also be tested in a Radio-Frequency front-end, showing the versatility of the RCG. A study comprising a low-voltage self-biasing feedback TIA will also be shown. The proposed circuits will be simulated with standard CMOS technology (UMC 130 nm), using a 1.2 V power supply. A power consumption of 0.34 mW with a signal-to-noise ratio of 43 dB was achieved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

It is important to have better evaluation and understanding of the motor neuron physiology, with the goal to early and objectively diagnose and treat patients with neurodegenerative pathologies. The Compound Muscle Action Potential (CMAP) scan is a non-invasive diagnosis technique for neurodegenerative pathologies, such as ALS, and enables a quick analysis of the muscle action potentials in response to motor nerve stimulation. This work aims to study the influence of different pulse modulated waveforms in peripheral nerve excitability by CMAP scan technique on healthy subjects. A total of 13 healthy subjects were submitted to the same test. The stimuli were applied in the medium nerve on the right wrist and electromyography signal collected on the Abductor Pollicis Brevis (APB) muscle surface on the right thumb. Stimulation was performed with an increasing intensities range from 4 to 30 mA, with varying steps, 3 stimuli per step. The procedure was repeated 4 times per subject, each repetition using a different single pulse stimulation waveform: monophasic square, monophasic triangular, monophasic quadratic and biphasic square. Results were retrieved from the averaging of the stimuli on each current intensity step. The square pulse needs less current intensity to generate the same response amplitude regarding the other waves and presents a more steep curve slope and this effect is gradually decreasing for the triangular and quadratic pulse,respectively, being the difference even more evident regarding the biphasic pulse. The control of the waveform stimulation pulse allows varying the stimulusresponse curve slope.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A transimpedance amplifier (TIA) is used, in radiation detectors like the positron emission tomography(PET), to transform the current pulse produced by a photo-sensitive device into an output voltage pulse with a desired amplitude and shape. The TIA must have the lowest noise possible to maximize the output. To achieve a low noise, a circuit topology is proposed where an auxiliary path is added to the feedback TIA input, In this auxiliary path a differential transconductance block is used to transform the node voltage in to a current, this current is then converted to a voltage pulse by a second feedback TIA complementary to the first one, with the same amplitude but 180º out of phase with the first feedback TIA. With this circuit the input signal of the TIA appears differential at the output, this is used to try an reduced the circuit noise. The circuit is tested with two different devices, the Avalanche photodiodes (APD) and the Silicon photomultiplier (SIPMs). From the simulations we find that when using s SIPM with Rx=20kΩ and Cx=50fF the signal to noise ratio is increased from 59 when using only one feedback TIA to 68.3 when we use an auxiliary path in conjunction with the feedback TIA. This values where achieved with a total power consumption of 4.82mv. While the signal to noise ratio in the case of the SIPM is increased with some penalty in power consumption.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To illustrate the radiological findings and review the current literature concerning a rare congenital abnormality of the posterior arch of the atlas. CASE REPORT: An adult female without neurological symptoms presented with an absent posterior arch of the atlas, examined with plain films and helical computerized tomography. Complete agenesis of the posterior arch of the atlas is a rare entity that can be easily identified by means of plain films. Although it is generally asymptomatic, atlantoaxial instability and neurological deficits may occur because of structural instability. Computerized tomography provides a means of assessing the extent of this abnormality and can help evaluate the integrity of neural structures. Although considered to be rare entities, defects of the posterior arch of the atlas may be discovered as incidental asymptomatic findings in routine cervical radiographs. Familiarity with this abnormality may aid medical professionals in the correct management of these cases.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study presents an experimental program to assess the tensile strain distribution along prestressed carbon fiber reinforced polymer (CFRP) reinforcement flexurally applied on the tensile surface of RC beams according to near surface mounted (NSM) technique. Moreover, the current study aims to propose an analytical formulation, with a design framework, for the prediction of distribution of CFRP tensile strain and bond shear stress and, additionally, the prestress transfer length. After demonstration the good predictive performance of the proposed analytical approach, parametric studies were carried out to analytically evaluate the influence of the main material properties, and CFRP and groove cross section on the distribution of the CFRP tensile strain and bond shear stress, and on the prestress transfer length. The proposed analytical approach can also predict the evolution of the prestress transfer length during the curing time of the adhesive by considering the variation of its elasticity modulus during this period.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents measurements from the ATLAS experiment of the forward-backward asymmetry in the reaction pp→Z/γ∗→l+l−, with l being electrons or muons, and the extraction of the effective weak mixing angle. The results are based on the full set of data collected in 2011 in pp collisions at the LHC at s√ = 7 TeV, corresponding to an integrated luminosity of 4.8 fb−1. The measured asymmetry values are found to be in agreement with the corresponding Standard Model predictions. The combination of the muon and electron channels yields a value of the effective weak mixing angle of 0.2308±0.0005(stat.)±0.0006(syst.)±0.0009(PDF), where the first uncertainty corresponds to data statistics, the second to systematic effects and the third to knowledge of the parton density functions. This result agrees with the current world average from the Particle Data Group fit.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work describes the influence of a high annealing temperature of about 700C on the Si(substrate)/Si3N4/TiOx/Pt/LiCoO2 multilayer system for the fabrication of all-solid-state lithium ion thin film microbatteries. Such microbatteries typically utilize lithium cobalt oxide (LiCoO2) as cathode material with a platinum (Pt) current collector. Silicon nitride (Si3N4) is used to act as a barrier against Li diffusion into the substrate. For a good adherence between Si3N4 and Pt, commonly titanium (Ti) is used as intermediate layer. However, to achieve crystalline LiCoO2 the multilayer system has to be annealed at high temperature. This post-treatment initiates Ti diffusion into the Pt-collector and an oxidation to TiOx, leading to volume expansion and adhesion failures. To solve this adhesion problem, we introduce titanium oxide (TiOx) as an adhesion layer, avoiding the diffusion during the annealing process. LiCoO2, Pt and Si3N4 layers were deposited by magnetron sputtering and the TiOx layer by thermal oxidation of Ti layers deposited by e-beam technique. Asdeposited and annealed multilayer systems using various TiOx layer thicknesses were studied by scanning electron microscopy (SEM) and time-of-flight secondary ion mass spectrometry (ToF-SIMS) and x-ray photoelectron spectroscopy (XPS). The results revealed that an annealing process at temperature of 700C leads to different interactions of Ti atoms between the layers, for various TiOx layer thicknesses (25–45 nm).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The ATLAS experiment at the LHC has measured the Higgs boson couplings and mass, and searched for invisible Higgs boson decays, using multiple production and decay channels with up to 4.7 fb−1 of pp collision data at √s=7 TeV and 20.3 fb−1 at √s=8 TeV. In the current study, the measured production and decay rates of the observed Higgs boson in the γγ, ZZ, W W , Zγ, bb, τ τ , and μμ decay channels, along with results from the associated production of a Higgs boson with a top-quark pair, are used to probe the scaling of the couplings with mass. Limits are set on parameters in extensions of the Standard Model including a composite Higgs boson, an additional electroweak singlet, and two-Higgs-doublet models. Together with the measured mass of the scalar Higgs boson in the γγ and ZZ decay modes, a lower limit is set on the pseudoscalar Higgs boson mass of m A > 370 GeV in the “hMSSM” simplified Minimal Supersymmetric Standard Model. Results from direct searches for heavy Higgs bosons are also interpreted in the hMSSM. Direct searches for invisible Higgs boson decays in the vector-boson fusion and associated production of a Higgs boson with W/Z (Z → ℓℓ, W/Z → jj) modes are statistically combined to set an upper limit on the Higgs boson invisible branching ratio of 0.25. The use of the measured visible decay rates in a more general coupling fit improves the upper limit to 0.23, constraining a Higgs portal model of dark matter.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tese de Doutoramento Programa Doutoral em Engenharia Electrónica e Computadores.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In modern society, thiamine deficiency (TD) remains an important medical condition linked to altered cardiac function. There have been contradictory reports about the impact of TD on heart physiology, especially in the context of cardiac excitability. In order to address this particular question, we used a TD rat model and patch-clamp technique to investigate the electrical properties of isolated cardiomyocytes from epicardium and endocardium. Neither cell type showed substantial differences on the action potential waveform and transient outward potassium current. Based on our results we can conclude that TD does not induce major electrical remodeling in isolated cardiac myocytes in either endocardium or epicardium cells.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The demonstration by computed tomography of abnormalities related to asbestos is essential for the recognition of industrial disease, the compensation of which has considerable economic consequences. The use of compute tomography, the most reliable technique for the detection of pleuro-parenchymatous abnormalities related to asbestos exposure, has increased considerably in France since the publication of the results of a consensus conference in Paris in 1999. Since that time, developments in technology have noticeably modified the protocols of investigation and increased the sensitivity of the detection of pleural and interstitial parenchymatous abnormalities and of nodules. The technical recommendations and those for the interpretation of pleural and parenchymatous abnormalities need to be well known. They are presented in the form of an atlas that gives detailed criteria for asbestosis, pleural plaques and pleural fibrosis. The diagnosis of pleural plaques depends on the combination of clear limits at the pleural and pulmonary interface, typical topography and multiple, bilateral localization. In the context of asbestos exposure the plaques are characteristic of this exposure, unlike diffuse pleural thickening, crow's feet images, parenchymatous bands and entrapped atalectasis. The writing of the radiological report would be most appropriate on this basis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AbstractAcidosis is encountered during tissue inflammation and triggers pain in humans. H+-gated ion channels are expressed at high levels in sensory neurons of the peripheral nervous system. Ion channels from two different families present the required pH sensitivity to detect the acidosis associated with peripheral inflammation: Acid-Sensing Ion Channels (ASICs) and the Transient Receptor Potential Vanilloid-1 (TRPV1) channel.ASICs are members of the Degenerin/Epithelial Na+ Channel family of ion channels. Six ASIC subunits have been identified in mammals (ASICla, -lb, -2a, -2b, -3 and -4). ASICs form In-activated voltage-insensitive homo- or heterotrimeric Na+ channels. TRPV1 is a member of the TRP family of ion channels and forms non-selective cation channels that mediate a sustained current. TRPV1 is activated by H+, heat (T>43°C), lipids, capsaicin, voltage and other stimuli. A stimulus can increase TRPV1 response to a different stimulus. For example H+ can shift the capsaicin concentration dependence of TRPV1 to lower values. ASICs and TRPV1 have been shown to be involved in inflammatory pain. Using the patch-clamp technique, we studied different aspects of the function of ASICs and TRPV1 in the physiological context of pain.In the first part of this thesis, we characterize the effect of a temperature increase from 25 to 35°C on the function of ASICs and TRPV1 in transfected CHO cells and primary cultures of rat DRG sensory neurons. ASICs give rise to transient currents while TRPV1 mediates a sustained current. In addition, ASICs and TRPV1 respond to H+ with distinct pH dependences. We assess the relative contribution of ASICs and TRPV1 to H+-evoked electrical signaling in rat DRG neurons and we conclude that ASICs are the most important pH sensors in the pH range 7.4 to 6.0 at 35°C in sensory neurons.ASICs and TRPV1 are expressed in the epithelium lining the lumen of the bladder (urothelium). The Bladder Pain Syndrome/Interstitial Cystitis (BPS/IC) is a painful condition associated with a dysfunction of the urothelial barrier and with inflammation. In the second part of this thesis, we show that human urothelial cells -the cell line TEU2 and primary cultures of human bladder urothelium- express functional ASICs but no functional TRPV1 channels. In addition, we show that the levels of ASIC2 and ASIC3 mRNA are increased in the urothelium of patients suffering from BPS/IC. These data suggest that ASICs are involved in the pathology of BPS/IC.Finally, we demonstrate that APETx2 inhibits the sensory neuron specific voltage-dependent Na+ channel Nav1.8. APETx2 was previously shown to inhibit homo- or heterotrimeric ASIC3- containing channels with IC5o from 0.08 to 1 μΜ. We show that APETx2 also inhibits Nav1.8 with an ICsoof «2.6 μΜ. APETx2 reduces the maximal conductance and induces a depolarizing shift in the voltage dependence of activation of Nav1.8. In current-clamp experiments, APETx2 reduces the number of action potentials (APs) evoked by a current ramp. Nav1.8 mediates most of the current during the AP upstroke and has been shown to be an important mediator of inflammatory pain. The fact that APETx2 inhibits two ion channels involved in inflammatory pain suggests that APETx2 or derivatives may represent novel analgesic compounds.RésuméL'acidose tissulaire est observée durant l'inflammation et entraine la douleur chez l'humain. Des canaux ioniques activés par les protons (H+) sont fortement exprimés dans les neurones sensoriels du système nerveux périphérique. De ceux-ci, les Acid-Sensing Ion Channels [ASICs) et Transient Receptor Potential Vanilloid-1 (TRPV1) présentent une sensibilité adéquate à l'acidité pour servir de détecteurs d'acidose.Les ASICs sont membres de la famille Degenerin/Epithelial Na* Channel. Six sous-unités ASIC ont été identifiées chez les mammifères (ASICla, -lb, -2a, -2b, -3 et -4). Les ASICs forment des canaux sélectifs au Na\ insensibles au voltage et activés par les H+. Les canaux fonctionnels sont des homo- ou hétérotrimères de sous-unités ASIC. TRPV1 est un membre de la famille TRP de canaux ioniques. Les canaux TRPV1 sont activés par les H+, la chaleur (T>43°Ç), les lipides, la capsaicine, le voltage et d'autres stimulus. L'activation de TRPV1 entraine un courant soutenu non-sélectif. Un stimulus peut augmenter la réponse de TRPV1 à un autre stimulus. Les H+ peuvent, par exemple, induire un décalage vers des valeurs plus faibles de la courbe de dépendance à la concentration de TRPV1 pour la capsaicine. Il a été démontré que les ASICs et TRPV1 sont impliqués dans la douleur inflammatoire. En utilisant la technique du patch-clamp, nous avons étudié différents aspects de la fonction des ASICs et de TRPV1 dans des contextes associés à la douleur.Dans la première partie de cette thèse, nous caractérisons l'effet d'une augmentation de température de 25 à 35°C sur la fonction des canaux ASICs et TRPV1, dans des cellules CHO transfectées et dans des cultures primaires de neurones sensoriels (DRG) de rat. L'activation des ASICs entraine l'apparition d'un courant transitoire tandis que l'activation de TRPV1 entraine un courant soutenu. De plus, les ASICs et TRPV1 possèdent des dépendances au pH différentes. Nous évaluons la contribution relative des ASICs et de TRPV1 au signalement électrique induit par les H+ et nous concluons que les ASICs sont les senseurs d'acidité les plus importants dans les neurones sensoriels, dans le domaine de pH de 7.4 à 6.0, à température corporelle.Les ASICs et TRPV1 sont exprimés dans l'épithélium recouvrant l'intérieur de la vessie (l'urothélium). Le Bladder Pain Syndrome/Interstitial Cystitis (BPS/IC) est une condition médicale douloureuse associée à une dysfonction de la barrière urothéliale et à une inflammation. Dans la seconde partie de cette thèse, nous démontrons que des cellules urothéliales (de la lignée cellulaire TEU2) et des cellules provenant de cultures primaires d'épithéliums de vessies humaines expriment des canaux ASIC fonctionnels mais pas de TRPV1 fonctionnels. De plus, nous montrons que le niveau d'expression de ASIC2 et -3 est augmenté dans l'urothélium de la vessie de patients souffrant de BPS/IC. Ces données suggèrent que les ASICs sont impliqués dans la pathologie BPS/IC.Pour finir, nous démontrons que la toxine APETx2 inhibe le canal spécifique aux neurones sensoriels Nav1.8, un membre de la famille des canaux sodiques dépendants du potentiel. Il a été démontré précédemment que la toxine APETx2 inhibe les canaux contenant une ou plusieurs sous-unités ASIC3 avec un ICso entre 0.08 et 1 μΜ. Nous montrons que la toxine APETx2 inhibe Nav1.8 avec un IC50 de «2.6 μΜ. La toxine APETx2 réduit la conductance maximale et induit un décalage de la dépendance au potentiel de Nav1.8 vers des valeurs plus positives. Dans des expériences de courant imposé sur des neurones sensoriels, la toxine APETx2 réduit le nombre de potentiels d'action induits par une rampe de courant. Nav1.8 est responsable de la majeure partie du courant durant la phase ascendante du potentiel d'action et a été démontré comme étant un médiateur important de la douleur inflammatoire. L'inhibition de deux types de canaux, impliqués dans la douleurs inflammatoire, par la toxine APETx2, suggère que cette dernière ou ses dérivés représentent des composés analgésiques prometteurs.