154 resultados para Sedação


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Anestesiologia - FMB

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to determine the angle of motion values for hindlimbs in clinically healthy adult Santa Ines sheep using a standard goniometer. Twenty female Santa Ines sheep weighing 32–45 kg (mean30.4, SD=3.7), and aged from three to six years old were used. A standard transparent plastic goniometer was used to measure passive maximum flexion, maximum extension, and range of motion (ROM) of the shoulder, elbow, carpal, hip, stifle, and tarsal joints, in the right and left limbs. The goniometric measurements were done with the sheep awake and in a standing position. The measurements were made in triplicate by two independent investigators. In all evaluated joints there was no significant difference between the means of both sides. No significant difference was observed between measurements performed by the two investigators. The mean (± SD) values of the measurements (degrees) were: 129 ± 4 (ROM) for tarsal joint; 46 ± 4 (flexion), 146 ± 6 (extension), and 100 ± 4 (ROM) for stifle joint; 54 ± 3 (flexion), 143 ± 7 (extension), and 89 ± 5 (ROM) for hip joint. The data obtained is useful to provide objective information of the joints. More studies are necessary using other breeds

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The equine anesthesia is proven to be a high risk procedure, for both patient and anesthetist, compared to other animal species. In these conditions, a good anesthetic protocol that can deliver sedation, making access and manipulation easier, analgesia fair enough to realize cirurgical procedures, and minimal physiologic changes would be ideal. Since there aren’t any drugs suporting all these qualities, the Neuroleptoanalgesic Associations show themselves as a valuable technique to provide anesthetic quality and safety, possibly diminishing our drug of choice’s doses, therefore offering less fisiological changes and easier monetary access in some cases. This paper objective was to list all these associations found in literature, evaluating their advantages and practical applications

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Eventos adversos a medicamentos (EAM) ainda são uma das principais limitações nos serviços de cuidados com a saúde, causando risco aos pacientes, além de grande impacto econômico. Assim, fazem-se necessários métodos de identificação de eventos adversos mais eficazes que a tradicional notificação espontânea, a qual revela apenas 5% do total de eventos. A utilização de critérios rastreadores (ou trigger tools), elaborados pelo Institute for Healthcare Improvement, tem se mostrado como a alternativa mais válida e eficiente para a triagem dos EAM. Com o objetivo principal de identificar os principais eventos adversos e medicamentos envolvidos, uma seleção de três critérios rastreadores foi utilizada, a saber: INR (razão normalizada internacional) > 6, WBC (contagem de leucócitos) < 3000/mm³ ou registros de episódios de sedação excessiva, letargia ou queda. Informações sobre os rastreadores foram coletadas e analisadas a partir dos prontuários de pacientes internados no Hospital Estadual Américo Brasiliense internados, de novembro de 2011 a janeiro de 2012 e maio a julho de 2012, a fim de se confirmar a ocorrência de evento adverso. Foram analisados prontuários referentes a 3318 hospitalizações, nas quais foram detectados 69 eventos adversos, 49 dos quais foram causados por apenas quatro das 12 classes de medicamentos envolvidos em algum EAM: anticoagulantes orais, relacionados ao rastreador INR>6 (eficácia = 0,75), sedativos e antipsicóticos, relacionados ao rastreador de sedação excessiva, letargia ou queda (eficácia = 0,52), e antivirais, relacionados ao rastreador WBC<3000 (eficácia = 0,48). Quando os rastreadores eram acionados e não estavam relacionados a EAM, os fatores de confusão mais recorrentes foram: torpor secundário ao quadro clínico, acidentes não relacionados ao medicamento e pacientes propositalmente em regime de sedação. Apesar de valores-limite menos radicais poderem aumentar a ...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to investigate the use of ropivacaine combined or not with different opioids, for epidural anesthesia in bitches submitted to elective ovariosalpingohisterectomy (OSH). Thirty two mixed-breed female dogs, adults were used with medium weigh of 10.5kg. The animals were premedicated with acepromazine (0.05mg.kg-1, IM) and midazolam (0.2mg.kg-1, IM) and allocated in four experimental groups: group 1(n=8): ropivacaine: 0.3 mL.kg-1; group 2(n=8): ropivacaine + morphine (0.1 mg.kg-1); group 3(n=8): ropivacaine + butorphanol (0.1 mg.kg-1); and group 4(n=8): ropivacaine + tramadol (0.5 mg.kg-1) administered epidurally. Heart and respiratory rate; systolic arterial pressure; rectal temperature; arterial blood gas partial pressures; blood pH; sedation and muscular relaxation degree were evaluated at different experimental moments. The data were submitted to ANOVA and compared by Kruskal Wallis, Friedman, Dunn, Tukey and Chi-square test (p≤0.05). Minimum cardiorespiratory alterations were observed and the group of the ropivacaíne combined with the butorphanol (G3) presented a more cranial blockage, what allowed the accomplishment of OSH without induction in six animals (75%) whereas most of the others needed anesthetic rescue. The results allow us to conclude that the use of ropivacaine sole or combinated with morphine, butorphanol or tramadol, for epidural anesthesia, didn't promote significant cardiorrespiratory depression and the ropivacaine associated to the butorphanol allowed the accomplishment of OSH in bitches.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Avaliaram-se, durante 60 minutos, 10 bovinos após administração intravenosa de 0,1mg.kg-1 de xilazina ou 10μg.kg-1 de detomidina, quanto às frequências cardíaca e respiratória, movimentos ruminais, pressão arterial média, temperatura retal e respostas comportamentais como ataxia ou decúbito, ptose palpebral, estado de alerta ou sedação e redução da altura da cabeça em relação ao solo, além da presença de salivação, micção e concentração sanguínea de glicose. Observou-se que a xilazina, via intravenosa, em bovinos, ao mesmo tempo que promove sedação mais intensa e prolongada que a detomidina, induz a uma maior quantidade de efeitos indesejáveis, como salivação e decúbito, e redução das frequências cardíaca e respiratória, da pressão arterial média, da motilidade ruminal e da temperatura, sendo estas alterações mais prolongadas. Conclui-se que a detomidina pode ser utilizada com segurança em bovinos na dose de 10μg.kg-1, promovendo sedação e permanência do animal em posição quadrupedal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA, punção aspirativa por agulha guiada por ultrassom endobrônquico) é um método novo em diagnóstico e estadiamento linfonodal mediastinal. O objetivo do estudo foi avaliar os resultados preliminares obtidos com EBUS-TBNA no diagnóstico de lesões e no estadiamento linfonodal mediastinal. MÉTODOS: Foram avaliados pacientes com tumores ou adenopatias mediastinais e com diagnóstico ou suspeita de câncer de pulmão. Os procedimentos foram realizados com os pacientes sob sedação ou anestesia geral. O material coletado foi preparado em lâminas fixadas em álcool absoluto para citologia e em formol para bloco de células. RESULTADOS: Foram incluídos 50 pacientes (30 do sexo masculino), com média de idade de 58,3 ± 13,5 anos. Foram realizadas 201 punções em 81 linfonodos ou massas mediastinais (média de 2,5 punções). O material obtido foi considerado adequado para análise citológica em 37 pacientes (74%), dos quais 21 (57%) foram diagnosticados com malignidade. Nos 16 pacientes remanescentes, 1 teve diagnóstico de tuberculose, 6 tiveram seguimento clínico, e 9 foram submetidos a investigação adicional (2 diagnosticados com neoplasia - resultados falso-negativos). O rendimento do exame foi maior nos procedimentos com objetivo diagnóstico, em pacientes com lesões em múltiplas estações, e nas punções da estação linfonodal subcarinal. Um paciente apresentou sangramento endobrônquico resolvido com medidas locais. Não houve mortalidade na série. CONCLUSÕES: Esta experiência preliminar confirmou que o EBUS-TBNA é procedimento seguro, e que o nosso rendimento diagnóstico, inferior ao da literatura, foi compatível com a curva de aprendizado do método.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

JUSTIFICATIVA E OBJETIVOS: A circulação extracorpórea (CEC) pode alterar a farmacocinética dos fármacos, assim como a função cerebral. Os objetivos deste estudo foram comparar o tempo de despertar e a intensidade da sedação pós-operatória avaliada pelo índice bispectral (BIS) e pela escala de sedação de Ramsay, em pacientes submetidos à revascularização miocárdica (RM) com ou sem CEC. MÉTODO: Dez pacientes submetidos à RM com CEC (Grupo CEC) e 10 sem CEC (Grupo sem CEC) foram anestesiados com sufentanil, infusão alvo-controlada de propofol 2,0 µg.mL-1 e pancuronio. Após a cirurgia diminuiu-se a infusão de propofol para 1 µg.mL-1 que foi suspensa quando da indicação da extubação. Foram avaliados o BIS, a escala de Ramsay e o tempo de despertar dos pacientes. RESULTADOS: O grupo CEC apresentou valores menores de BIS desde 60 minutos após a cirurgia (sem CEC = 66 ± 13 e CEC = 53 ± 14, p = 0,01) até 120 minutos após a infusão (sem CEC = 85 ± 8 e CEC = 73 ± 12, p = 0,02). O nível de sedação pela escala de Ramsay foi maior no grupo CEC nos momentos 30 minutos após o final da cirurgia (sem CEC = 5 ± 1 e CEC = 6 ± 0, p = 0,021), no final da infusão (sem CEC = 5 ± 1 e CEC = 6 ± 1, p = 0,012) e 5 minutos após o final da infusão (sem CEC = 4 ± 1 e CEC = 5 ± 0,42, p = 0,039). O tempo de despertar foi maior no grupo CEC (sem CEC = 217 ± 81 e CEC = 319 ± 118, p = 0,038). CONCLUSÕES: Houve maior intensidade da sedação após o final da cirurgia e o maior tempo de despertar no grupo com CEC, sugerindo alteração na farmacocinética do propofol ou efeitos da CEC sobre o sistema nervoso central.