991 resultados para Saturation Impulse


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite rapid to-and-fro motion of the retinal image that results from their incessant involuntary eye movements, persons with infantile nystagmus (IN) rarely report the perception of motion smear. We performed two experiments to determine if the reduction of perceived motion smear in persons with IN is associated with an increase in the speed of the temporal impulse response. In Experiment 1, increment thresholds were determined for pairs of successively presented flashes of a long horizontal line, presented on a 65-cd/m2 background field. The stimulus-onset asynchrony (SOA) between the first and second flash varied from 5.9 to 234 ms. In experiment 2, temporal contrast sensitivity functions were determined for a 3-cpd horizontal square-wave grating that underwent counterphase flicker at temporal frequencies between 1 and 40 Hz. Data were obtained for 2 subjects with predominantly pendular IN and 8 normal observers in Experiment 1 and for 3 subjects with IN and 4 normal observers in Experiment 2. Temporal impulse response functions (TIRFs) were estimated as the impulse response of a linear second-order system that provided the best fit to the increment threshold data in Experiment 1 and to the temporal contrast sensitivity functions in Experiment 2. Estimated TIRFs of the subjects with pendular IN have natural temporal frequencies that are significantly faster than those of normal observers (ca. 13 vs. 9 Hz), indicating an accelerated temporal response to visual stimuli. This increase in response speed is too small to account by itself for the virtual absence of perceived motion smear in subjects with IN, and additional neural mechanisms are considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Im vorliegenden Beitrag wird versucht, den [Lehr-Lern-Prozess] in Hinblick auf individualisierten Unterricht genauer zu klären und auf die aktuelle Diskussion zur wirksamen Implementierung von Bildungsstandards zu beziehen. Dabei wird ein lehr-lerntheoretisches Modell dargestellt, das Orientierungshilfen für die lern-wirksame Gestaltung von unterrichtlichen Prozessen bieten soll. Es wird im Weiteren auf die folgenden Qualitätsmerkmale guten Unterrichts bezogen: das Fördern einer positiven Lernatmosphäre, das Herstellen einer (bildungsstandardbezogenen) Zielorientierung und die Berücksichtigung von Lernvoraussetzungen durch pädagogische Diagnostik, die mit aufgabenbasierten und protokollierten Lernförderungskreisläufen gekoppelt ist. Abschließend werden Anwendungsmöglichkeiten dieses Modells insbesondere in der Unterrichtsgestaltung und -evaluation kurz aufgezeigt und kritisch diskutiert.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In an article in the December 2012 issue of The Journal of Trauma and Acute Care Surgery, several author names were misprinted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

(31)P MRS magnetization transfer ((31)P-MT) experiments allow the estimation of exchange rates of biochemical reactions, such as the creatine kinase equilibrium and adenosine triphosphate (ATP) synthesis. Although various (31)P-MT methods have been successfully used on isolated organs or animals, their application on humans in clinical scanners poses specific challenges. This study compared two major (31)P-MT methods on a clinical MR system using heteronuclear surface coils. Although saturation transfer (ST) is the most commonly used (31)P-MT method, sequences such as inversion transfer (IT) with short pulses might be better suited for the specific hardware and software limitations of a clinical scanner. In addition, small NMR-undetectable metabolite pools can transfer MT to NMR-visible pools during long saturation pulses, which is prevented with short pulses. (31)P-MT sequences were adapted for limited pulse length, for heteronuclear transmit-receive surface coils with inhomogeneous B1 , for the need for volume selection and for the inherently low signal-to-noise ratio (SNR) on a clinical 3-T MR system. The ST and IT sequences were applied to skeletal muscle and liver in 10 healthy volunteers. Monte-Carlo simulations were used to evaluate the behavior of the IT measurements with increasing imperfections. In skeletal muscle of the thigh, ATP synthesis resulted in forward reaction constants (k) of 0.074 ± 0.022 s(-1) (ST) and 0.137 ± 0.042 s(-1) (IT), whereas the creatine kinase reaction yielded 0.459 ± 0.089 s(-1) (IT). In the liver, ATP synthesis resulted in k = 0.267 ± 0.106 s(-1) (ST), whereas the IT experiment yielded no consistent results. ST results were close to literature values; however, the IT results were either much larger than the corresponding ST values and/or were widely scattered. To summarize, ST and IT experiments can both be implemented on a clinical body scanner with heteronuclear transmit-receive surface coils; however, ST results are much more robust against experimental imperfections than the current implementation of IT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We explore the feasibility of obtaining a spatially resolved picture of Ca2+Ca2+ inward currents (ICaICa) in multicellular cardiac tissue by differentiating optically recorded Ca2+Ca2+ transients that accompany propagating action potentials. Patterned growth strands of neonatal rat ventricular cardiomyocytes were stained with the Ca2+Ca2+ indicators Fluo-4 or Fluo-4FF. Preparations were stimulated at 1 Hz, and Ca2+Ca2+ transients were recorded with high spatiotemporal resolution (50  μm50  μm, 2 kHz analog bandwidth) with a photodiode array. Signals were differentiated after appropriate digital filtering. Differentiation of Ca2+Ca2+ transients resulted in optically recorded calcium currents (ORCCs) that carried the temporal and pharmacological signatures of L-type Ca2+Ca2+ inward currents: the time to peak amounted to ∼2.1  ms∼2.1  ms (Fluo-4FF) and ∼2.4  ms∼2.4  ms (Fluo-4), full-width at half-maximum was ∼8  ms∼8  ms, and ORCCs were completely suppressed by 50  μmol/L50  μmol/LCdCl2CdCl2. Also, and as reported before from patch-clamp studies, caffeine reversibly depressed the amplitude of ORCCs. The results demonstrate that the differentiation of Ca2+Ca2+ transients can be used to obtain a spatially resolved picture of the initial phase of ICaICa in cardiac tissue and to assess relative changes of activation/fast inactivation of ICaICa following pharmacological interventions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to test the effects of a sustained nystagmus on the head impulse response of the vestibulo-ocular reflex (VOR) in healthy subjects. VOR gain (slow-phase eye velocity/head velocity) was measured using video head impulse test goggles. Acting as a surrogate for a spontaneous nystagmus (SN), a post-rotatory nystagmus (PRN) was elicited after a sustained, constant-velocity rotation, and then head impulses were applied. 'Raw' VOR gain, uncorrected for PRN, in healthy subjects in response to head impulses with peak velocities in the range of 150°/s-250°/s was significantly increased (as reflected in an increase in the slope of the gain versus head velocity relationship) after inducing PRN with slow phases of nystagmus of high intensity (>30°/s) in the same but not in the opposite direction as the slow-phase response induced by the head impulses. The values of VOR gain themselves, however, remained in the normal range with slow-phase velocities of PRN < 30°/s. Finally, quick phases of PRN were suppressed during the first 20-160 ms of a head impulse; the time frame of suppression depended on the direction of PRN but not on the duration of the head impulse. Our results in normal subjects suggest that VOR gains measured using head impulses may have to be corrected for any superimposed SN when the slow-phase velocity of nystagmus is relatively high and the peak velocity of the head movements is relatively low. The suppression of quick phases during head impulses may help to improve steady fixation during rapid head movements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The head impulse test (HIT) can identify a deficient vestibulo-ocular reflex (VOR) by the compensatory saccade (CS) generated once the head stops moving. The inward HIT is considered safer than the outward HIT, yet might have an oculomotor advantage given that the subject would presumably know the direction of head rotation. Here, we compare CS latencies following inward (presumed predictable) and outward (more unpredictable) HITs after acute unilateral vestibular nerve deafferentation. Seven patients received inward and outward HITs delivered at six consecutive postoperative days (POD) and again at POD 30. All head impulses were recorded by portable video-oculography. CS included those occurring during (covert) or after (overt) head rotation. Inward HITs included mean CS latencies (183.48 ms ± 4.47 SE) that were consistently shorter than those generated during outward HITs in the first 6 POD (p = 0.0033). Inward HITs induced more covert saccades compared to outward HITs, acutely. However, by POD 30 there were no longer any differences in latencies or proportions of CS and direction of head rotation. Patients with acute unilateral vestibular loss likely use predictive cues of head direction to elicit early CS to keep the image centered on the fovea. In acute vestibular hypofunction, inwardly applied HITs may risk a preponderance of covert saccades, yet this difference largely disappears within 30 days. Advantages of inwardly applied HITs are discussed and must be balanced against the risk of a false-negative HIT interpretation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE Vestibular neuritis is often mimicked by stroke (pseudoneuritis). Vestibular eye movements help discriminate the two conditions. We report vestibulo-ocular reflex (VOR) gain measures in neuritis and stroke presenting acute vestibular syndrome (AVS). METHODS Prospective cross-sectional study of AVS (acute continuous vertigo/dizziness lasting >24 h) at two academic centers. We measured horizontal head impulse test (HIT) VOR gains in 26 AVS patients using a video HIT device (ICS Impulse). All patients were assessed within 1 week of symptom onset. Diagnoses were confirmed by clinical examinations, brain magnetic resonance imaging with diffusion-weighted images, and follow-up. Brainstem and cerebellar strokes were classified by vascular territory-posterior inferior cerebellar artery (PICA) or anterior inferior cerebellar artery (AICA). RESULTS Diagnoses were vestibular neuritis (n = 16) and posterior fossa stroke (PICA, n = 7; AICA, n = 3). Mean HIT VOR gains (ipsilesional [standard error of the mean], contralesional [standard error of the mean]) were as follows: vestibular neuritis (0.52 [0.04], 0.87 [0.04]); PICA stroke (0.94 [0.04], 0.93 [0.04]); AICA stroke (0.84 [0.10], 0.74 [0.10]). VOR gains were asymmetric in neuritis (unilateral vestibulopathy) and symmetric in PICA stroke (bilaterally normal VOR), whereas gains in AICA stroke were heterogeneous (asymmetric, bilaterally low, or normal). In vestibular neuritis, borderline gains ranged from 0.62 to 0.73. Twenty patients (12 neuritis, six PICA strokes, two AICA strokes) had at least five interpretable HIT trials (for both ears), allowing an appropriate classification based on mean VOR gains per ear. Classifying AVS patients with bilateral VOR mean gains of 0.70 or more as suspected strokes yielded a total diagnostic accuracy of 90%, with stroke sensitivity of 88% and specificity of 92%. CONCLUSION Video HIT VOR gains differ between peripheral and central causes of AVS. PICA strokes were readily separated from neuritis using gain measures, but AICA strokes were at risk of being misclassified based on VOR gain alone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To investigate whether nonhemodynamic resonant saturation effects can be detected in patients with focal epilepsy by using a phase-cycled stimulus-induced rotary saturation (PC-SIRS) approach with spin-lock (SL) preparation and whether they colocalize with the seizure onset zone and surface interictal epileptiform discharges (IED). Materials and Methods The study was approved by the local ethics committee, and all subjects gave written informed consent. Eight patients with focal epilepsy undergoing presurgical surface and intracranial electroencephalography (EEG) underwent magnetic resonance (MR) imaging at 3 T with a whole-brain PC-SIRS imaging sequence with alternating SL-on and SL-off and two-dimensional echo-planar readout. The power of the SL radiofrequency pulse was set to 120 Hz to sensitize the sequence to high gamma oscillations present in epileptogenic tissue. Phase cycling was applied to capture distributed current orientations. Voxel-wise subtraction of SL-off from SL-on images enabled the separation of T2* effects from rotary saturation effects. The topography of PC-SIRS effects was compared with the seizure onset zone at intracranial EEG and with surface IED-related potentials. Bayesian statistics were used to test whether prior PC-SIRS information could improve IED source reconstruction. Results Nonhemodynamic resonant saturation effects ipsilateral to the seizure onset zone were detected in six of eight patients (concordance rate, 0.75; 95% confidence interval: 0.40, 0.94) by means of the PC-SIRS technique. They were concordant with IED surface negativity in seven of eight patients (0.88; 95% confidence interval: 0.51, 1.00). Including PC-SIRS as prior information improved the evidence of the standard EEG source models compared with the use of uninformed reconstructions (exceedance probability, 0.77 vs 0.12; Wilcoxon test of model evidence, P < .05). Nonhemodynamic resonant saturation effects resolved in patients with favorable postsurgical outcomes, but persisted in patients with postsurgical seizure recurrence. Conclusion Nonhemodynamic resonant saturation effects are detectable during interictal periods with the PC-SIRS approach in patients with epilepsy. The method may be useful for MR imaging-based detection of neuronal currents in a clinical environment. (©) RSNA, 2016 Online supplemental material is available for this article.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Changes in the dissolved oxygen content, the alkalinity, and the pH in sea water near the ocean floor are interpreted in terms of chemical and biochemical processes at the sediment water interface. A simple model provides a plausible explanation of the observed phenomena. Special emphasis is given to the importance of borate corrections in the calculation of the solution effects of calcium carbonate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Four species of planktic foraminifera from core-tops spanning a depth transect on the Ontong Java Plateau were prepared for Mg/Ca analysis both with (Cd-cleaning) and without (Mg-cleaning) a reductive cleaning step. Reductive cleaning caused etching of foraminiferal calcite, focused on Mg-rich inner calcite, even on tests which had already been partially dissolved at the seafloor. Despite corrosion, there was no difference in Mg/Ca of Pulleniatina obliquiloculata between cleaning methods. Reductive cleaning decreased Mg/Ca by an average (all depths) of ~ 4% for Globigerinoides ruber white and ~ 10% for Neogloboquadrina dutertrei. Mg/Ca of Globigerinoides sacculifer (above the calcite saturation horizon only) was 5% lower after reductive cleaning. The decrease in Mg/Ca due to reductive cleaning appeared insensitive to preservation state for G. ruber, N. dutertrei and P. obliquiloculata. Mg/Ca of Cd-cleaned G. sacculifer appeared less sensitive to dissolution than that of Mg-cleaned. Mg-cleaning is adequate, but SEM and contaminants (Al/Ca, Fe/Ca and Mn/Ca) show that Cd-cleaning is more effective for porous species. A second aspect of the study addressed sample loss during cleaning. Lower yield after Cd-cleaning for G. ruber, G. sacculifer and N. dutertrei confirmed this to be the more aggressive method. Strongest correlations between yield and Delta[CO3^2-] in core-top samples were for Cd-cleaned G. ruber (r = 0.88, p = 0.020) and Cd-cleaned P. obliquiloculata (r = 0.68, p = 0.030). In a down-core record (WIND28K) correlation, r, between yield values > 30% and dissolution index, XDX, was -0.61 (p = 0.002). Where cleaning yield < 30% most Mg-cleaned Mg/Ca values were biased by dissolution.