983 resultados para SLEEP-APNEA SYNDROME
Resumo:
We present a novel approach for detecting severe obstructive sleep apnea (OSA) cases by introducing non-linear analysis into sustained speech characterization. The proposed scheme was designed for providing additional information into our baseline system, built on top of state-of-the-art cepstral domain modeling techniques, aiming to improve accuracy rates. This new information is lightly correlated with our previous MFCC modeling of sustained speech and uncorrelated with the information in our continuous speech modeling scheme. Tests have been performed to evaluate the improvement for our detection task, based on sustained speech as well as combined with a continuous speech classifier, resulting in a 10% relative reduction in classification for the first and a 33% relative reduction for the fused scheme. Results encourage us to consider the existence of non-linear effects on OSA patients' voices, and to think about tools which could be used to improve short-time analysis.
Resumo:
We present a novel approach for the detection of severe obstructive sleep apnea (OSA) based on patients' voices introducing nonlinear measures to describe sustained speech dynamics. Nonlinear features were combined with state-of-the-art speech recognition systems using statistical modeling techniques (Gaussian mixture models, GMMs) over cepstral parameterization (MFCC) for both continuous and sustained speech. Tests were performed on a database including speech records from both severe OSA and control speakers. A 10 % relative reduction in classification error was obtained for sustained speech when combining MFCC-GMM and nonlinear features, and 33 % when fusing nonlinear features with both sustained and continuous MFCC-GMM. Accuracy reached 88.5 % allowing the system to be used in OSA early detection. Tests showed that nonlinear features and MFCCs are lightly correlated on sustained speech, but uncorrelated on continuous speech. Results also suggest the existence of nonlinear effects in OSA patients' voices, which should be found in continuous speech.
Resumo:
Automatic systems based on speech signal analysis for the early dete ction of obstructive sleep apnea (OSA) have achieved fairly high performance rates in recent years. However, a satisfactory explanation of these results has not been available. This presentation aims at explaining via an examination of the long-term spectra of OSA patients and normal control speakers these systems’ ability to discover OSA speakers on the base of all-purpose cepstral coefficients. An in terpretation of the long- term spectra in terms of the underlying tract settings suggests that the speech of OSA patients is characterized by a pharyngeal narrowing that may be captured by acoustic cues of the spectral contour of windowed speech frames. A novel interpretation of long-term spectra in terms of the first principal component of the temporal sequence of short-term amplitude-spectra is also discussed.
Resumo:
The aim of automatic pathological voice detection systems is to serve as tools, to medical specialists, for a more objective, less invasive and improved diagnosis of diseases. In this respect, the gold standard for those system include the usage of a optimized representation of the spectral envelope, either based on cepstral coefficients from the mel-scaled Fourier spectral envelope (Mel-Frequency Cepstral Coefficients) or from an all-pole estimation (Linear Prediction Coding Cepstral Coefficients) forcharacterization, and Gaussian Mixture Models for posterior classification. However, the study of recently proposed GMM-based classifiers as well as Nuisance mitigation techniques, such as those employed in speaker recognition, has not been widely considered inpathology detection labours. The present work aims at testing whether or not the employment of such speaker recognition tools might contribute to improve system performance in pathology detection systems, specifically in the automatic detection of Obstructive Sleep Apnea. The testing procedure employs an Obstructive Sleep Apnea database, in conjunction with GMM-based classifiers looking for a better performance. The results show that an improved performance might be obtained by using such approach.
Resumo:
Sleep-disordered breathing and excessive sleepiness may be more common in commercial vehicle drivers than in the general population. The relative importance of factors causing excessive sleepiness and accidents in this population remains unclear. We measured the prevalence of excessive sleepiness and sleep-disordered breathing and assessed accident risk factors in 2,342 respondents to a questionnaire distributed to a random sample of 3,268 Australian commercial vehicle drivers and another 161 drivers among 244 invited to undergo polysomnography. More than half (59.6%) of drivers had sleep-disordered breathing and 15.8% had obstructive sleep apnea syndrome. Twenty-four percent of drivers had excessive sleepiness. Increasing sleepiness was related to an increased accident risk. The sleepiest 5% of drivers on the Epworth Sleepiness Scale and Functional Outcomes of Sleep Questionnaire had an in-creased risk of an accident (odds ratio [OR] 1.91, p = 0.02 and OR 2.23, p < 0.01, respectively) and multiple accidents (OR 2.67, p < 0.01 and OR 2.39, p = 0.01), adjusted for established risk factors. There was an increased accident risk with narcotic analgesic use (OR 2.40, p < 0.01) and antihistamine use (OR 3.44, p = 0.04). Chronic excessive sleepiness and sleep-disordered breathing are common in Australian commercial vehicle drivers. Accident risk was related to increasing chronic sleepiness and antihistamine and narcotic analgesic use.
Resumo:
In the present study, multilayer perceptron (MLP) neural networks were applied to help in the diagnosis of obstructive sleep apnoea syndrome (OSAS). Oxygen saturation (SaO2) recordings from nocturnal pulse oximetry were used for this purpose. We performed time and spectral analysis of these signals to extract 14 features related to OSAS. The performance of two different MLP classifiers was compared: maximum likelihood (ML) and Bayesian (BY) MLP networks. A total of 187 subjects suspected of suffering from OSAS took part in the study. Their SaO2 signals were divided into a training set with 74 recordings and a test set with 113 recordings. BY-MLP networks achieved the best performance on the test set with 85.58% accuracy (87.76% sensitivity and 82.39% specificity). These results were substantially better than those provided by ML-MLP networks, which were affected by overfitting and achieved an accuracy of 76.81% (86.42% sensitivity and 62.83% specificity). Our results suggest that the Bayesian framework is preferred to implement our MLP classifiers. The proposed BY-MLP networks could be used for early OSAS detection. They could contribute to overcome the difficulties of nocturnal polysomnography (PSG) and thus reduce the demand for these studies.
Resumo:
The relationship between sleep apnoea–hypopnoea syndrome (SAHS) severity and the regularity of nocturnal oxygen saturation (SaO2) recordings was analysed. Three different methods were proposed to quantify regularity: approximate entropy (AEn), sample entropy (SEn) and kernel entropy (KEn). A total of 240 subjects suspected of suffering from SAHS took part in the study. They were randomly divided into a training set (96 subjects) and a test set (144 subjects) for the adjustment and assessment of the proposed methods, respectively. According to the measurements provided by AEn, SEn and KEn, higher irregularity of oximetry signals is associated with SAHS-positive patients. Receiver operating characteristic (ROC) and Pearson correlation analyses showed that KEn was the most reliable predictor of SAHS. It provided an area under the ROC curve of 0.91 in two-class classification of subjects as SAHS-negative or SAHS-positive. Moreover, KEn measurements from oximetry data exhibited a linear dependence on the apnoea–hypopnoea index, as shown by a correlation coefficient of 0.87. Therefore, these measurements could be used for the development of simplified diagnostic techniques in order to reduce the demand for polysomnographies. Furthermore, KEn represents a convincing alternative to AEn and SEn for the diagnostic analysis of noisy biomedical signals.