956 resultados para SALIVARY FLOW-RATE
Resumo:
BACKGROUND: A packed bed bioreactor (PBBR) activated with an indigenous nitrifying bacterial consortia was developed and commercialized for rapid establishment of nitrification in brackish water and marine hatchery systems in the tropics. The present study evaluated nitrification in PBBR integrated into a Penaeus monodon recirculating maturation system under different substrate concentrations and flow rates. RESULTS:Instantnitrificationwasobservedafter integration ofPBBRinto thematuration system.TANandNO2-Nconcentrations were always maintained below0.5 mg L−1 during operation. The TANandNO2-N removalwas significant (P < 0.001) in all the six reactor compartments of the PBBR having the substrates at initial concentrations of 2, 5 and 10 mg L−1. The average volumetric TAN removal rates increased with flow rates from 43.51 (250 L h−1) to 130.44 (2500 L h−1) gTAN m−3 day−1 (P < 0.05). FISH analysis of the biofilms after 70 days of operation gave positive results with probes NSO 190 ((β ammonia oxidizers), NsV 443 (Nitrosospira spp.) NEU (halophilic Nitrosomonas), Ntspa 712 (Phylum Nitrospira) indicating stability of the consortia. CONCLUSION: The PBBR integrated into the P. monodon maturation system exhibited significant nitrification upon operation for 70 days as well as at different substrate concentrations and flow rates. This system can easily be integrated into marine and brackish water aquaculture systems, to establish instantaneous nitrification
Resumo:
Electroosmotic flow is a convenient mechanism for transporting polar fluid in a microfluidic device. The flow is generated through the application of an external electric field that acts on the free charges that exists in a thin Debye layer at the channel walls. The charge on the wall is due to the chemistry of the solid-fluid interface, and it can vary along the channel, e.g. due to modification of the wall. This investigation focuses on the simulation of the electroosmotic flow (EOF) profile in a cylindrical microchannel with step change in zeta potential. The modified Navier-Stoke equation governing the velocity field and a non-linear two-dimensional Poisson-Boltzmann equation governing the electrical double-layer (EDL) field distribution are solved numerically using finite control-volume method. Continuities of flow rate and electric current are enforced resulting in a non-uniform electrical field and pressure gradient distribution along the channel. The resulting parabolic velocity distribution at the junction of the step change in zeta potential, which is more typical of a pressure-driven velocity flow profile, is obtained.
Resumo:
We report the first systematic study on the photocatalytic oxidation of humic acid (HA) in artificial seawater (ASW). TiO2 (Degussa P25) dispersions were used as the catalyst with irradiation from a medium-pressure mercury lamp. The optimum quantity of catalyst was found to be between 2 and 2.5 g l(-1); whiled the decomposition was fastest at low pH values (pH 4.5 in the range examined), and the optimum air-flow, using an immersion well reactor with a capacity of 400 ml, was 850 ml min(-1). Reactivity increased with air-flow up to this figure, above which foaming prevented operation of the reactor. Using pure. oxygen, an optimal flow rate was observed at 300 nil min(-1), above which reactivity remains essentially constant. Following treatment for 1 h, low-salinity water (2700 mg l(-1)) was completely mineralised, whereas ASW (46000 mg l(-1)) had traces of HA remaining. These effects are interpreted and kinetic data presented. To avoid problems of precipitation due to change of ionic strength humic substances were prepared directly in ASW, and the effects of ASW on catalyst suspension and precipitation have been taken into account. The Langmuir-Hinshelwood kinetic model has been shown to be followed only approximately for the catalytic oxidation of HA in ASW. The activation energy for the reaction derived from an Arrhenius treatment was 17 ( +/-0.6) kJ mol(-1). (C) 2003 Elsevier Science Ltd. All rights reserved.
Resumo:
We report on the capillary flow behaviour of thermotropic liquid crystal mixtures containing 4-n-octyl-4'-cyanobiphenyl (8CB) and 4-n-pentyl-4'-cyanobiphenyl (5CB). The liquid crystal mixtures are studied in the Nematic (N) and Smectic (SA) phases at room temperature. Polarised optical microscopy (POM), rheology and simultaneous X-ray diffraction (XRD)/capillary flow experiments are performed to characterise the system. Polarised optical microscopy reveals a dramatic change in optical texture when the 5CB content is increased from 20 to 30% in the mixtures. X-ray diffraction results show that the system goes through a SA-N phase transition, such that the mixtures are smectic for 10-20% 5CB and nematic for 30-90% 5CB. Smectic mixtures flow with the layers aligned along the flow direction (mesogens perpendicular to flow) while nematic mixtures flow with the mesogens aligned in the flow direction. Simultaneous XRD/shear flow experiments show that the SA-N transition is independent of the flow rate in the range 1-6 ml min-1. The correlation length of the liquid crystal order decreases with increasing 5CB content. Rheology is used to prove that the correlation length behaviour is related to a reduction in the viscosity of the mixture.
Resumo:
This paper provides a comparative study of the performance of cross-flow and counter-flow M-cycle heat exchangers for dew point cooling. It is recognised that evaporative cooling systems offer a low energy alternative to conventional air conditioning units. Recently emerged dew point cooling, as the renovated evaporative cooling configuration, is claimed to have much higher cooling output over the conventional evaporative modes owing to use of the M-cycle heat exchangers. Cross-flow and counter-flow heat exchangers, as the available structures for M-cycle dew point cooling processing, were theoretically and experimentally investigated to identify the difference in cooling effectiveness of both under the parallel structural/operational conditions, optimise the geometrical sizes of the exchangers and suggest their favourite operational conditions. Through development of a dedicated computer model and case-by-case experimental testing and validation, a parametric study of the cooling performance of the counter-flow and cross-flow heat exchangers was carried out. The results showed the counter-flow exchanger offered greater (around 20% higher) cooling capacity, as well as greater (15%–23% higher) dew-point and wet-bulb effectiveness when equal in physical size and under the same operating conditions. The cross-flow system, however, had a greater (10% higher) Energy Efficiency (COP). As the increased cooling effectiveness will lead to reduced air volume flow rate, smaller system size and lower cost, whilst the size and cost are the inherent barriers for use of dew point cooling as the alternation of the conventional cooling systems, the counter-flow system is considered to offer practical advantages over the cross-flow system that would aid the uptake of this low energy cooling alternative. In line with increased global demand for energy in cooling of building, largely by economic booming of emerging developing nations and recognised global warming, the research results will be of significant importance in terms of promoting deployment of the low energy dew point cooling system, helping reduction of energy use in cooling of buildings and cut of the associated carbon emission.
Resumo:
This study attempts to fill the existing gap in the simulation of variable flow distribution systems through developing new pressure governing components. These components are able to capture the actual ever-changing system performance curve in variable flow distribution systems together with the prediction of controversial issues such as starving, over-flow and the lack of controllability on the flow rate of different branches in a hydronic system. The performance of the proposed components is verified using a case study under design and off-design circumstances. Full integration of the new components within the TRNSYS simulation package is another advantage of this study, which makes it more applicable for designers in both the design and commissioning of hydronic systems.
Resumo:
A novel approach was developed for nitrate analysis in a FIA configuration with amperometric detection (E=-0.48 V). Sensitive and reproducible current measurements were achieved by using a copper electrode activated with a controlled potential protocol. The response of the FIA amperometric method was linear over the range from 0.1 to 2.5 mmol L(-1) nitrate with a detection limit of 4.2 mu mol L(-1) (S/N = 3). The repeatability of measurements was determined as 4.7% (n=9) at the best conditions (flow rate: 3.0 mL min(-1), sample volume: 150 mu L and nitrate concentration: 0.5 mmol L(-1)) with a sampling rate of 60 samples h(-1). The method was employed for the determination of nitrate in mineral water and soft drink samples and the results were in agreement with those obtained by using a recommended procedure. Studies towards a selective monitoring of nitrite were also performed in samples containing nitrate by carrying out measurements at a less negative potential (-0.20 V). (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
The physical and chemical characteristics of peat were assessed through measurement of pH, percentage of organic matter, cationic exchange capacity (CEC), elemental analysis, infrared spectroscopy and quantitative analysis of metals by ICP OES. Despite the material showed to be very acid in view of the percentage of organic matter, its CEC was significant, showing potential for retention of metal ions. This characteristic was exploited by coupling a peat mini-column to a flow system based on the multicommutation approach for the in-line copper concentration prior to flame atomic absorption spectrometric determination. Cu(II) ions were adsorbed at pH 4.5 and eluted with 0.50 mol L(-1) HNO(3). The influence of chemical and hydrodynamic parameters, such as sample pH, buffer concentration, eluent type and concentration, sample flow-rate and preconcentration time were investigated. Under the optimized conditions, a linear response was observed between 16 and 100 mu g L(-1), with a detection limit estimated as 3 mu g L(-1) at the 99.7% confidence level and an enrichment factor of 16. The relative standard deviation was estimated as 3.3% (n = 20). The mini-column was used for at least 100 sampling cycles without significant variation in the analytical response. Recoveries from copper spiked to lake water or groundwater as well as concentrates used in hemodialysis were in the 97.3-111 % range. The results obtained for copper determination in these samples agreed with those achieved by graphite furnace atomic absorption spectrometry (GFAAS) at the 95% confidence level. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Flow injection analysis (FIA) using a carbon film sensor for amperometric detection was explored for ambroxol analysis in pharmaceutical formulations. The specially designed flow cell designed in the lab generated sharp and reproducible current peaks, with a wide linear dynamic range from 5 x 10(-7) to 3.5 x 10(-4) mol L-1, in 0.1 mol L-1 sulfuric acid electrolyte, as well as high sensitivity, 0.110 A mol(-1) L cm(-2) at the optimized flow rate. A detection limit of 7.6 x 10(-8) mol L-1 and a sampling frequency of 50 determinations per hour were achieved, employing injected volumes of 100 mu L and a flow rate of 2.0 mL min(-1). The repeatability, expressed as R.S.D. for successive and alternated injections of 6.0 x 10(-6) and 6.0 x 10(-5) mol L-1 ambroxol solutions, was 3.0 and 1.5%, respectively, without any noticeable memory effect between injections. The proposed method was applied to the analysis of ambroxol in pharmaceutical samples and the results obtained were compared with UV spectrophotometric and acid-base titrimetric methods. Good agreement between the results utilizing the three methods and the labeled values was achieved, corroborating the good performance of the proposed electrochemical methodology for ambroxol analysis. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
Objetivo: o objetivo deste estudo foi avaliar as condições de saúde bucal e a ocorrência de anomalias dentárias em crianças tratadas para leucemia linfoblástica aguda (LLA) no Serviço de Oncologia Pediátrica (SOP) do Hospital de Clínicas de Porto Alegre (HCPA), comparadas com um grupo crianças saudáveis. Amostra: foram selecionadas 56 crianças com diagnóstico de LLA e analisadas as presenças de anomalias dentárias e os índices CPO-D (cariado, perdido, obturado-dente), IPV (índice de placa visível), ISG (índice de sangramento gengival) e fluxo salivar. As crianças tratadas apresentaram uma média de idade, na época do diagnóstico da LLA, de 5,3 ± 2,6, e 11,8 ± 4,2 na avaliação, sendo 32 masculinos e 24 femininos. Os pacientes tratados para LLA foram divididos em três grupos: crianças tratadas somente com quimioterapia, com quimio e radioterapia, e com quimio, radio e transplante de medula óssea. Resultados: os resultados revelaram 80,4% de anomalias dentárias nas crianças tratadas, ou seja, 45 destas apresentaram pelo menos uma alteração, e o grupo de pacientes tratados com quimio, radio e submetidos ao transplante de medula óssea foi o que revelou a maior média de anormalidades dentárias por indivíduo (15,37 ± 15,03), não ocorrendo diferença estatística entre os gêneros. As crianças tratadas para LLA obtiveram CPO-D de 1,9 ± 4,0, ISG de 26,5%, IPV de 72,0%, e índice de fluxo salivar médio de 0,19 mL/min criança. Já o grupo de crianças sadias apresentou CPO-D de 1,52 ± 3,5, ISG de 11,1%, IPV de 53,8% e índice de fluxo salivar médio de 0,27 mL/min. Conclusão: o tratamento para a cura da LLA provoca um aumento significativo no número de anomalias dentárias, sendo mais freqüente nos pacientes menores de cinco anos de idade, principalmente nos pacientes submetidos a quimio e radioterapia associadas ao transplante de medula óssea, o que requer, por parte do cirurgião-dentista, intervenções clínicas diferenciadas e cuidadosas nestes pacientes, tendo-se em vista também os índices aumentados de ISG e IPV. As alterações sofridas pelas glândulas salivares durante o tratamento não são permanentes sob o aspecto do fluxo salivar, que retorna à normalidade. A orientação e o acompanhamento adequados destes pacientes por parte da equipe de saúde bucal podem mantê-los com o índice de CPO-D dentro dos padrões preconizados pela Organização Mundial de Saúde.
Resumo:
An oxovanadium-salen complex (NAP-ethylene-bis(salicylidenciminato) oxovanadium) thin film deposited on a graphite-polyurethane electrode was investigated with regard to its potential use for detection of L-dopa in flow injection system. The oxovanadium(IV)/oxovanadium(V) redox couple of the modified electrode was found to mediate the L-dopa oxidation before its use in the FIA system. Experimental parameters, such as pH of the carrier solution, flow rate, sample volume injection and probable interferents were investigated. Under the optimized FIA conditions, the amperometric signal was linearly dependent on the L-dopa concentration over the range 1.0 x 10(-1) to 1.0 x 10(-4) mol L-1 (I-anodic, mu A) = 0.01 + 0.25 [L-dopa mu mol L-1]) with a detection limit (S/N = 3) of 8.0 x 10(-7) mol L-1 and a sampling frequency of 90 h(-1) was achieved. For a concentration of 1.0 x 10(-5) mol L-1 L-dopa, the R.S.D. of nine consecutive measurements was 3.7%. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
We have studied the effects of L-NG-nitro arginine methyl esther (L-NAME), L-arginine (LAR), inhibitor and a donating nitric oxide agent on the alterations of salivary flow, water intake, arterial blood pressure (MAP) and heart rate (HR) induced by the injection pilocarpine into the subfornical organ (SFO). Rats (Holtzman 250-300 g) were anesthetized with 2, 2, 2-tribromoethanol (20 mg/100 kg b. wt.) and a stainless steel carmula were implanted into their SFO. The volume of injection was 0.2 mu l. The amount of saliva secretion was studied over a 5-min period. Pilocarpine (40 mu g), L-NAME (40 mu g) and LAR (30 mu g) were used in all experiments for the injection into the SFO. Pilocarpine (10, 20, 40, 80 and 160 mu g) injected into SFO elicited a concentration-dependent increase in salivary secretion. L-NAME injected prior to pilocarpine into the SFO increased salivary secretion and water intake due to the effect of pilocarpine. LAR injected prior to pilocarpine into the SFO attenuated the salivary secretion and water intake. Pilocarpine, injected into the SFO increased the MAP and decreased heart rate (HR). L-NAME injected prior to pilocarpine into the SFO potentiated the pressor effect of pilocarpine with a decrease in HR. LAR injected into the SFO prior to pilocarpine attenuated the increase in MAP with no changes in HR. The present study suggests that the SFO nitrergic cells interfere in the cholinergic pathways implicated in the control of salivary secretion, fluid and cardiovascular homeostasis. (c) 2007 Elsevier B.V All rights reserved.
Resumo:
The aim of this study was to compare microbiological and salivary variables possibly related to caries risk in treated and untreated mouthbreathing syndrome (MBS) children and control children. Thirty control children, 30 mouthbreathers and 25 treated mouthbreathers were studied for the numbers of lactobacilli, mutans streptococci and yeasts in their saliva. Snyder's test, salivary flow and buffering capacity were also evaluated. Levels of immunoglobulins to Candida albicans and Streptococcus mutans in the saliva were quantified using ELISA. Considering the results obtained for the microbiological and salivary caries risk tests, no significant differences were observed among the proportions of patients with small/negative and high/moderate caries risk in the studied groups. The level of IgG to S. mutans was significantly higher in the treated MBS group in relation to MBS patients. on the other hand, the median anti-S. mutans IgM level was lower in the treated MBS patients than in the other groups. For the studied anti-Candida immunoglobulins, IgM level was significantly lower in the treated MBS group than in the other groups. No differences were observed for anti-S. mutans and anti-Candida IgA levels among the groups. The findings suggest that mouthbreathing cannot be considered a risk factor for dental caries. Copyright (C) 2003 S. KargerAG, Basel.