497 resultados para Resinas


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work had with objective to characterize and evaluate the performance of the combined system, involving activated charcoal and ionic exchange resins in the removal of substances organic contaminating of the ethyl alcohol from the fermentation of the cassava starch. To testing was used ethyl alcohol PA 96 oGL, conductivity of 0.90 μS/cm at 25 oC, acidity of 60 mg/L and Barbet test of 43 minutes at 15 oC. The contaminated alcohol was composed of ethyl alcohol additive of higher alcohols, organic acids, ester, diol, aldehydes, ketone and ether. Contaminated alcohol was added 2% activated charcoal and after the adsorption isotherm in ionic exchange resins was tested. The adsorption with activated charcoal was performed in a Water Bath at 30 oC for one hour and a half and shaking. Already adsorption ionic exchange columns occurred at room temperature on columns of 93,4 cm in filling height and diameter of 2.29 cm, for flows of 180 mL/min and 90 mL/min. Samples were collected in the tests with charcoal and with each one of the resins and the following analyses were performed: conductivity, acidity and Barbet test. The medium values for conductivity, acidity and Barbet test after the adsorption in charcoal and cation and anion resins were respectively: conductivity was 240; 354 and 465 μS/cm to 25 oC; acidity of 1.081; 1.103 and 1.062 mg/L and the Barbet test was 21; 20 and 9 minutes to 15 oC. It was observed that the addition of 2% of activated charcoal and the permanence in the columns of adsorption was not sufficient to remove the organic substances contaminating of the ethyl alcohol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Los agentes de fijación a base de resina autoacondicionantes - autoadhesivos (SE/SA) fueron desarrollados con el objetivo de simplificar la técnica de cementado a un solo paso, ahorrando tiempo y errores por parte del operador. El objetivo de este trabajo fue evaluar si dicha simplificación influye negativamente sobre los valores adhesivos tal como sucediera en los sistemas adhesivos a esmalte y dentina autoacondicionantes. Se confeccionaron 20 probetas de dentina en las cuales se cementaron probetas de resina compuesta: 10 muestras fueron cementadas con un cemento de grabado total (TE) y 10 con un cemento SE/SA y conservadas a 37 ºC y 100 % de humedad hasta su ensayo mecánico. Los resultados observados muestran una disminución en la resistencia adhesiva de los cementos SE/SA. Esto se explica por la menor traba micro mecánica generada por la presencia del barro dentinario y por el menor coeficiente de penetración de los monómeros modificados en estos cementos comparados con los cementos de resinas convencionales.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Las propiedades ópticas de las resinas reforzadas resultan de vital importancia para el logro de restauraciones estéticas, sobre todo en lo referente a color y traslucidéz de las mismas, así como el mantenimiento de esas propiedades en función del tiempo. Ellas dependen de la composición del material y de su manipulación (tiempo de aplicación de una radiación electromagnética adecuada y la potencia de la unidad de fotopolimerización). Una de las formas de observar el comportamiento de estos materiales ante una radiación electromagnética, luego de polimerizados, es medir la transmitancia. El objetivo de este trabajo fue comparar la transmitancia de las resinas reforzadas polimerizadas con distintos tiempos de exposición a la fuente lumínica y diferentes potencias de la misma. Para ello se emplearon muestras de un mismo material de iguales dimensiones, divididos en dos grupos. La variable del grupo 1 fue el tiempo de exposición a la luz, mientras que la del grupo 2 fue la potencia de la fuente de fotoactivación. Para observar la transmitancia de las muestras fue empleado un espectrofotómetro UV- visible, que relaciona la transmitancia con diferentes longitudes de onda, permitiéndonos comparar curvas que representan el comportamiento del material. Los resultados que fueron observados muestran las coincidencias de las mencionadas curvas en ambos grupos y entre las muestras del mismo grupo, para las longitudes de onda cercanas a la luz visible, no así para las correspondientes a las ultravioletas. Pasado un mes de almacenamiento de las muestras, se observaron algunas diferencias en las lecturas de las curvas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La operatoria dental actual cuenta con un conocimiento más profundo de las diferentes estructuras dentarias que sumado al gran adelanto tecnológico y científico en la ciencia de los biomateriales; fruto de innumerables investigaciones, nos permiten contar hoy, con una nueva generación de materiales restauradores, lo que hace más crítico y exigente el conocimiento y análisis por parte del profesional, de las técnicas a efectuar, la realización depurada de procedimientos y los biomateriales a utilizar, con el fin de realizar tratamientos que sean biocompatibles, eficientes y de importante longevidad.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diante da evolução da composição das resinas compostas e do lançamento de compósitos do tipo bulk fill, faz-se necessário o estudo do desempenho dessa nova classe de materiais. Para isso, o presente estudo teve como objetivo avaliar propriedades como grau de conversão (GC) , dureza Knoop (KHN), resistência à flexão (RF) e tenacidade à fratura (KIC) de sete compósitos bulk fill (EverX Posterior, EXP; Filtek Bulk Fill Flow, FBFF; Fill-Up!, FU; SonicFill, SF; Surefil SDR, SDR; Tetric EvoCeram Bulk Fill, TECBF; Venus Bulk Fill, VBF) e um compósito nanohíbrido convencional (Charisma Diamond, CD). De forma complementar, foi realizado tratamento térmico a 170 °C por 10 minutos para melhor compreensão do comportamento desses materiais quanto ao potencial de conversão e à indução de tensões na interface carga/matriz. A avaliação do GC (n=3) foi realizada através de espectroscopia FTIR, a leitura da dureza Knoop foi realizada nas superfícies do topo e da base (n=3), e os ensaios de RF de três pontos (n=10) e KIC (n=10) em máquina de ensaios universais. Os resultados obtidos foram submetidos à analise de variância (complementados pelo teste de Tukey) ou teste Kruskal-Wallis, com nível de significância de 5%. A análise do GC (%) revelou diferença entre os materiais testados, sendo que todas as resinas bulk fill apresentaram valores maiores que a resina convencional: SF (75,7) > VBF (66,7) = EXP (66,4) = SDR (62,8), sendo esta também semelhante a FU (60,0); FU, TECBF (56,6), FBFF (56,6) e CD (54,5) apresentaram conversão semelhante. Os valores de KHN variaram de acordo com o material e com a superfície: apenas SF apresentou KHN semelhante (na superfície do topo) a CD, entretanto não foi possível realizar a leitura da superfície da base deste último material; SF, TECBF e FBFF apresentaram valores de KHN diferentes nas superfícies topo e base; EXP, FU, SDR e VBF mantiveram os valores de dureza do topo semelhantes à superfície da base. Para a RF (MPa), os resultados variaram de acordo com o material: EXP (122,54) = SF (101,09) = CD (99,15), sendo estes dois últimos semelhantes a FU (83,86) e TECBF (82,71), os quais não diferiram da resina SDR (65,18); esta última também mostrou comportamento semelhante a FBFF (60,85) e VBF (59,90). Quanto ao KIC (MPa.mm0,5), EXP (3,35) apresentou o maior valor, semelhante a SF (2,42), que por sua vez também foi igual ao compósito convencional CD (2,01); CD apresentou KIC semelhante a SDR (1,74); SDR = VBF (1,59) = TECBF (1,57); TECBF, FU (1,54) e FBFF (1,37) apresentaram valores semelhantes. Na dependência do material, o tratamento térmico aumentou os valores dos parâmetros estudados, apontando limitações da reação de polimerização dos compósitos estudados. Com base nos resultados obtidos, podese concluir que: resinas bulk fill apresentam elevado GC, superior à resina convencional estudada; a nova classe de materiais restauradores é capaz de polimerizar em profundidade e alguns materiais apresentam KHN semelhantes no topo e na base de espécimes de 4 mm de profundidade; RF e KIC variaram de acordo com o material, e o compósito EXP apresentou os maiores valores para ambos os testes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neste trabalho foi estudada a influência da adição de quitosana e sílica a monômeros dimetacrílicos, BisEMA e TEGDMA, por meio das técnicas de fotocalorimetria, termogravimetria e análise dinâmico mecânica. Os resultados dos experimentos de fotocalorimetria demonstraram que a quitosana pode aumentar a velocidade de polimerização e o máximo de conversão para alguns sistemas em determinadas concentrações da mesma, já a sílica tem pouco efeito nas reações de fotopolimerização das amostras. Para os experimentos de termogravimetria, a quitosana tem pouca influência na degradação das amostras não alterando significativamente as curvas TGA/DTG, por outro lado a sílica acelerou a degradação térmica das amostras. A avaliação das propriedades mecânicas demonstrou que a quitosana diminui a temperatura de transição vítrea e a resposta elástica dos sistemas não afetando os valores dos módulos de armazenamento e módulos de perda. A sílica apresentou a tendência de aumento de temperatura de transição vítrea e não alteração da resposta elástica das amostras.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do grau de Mestre no Instituto Superior de Ciências da Saúde Egas Moniz