963 resultados para Reliability level
Resumo:
Objectives: The study was designed to show the validity and reliability of scoring the Physical Mobility Scale (PMS). PMS was developed by physiotherapists working in residential aged care to specifically show resident functional mobility and to provide information regarding each resident's need for supervision or assistance from one or two staff members and equipment during position changes, transfers, mobilising and personal care. Methods: Nineteen physiotherapists of varying backgrounds and experience scored the performances of nine residents of care facilities from video recordings. The performances were compared to scores on two 'gold standard' assessment tools. Four of the physiotherapists repeated the evaluations. Results: The PAIS showed excellent content validity and reliability. Conclusions: The PAIS provides graded performance of physical mobility, including level of dependency on staff and equipment. This is a major advantage over existing functional assessment tools. There is no need for specific training for physiotherapists to use the tool.
Resumo:
Purpose: This study was conducted to examine the test-retest reliability of a measure of prediagnosis physical activity participation administered to colorecial cancer survivors recruited from a population-based state cancer registry. Methods: A total of 112 participants completed two telephone interviews. I month apart, reporting usual weekly physical activity in the year before their cancer diagnosis. Intraclass correlation coefficients (ICC) and standard en-or of measurement (SEM) were used to describe the test-retest reliability of the measure across the sample: the Bland-Altman approach was used to describe reliability at the individual level. The test-retest reliability for categorized total physical activity (active, insufficiently active, sedentary) was assessed using the kappa statistic. Results: When the complete sample was considered, the ICC ranged from 0.40 (95% Cl: 0.24, 0.55) for vigorous gardening to 0.77 (95% Cl: 0.68, 0.84) for moderate physical activity. The SEM, however, were large. indicating high measurement error. The Bland-Altman plots indicated that the reproducibility of data decreases as the aniount of physical activity reported each week increases The kappa coefficient for the categorized data was 0.62 (95% Cl: 0.48, 0.76). Conclusion: Overall. the results indicated low levels of repeatability for this measure of historical physical activity. Categorizing participants as active, insufficiently active, or sedentary provides a higher level of test-retest reliability.
Resumo:
Statistical physics is employed to evaluate the performance of error-correcting codes in the case of finite message length for an ensemble of Gallager's error correcting codes. We follow Gallager's approach of upper-bounding the average decoding error rate, but invoke the replica method to reproduce the tightest general bound to date, and to improve on the most accurate zero-error noise level threshold reported in the literature. The relation between the methods used and those presented in the information theory literature are explored.
Resumo:
A highly sensitive liquid-level sensor based on dual-wavelength single-longitudinal-mode fiber laser is proposed and demonstrated. The laser is formed by exploiting two parallel arranged phase-shift fiber Bragg gratings (ps-FBGs), acting as ultra-narrow bandwidth filters, into a doublering resonators. By beating the dual-wavelength lasing output, a stable microwave signal with frequency stability better than 5 MHz is obtained. The generated beat frequency varies with the change of dual-wavelength spacing. Based on this characteristic, with one ps-FBG serving as the sensing element and the other one acting as the reference element, a highly sensitive liquid level sensor is realized by monitoring the beat frequency shift of the laser. The sensor head is directly bonded to a float which can transfer buoyancy into axial strain on the fiber without introducing other elastic elements. The experimental results show that an ultra-high liquidlevel sensitivity of 2.12 × 107 MHz/m within the measurement range of 1.5 mm is achieved. The sensor presents multiple merits including ultra-high sensitivity, thermal insensitive, good reliability and stability. © 2012 Optical Society of America.
Resumo:
This dissertation describes the findings and implications of a correlational analysis. Scores earned on the Computerized Placement Test (CPT), sentence skills, were compared to essay scores of advanced English as a Second Language (ESL) students. As the CPT is designed for native speakers of English, it was hypothesized that it could be an invalid or unreliable instrument for non-native speakers. Florida community college students are mandated to take the CPT to determine preparedness, as are students at many other U.S. and Canadian colleges. If incoming students score low on the CPT, they may be required to take up to three semesters of remedial coursework. It is essential that scores earned by non-native speakers of English accurately reflect their ability level. They constitute a large and growing body of non-traditional students enrolled at community colleges.^ The study was conducted at Miami-Dade Community College, Wolfson Campus, fall 1997. Participants included 106 advanced ESL students who took both the CPT sentence skills test and wrote final essay exams. The essay exams were holistically scored by trained readers. Also, the participants took the Placement Articulation Software Service (PASS) exam, an alternative form of the CPT. Scores on the CPT and essays were compared by means of a Pearson product-moment correlation to validate the CPT. Scores on the CPT and the PASS exam were compared in the same manner to verify reliability. A percentage of appropriate placements was determined by comparing essay scores to CPT cutoff score ranges. Finally, the instruments were evaluated by means of independent-samples t-tests for performance differences between gender, age, and first language groups.^ The results indicate that the CPT sentence skills test is a valid and reliable placement instrument for advanced- level ESL students who intend to pursue community college degrees. The correlations demonstrated a substantial relationship between CPT and essay scores and a marked relationship between CPT and PASS scores. Appropriate placements were made in 86% of the cases. Furthermore, the CPT was found to discriminate equally among the gender, age, and first language groups included in this study. ^
Resumo:
Road pricing has emerged as an effective means of managing road traffic demand while simultaneously raising additional revenues to transportation agencies. Research on the factors that govern travel decisions has shown that user preferences may be a function of the demographic characteristics of the individuals and the perceived trip attributes. However, it is not clear what are the actual trip attributes considered in the travel decision- making process, how these attributes are perceived by travelers, and how the set of trip attributes change as a function of the time of the day or from day to day. In this study, operational Intelligent Transportation Systems (ITS) archives are mined and the aggregated preferences for a priced system are extracted at a fine time aggregation level for an extended number of days. The resulting information is related to corresponding time-varying trip attributes such as travel time, travel time reliability, charged toll, and other parameters. The time-varying user preferences and trip attributes are linked together by means of a binary choice model (Logit) with a linear utility function on trip attributes. The trip attributes weights in the utility function are then dynamically estimated for each time of day by means of an adaptive, limited-memory discrete Kalman filter (ALMF). The relationship between traveler choices and travel time is assessed using different rules to capture the logic that best represents the traveler perception and the effect of the real-time information on the observed preferences. The impact of travel time reliability on traveler choices is investigated considering its multiple definitions. It can be concluded based on the results that using the ALMF algorithm allows a robust estimation of time-varying weights in the utility function at fine time aggregation levels. The high correlations among the trip attributes severely constrain the simultaneous estimation of their weights in the utility function. Despite the data limitations, it is found that, the ALMF algorithm can provide stable estimates of the choice parameters for some periods of the day. Finally, it is found that the daily variation of the user sensitivities for different periods of the day resembles a well-defined normal distribution.
Resumo:
Technological developments in biomedical microsystems are opening up new opportunities to improve healthcare procedures. Swallowable diagnostic sensing capsules are an example of these. In none of the diagnostic sensing capsules, is the sensor’s first level packaging achieved via Flip Chip Over Hole (FCOH) method using Anisotropic Conductive Adhesive (ACA). In a capsule application with direct access sensor (DAS), ACA not only provides the electrical interconnection but simultaneously seals the interconnect area and the underlying electronics. The development showed that the ACA FCOH was a viable option for the DAS interconnection. Adequate adhesive formed a strong joint that withstood a shear stress of 120N/mm2 and a compressive stress of 6N required to secure the final sensor assembly in place before encapsulation. Electrical characterization of the ACA joint in a fluid environment showed that the ACA was saturated with moisture and that the ions in the solution actively contributed to the leakage current, characterized by the varying rate of change of conductance. Long term hygrothermal aging of the ACA joint showed that a thermal strain of 0.004 and a hygroscopic strain of 0.0052 were present and resulted in a fatigue like process. In-vitro tests showed that high temperature and acidity had a deleterious effect of the ACA and its joint. It also showed that the ACA contact joints positioned at around or over 1mm would survive the gastrointestinal (GI) fluids and would be able to provide a reliable contact during the entire 72hr of the GI transit time. A final capsule demonstrator was achieved by successfully integrating the DAS, the battery and the final foldable circuitry into a glycerine capsule. Final capsule soak tests suggested that the silicone encapsulated system could survive the 72hr gut transition.
Resumo:
BACKGROUND: The recently developed Context Assessment for Community Health (COACH) tool aims to measure aspects of the local healthcare context perceived to influence knowledge translation in low- and middle-income countries. The tool measures eight dimensions (organizational resources, community engagement, monitoring services for action, sources of knowledge, commitment to work, work culture, leadership, and informal payment) through 49 items. OBJECTIVE: The study aimed to explore the understanding and stability of the COACH tool among health providers in Vietnam. DESIGNS: To investigate the response process, think-aloud interviews were undertaken with five community health workers, six nurses and midwives, and five physicians. Identified problems were classified according to Conrad and Blair's taxonomy and grouped according to an estimation of the magnitude of the problem's effect on the response data. Further, the stability of the tool was examined using a test-retest survey among 77 respondents. The reliability was analyzed for items (intraclass correlation coefficient (ICC) and percent agreement) and dimensions (ICC and Bland-Altman plots). RESULTS: In general, the think-aloud interviews revealed that the COACH tool was perceived as clear, well organized, and easy to answer. Most items were understood as intended. However, seven prominent problems in the items were identified and the content of three dimensions was perceived to be of a sensitive nature. In the test-retest survey, two-thirds of the items and seven of eight dimensions were found to have an ICC agreement ranging from moderate to substantial (0.5-0.7), demonstrating that the instrument has an acceptable level of stability. CONCLUSIONS: This study provides evidence that the Vietnamese translation of the COACH tool is generally perceived to be clear and easy to understand and has acceptable stability. There is, however, a need to rephrase and add generic examples to clarify some items and to further review items with low ICC.
Resumo:
Buses are considered a slow, low comfort and low reliability transport system, thus its negative and por image. In the framework of the 3iBS project (2012), several examples of innovative and/or effective solutions regarding the Level of Service (LoS) were analysed aiming to provide operators, practitioners and policy makers with a set of Good Practice Guidelines to strengthen the competitiveness of the bus in the urban environment. The identification of the key indicators regarding vehicles, infrastructure and operation was possible through the analysis of a set of case studies -among which Barcelona (Spain), Cagliari (Italy), London (United Kingdom), Paris and Nantes (France). A cross comparison between the case studies was carried out for contrasting the level of achievement of the different criteria considered. The information provided on Regulatory, Financial and Technical issues allows the identification of a number of specific factors influencing the implementation of a high quality transport scheme, and set the basis for the elaboration of a set of Guidelines for the implementation of an intelligent, innovative and integrated bus system, including the main barriers to be tackled.
Resumo:
There is an increasing concern to reduce the cost and overheads during the development of reliable systems. Selective protection of most critical parts of the systems represents a viable solution to obtain a high level of reliability at a fraction of the cost. In particular to design a selective fault mitigation strategy for processor-based systems, it is mandatory to identify and prioritize the most vulnerable registers in the register file as best candidates to be protected (hardened). This paper presents an application-based metric to estimate the criticality of each register from the microprocessor register file in microprocessor-based systems. The proposed metric relies on the combination of three different criteria based on common features of executed applications. The applicability and accuracy of our proposal have been evaluated in a set of applications running in different microprocessors. Results show a significant improvement in accuracy compared to previous approaches and regardless of the underlying architecture.
Resumo:
The purpose of this study was to examine the reliability and validity of the School Anxiety Inventory (SAI) using a sample of 646 Slovenian adolescents (48% boys), ranging in age from 12 to 19 years. Single confirmatory factor analyses replicated the correlated four-factor structure of scores on the SAI for anxiety-provoking school situations (Anxiety about School Failure and Punishment, Anxiety about Aggression, Anxiety about Social Evaluation, and Anxiety about Academic Evaluation), and the three-factor structure of the anxiety response systems (Physiological Anxiety, Cognitive Anxiety, and Behavioral Anxiety). Equality of factor structures was compared using multigroup confirmatory factor analyses. Measurement invariance for the four- and three-factor models was obtained across gender and school-level samples. The scores of the instrument showed high internal reliability and adequate test–retest reliability. The concurrent validity of the SAI scores was also examined through its relationship with the Social Anxiety Scale for Adolescents (SASA) scores and the Questionnaire about Interpersonal Difficulties for Adolescents (QIDA) scores. Correlations of the SAI scores with scores on the SASA and the QIDA were of low to moderate effect sizes.
Resumo:
Access to improved potable water sources is recognized as one of the key factors in improving health and alleviating global poverty. In recently years, substantial investments have been made internationally in potable water infrastructure projects, allowing 2.3 billion people to gain access to potable water from 1990-2012. One such project was planned and installed in Solla, Togo, a rural village in the northern part of the country, from 2010-2012. Ethnographic studies revealed that, while the community has access to potable water, an estimated 45% of the village’s 1500 residents still rely on unprotected sources for drinking and cooking. Additionally, inequality in system use based on income level was revealed, with the higher income groups accessing the system more regularly than lower income groups. Cost, as well as the availability of cheaper sources, was identified as the main deterrent from using the new water distribution system. A new water-pricing scheme is investigated here with the intention of making the system accessible to a greater percentage of the population. Since 2012, a village-level water committee has been responsible for operations and maintenance (O&M), fulfilling the community management model that is recommended by many development theorists in order to create sustainable projects. The water committee received post-construction support, mostly in the form of technical support during system breakdowns, from the Togolese Ministry of Water and Sanitation (MWSVH). While this support has been valuable in maintaining a functional water supply system in Solla, the water committee still has managerial challenges, particularly with billing and fee collection. As a result, the water committee has only received 2% - 25% of the fees owed at each private connection and public tap stand, making their finances vulnerable when future repairs and capital replacements are necessary. A new management structure is proposed by the MWSVH that will pay utilities workers a wage and will hire an accountant in order to improve the local management and increase revenue. This proposal is analyzed under the new water pricing schemes that are presented. Initially, the rural water supply system was powered by a diesel-generator, but in 2013, a solar photo-voltaic power supply was installed. The new system proved a fiscal improvement for the village water committee, since it drastically reduced their annual O&M costs. However, the new system pumps a smaller volume of water on a daily basis and did not meet the community’s water needs during the dry season of 2014. A hydraulic network model was developed to investigate the system’s reliability under diesel-generator (DGPS) and solar photovoltaic (PVPS) power supplies. Additionally, a new system layout is proposed for the PVPS that allows pumping directly into the distribution line, circumventing the high head associated with pumping solely to the storage tank. It was determined that this new layout would allow for a greater volume of water to be provided to the demand points over the course of a day, meeting a greater fraction of the demand than with the current layout.
Resumo:
Safety in civil aviation is increasingly important due to the increase in flight routes and their more challenging nature. Like other important systems in aircraft, fuel level monitoring is always a technical challenge. The most frequently used level sensors in aircraft fuel systems are based on capacitive, ultrasonic and electric techniques, however they suffer from intrinsic safety concerns in explosive environments combined with issues relating to reliability and maintainability. In the last few years, optical fiber liquid level sensors (OFLLSs) have been reported to be safe and reliable and present many advantages for aircraft fuel measurement. Different OFLLSs have been developed, such as the pressure type, float type, optical radar type, TIR type and side-leaking type. Amongst these, many types of OFLLSs based on fiber gratings have been demonstrated. However, these sensors have not been commercialized because they exhibit some drawbacks: low sensitivity, limited range, long-term instability, or limited resolution. In addition, any sensors that involve direct interaction of the optical field with the fuel (either by launching light into the fuel tank or via the evanescent field of a fiber-guided mode) must be able to cope with the potential build up of contamination-often bacterial-on the optical surface. In this paper, a fuel level sensor based on microstructured polymer optical fiber Bragg gratings (mPOFBGs), including poly (methyl methacrylate) (PMMA) and TOPAS fibers, embedded in diaphragms is investigated in detail. The mPOFBGs are embedded in two different types of diaphragms and their performance is investigated with aviation fuel for the first time, in contrast to our previous works, where water was used. Our new system exhibits a high performance when compared with other previously published in the literature, making it a potentially useful tool for aircraft fuel monitoring.
Resumo:
The International FItness Scale (IFIS) is a self-reported measure of physical fitness that could easily. This scale has been validated in children, adolescents, and young adults; however, it is unknown whether the IFIS represents a valid and reliable estimate of physical fitness in Latino-American youth population. In the present study we aimed to examine the validity and reliability of the IFIS on a population-based sample of schoolchildren in Bogota, Colombia. Participants were 1,875 Colombian youth (56.2% girls) aged 9 to 17.9 years old. We measured adiposity markers (body fat, waist-to-height ratio, skinfold thicknesses and BMI), blood pressure, lipids profile, fasting glucose, and physical fitness level (self reported and measured). Also, a validated cardiometabolic risk index was used. An age- and sex-matched sample of 229 Schoolchildren originally not included in the study sample fulfilled IFIS twice for reliability purposes. Our data suggest that both measured and self-reported overall fitness were associated inversely with adiposity indicators and a cardiometabolic risk score. Overall, schoolchildren who self-reported “good” and “very good” fitness had better measured fitness than those who reported “very poor” and “poor” fitness (all p<0.001). Test–retest reliability of IFIS items was also good, with an average weighted Kappa of 0.811. Therefore, our findings suggest that self-reported fitness, as assessed by IFIS, is a valid, reliable, and health-related measure, and it can be a good alternative for future use in large studies with Latin-schoolchildren from Colombia.
Resumo:
The aim of the present study was to examine the reliability of tethered swimming in the evaluation of age group swimmers. The sample was composed of 8 male national level swimmers with at least 4 years of experience in competitive swimming. Each swimmer performed two 30 second maximal intensity tethered swimming tests, on separate days. Individual force-time curves were registered to assess maximum force, mean force and the mean impulse of force. Both consistency and reliability were very strong, with Cronbach’s Alpha values ranging from 0.970 to 0.995. All the applied metrics presented a very high agreement between tests, with the mean impulse of force presenting the highest. These results indicate that tethered swimming can be used to evaluate age group swimmers. Furthermore, better comprehension of the swimmers ability to effectively exert force in the water can be obtained using the impulse of force. Key words: swimming, training and testing, propulsive force, front crawl.