986 resultados para RIII-reflex
Resumo:
We have previously observed a change in the magnitude of the soleus (SOL) and medial gastrocnemius (MG) H-reflexes during different sway positions of quiet standing. The purpose of the present study was to extend the earlier finding by examining whether the SOL and MG H-reflexes are additionally influenced by the velocity of sway, i.e., whether the body is swaying in either the forward or backward direction. Five healthy subjects participated in the study. The mean position of the centre of pressure (COP) in the antero-posterior direction was determined while the subject stood quietly on a force plate for 60 s. In contrast to the earlier study, where the H-reflex was tested at the outermost positions of sway (±6 mm from the baseline mean), the current study elicited a SOL and MG H-reflex as the COP passed through the mean position of sway. This resulted in two sway conditions, where the position of the COP was the same but the sway velocity was different (10 mm s-1 forward and 10 mm s-1 backward). During the forward as compared to the backward velocity condition, there was a 20% and 25% increase in the amplitude of the H-reflex for the SOL and MG muscles, respectively, while the size of their respective background activities were the same. SOL and MG M-waves, as well as the level of background activity from the antagonist (tibialis anterior), were not different between the two sway conditions and thus cannot account for the observed changes to the amplitude of the H-reflexes. It can be concluded from these results that the direction (velocity) of sway has the ability to influence the size of the SOL and MG H-reflexes. The facilitation of the SOL and MG H-reflexes observed while swaying forward may be due to a reduction in presynaptic inhibition or an improvement in Ia synaptic efficacy brought about by changes in muscle length.
Resumo:
The literature suggests that there may be pupil size and response abnormalities in migraine headache sufferers. We used an infra-red pupillometer to measure dynamic pupil responses to light in 20 migraine sufferers (during non-headache periods) and 16 non-migraine age and gender matched controls. There was a significant increase in the absolute inter-ocular difference of the latency of the pupil light response in the migraine group compared with the controls (0.062 s vs 0.025 s, p = 0.014). There was also a significant correlation between anisocoria and lateralisation of headache such that migraine sufferers with a habitual head pain side have more anisocoria (r= 0.59, p < 0.01), but this was not related to headache laterally. The pupil changes were not correlated with the interval since the last migraine headache, the severity of migraine headache or the number of migraine headaches per annum. We conclude that subtle sympathetic and parasympathetic pupil abnormalities persist in the inter-ictal phase of migraine. © 2005 The College of Optometrists.
Resumo:
OBJECTIVES: In natural hearing, cochlear mechanical compression is dynamically adjusted via the efferent medial olivocochlear reflex (MOCR). These adjustments probably help understanding speech in noisy environments and are not available to the users of current cochlear implants (CIs). The aims of the present study are to: (1) present a binaural CI sound processing strategy inspired by the control of cochlear compression provided by the contralateral MOCR in natural hearing; and (2) assess the benefits of the new strategy for understanding speech presented in competition with steady noise with a speech-like spectrum in various spatial configurations of the speech and noise sources. DESIGN: Pairs of CI sound processors (one per ear) were constructed to mimic or not mimic the effects of the contralateral MOCR on compression. For the nonmimicking condition (standard strategy or STD), the two processors in a pair functioned similarly to standard clinical processors (i.e., with fixed back-end compression and independently of each other). When configured to mimic the effects of the MOCR (MOC strategy), the two processors communicated with each other and the amount of back-end compression in a given frequency channel of each processor in the pair decreased/increased dynamically (so that output levels dropped/increased) with increases/decreases in the output energy from the corresponding frequency channel in the contralateral processor. Speech reception thresholds in speech-shaped noise were measured for 3 bilateral CI users and 2 single-sided deaf unilateral CI users. Thresholds were compared for the STD and MOC strategies in unilateral and bilateral listening conditions and for three spatial configurations of the speech and noise sources in simulated free-field conditions: speech and noise sources colocated in front of the listener, speech on the left ear with noise in front of the listener, and speech on the left ear with noise on the right ear. In both bilateral and unilateral listening, the electrical stimulus delivered to the test ear(s) was always calculated as if the listeners were wearing bilateral processors. RESULTS: In both unilateral and bilateral listening conditions, mean speech reception thresholds were comparable with the two strategies for colocated speech and noise sources, but were at least 2 dB lower (better) with the MOC than with the STD strategy for spatially separated speech and noise sources. In unilateral listening conditions, mean thresholds improved with increasing the spatial separation between the speech and noise sources regardless of the strategy but the improvement was significantly greater with the MOC strategy. In bilateral listening conditions, thresholds improved significantly with increasing the speech-noise spatial separation only with the MOC strategy. CONCLUSIONS: The MOC strategy (1) significantly improved the intelligibility of speech presented in competition with a spatially separated noise source, both in unilateral and bilateral listening conditions; (2) produced significant spatial release from masking in bilateral listening conditions, something that did not occur with fixed compression; and (3) enhanced spatial release from masking in unilateral listening conditions. The MOC strategy as implemented here, or a modified version of it, may be usefully applied in CIs and in hearing aids.
Resumo:
To evaluate the possible blink reflex responses in facial muscles reinnervated by the accessory nerve. Method: Eleven patients with a complete facial palsy were submitted to a surgical repair by an accessory facial nerve anastomosis (AFA). In this pathological group, blink reflex was studied by means of percutaneous electrical stimulation of the supraorbital nerve and recording from the orbicularis oculi muscle. A control group comprised seven normal people and seven patients with a complete Bell's facial palsy; in this group, responses on the sternocleidomastoideus (SCM) muscles were studied after supraorbital nerve stimulation. Results: All the patients with AFA showed a consistent degree of facial reinnervation. Ten out of the 11 patients with AFA showed reflex responses; in six, responses were configured by a double component pattern, resembling the R1 and R2 components of the blink reflex; three patients had an R1-like response and one patient showed a unique R2 component. Mean values of latencies were 15.2 (SD 4.6) ms for the R1 and 85.3 (SD 9.6) ms for the R2. In the control group, eight out of 14 people had evidence of reflex responses in the SCM muscles; these were almost exclusively configured by a bilateral late component (mean latency 63.5 (SD 15.9) ms) and only one of the subjects showed an early response at 11 ms. Conclusion: The trigemino-accessory reflex response in the pathological group was more complex and of a significantly higher incidence than in the control group. These differences could be tentatively explained by a mechanism of synaptic plasticity induced by the impairment of the efferent portion of the reflex. This could unmask the central linking between the trigeminal and the accessory limbs of the reflex. The findings described could be a demonstration of neurobionomic function in the repairing process of the nervous system.
Resumo:
Agonists such as icilin and menthol can activate the cool temperature-sensitive ion channel TRPM8. However, biological responses to menthol may occur independently of TRPM8 activation. In the rodent urinary bladder, menthol facilitates the micturition reflex but inhibits muscarinic contractions of the detrusor smooth muscle. The site(s) of TRPM8 expression in the bladder are controversial. In this study we investigated the regulation of bladder contractility in vitro by menthol. Bladder strips from wild type and TRPM8 knockout male mice (25-30 g) were dissected free and mounted in organ baths. Isometric contractions to carbachol (1 nM-30 µM), CaCl2 (1 µM to 100 mM) and electrical field stimulation (EFS; 8, 16, 32 Hz) were measured. Strips from both groups contracted similarly in response to both carbachol and EFS. Menthol (300 µM) or nifedipine (1 µM) inhibited carbachol and EFS-induced contractions in both wild type and TRPM8 knockout bladder strips. Incubation with the sodium channel blocker tetrodotoxin (1 µM), replacement of extracellular sodium with the impermeant cation N-Methyl-D-Glucamine, incubation with a cocktail of potassium channel inhibitors (100 nM charybdotoxin, 1 µM apamin, 10 µM glibenclamide and 1 µM tetraethylammonium) or removal of the urothelium did not affect the inhibitory actions of menthol. Contraction to CaCl2 was markedly inhibited by either menthol or nifedipine. In cultured bladder smooth muscle cells, menthol or nifedipine abrogated the carbachol or KCl-induced increases in [Ca2+]i. Intravesical administration of menthol increased voiding frequency while decreasing peak voiding pressure. We conclude that menthol inhibits muscarinic bladder contractions through blockade of L-type calcium channels, independently of TRPM8 activation.
Resumo:
To assess binocular detection grating acuity using the LEA GRATINGS test to establish age-related norms in healthy infants during their first 3 months of life. In this prospective, longitudinal study of healthy infants with clear red reflex at birth, responses to gratings were measured at 1, 2, and 3 months of age using LEA gratings at a distance of 28 cm. The results were recorded as detection grating acuity values, which were arranged in frequency tables and converted to a one-octave scale for statistical analysis. For the repeated measurements, analysis of variance (ANOVA) was used to compare the detection grating acuity results between ages. A total of 133 infants were included. The binocular responses to gratings showed development toward higher mean values and spatial frequencies, ranging from 0.55 ± 0.70 cycles per degree (cpd), or 1.74 ± 0.21 logMAR, in month 1 to 3.11 ± 0.54 cpd, or 0.98 ± 0.16 logMAR, in month 3. Repeated ANOVA indicated differences among grating acuity values in the three age groups. The LEA GRATINGS test allowed assessment of detection grating acuity and its development in a cohort of healthy infants during their first 3 months of life.
Resumo:
Mechanically evoked reflexes have been postulated to be less sensitive to presynaptic inhibition (PSI) than the H-reflex. This has implications on investigations of spinal cord neurophysiology that are based on the T-reflex. Preceding studies have shown an enhanced effect of PSI on the H-reflex when a train of ~10 conditioning stimuli at 1 Hz was applied to the nerve of the antagonist muscle. The main questions to be addressed in the present study are if indeed T-reflexes are less sensitive to PSI and whether (and to what extent and by what possible mechanisms) the effect of low frequency conditioning, found previously for the H-reflex, can be reproduced on T-reflexes from the soleus muscle. We explored two different conditioning-to-test (C-T) intervals: 15 and 100 ms (corresponding to D1 and D2 inhibitions, respectively). Test stimuli consisted of either electrical pulses applied to the posterior tibial nerve to elicit H-reflexes or mechanical percussion to the Achilles tendon to elicit T-reflexes. The 1 Hz train of conditioning electrical stimuli delivered to the common peroneal nerve induced a stronger effect of PSI as compared to a single conditioning pulse, for both reflexes (T and H), regardless of C-T-intervals. Moreover, the conditioning train of pulses (with respect to a single conditioning pulse) was proportionally more effective for T-reflexes as compared to H-reflexes (irrespective of the C-T interval), which might be associated with the differential contingent of Ia afferents activated by mechanical and electrical test stimuli. A conceivable explanation for the enhanced PSI effect in response to a train of stimuli is the occurrence of homosynaptic depression at synapses on inhibitory interneurons interposed within the PSI pathway. The present results add to the discussion of the sensitivity of the stretch reflex pathway to PSI and its functional role.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física