878 resultados para RFID sensors
Resumo:
The paper analyses and compares infrasonic and seismic data from snow avalanches monitored at the Vallée de la Sionne test site in Switzerland from 2009 to 2010. Using a combination of seismic and infrasound sensors, it is possible not only to detect a snow avalanche but also to distinguish between the different flow regimes and to analyse duration, average speed (for sections of the avalanche path) and avalanche size. Different sensitiveness of the seismic and infrasound sensors to the avalanche regimes is shown. Furthermore, the high amplitudes observed in the infrasound signal for one avalanche were modelled assuming that the suspension layer of the avalanche acts as a moving turbulent sound source. Our results show reproducibility for similar avalanches on the same avalanche path.
Resumo:
In order to distinguish dysfunctional gait; clinicians require a measure of reference gait parameters for each population. This study provided normative values for widely used parameters in more than 1400 able-bodied adults over the age of 65. We also measured the foot clearance parameters (i.e., height of the foot above ground during swing phase) that are crucial to understand the complex relationship between gait and falls as well as obstacle negotiation strategies. We used a shoe-worn inertial sensor on each foot and previously validated algorithms to extract the gait parameters during 20 m walking trials in a corridor at a self-selected pace. We investigated the difference of the gait parameters between male and female participants by considering the effect of age and height factors. Besides; we examined the inter-relation of the clearance parameters with the gait speed. The sample size and breadth of gait parameters provided in this study offer a unique reference resource for the researchers.
Resumo:
Introduction. Quantification of daily upper-limb activity is a key determinant in evaluation of shoulder surgery. For a number of shoulder diseases, problem in performing daily activities have been expressed in terms of upper-limb usage and non-usage. Many instruments measure upper-limb movement but do not focus on the differentiations between the use of left or right shoulder. Several methods have been used to measure it using only accelerometers, pressure sensors or video-based analysis. However, there is no standard or widely used objective measure for upper-limb movement. We report here on an objective method to measure the movement of upper-limb and we examined the use of 3D accelerometers and 3D gyroscopes for that purpose. Methods. We studied 8 subjects with unilateral pathological shoulder (8 rotator cuff disease: 53 years old ± 8) and compared them to 18 control subjects (10 right handed, 8 left handed: 32 years old ± 8, younger than the patient group to be almost sure they don_t have any unrecognized shoulder pathology). The Simple Shoulder Test (SST) and Disabilities of the Arm and Shoulder Score (DASH) questionnaires were completed by each subject. Two modules with 3 miniature capacitive gyroscopes and 3 miniature accelerometers were fixed by a patch on the dorsal side of the distal humerus, and one module with 3 gyroscopes and 3 accelerometers were fixed on the thorax. The subject wore the system during one day (8 hours), at home or wherever he/she went. We used a technique based on the 3D acceleration and the 3D angular velocities from the modules attached on the humerus. Results. As expected, we observed that for the stand and sit postures the right side is more used than the left side for a healthy right-handed person(idem on the left side for a healthy left-handed person). Subjects used their dominant upper-limb 18% more than the non-dominant upper-limb. The measurements on patients in daily life have shown that the patient has used more his non affected and non dominant side during daily activity if the dominant side = affected shoulder. If the dominant side affected shoulder, the difference can be showed only during walking period. Discussion-Conclusion. The technique developed and used allowed the quantification of the difference between dominant and non dominant side, affected and unaffected upper-limb activity. These results were encouraging for future evaluation of patients with shoulder injuries, before and after surgery. The feasibility and patient acceptability of the method using body fixed sensors for ambulatory evaluation of upper limbs kinematics was shown.
Resumo:
L'objectiu d'aquest projecte és desenvolupar una eina de gestió d'horaris, creació d'un lector sense fil amb la tecnologia NFC i realitzar-ho tot amb el pressupost més baix possible.
Resumo:
RFID on 2000-luvulla yleisesti saatavilla tullut tekniikka erilaisten kohteiden tunnistamiseen. RFID-tekniikassa tunnistamiseen käytetään pienikokoisia tunnisteita, joiden tietosisältö pystytään lukemaan langattomasti ilman näköyhteyttä tarkoitukseen soveltuvalla lukulaitteella. Tunnisteet ovat halpoja ja yksinkertaisia. Yleensä ne eivät sisällä omaa virtalähdettä, vaan ne toimivat ainoastaan lukulaitteen luoman kentän voimalla. Tässä työssä tutkitaan RFID-tekniikan soveltuvuutta betonista valmistettujen rakennuselementtien tunnistamiseen. Ympäristön vaikutukset tekniikan käyttöön tutkitaan ja selvitetään, mitkä ovat parhaat toimintatavat elementtien tunnistamiseen nämä vaikutukset huomioon ottaen. Työssä esitellään ensin RFID-tekniikan toimintaperiaatteet sekä tunnisteiden ja lukulaitteiden rakenne. Tunnisteiden jaottelu erilaisten ominasisuuksien perusteella käydään läpi ja sovellusalan kannalta tärkeimmät standardit esitellään. Käytännön osuudessa esitellään RFID-tekniikan soveltamista betonista valmistettujen rakennuselementtien tunnistamiseen. Työssä esitellään saavutetut mittaustulokset sekä betonielementtien tunnistamiseen ja tietojen hallintaan toteutetun järjestelmän rakenne.
Resumo:
The widespread misuse of drugs has increased the number of multiresistant bacteria, and this means that tools that can rapidly detect and characterize bacterial response to antibiotics are much needed in the management of infections. Various techniques, such as the resazurin-reduction assays, the mycobacterial growth indicator tube or polymerase chain reaction-based methods, have been used to investigate bacterial metabolism and its response to drugs. However, many are relatively expensive or unable to distinguish between living and dead bacteria. Here we show that the fluctuations of highly sensitive atomic force microscope cantilevers can be used to detect low concentrations of bacteria, characterize their metabolism and quantitatively screen (within minutes) their response to antibiotics. We applied this methodology to Escherichia coli and Staphylococcus aureus, showing that live bacteria produced larger cantilever fluctuations than bacteria exposed to antibiotics. Our preliminary experiments suggest that the fluctuation is associated with bacterial metabolism.
Resumo:
In the drilling processes and especially deep-hole drilling process, the monitoring system and having control on mechanical parameters (e.g. Force, Torque,Vibration and Acoustic emission) are essential. The main focus of this thesis work is to study the characteristics of deep-hole drilling process, and optimize the monitoring system for controlling the process. The vibration is considered as a major defect area of the deep-hole drilling process which often leads to breakage of the drill, therefore by vibration analysis and optimizing the workpiecefixture, this area is studied by finite element method and the suggestions are explained. By study on a present monitoring system, and searching on the new sensor products, the modifications and recommendations are suggested for optimize the present monitoring system for excellent performance in deep-hole drilling process research and measurements.
Resumo:
Aquest projecte inclou una aproximació als conceptes de RFID i targetes contactless centrant-se en l’ampliament usat MIFARE Classic chip. L’objectiu principal es mostrar el seu funcionament i les seves vulnerabilitats, així com alguns exemples pràctics fent una anàlisi de diferents serveis que les utilitzen.
Resumo:
Canopy characterization is a key factor to improve pesticide application methods in tree crops and vineyards. Development of quick, easy and efficient methods to determine the fundamental parameters used to characterize canopy structure is thus an important need. In this research the use of ultrasonic and LIDAR sensors have been compared with the traditional manual and destructive canopy measurement procedure. For both methods the values of key parameters such as crop height, crop width, crop volume or leaf area have been compared. Obtained results indicate that an ultrasonic sensor is an appropriate tool to determine the average canopy characteristics, while a LIDAR sensor provides more accuracy and detailed information about the canopy. Good correlations have been obtained between crop volume (CVU) values measured with ultrasonic sensors and leaf area index, LAI (R2 = 0.51). A good correlation has also been obtained between the canopy volume measured with ultrasonic and LIDAR sensors (R2 = 0.52). Laser measurements of crop height (CHL) allow one to accurately predict the canopy volume. The proposed new technologies seems very appropriate as complementary tools to improve the efficiency of pesticide applications, although further improvements are still needed.
Resumo:
ITENE és un institut tecnològic de recerca situat a Paterna (València). Té una plantapilot especialitzada en logística on les empreses que ho vulguin (mitjançant convenis,en règim de lloguer, etc.), poden utilitzar les instal•lacions (magatzem intel•ligent,aplicacions RFID, etc.), per provar els seus productes i simular processos de logística itraçabilitat.En aquesta planta s'ha detectat la necessitat de poder provar nous productes cometiquetes, detectors i processadors equipats amb tecnologia RFID (Identificació perRadiofreqüència). Aquesta tecnologia consisteix en passar informació que conté unaetiqueta “intel•ligent” cap a un terminal (PC) mitjançant uns detectors que, perproximitat, poden llegir la informació. Per exemple, quan un camió ple de mercaderiesprèviament etiquetades, passa per un pòrtic amb detectors RFID, es genera unainformació que passa directament a un terminal. Al moment es pot saber què porta elcamió, quantitat, color, mides, etc. Si això es combina amb un ERP, es pot descomptarde l'estoc en temps real. De fet s'utilitza per moltes aplicacions logística, control deprocessos de fabricació, traçabilitat de productes, etc.Per aquest motiu, ITENE, mitjançant el contacte de AIFOS SOLUTIONS S.L (empresaespecialitzada en RFID) ha encarregat un sistema de transportadors de banda per provarnoves solucions.L'objecte del present projecte consisteix en el disseny i automatització d'un sistema de 4cintes transportadores 2 elevadors per tal de fer un circuit tancat per moure caixes en un“bucle” de forma automàtica. L'objectiu és “llençar” caixes plenes de productes (etiquetats amb RFID) mitjançant untransportador equipat amb un pòrtic que té instal•lats diversos detectors de radiofreqüència,i poder-ne provar la correcta detecció a diferents velocitats. Un “buffer” s'encarrega desubministrar les caixes d'una en una que, un cop acabat el circuit, tornen al lloc d'on hansortit. Per donar un producte per bo, es realitzen tests de diverses hores i se n'obté unaestadística de lectures bones/dolentes. Si la ràtio és la desitjada es dóna per bo elproducte.Per aconseguir un disseny correcte s'ha utilitzat diferents eines CAD per dimensionar elsistema de transportadors i els seus elements. Tota l'aplicació està realitzada en 3Dmitjançant el software AutoCAD 3D. L'abast d'aquest projecte inclourà la solució mecànica i pneumàtica del sistema, aixícom el seu muntatge i tot el referent a les normes de seguretat per tal que el sistemacompleixi la normativa referida a la seguretat de màquines
Resumo:
Breu descripció del funcionament d"un sistema RFID, de les seves aplicacions en biblioteques, i dels problemes i limitacions que té.
Dynamic single cell measurements of kinase activity by synthetic kinase activity relocation sensors.
Resumo:
BACKGROUND: Mitogen activated protein kinases (MAPK) play an essential role in integrating extra-cellular signals and intra-cellular cues to allow cells to grow, adapt to stresses, or undergo apoptosis. Budding yeast serves as a powerful system to understand the fundamental regulatory mechanisms that allow these pathways to combine multiple signals and deliver an appropriate response. To fully comprehend the variability and dynamics of these signaling cascades, dynamic and quantitative single cell measurements are required. Microscopy is an ideal technique to obtain these data; however, novel assays have to be developed to measure the activity of these cascades. RESULTS: We have generated fluorescent biosensors that allow the real-time measurement of kinase activity at the single cell level. Here, synthetic MAPK substrates were engineered to undergo nuclear-to-cytoplasmic relocation upon phosphorylation of a nuclear localization sequence. Combination of fluorescence microscopy and automated image analysis allows the quantification of the dynamics of kinase activity in hundreds of single cells. A large heterogeneity in the dynamics of MAPK activity between individual cells was measured. The variability in the mating pathway can be accounted for by differences in cell cycle stage, while, in the cell wall integrity pathway, the response to cell wall stress is independent of cell cycle stage. CONCLUSIONS: These synthetic kinase activity relocation sensors allow the quantification of kinase activity in live single cells. The modularity of the architecture of these reporters will allow their application in many other signaling cascades. These measurements will allow to uncover new dynamic behaviour that previously could not be observed in population level measurements.