613 resultados para RESTORATIONS
Recovering Streptococcus mutans over restorations by the tray technique: a randomized clinical study
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Here, we present a case report on prosthetic reconstruction of posterior teeth and composite resin restoration of anterior teeth yielding considerable esthetic improvement, reestablishment of disocclusion guides and function.
Resumo:
The success of rehabilitation will not depend on just clinical procedures. A proper dental technique (ceramist) is required as well as the respect for some biomimetic principles to obtain the desired final result. This study has the purpose of describing a prosthetic rehabilitation with laminate veneers and all-ceramic crowns of a patient unsatisfied with a previous esthetic treatment because of the negligence of some biomimetic principles. A 45-year-old female patient was admitted to the dental clinic complaining about the lifelike appearance of her all-ceramic restorations. Before the fabrication of new restorations, a mock-up was conducted to verify the patient's satisfaction. A ceramist conducted all the fabrication process so that surface characterizations could be visually verified and the lifelike appearance of natural tooth could be reproduced. After the cementation procedure, the patient reported being satisfied with the lifelike appearance of the new restorations. Based on the clinical findings of the present case report, it can be concluded that the reproduction of the lifelike esthetic appearance of natural teeth and the visualization of the final results before definitive procedures are essential to obtain the clinical success.
Resumo:
The aim of this prospective and blind clinical trial was to assess the effectiveness of sealing localized marginal defects of amalgam restoration that were initially scheduled to be replaced. A cohort of twenty six patients with 60 amalgam restorations (n=44Class I and n=16Class II), that presented marginal defects deviating from ideal (Bravo) according to USPHS criteria, were assigned to either sealing or replacement groups: A: sealing n=20, Replacement n=20, and no treatment (n=20). Two blind examiners evaluated the restorations at baseline (K=0.74) and after ten years (K=0.84) according with USPHS criteria, in four parameters: marginal adaptation (MA), secondary caries (SC), marginal staining (MS) and teeth sensitivity (TS). Multiple comparison of restorations degradation/upgrade was analyzed by Friedman test and the comparisons within groups were performed by Wilcoxon test. After 10 years, 44 restorations were assessed (73.3%), Group A: n=14 and Group B: n=16; and Group C: n=14 sealing and replacement amalgam restorations presented similar level of quality in MA (p=0.76), SC (p=0.25) and TS (p=0.52), while in MS (p=0.007) presented better performance in replacement group after 10-years. Most of the occlusal amalgam restorations with marginal gaps showed similar long term outcomes than the restorations were sealed, replaced, or not treated over a 10-year period. Most of the restorations of the three groups were clinically acceptable, under the studied parameters. All restorations had the tendency to present downgrade/deterioration over time.
Resumo:
AIM: The aim of this study is to present a clinical case in which an occlusal matrix device was used in a patient who needed to restore a posterior tooth. MATERIAL AND METHODS: A direct duplicate occlusal appliance was used (biteperf) in a patient who needed an occlusal restoration in two posterior teeth. RESULTS: Using the matrix helps having fast and accurate reproduction of the original anatomical details of the occlusal surface. The final result surprised with the presented restoration in terms of esthetic quality, despite the simplicity of the technique. CONCLUSION: Posterior teeth with initial lesions were confined to the occlusal surface of anatomically complex or fissured anatomy with or without signs of proximal caries wich are ideal candidates for this technique. The overlying enamel surface must be relatively intact; lesions of hidden or occult caries. CLINICAL SIGNIFICANCE: The aesthetic and time-saving benefits of the occlusal device (biteperf) are immediately clear. The matrix allows the fast and accurate reproduction of the anatomic details of the original occlusal surface of the tooth. The professionals who lack an artistic penchant and marked manual ability will be able to carry out excellent posterior resin composite restorations.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objectives. The C-Factor has been used widely to rationalize the changes in shrinkage stress occurring at the tooth/resin-composite interfaces. Experimentally, such stresses have been measured in a uniaxial direction between opposed parallel walls. The situation of adjoining cavity walls has been neglected. The aim was to investigate the hypothesis that: within stylized model rectangular cavities of constant volume and wall thickness, the interfacial shrinkage-stress at the adjoining cavity walls increases steadily as the C-Factor increases. Methods. Eight 3D-FEM restored Class I 'rectangular cavity' models were created by MSC.PATRAN/MSC.Marc, r2-2005 and subjected to 1% of shrinkage, while maintaining constant both the volume (20 mm(3)) and the wall thickness (2 mm), but varying the C-Factor (1.9-13.5). An adhesive contact between the composite and the teeth was incorporated. Polymerization shrinkage was simulated by analogy with thermal contraction. Principal stresses and strains were calculated. Peak values of maximum principal (MP) and maximum shear (MS) stresses from the different walls were displayed graphically as a function of C-Factor. The stress-peak association with C-Factor was evaluated by the Pearson correlation between the stress peak and the C-Factor. Results. The hypothesis was rejected: there was no clear increase of stress-peaks with C-Factor. The stress-peaks particularly expressed as MP and MS varied only slightly with increasing C-Factor. Lower stress-peaks were present at the pulpal floor in comparison to the stress at the axial walls. In general, MP and MS were similar when the axial wall dimensions were similar. The Pearson coefficient only expressed associations for the maximum principal stress at the ZX wall and the Z axis. Significance. Increase of the C-Factor did not lead to increase of the calculated stress-peaks in model rectangular Class I cavity walls. (C) 2011 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
Objective: This study evaluated the 56-month clinical performance of Class I and II resin composite restorations. Filtek P60 was compared with Filtek Z250, which are both indicated for posterior restorations but differ in terms of handling characteristics. The null hypothesis tested was that there is no difference in the clinical performance of the two resin composites in posterior teeth. Material and Methods: Thirty-three patients were treated by the same operator, who prepared 48 Class I and 42 Class II cavities, which were restored with Single Bond/Filtek Z250 or Single Bond/Filtek P60 restorative systems. Restorations were evaluated by two independent examiners at baseline and after 56 months, using the modified USPHS criteria. Data were analyzed statistically using Chi-square and Fisher's Exact tests (alpha=0.05). Results: After 56 months, 25 patients (31 Class I and 36 Class II) were analyzed. A 3% failure rate occurred due to secondary caries and excessive loss of anatomic form for P60. For both restorative systems, there were no significant differences in secondary caries and postoperative sensitivity. However, significant changes were observed with respect to anatomic form, marginal discoloration, and marginal adaptation. Significant decreases in surface texture were observed exclusively for the Z250 restorations. Conclusions: Both restorative systems can be used for posterior restorations and can be expected to perform well in the oral environment.
Resumo:
Objective: The flexural strength and the elastic modulus of acrylic resins, Dencor, Duralay and Trim Plus II, were evaluated with and without the addition of silanised glass fibre. Materials and methods: To evaluate the flexural strength and elastic modulus, 60 test specimens were fabricated with the addition of 10% ground silanised glass fibres for the experimental group, and 60 without the incorporation of fibres, for the control group, with 20 test specimens being made of each commercial brand of resin (Dencor, Duralay and Trim Plus II) for the control group and experimental group. After the test specimens had been completed, the flexural strength and elastic modulus tests were performed in a universal testing device, using the three-point bending test. For the specimens without fibres the One-Way Analysis of Variance and the complementary Tukey test were used, and for those with fibres it was not normal, so that the non-parametric Mann-Whitney test was applied. Results: For the flexural strength test, there was no statistical difference (p > 0.05) between each commercial brand of resin without fibres [Duralay 84.32(+/- 8.54), Trim plus 85.39(+/- 6.74), Dencor 96.70(+/- 6.52)] and with fibres (Duralay 87.18, Trim plus 88.33, Dencor 98.10). However, for the elastic modulus, there was statistical difference (p > 0.01) between each commercial brand of resin without fibres [Duralay 2380.64 (+/- 168.60), Trim plus 2740.37(+/- 311.74), Dencor 2595.42(+/- 261.22)] and with fibres (Duralay 3750.42, Trim plus 3188.80, Dencor 3400.75). Conclusion: The result showed that the incorporation of fibre did not interfere in the flexural strength values, but it increased the values for the elastic modulus.
Resumo:
In this study we compared the microleakage of conventional glass ionomer cement (GIC) restorations following the use of different methods of root caries removal. In vitro root caries were induced in 75 human root dentin samples that were divided in five groups of 15 each according to the method used for caries removal: in group 1 spherical carbide burs at low speed were used, in group 2 a hand-held excavator was used, and in groups 3 to 5 an Er,Cr:YSGG laser was used at 2.25 W, 40.18 J/cm(2) (group 3), 2.50 W, 44.64 J/cm(2) (group 4) and 2.75 W, 49.11 J/cm(2) (group 5). The air/water cooling during irradiation was set to 55%/65% respectively. All cavities were filled with GIC. Five samples from each group were evaluated by scanning electron microscopy (SEM) and the other ten samples were thermocycled and submitted to a microleakage test. The data obtained were compared by ANOVA followed by Fisher's test (pa parts per thousand currency sign0.05). Group 4 showed the lowest microleakage index (56.65 6.30; p < 0.05). There were no significant differences among the other groups. On SEM images samples of groups 1 and 2 showed a more regular interface than the irradiated samples. Demineralized dentin below the restoration was observed, that was probably affected dentin. Group 4 showed the lowest microleakage values compared to the other experimental groups, so under the conditions of the present study the method that provided the lowest microleakage was the Er,Cr:YSGG laser with a power output of 2.5 W yielding an energy density of 44.64 J/cm(2).
Resumo:
Direct composite resin restorations have become a viable alternative for patients that require anterior restorative procedures to be integrated to the other teeth that compose the smile, especially for presenting satisfactory esthetic results and minimum wear of the dental structure. Technological evolution along with a better understanding of the behavior of dental tissues to light incidence has allowed the development of new composite resins with better mechanical and optical properties, making possible a more artistic approach for anterior restorations. The combination of the increasing demand of patients for esthetics and the capacity to preserve the dental structure resulted in the development of different incremental techniques for restoring fractured anterior teeth in a natural way. In order to achieve esthetic excellence, dentists should understand and apply artistic and scientific principles when choosing color of restorative materials, as well as during the insertion of the composite resin. The discussion of these strategies will be divided into two papers. In this paper, the criteria for color and material selection to obtain a natural reproduction of the lost dental structures and an imperceptible restoration will be addressed.
Resumo:
This study evaluated the performance of the DIAGNOdent pen laser fluorescence device (LFpen) in comparison with visual examination (VE), bitewing radiographs (BW) and visual examination combined with bitewing radiographs (VEBW) in detecting secondary approximal caries associated with composite restorations. In total, 60 approximal surfaces from 43 permanent molars with composite restorations were assessed twice by two examiners using the LFpen, VE, BW and VEBW. After histological preparation and hardness measurements, the sample was assigned to either a crown or root caries group, depending on the location of the lesions as the gold standard. For crown caries at D1, the highest values of specificity and sensitivity were observed for the LFpen at a cutoff value of 18 (1.00) and for the VEBW (0.89). At D3 (cutoff of 30), the LFpen showed the highest values of sensitivity and specificity. For root caries, the LFpen and VEBW showed the highest values of specificity (0.54), sensitivity (0.81) and accuracy (0.69). The Spearman rank correlation coefficients for crown/root caries with histology were 0.54/0.37 (LFpen), 0.29/0.10 (BW), 0.29/0.18 (VE) and 0.23/0.37 (VEBW). For the LFpen, the ICC varied from 0.80 (interexaminer) to 0.97 (intraexaminer B); the kappa value was 0.19 for BW and 0.35 for VE (interexaminer). Intraexaminer kappa values for BW were 0.25 (A) and 0.29 (B), and those for VE were 0.31 (A) and 0.32 (B). The LFpen device exhibited a performance comparable to that of conventional methods but with higher interexaminer reproducibility. Therefore, the LFpen should be considered an auxiliary method for the detection of secondary approximal caries associated with composite restorations.
Resumo:
This in vitro study evaluated the performance of three ceramic and two commonly used polishing methods on two CAD/CAM ceramics. Surface roughness and quality were compared. A glazed group (GLGR) of each ceramic material served as reference. One-hundred and twenty specimens of VITABLOCS Mark II (VITA) and 120 specimens of IPS Empress CAD (IPS) were roughened in a standardized manner. Twenty VITA and 20 IPS specimens were glazed (VITA Akzent Glaze/Empress Universal Glaze). Five polishing methods were investigated (n=20/group): 1) EVE Diacera W11DC-Set (EVE), 2) JOTA 9812-Set (JOTA), 3) OptraFine-System (OFI), 4) Sof-Lex 2382 discs (SOF) and 5) Brownie/Greenie/Occlubrush (BGO). Polishing quality was measured with a surface roughness meter (Ra and Rz values). The significance level was set at alpha=0.05. Kruskal Wallis tests and pairwise Wilcoxon rank sum tests with Bonferroni-Holm adjustment were used. Qualitative surface evaluation of representative specimens was done with SEM. On VITA ceramics, SOF produced lower Ra (p<0.00001) but higher Rz values than GLGR (p=0.003); EVE, JOTA, OFI and BGO yielded significantly higher Ra and Rz values than GLGR. On IPS ceramics, SOF and JOTA exhibited lower Ra values than GLGR (p<0.0001). Equivalent Ra but significantly higher Rz values occurred between GLGR and EVE, OFI or BGO. VITA and IPS exhibited the smoothest surfaces when polished with SOF. Nevertheless, ceramic polishing systems are still of interest to clinicians using CAD/CAM, as these methods are universally applicable and showed an increased durability compared to the investigated silicon polishers.
Resumo:
Because the recommendation to use flowables for posterior restorations is still a matter of debate, the objective of this study was to determine in a nationwide survey in Germany how frequently, for what indications, and for what reasons, German dentists use flowable composites in posterior teeth. In addition, the acceptance of a simplified filling technique for posterior restorations using a low stress flowable composite was evaluated. Completed questionnaires from all over Germany were returned by 1,449 dentists resulting in a response rate of 48.5%; 78.6% of whom regularly used flowable composites for posterior restorations. The most frequent indications were cavity lining (80.1%) and small Class I fillings (74.2%). Flowables were less frequently used for small Class II fillings (22.7%) or other indications (13.6%). Most frequent reasons given for the use of flowables in posterior teeth were the prevention of voids (71.7%) and superior adaptation to cavity walls (72.9%), whereas saving time was considered less important (13.8%). Based on the subjective opinion of the dentists the simplified filling technique seemed to deliver advantages compared to the methods used to date particularly with regard to good cavity adaptation and ease of use. In conclusion, resin composites are the standard material type used for posterior restorations by general dental practitioners in Germany and most dentists use flowable composites as liners.