904 resultados para RESIN-BASED COMPOSITE


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Currently, well established clinical therapeutic approaches for bone reconstruction are restricted to the transplantation of autografts and allografts, and the implantation of metal devices or ceramic-based implants to assist bone regeneration. Bone grafts possess osteoconductive and osteoinductive properties, their application, however, is associated with disadvantages. These include limited access and availability, donor site morbidity and haemorrhage, increased risk of infection, and insufficient transplant integration. As a result, recent research focuses on the development of complementary therapeutic concepts. The field of tissue engineering has emerged as an important alternative approach to bone regeneration. Tissue engineering unites aspects of cellular biology, biomechanical engineering, biomaterial sciences and trauma and orthopaedic surgery. To obtain approval by regulatory bodies for these novel therapeutic concepts the level of therapeutic benefit must be demonstrated rigorously in well characterized, clinically relevant animal models. Therefore, in this PhD project, a reproducible and clinically relevant, ovine, critically sized, high load bearing, tibial defect model was established and characterized as a prerequisite to assess the regenerative potential of a novel treatment concept in vivo involving a medical grade polycaprolactone and tricalciumphosphate based composite scaffold and recombinant human bone morphogenetic proteins.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: To examine the association between individual- and neighborhood-level disadvantage and self-reported arthritis. Methods: We used data from a population-based cross-sectional study conducted in 2007 among 10,757 men and women ages 40–65 years, selected from 200 neighborhoods in Brisbane, Queensland, Australia using a stratified 2-stage cluster design. Data were collected using a mail survey (68.5% response). Neighborhood disadvantage was measured using a census-based composite index, and individual disadvantage was measured using self-reported education, household income, and occupation. Arthritis was indicated by self-report. Data were analyzed using multilevel modeling. Results: The overall rate of self-reported arthritis was 23% (95% confidence interval [95% CI] 22–24). After adjustment for sociodemographic factors, arthritis prevalence was greatest for women (odds ratio [OR] 1.5, 95% CI 1.4–1.7) and in those ages 60–65 years (OR 4.4, 95% CI 3.7–5.2), those with a diploma/associate diploma (OR 1.3, 95% CI 1.1–1.6), those who were permanently unable to work (OR 4.0, 95% CI 3.1–5.3), and those with a household income <$25,999 (OR 2.1, 95% CI 1.7–2.6). Independent of individual-level factors, residents of the most disadvantaged neighborhoods were 42% (OR 1.4, 95% CI 1.2–1.7) more likely than those in the least disadvantaged neighborhoods to self-report arthritis. Cross-level interactions between neighborhood disadvantage and education, occupation, and household income were not significant. Conclusion: Arthritis prevalence is greater in more socially disadvantaged neighborhoods. These are the first multilevel data to examine the relationship between individual- and neighborhood-level disadvantage upon arthritis and have important implications for policy, health promotion, and other intervention strategies designed to reduce the rates of arthritis, indicating that intervention efforts may need to focus on both people and places.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Increasing attention has been focused on methods that deliver pharmacologically active compounds (e.g. drugs, peptides and proteins) in a controlled fashion, so that constant, sustained, site-specific or pulsatile action can be attained. Ion-exchange resins have been widely studied in medical and pharmaceutical applications, including controlled drug delivery, leading to commercialisation of some resin based formulations. Ion-exchangers provide an efficient means to adjust and control drug delivery, as the electrostatic interactions enable precise control of the ion-exchange process and, thus, a more uniform and accurate control of drug release compared to systems that are based only on physical interactions. Unlike the resins, only few studies have been reported on ion-exchange fibers in drug delivery. However, the ion-exchange fibers have many advantageous properties compared to the conventional ion-exchange resins, such as more efficient compound loading into and release from the ion-exchanger, easier incorporation of drug-sized compounds, enhanced control of the ion-exchange process, better mechanical, chemical and thermal stability, and good formulation properties, which make the fibers attractive materials for controlled drug delivery systems. In this study, the factors affecting the nature and strength of the binding/loading of drug-sized model compounds into the ion-exchange fibers was evaluated comprehensively and, moreover, the controllability of subsequent drug release/delivery from the fibers was assessed by modifying the conditions of external solutions. Also the feasibility of ion-exchange fibers for simultaneous delivery of two drugs in combination was studied by dual loading. Donnan theory and theoretical modelling were applied to gain mechanistic understanding on these factors. The experimental results imply that incorporation of model compounds into the ion-exchange fibers was attained mainly as a result of ionic bonding, with additional contribution of non-specific interactions. Increasing the ion-exchange capacity of the fiber or decreasing the valence of loaded compounds increased the molar loading, while more efficient release of the compounds was observed consistently at conditions where the valence or concentration of the extracting counter-ion was increased. Donnan theory was capable of fully interpreting the ion-exchange equilibria and the theoretical modelling supported precisely the experimental observations. The physico-chemical characteristics (lipophilicity, hydrogen bonding ability) of the model compounds and the framework of the fibrous ion-exchanger influenced the affinity of the drugs towards the fibers and may, thus, affect both drug loading and release. It was concluded that precisely controlled drug delivery may be tailored for each compound, in particularly, by choosing a suitable ion-exchange fiber and optimizing the delivery system to take into account the external conditions, also when delivering two drugs simultaneously.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this study was to evaluate the feasibility of pit and fissure sealants and the effectiveness of the two sealant methods applied in every-day practice in public dental health care in Finland. Two sealant methods were evaluated according to their effectiveness in preventing dentin caries and sealant retention. Application time with these sealant methods was compared. The survival rate of sealed first and second molars was followed for nine and 13 year periods, respectively. Caries risk evaluation and observed increased caries risk were the basis for considering sealant application. A questionnaire, sent to all public dental health centers in Finland, monitored the attitudes of the dental profession towards sealant application and explored the current policies used as well as changes noted in the sealant application protocol. DMFT (Decayed, Missing or Filled Teeth) index values collected from the health centers were evaluated. The difference in caries rate between two methods investigated was highly significant. When compared to the glass ionomer sealant method (GIC), the effectiveness of the resin-based method (RB) in preventing dentin caries was 74% and the rate difference 3%. The relative risk for RB-sealed surfaces vs. GIC-sealed surfaces of having detectable dentin caries was 0.3 (95% CI 0.12, 0.57). The retention rate of sealants was higher with RB than GIC (P<0.001). Application of RB sealant material was less time-consuming than application of GIC sealant. Occlusal dentin caries lesions were found in 4% and proximal caries in less than 2% of sealed teeth. The majority of respondents reported application of sealants on a systematic basis along with caries-risk evaluation. Those health centers sealing over suspected or detected enamel caries had lower average DMFT index values (1.0) when compared to DMFT values (1.2) of health centers applying sealants by alternative criteria. It is concluded that the RB sealant method is more effective than the GIC sealant method in preventing dentin caries. Sealant maintenance may increase the costs of a sealant program. Occlusal caries management may be improved if the applied sealant policies are changed towards an interceptive approach i.e. applying the sealants over detected or suspected enamel caries lesions instead of sealing sound teeth in a preventive manner.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Mesoporous beta-MnO2 has been prepared, characterized and demonstrated to possess excellent catalytic activity in the thermal decomposition of ammonium perchlorate. The observed unprecedentedly low decomposition temperatures, fast reaction rates and enhanced heat releases in the catalysed formulations make mesoporous beta-MnO2 promising as a high-performing ballistic modifier in AP-based composite solid rocket propellants.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O objetivo desta pesquisa consiste em analisar através da caracterização química de fases cristalinas a composição e estrutura; e com a caracterização física a densidade, porosidade e área superficial dos seguintes cimentos endodônticos: MTA Fillapex, AH Plus, Sealer 26 e o Endofill. Para tal, foram realizadas análises dos cimentos antes da manipulação (pó e pastas) e depois da manipulação (corpos de prova). Empregando-se as técnicas de caracterização química: DRX e FRX e como técnicas de caracterização física: Picnometria de Hélio, a porosimetria de mercúrio, distribuição granulométrica e área superficial pela metodologia de BET. A caracterização química detalhou a composição dos cimentos sendo compatível com a descrição do fabricante e forneceu a quantificação das suas fases. A caracterização física mostrou que o MTA Fillapex apresentou os melhores resultados: a menor porosidade, o menor volume médio e o menor diâmetro do poro, o Sealer 26 dentre os cimentos resinosos apresentou o pior resultado, o Endofill mostrou-se melhor que o Sealer 26 tendo a maior densidade, o menor diâmetro das partículas, a distribuição granulométrica mais homogênea comparando-se a este. Os cimentos a base de resina mostraram um diâmetro do poro menor que o Endofill. Estes resultados podem estar ligados diretamente aos requisitos de um material obturador ideal. A metodologia utilizada produziu um detalhamento das características químicas e físicas dos cimentos estudados, mostrando um caminho para novas pesquisas na área.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Resinas macias para reembasamento de próteses são largamente utilizadas após cirurgias para estabilizarem a prótese e condicionarem o tecido, aguardando a completa cicatrização. É importante que o material não seja facilmente colonizado por biofilme oral e se possível, evite a contaminação do sítio cirúrgico. Objetivou-se avaliar o efeito da incorporação de clorexidina às resinas acrílicas macias para o reembasamento de próteses totais, através de análises de liberação, citotoxicidade e efeito inibitório de um biofilme de C. albicans. Foram confeccionados corpos de provas (CDPs) com as resinas Trusoft e Coe-soft, com incorporação de 0%, 0,5%, 1,0% e 2,0% de clorexidina, totalizando 8 grupos. A liberação de clorexidina foi avaliada através da mensuração da mudança na densidade óptica da solução de armazenamento, na qual ficaram imersos os CDPs, por espectrometria UV, a cada 48 horas, durante 40 dias. A citotoxicidade celular foi avaliada em fibroblastos (linhagem L929), que ficaram 24 horas em contato com meio de cultura no qual os CDPs ficaram previamente imersos, pela técnica de absorção de corante vermelho neutro após 24, 48 e 72 horas e semanalmente até o 28 dia. E, por fim, a atividade antifúngica contra a C. albicans (ATCC 10231) foi avaliada de duas maneiras: (1) teste de difusão em ágar, no qual os CDPs foram colocados em placas de BHI previamente inoculadas com C. albicans, com medição do halo de inibição após 48 horas de incubação a 37C; (2) a avaliação da inibição da formação de um biofilme de C. albicans sobre a superfície dos CDPs pela quantificação por metil tetrazólio (MTT) a cada 48 horas, durante 22 dias, com leitura feita em espectrofotômetro de UV. Os dados obtidos foram inseridos no programa SigmaStat (versão 3.1, USA) para realizar as análises estatísticas. As diferenças estatísticas foram determinadas por análises de variâncias do tipo ANOVA e todos os procedimentos para comparações múltiplas pareadas foram feitos utilizando-se o método Holm-Sidak, com nível de significância global igual a 0,05. A clorexidina adicionada às resinas testadas foi capaz de ser liberada para o meio de armazenagem, proporcionalmente à quantidade de clorexidina incorporada, porém com diferentes cinéticas de liberação entre as resinas, visto que a Trusoft libera até 71% do total de clorexidina liberada nas primeiras 48 horas e a Coe-soft, até 44%. Ambas as resinas com incorporação de clorexidina apresentaram efeito citotóxico adicional, se comparadas às resinas sem clorexidina, porém para a Coe-soft não houve diferença estatística dos valores, apenas para a Trusoft (p<0,001). Ocorreu formação de halo de inibição proporcionalmente às concentrações de resinas adicionadas, com maiores halos para a resina Trusoft (p<0,001), e sem formação de halo para as resinas sem clorexidina; a inibição da formação de biofilme, realizada somente com a resina Coe-soft, mostrou total inibição durante 8, 12 e 16 dias, para a incorporação de 0,5%, 1,0% e 2,0% respectivamente, sendo uma diminuição estatisticamente significativa (p<0,001) em relação à resina sem incorporação de clorexidina, que não apresentou inibição do biofilme.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

基于内容的Pub/Sub系统能够为大范围软件集成提供松耦合的、可扩展的集成能力,越来越引起人们的重视.现存的方法主要集中在对单一事件的匹配,缺乏对复合事件模型及其订阅语言的研究.针对此问题,文章给出一种基于XML事件的复合事件模型及其订阅语言,该模型包括事件时序逻辑模型和事件复合模式,并扩展了XML—QL语言得到复合事件订阅语言EXML—QL支持事件复合模型和模式;最后,依据该订阅语言的特点构造复合事件匹配算法,给出该算法的分析和验证.