789 resultados para REMODELACIÓN ATRIAL


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Atrial fibrillation (AF) ablation has evolved to the treatment of choice for patients with drug-resistant and symptomatic AF. Pulmonary vein isolation at the ostial or antral level usually is sufficient for treatment of true paroxysmal AF. For persistent AF ablation, drivers and perpetuators outside of the pulmonary veins are responsible for AF maintenance and have to be targeted to achieve satisfying arrhythmia-free success rate. Both complex fractionated atrial electrogram (CFAE) ablation and linear ablation are added to pulmonary vein isolation for persistent AF ablation. Nevertheless, ablation failure and necessity of repeat ablations are still frequent, especially after persistent AF ablation. Pulmonary vein reconduction is the main reason for arrhythmia recurrence after paroxysmal and to a lesser extent after persistent AF ablation. Failure of persistent AF ablation mostly is a consequence of inadequate trigger ablation, substrate modification or incompletely ablated or reconducting linear lesions. In this review we will discuss these points responsible for AF recurrence after ablation and review current possibilities on how to overcome these limitations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coronary artery disease (CAD) and atrial fibrillation (AF) are major determinants of morbidity and mortality. A combined treatment with antiplatelet agents and vitamin K antagonists limits the risk of stent thrombosis and stroke while increasing the rate of bleeding. The objective of this study was to investigate the impact of atrial fibrillation (AF) on long-term clinical outcomes in patients with CAD undergoing percutaneous coronary intervention (PCI) with drug-eluting stents (DES).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Detection of arrhythmic atrial beats in surface ECGs can be challenging when they are masked by the R or T wave, or do not affect the RR-interval. Here, we present a solution using a high-resolution esophageal long-term ECG that offers a detailed view on the atrial electrical activity. The recorded ECG shows atrial ectopic beats with long coupling intervals, which can only be successfully classified using additional morphology criteria. Esophageal high-resolution ECGs provide this information, whereas surface long-term ECGs show poor atrial signal quality. This new method is a promising tool for the long-term rhythm monitoring with software-based automatic classification of atrial beats.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During follow-up of between 1 and 3 years in the Randomized Evaluation of Long-term Anticoagulation Therapy (RE-LY) trial, 2 doses of dabigatran etexilate were shown to be effective and safe for the prevention of stroke or systemic embolism in patients with atrial fibrillation. There is a need for longer-term follow-up of patients on dabigatran and for further data comparing the 2 dabigatran doses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Atrial tissue expresses both connexin 40 (Cx40) and 43 (Cx43) proteins. To assess the relative roles of Cx40 and Cx43 in atrial electrical propagation, we synthesized cultured strands of atrial myocytes derived from mice with genetic deficiency in Cx40 or Cx43 expression and measured propagation velocity (PV) by high-resolution optical mapping of voltage-sensitive dye fluorescence. The amount of Cx40 and/or Cx43 in gap junctions was measured by immunohistochemistry and total or sarcolemmal Cx43 or Cx40 protein by immunoblotting. Progressive genetic reduction in Cx43 expression decreased PV from 34+/-6 cm/sec in Cx43(+/+) to 30+/-8 cm/sec in Cx43(+/-) and 19+/-11 cm/sec in Cx43(-/-) cultures. Concomitantly, the cell area occupied by Cx40 immunosignal in gap junctions decreased from 2.0+/-1.6% in Cx43(+/+) to 1.7+/-0.5% in Cx43(+/-) and 1.0+/-0.2% in Cx43(-/-) strands. In contrast, progressive genetic reduction in Cx40 expression increased PV from 30+/-2 cm/sec in Cx40(+/+) to 40+/-7 cm/sec in Cx40(+/-) and 45+/-10 cm/sec in Cx40(-/-) cultures. Concomitantly, the cell area occupied by Cx43 immunosignal in gap junctions increased from 1.2+/-0.9% in Cx40(+/+) to 2.8+/-1.4% in Cx40(+/-) and 3.1+/-0.6% in Cx40(-/-) cultures. In accordance with the immunostaining results, immunoblots of the Triton X-100-insoluble fraction revealed an increase of Cx43 in gap junctions in extracts from Cx40-ablated atria, whereas total cellular Cx43 remained unchanged. Our results suggest that the relative abundance of Cx43 and Cx40 is an important determinant of atrial impulse propagation in neonatal hearts, whereby dominance of Cx40 decreases and dominance of Cx43 increases local propagation velocity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Patients late after open-heart surgery may develop dual-loop reentrant atrial arrhythmias, and mapping and catheter ablation remain challenging despite computer-assisted mapping techniques. Objectives The purpose of the study was to demonstrate the prevalence and characteristics of dual-loop reentrant arrhythmias, and to define the optimal mapping and ablation strategy. Methods Fourty consecutive patients (mean age 52+/-12 years) with intra-atrial reentrant tachycardia (IART) after open-heart surgery (with an incision of the right atrial free wall) were studied. Dual-loop IART was defined as the presence of two simultaneous atrial circuits. Following an abrupt tachycardia change during radiofrequency (RF) ablation, electrical disconnection of the targeted reentry isthmus from the remaining circuit was demonstrated by entrainment mapping. Furthermore, the second circuit loop was localized using electroanatomic mapping and/or entrainment mapping. Results Dual-loop IART was demonstrated in 8 patients (20%, 5 patients with congenital heart disease, 3 with acquired heart disease). Dual-loop IART included an isthmus-dependant atrial flutter combined with a reentry related to the atriotomy scar. The diagnosis of dual-loop IART required the comparison of entrainment mapping before and after tachycardiamodification. Overall, 35 patients had successful RF ablation (88%). Success rates were lower in patients with dual-loop IART than in patient without dual-loop IART. Ablation failures in 3 patients with dual-loop IART were related to the inability to properly transect the second tachycardia isthmus in the right atrial free wall. Conclusions Dual-loop IART is relatively common after heart surgery involving a right atriotomy. Abrupt tachycardia change and specific entrainment mapping maneuvers demonstrate these circuits. Electroanatomic mapping appears to be important to assist catheter ablation of periatriotomy circuits.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Iatrogenic atrial septal defects are described in 2 patients. They occurred after implantation of Amplatzer occluders to close a patent foramen ovale. While device erosions to the extra-atrial space have been described, erosion induced atrial septal defects are a new medical entity. They may be fairly common in the situation of an atrial septal aneurysm whipping the rim of the device incessantly. They are clinically silent and benign and require echocardiography for detection. A second device solved the problem in the cases described.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Myocardial dysfunction and arrhythmias may be induced by congenital heart defects, but also be the result of heart surgery with cardiopulmonary bypass (CPB), potentially caused by differential expression of connexin40 (Cx40) and connexin43 (Cx43). In 16 pediatric patients undergoing corrective heart surgery, connexin mRNA expression was studied in volume overloaded (VO group, n=8) and not overloaded (NO group, n=8) right atrial myocardium, excised before and after CPB. Additionally, in eight of these patients ventricular specimens were investigated. The atrial Cx43 expression decreased during CPB, which was restricted to the VO group (p=0.008). In contrast, atrial Cx40 mRNA did not change during CPB. In ventricular myocardium compared to atrial mRNA levels, Cx40 was lower (p=0.006) and Cx43 higher (p=0.017) expressed, without significant change during CPB. This study revealed a significant influence of CPB and the underlying heart defect on Cx43 expression.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Current concepts of catheter ablation for atrial fibrillation (AF) commonly use three-dimensional (3D) reconstructions of the left atrium (LA) for orientation, catheter navigation, and ablation line placement. OBJECTIVES: The purpose of this study was to compare the 3D electroanatomic reconstruction (Carto) of the LA, pulmonary veins (PVs), and esophagus with the true anatomy displayed on multislice computed tomography (CT). METHODS: In this prospective study, 100 patients undergoing AF catheter ablation underwent contrast-enhanced spiral CT scan with barium swallow and subsequent multiplanar and 3D reconstructions. Using Carto, circumferential plus linear LA lesions were placed. The esophagus was tagged and integrated into the Carto map. RESULTS: Compared with the true anatomy on CT, the electroanatomic reconstruction accurately displayed the true distance between the lower PVs; the distances between left upper PV, left lower PV, right lower PV, and center of the esophagus; the longitudinal diameter of the encircling line around the funnel of the left PVs; and the length of the mitral isthmus line. Only the distances between the upper PVs, the distance between the right upper PV and esophagus, and the diameter of the right encircling line were significantly shorter on the electroanatomic reconstructions. Furthermore, electroanatomic tagging of the esophagus reliably visualized the true anatomic relationship to the LA. On multiple tagging and repeated CT scans, the LA and esophagus showed a stable anatomic relationship, without relevant sideward shifting of the esophagus. CONCLUSION: Electroanatomic reconstruction can display with high accuracy the true 3D anatomy of the LA and PVs in most of the regions of interest for AF catheter ablation. In addition, Carto was able to visualize the true anatomic relationship between the esophagus and LA. Both structures showed a stable anatomic relationship on Carto and CT without relevant sideward shifting of the esophagus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The presence of irreversible pulmonary hypertension in patients with atrial septal defect (ASD) is thought to preclude shunt closure. We report the case of a woman with plexiform pulmonary arteriopathy secondary to an ostium secundum ASD who was able to successfully undergo percutaneous shunt closure following therapy with chronic intravenous prostacyclin (Flolan). One year after closure, the patient was weaned off Flolan over a period of 7 months following the institution of oral Bosentan therapy. Our case illustrates how aggressive vasodilator therapy with prostaglandins may be capable of reducing pulmonary artery pressure and permitting shunt closure in a patient once considered to have "inoperable" pulmonary arteriopathy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: For patients having suffered ischemic stroke, the current diagnostic strategies often fail to detect atrial fibrillation as a potential cause of embolic events. The aim of the study was to identify paroxysmal atrial fibrillation in stroke patients. We hypothesized that patients with frequent atrial premature beats (APBs) recorded in 24-hour ECG will show more often atrial fibrillation when followed by repeated long-term ECG recordings than patients without or infrequent APBs. METHODS: 127 patients with acute ischemic stroke and without known AF were enrolled in a prospective study to detect paroxysmal AF. Patients were stratified according to the number of APBs recorded in a 24-hour ECG (> or =70 APBs versus <70 APBs). Subsequently, they all underwent serial 7-day event-recorder monitoring at 0, 3, and 6 months. RESULTS: Serial extended ECG monitoring identified AF in 26% of patients with frequent APBs but only in 6.5% when APBs were infrequent (P=0.0021). A multivariate analysis showed that the presence of frequent APBs in the initial 24-hour ECG was the only independent predictor of paroxysmal AF during follow-up (odds ratio 6.6, 95% confidence intervals 1.6 to 28.2, P=0.01). CONCLUSIONS: In patients with acute ischemic stroke, frequent APBs (> or = 70/24 hours) are a marker for individuals who are at greater risk to develop or have paroxysmal AF. For such patients, we propose a diagnostic workup with repeated prolonged ECG monitoring to diagnose paroxysmal AF.