1000 resultados para Quantificação da espasticidade


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bupivacaine (S75-R25, NovaBupi®) is an amide type local anesthetic widely used. The present work consists of the development and validation of analytical methodology for evaluation of NovaBupi® content in the poly-lactide-co-glycolide nanospheres (PLGA-NS) by high performance liquid chromatography. The separation was made using the reversed-phase column LC-18, acetonitrile/phosphate buffer 85:15 v/v as mobile phase and detection at 220 nm. The results obtained show that the analytical methodology is accurate, reproducible, robust and linear over the concentration range 10-220.0 g/mL of NovaBupi®. The method was applied to determine the encapsulation efficiency and evaluate the release profile of NovaBupi®, showing good results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The lack of accuracy of a chromatographic method can be associated with the matrix effect. This effect is observed in pesticide quantification by gas chromatography when the chromatographic signals of standards prepared in solvents are compared with those of the analyte in extracts of complex matrices. In the competition between the matrix components and the pesticides for the active sites of the liner, a larger amount of pesticides is transferred to the column, giving apparent extractions above 100%. In this work, we discuss factors that contribute to the matrix effect and present some attempts to overcome the problem.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article describes an experiment designed to teach quantitative determination in gas chromatography (GC) in Organic and Analytical Chemistry practical classes. The experiment consisted of extracting and analyzing eugenol from clove seeds to perform a quantitative approach aimed at comparing results obtained by external and internal calibration procedures. Therefore, this experiment proved to be very effective tool to enhance students awareness on the need to understand different types of calibration in GC and on how to avoid common experimental errors, and to find the best ways to eliminate their interference during the quantitative analysis phase.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports the use of Raman and infrared techniques for the qualitative and quantitative analysis of plasticizers in polyvinylchloride (PVC) commercial films. FT-Raman marker bands were indentified for di-2-ethyl-hexyl adipate (DEHA) and di-2-ethyl-hexyl phthalate (DEHP), allowing for the rapid identification of these species in the commercial film. Quantitative analysis by FT-IR resulted in plasticizers concentrations ranging from 11 to 27% (w/w). Considering the little sample preparation and the low cost of the techniques, FT-IR and FT-Raman are viable techniques for a first assessment of plasticizers in commercial samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A phenolic fraction was obtained from of the acetone-water-acetic acid extract of Inga edulis leaves, by liquid-liquid partition and SPE-C18 cartridges. This method provided an increase of 108, 66, 51, 50 and 36% of flavonols, proanthocyanidins, total polyphenols, gallotannins and flavanols, respectively. The major phenolics in purified fraction were procyanidin B2, catechin and myricetin-3-O-α-L-rhamnopyranoside, which achieved increases of 111, 47 and 45%, respectively, after SPE. Acid hydrolysis confirmed the presence of procyanidins, prodelphinidins and glycosylated flavonoids.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work was studied composts and their humic acids (HA) to evaluate the use of EPR in the monitoring of the humification. It was observed increase in the concentration of organic free radical (OFR) in all the composts, but in L1 the increase was more significant than L2 and L3. Research more detailed of L1 showed that the lignin is main source of OFR. Then determination of these radicals in material in nature that contains high amount of lignin isn't a good indicator to monitor the humification process in the composting and yes the fraction HA of the composts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work reports the validation of an analytical UV spectrophotometric method to assay acyclovir in hydrophilic matrices (assay and dissolution studies). The method was linear in the range between 2.5-20 µg mL-1, presenting a good correlation coefficient ( r = 0,9999). Precision and accuracy analysis showed low relative standart deviation (< 2.0 %) and a good recoveries percentual (98.9-100 %). The procedure was linear, accurate, and robust. The method is simple and cheap. It does not use polluting reagents and can be applied in dissolution studies, being an adequate alternative to assay acyclovir in hydrophilic matrices tablets.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pulp hemicelluloses can be extracted with NaOH and quantified by colorimetric and gravimetric techniques. However the most usual methods to measure eucalyptus pulp hemicelluloses have been through the pentosan method or through xylan analyses by GC or HPLC techniques. In this study a comparison was made between the more traditional methods and indirect method of NaOH 5% extraction followed by colorimetric analyses. It was observed that the content of NaOH 5% extract correlates very well with pulp xylan content and reasonably well with the pentosan content. It is concluded that the 5% NaOH solubility method can be used in replacement of the other two, since it is faster, simpler and less costly to carry out than the others.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The measurement uncertainty is useful to estimate the confidence of analytical results. Nowadays, a result without the uncertainty statement cannot be considered reliable, but the scientific literature still lacks examples of the estimate of the measurement uncertainty. This paper presents a practical and reliable description of the measurement uncertainty estimation of the analytical determination of ethyl carbamate in cachaça by GC-IDMS. The isotope dilution technique (ID) associated with GC-MS was used to improve the accuracy. The uncertainty estimated corresponds to 10% of the mass fraction of ethyl carbamate (115 ± 11) ng/g, which is in agreement with ppb level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes the validation of a method for quantification of famotidine in capsules by UV spectrophotometry using as solvents buffer solution at pH 2.5 and buffer solution at pH 4.5. The results show that the method is practical, selective, accurate, precise and linear from 10.0 to 25.0 µg/mL of famotidine in both solvents. However, a variance analysis showed a lower mean percentage of famotidine when buffer at pH 2.5 is used. This effect was attributed to the instability of famotidine in acidic media. Therefore, the use of pH 4.5 buffer was considered suitable for analysis of famotidine in capsules.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An UV-Vis spectrophotometry analytical method for quantifying Efavirenz was developed and validated as an alternative to replace the HPLC current method. The report method presents sample concentration of 10 μg mL-1, dissolved in a solution ethanol:water (60:40, v/v), economic and technically adequate for the purpose adopted. The results and the statistical treated proved that the method being considered an precise and accurate analytical low cost alternative for laboratory routine. The adaptability of this method in product and other analytical methods development has been challenged by mathematical calculation of drug extinction coefficient in water and methanol and practical experiments, showing interesting results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present study was the evaluation of the presence of organic and inorganic contaminants in samples of aged cachaça from the South of the state of Minas Gerais. Furfural, methanol and copper were determined by colorimetric reactions, while the analyses of ethyl carbamate and acrolein were performed by GC/MS and HPLC, respectively. High levels of furfural and copper were obtained. All samples showed concentrations below the established by legislation for the ethyl carbamate, and for acrolein, only one sample showed higher levels. Methanol was not detected in the samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Antimony is a common catalyst in the synthesis of polyethylene terephthalate used for food-grade bottles manufacturing. However, antimony residues in final products are transferred to juices, soft drinks or water. The literature reports mentions of toxicity associated to antimony. In this work, a green, fast and direct method to quantify antimony, sulfur, iron and copper, in PET bottles by X-ray fluorescence spectrometry is presented. 2.4 to 11 mg Sb kg-1 were found in 20 samples analyzed. The coupling of the multielemental technique to chemometric treatment provided also the possibility to classify PET samples between bottle-grade PET/recycled PET blends by Fe content.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vitamin C, an exogenous antioxidant, is essential to human health. In this study, a method was validated to serum vitamin C quantification by HPLC-UV. Its stability with and without the use of tris [2-carboxy-ethyl] phosphine hydrochloride (TCEP), at -20 and -80 °C, in serum and supernatant were also evaluated. Analysis showed r² > 0.99, precision CV% < 15% and % bias < 15%, being linear, precise and accurate. The stability test revealed that using TCEP in serum storage at -20 and -80 °C or in supernatant at -80 °C the vitamin C levels remain stable for 30 and 12 days, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Interest in analytical methods for quality control of herbal drugs has grown sharply due to the scarcity of monographs in official manuals. Thus, the aim of the present study was to evaluate analytical procedures for quantitative determination of flavonoids from leaves of Bauhinia forficata Link (pata-de-vaca). Two procedures for quantification of total flavonoids (with and without acid hydrolysis) by spectrophotometry were tested. The proposed methods proved to be specific, sensitive, precise, accurate and robust, being suitable for routine laboratory use.