987 resultados para Pulse transit time
Resumo:
We report on direct experimental evidence of shot noise in a linear macroscopic resistor. The origin of the shot noise comes from the fluctuation of the total number of charge carriers inside the resistor associated with their diffusive motion under the condition that the dielectric relaxation time becomes longer than the dynamic transit time. The present results show that neither potential barriers nor the absence of inelastic scattering are necessary to observe shot noise in electronic devices.
Resumo:
Purpose: To assess the value of cerebral perfusion CT (PCT) in children with traumatic brain injury in prediciting their consecutive clinical outcome. Materials and methods: Twelve paediatric patients with acute traumatic brain injury underwent cerebral CT coupled with PCT during their admission at the emergency room (ER). PCT maps were reviewed for mean transit time (MTT), regional cerebral blood flow (rCBF) and regional cerebral blood volume (rCBV) abnormalities. PCT results were compared to short- and mid-term clinical outcome. Results: 3 patients with low Glasgow Coma Scale (GCS) (98) and bad clinical outcome showed an increased MTT and decreased rCBV and rCBF. 5 patients with low GCS and good clinical outcome showed an increased MTT without abnormalities of rCBV and rCBF. In patients with GCS 08 and good outcome, PCT maps were normal in 2 cases; transient PCT abnormalities were identified in one case with an embedded fracture of the skull and in one case with an epileptic seizure. Conclusion: Cerebral PCT can identify diffuse abnormalities of cerebral perfusion in children with traumatic brain injury showing a low initial GCS and a bad outcome. PCT can be a valuable tool to predict the severity of the prognosis of these patients as soon as they are evaluated by CT-scan during their admission at the ER.
Resumo:
BACKGROUND: People with neurological disease have a much higher risk of both faecal incontinence and constipation than the general population. There is often a fine line between the two conditions, with any management intended to ameliorate one risking precipitating the other. Bowel problems are observed to be the cause of much anxiety and may reduce quality of life in these people. Current bowel management is largely empirical with a limited research base. OBJECTIVES: To determine the effects of management strategies for faecal incontinence and constipation in people with neurological diseases affecting the central nervous system. SEARCH STRATEGY: We searched the Cochrane Incontinence Group Specialised Trials Register (searched 26 January 2005), the Cochrane Central Register of Controlled Trials (Issue 2, 2005), MEDLINE (January 1966 to May 2005), EMBASE (January 1998 to May 2005) and all reference lists of relevant articles. SELECTION CRITERIA: All randomised or quasi-randomised trials evaluating any types of conservative or surgical measure for the management of faecal incontinence and constipation in people with neurological diseases were selected. Specific therapies for the treatment of neurological diseases that indirectly affect bowel dysfunction were also considered. DATA COLLECTION AND ANALYSIS: Two reviewers assessed the methodological quality of eligible trials and two reviewers independently extracted data from included trials using a range of pre-specified outcome measures. MAIN RESULTS: Ten trials were identified by the search strategy, most were small and of poor quality. Oral medications for constipation were the subject of four trials. Cisapride does not seem to have clinically useful effects in people with spinal cord injuries (three trials). Psyllium was associated with increased stool frequency in people with Parkinson's disease but did not alter colonic transit time (one trial). Prucalopride, an enterokinetic did not demonstrate obvious benefits in this patient group (one study). Some rectal preparations to initiate defaecation produced faster results than others (one trial). Different time schedules for administration of rectal medication may produce different bowel responses (one trial). Mechanical evacuation may be more effective than oral or rectal medication (one trial). There appears to be a benefit to patients in one-off educational interventions from nurses. The clinical significance of any of these results is difficult to interpret. AUTHORS' CONCLUSIONS: There is still remarkably little research on this common and, to patients, very significant condition. It is not possible to draw any recommendation for bowel care in people with neurological diseases from the trials included in this review. Bowel management for these people must remain empirical until well-designed controlled trials with adequate numbers and clinically relevant outcome measures become available.
Resumo:
BACKGROUND: People with neurological disease have a much higher risk of both faecal incontinence and constipation than the general population. There is often a fine dividing line between the two conditions, with any management intended to ameliorate, one risking precipitating the other. Bowel problems are observed to be the cause of much anxiety and may reduce quality of life in these people. Current bowel management is largely empirical with a limited research base. OBJECTIVES: To determine the effects of management strategies for faecal incontinence and constipation in people with neurological diseases affecting the central nervous system. SEARCH STRATEGY: We searched the Cochrane Incontinence Group Trials Register, the Cochrane Controlled Trials Register, MEDLINE, EMBASE and all reference lists of relevant articles. Date of the most recent searches: May 2000. SELECTION CRITERIA: All randomised or quasi-randomised trials evaluating any types of conservative, or surgical measure for the management of faecal incontinence and constipation in people with neurological diseases were selected. Specific therapies for the treatment of neurological diseases that indirectly affect bowel dysfunction have also been considered. DATA COLLECTION AND ANALYSIS: All three reviewers assessed the methodological quality of eligible trials and two reviewers independently extracted data from included trials using a range of pre-specified outcome measures. MAIN RESULTS: Only seven trials were identified by the search strategy and all were small and of poor quality. Oral medications for constipation were the subject of four trials. Cisapride does not seem to have clinically useful effects in people with spinal cord injuries (two trials). Psyllium was associated with increased stool frequency in people with Parkinson's disease but not altered colonic transit time (one trial). Some rectal preparations to initiate defecation produced faster results than others (one trial). Different time schedules for administration of rectal medication may produce different bowel responses (one trial). Mechanical evacuation may be more effective than oral or rectal medication (one trial). The clinical significance of any of these results is difficult to interpret. REVIEWER'S CONCLUSIONS: It is not possible to draw any recommendation for bowel care in people with neurological diseases from the trials included in this review. Bowel management for these people must remain empirical until well-designed controlled trials with adequate numbers and clinically relevant outcome measures become available.
Resumo:
BACKGROUND AND PURPOSE: The posterior circulation Acute Stroke Prognosis Early CT Score (pc-APECTS) applied to CT angiography source images (CTA-SI) predicts the functional outcome of patients in the Basilar Artery International Cooperation Study (BASICS). We assessed the diagnostic and prognostic impact of pc-ASPECTS applied to perfusion CT (CTP) in the BASICS registry population. METHODS: We applied pc-ASPECTS to CTA-SI and cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT) parameter maps of BASICS patients with CTA and CTP studies performed. Hypoattenuation on CTA-SI, relative reduction in CBV or CBF, or relative increase in MTT were rated as abnormal. RESULTS: CTA and CTP were available in 27/592 BASICS patients (4.6%). The proportion of patients with any perfusion abnormality was highest for MTT (93%; 95% confidence interval [CI], 76%-99%), compared with 78% (58%-91%) for CTA-SI and CBF, and 46% (27%-67%) for CBV (P < .001). All 3 patients with a CBV pc-ASPECTS < 8 compared to 6/23 patients with a CBV pc-ASPECTS ≥ 8 had died at 1 month (RR 3.8; 95% CI, 1.9-7.6). CONCLUSION: CTP was performed in a minority of the BASICS registry population. Perfusion disturbances in the posterior circulation were most pronounced on MTT parameter maps. CBV pc-ASPECTS < 8 may indicate patients with high case fatality.
Resumo:
INTRODUCTION: Perfusion-CT (PCT) processing involves deconvolution, a mathematical operation that computes the perfusion parameters from the PCT time density curves and an arterial curve. Delay-sensitive deconvolution does not correct for arrival delay of contrast, whereas delay-insensitive deconvolution does. The goal of this study was to compare delay-sensitive and delay-insensitive deconvolution PCT in terms of delineation of the ischemic core and penumbra. METHODS: We retrospectively identified 100 patients with acute ischemic stroke who underwent admission PCT and CT angiography (CTA), a follow-up vascular study to determine recanalization status, and a follow-up noncontrast head CT (NCT) or MRI to calculate final infarct volume. PCT datasets were processed twice, once using delay-sensitive deconvolution and once using delay-insensitive deconvolution. Regions of interest (ROIs) were drawn, and cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT) in these ROIs were recorded and compared. Volume and geographic distribution of ischemic core and penumbra using both deconvolution methods were also recorded and compared. RESULTS: MTT and CBF values are affected by the deconvolution method used (p < 0.05), while CBV values remain unchanged. Optimal thresholds to delineate ischemic core and penumbra are different for delay-sensitive (145 % MTT, CBV 2 ml × 100 g(-1) × min(-1)) and delay-insensitive deconvolution (135 % MTT, CBV 2 ml × 100 g(-1) × min(-1) for delay-insensitive deconvolution). When applying these different thresholds, however, the predicted ischemic core (p = 0.366) and penumbra (p = 0.405) were similar with both methods. CONCLUSION: Both delay-sensitive and delay-insensitive deconvolution methods are appropriate for PCT processing in acute ischemic stroke patients. The predicted ischemic core and penumbra are similar with both methods when using different sets of thresholds, specific for each deconvolution method.
Resumo:
Electrical impedance tomography (EIT) allows the measurement of intra-thoracic impedance changes related to cardiovascular activity. As a safe and low-cost imaging modality, EIT is an appealing candidate for non-invasive and continuous haemodynamic monitoring. EIT has recently been shown to allow the assessment of aortic blood pressure via the estimation of the aortic pulse arrival time (PAT). However, finding the aortic signal within EIT image sequences is a challenging task: the signal has a small amplitude and is difficult to locate due to the small size of the aorta and the inherent low spatial resolution of EIT. In order to most reliably detect the aortic signal, our objective was to understand the effect of EIT measurement settings (electrode belt placement, reconstruction algorithm). This paper investigates the influence of three transversal belt placements and two commonly-used difference reconstruction algorithms (Gauss-Newton and GREIT) on the measurement of aortic signals in view of aortic blood pressure estimation via EIT. A magnetic resonance imaging based three-dimensional finite element model of the haemodynamic bio-impedance properties of the human thorax was created. Two simulation experiments were performed with the aim to (1) evaluate the timing error in aortic PAT estimation and (2) quantify the strength of the aortic signal in each pixel of the EIT image sequences. Both experiments reveal better performance for images reconstructed with Gauss-Newton (with a noise figure of 0.5 or above) and a belt placement at the height of the heart or higher. According to the noise-free scenarios simulated, the uncertainty in the analysis of the aortic EIT signal is expected to induce blood pressure errors of at least ± 1.4 mmHg.
Resumo:
The use of high-strength aluminium alloys as material for injection molding tools to produce small and medium batches of plastic products as well as prototyping molds is becoming of increasing demand by the tooling industry. These alloys are replacing the traditional use of steel in the cases above because they offer many advantages such as very high thermal conductivity associated with good corrosion and wear resistance presenting good machinability in milling and electrical discharge machining operations. Unfortunately there is little technological knowledge on the Electrical Discharge Machining (EDM) of high-strength aluminium alloys, especially about the AMP 8000 alloy. The duty factor, which means the ratio between pulse duration and pulse cycle time exerts an important role on the performance of EDM. This work has carried out an experimental study on the variation of the duty factor in order to analyze its influence on material removal rate and volumetric relative wear under roughing conditions of EDM process. The results showed that high values of duty factor are possible to be applied without bringing instability into the EDM process and with improvement of material removal rate and volumetric relative wear.
Resumo:
We present a theoretical investigation of shot-noise properties in nondegenerate elastic diffusive conductors. Both Monte Carlo simulations and analytical approaches are used. Two interesting phenomena are found: (i) the display of enhanced shot noise for given energy dependences of the scattering time, and (ii) the recovery of full shot noise for asymptotic high applied bias. The first phenomenon is associated with the onset of negative differential conductivity in energy space that drives the system towards a dynamical electrical instability in excellent agreement with analytical predictions. The enhancement is found to be strongly amplified when the dimensionality in momentum space is lowered from three to two dimensions. The second phenomenon is due to the suppression of the effects of long-range Coulomb correlations that takes place when the transit time becomes the shortest time scale in the system, and is common to both elastic and inelastic nondegenerate diffusive conductors. These phenomena shed different light in the understanding of the anomalous behavior of shot noise in mesoscopic conductors, which is a signature of correlations among different current pulses.
Resumo:
Prediction of the solar wind conditions in near-Earth space, arising from both quasi-steady and transient structures, is essential for space weather forecasting. To achieve forecast lead times of a day or more, such predictions must be made on the basis of remote solar observations. A number of empirical prediction schemes have been proposed to forecast the transit time and speed of coronal mass ejections (CMEs) at 1 AU. However, the current lack of magnetic field measurements in the corona severely limits our ability to forecast the 1 AU magnetic field strengths resulting from interplanetary CMEs (ICMEs). In this study we investigate the relation between the characteristic magnetic field strengths and speeds of both magnetic cloud and noncloud ICMEs at 1 AU. Correlation between field and speed is found to be significant only in the sheath region ahead of magnetic clouds, not within the clouds themselves. The lack of such a relation in the sheaths ahead of noncloud ICMEs is consistent with such ICMEs being skimming encounters of magnetic clouds, though other explanations are also put forward. Linear fits to the radial speed profiles of ejecta reveal that faster-traveling ICMEs are also expanding more at 1 AU. We combine these empirical relations to form a prediction scheme for the magnetic field strength in the sheaths ahead of magnetic clouds and also suggest a method for predicting the radial speed profile through an ICME on the basis of upstream measurements.
Resumo:
Four multiparous cows with cannulas in the rumen and proximal duodenum were used in early lactation in a 4 x 4 Latin square experiment to investigate the effect of method of application of a fibrolytic enzyme product on digestive processes and milk production. The cows were given ad libitum a total mixed ration (TMR) composed of 57% (dry matter basis) forage (3:1 corn silage:grass silage) and 43% concentrates. The TMR contained (g/kg dry matter): 274 neutral detergent fiber, 295 starch, 180 crude protein. Treatments were TMR alone or TMR with the enzyme product added (2 kg/1000 kg TMR dry matter) either sprayed on the TMR 1 h before the morning feed (TMR-E), sprayed only on the concentrate the day before feeding (Concs-E), or infused into the rumen for 14 h/d (Rumen-E). There Was no significant effect on either feed intake or milk yield but both were highest on TMR-E. Rumen digestibility of dry matter, organic matter, and starch was unaffected by the enzyme. Digestibility of NDF was lowest on TMR-E in the rumen but highest postruminally. Total Tract digestibility was highest on TMR-E for dry matter, organic matter, and starch but treatment differences were nonsignificant for neutral detergent fiber: Corn silage stover retention time in the rumen was reduced by all enzyme treatments but postruminal transit time vas increased so the decline in total tract retention. time with enzymes was not significant. It is suggested that the tendency for enzymes to reduce particle retention time in the rumen may, by reducing the time available for fibrolysis to occur, at least partly explain the variability in the reported responses to enzyme treatment.
Resumo:
Background The gut and immune system form a complex integrated structure that has evolved to provide effective digestion and defence against ingested toxins and pathogenic bacteria. However, great variation exists in what is considered normal healthy gut and immune function. Thus, whilst it is possible to measure many aspects of digestion and immunity, it is more difficult to interpret the benefits to individuals of variation within what is considered to be a normal range. Nevertheless, it is important to set standards for optimal function for use both by the consumer, industry and those concerned with the public health. The digestive tract is most frequently the object of functional and health claims and a large market already exists for gut-functional foods worldwide. Aim To define normal function of the gut and immune system and describe available methods of measuring it. Results We have defined normal bowel habit and transit time, identified their role as risk factors for disease and how they may be measured. Similarly, we have tried to define what is a healthy gut flora in terms of the dominant genera and their metabolism and listed the many, varied and novel methods for determining these parameters. It has proved less easy to provide boundaries for what constitutes optimal or improved gastric emptying, gut motility, nutrient and water absorption and the function of organs such as the liver, gallbladder and pancreas. The many tests of these functions are described. We have discussed gastrointestinal well being. Sensations arising from the gut can be both pleasant and unpleasant. However, the characteristics of well being are ill defined and merge imperceptibly from acceptable to unacceptable, a state that is subjective. Nevertheless, we feel this is an important area for future work and method development. The immune system is even more difficult to make quantitative judgements about. When it is defective, then clinical problems ensure, but this is an uncommon state. The innate and adaptive immune systems work synergistically together and comprise many cellular and humoral factors. The adaptive system is extremely sophisticated and between the two arms of immunity there is great redundancy, which provides robust defences. New aspects of immune function are discovered regularly. It is not clear whether immune function can be "improved". Measuring aspects of immune function is possible but there is no one test that will define either the status or functional capacity of the immune system. Human studies are often limited by the ability to sample only blood or secretions such as saliva but it should be remembered that only 2% of lymphocytes circulate at any given time, which limits interpretation of data. We recommend assessing the functional capacity of the immune system by: measuring specific cell functions ex vivo, measuring in vivo responses to challenge, e. g. change in antibody in blood or response to antigens, determining the incidence and severity of infection in target populations during naturally occurring episodes or in response to attenuated pathogens.
Resumo:
Assessment of the risk to human health posed by contaminated land may be seriously overestimated if reliant on total pollutant concentration. In vitro extraction tests, such as the physiologically based extraction test (PBET), imitate the physicochemical conditions of the human gastro-intestinal tract and offer a more practicable alternative for routine testing purposes. However, even though passage through the colon accounts for approximately 80% of the transit time through the human digestive tract and the typical contents of the colon in vivo are a carbohydrate-rich aqueous medium with the potential to promote desorption of organic pollutants, PBET comprises stomach and small intestine compartments only. Through addition of an eight-hour colon compartment to PBET and use of a carbohydrate-rich fed-state medium we demonstrated that colon-extended PBET (CE-PBET) in- creased assessments of soil-bound PAH bioaccessibility by up to 50% in laboratory soils and a factor of 4 in field soils. We attribute this increased bioaccessibility to a combination of the additional extraction time and the presence of carbohydrates in the colon compartment, both of which favor PAH desorption from soil. We propose that future assessments of the bioaccessibility of organic pollutants in soils using physiologically based extraction tests should have a colon compartment as in CE-PBET.
Resumo:
The adiabatic transit time of wave energy radiated by an Agulhas ring released in the South Atlantic Ocean to the North Atlantic Ocean is investigated in a two-layer ocean model. Of particular interest is the arrival time of baroclinic energy in the northern part of the Atlantic, because it is related to variations in the meridional overturning circulation. The influence of the Mid-Atlantic Ridge is also studied, because it allows for the conversion from barotropic to baroclinic wave energy and the generation of topographic waves. Barotropic energy from the ring is present in the northern part of the model basin within 10 days. From that time, the barotropic energy keeps rising to attain a maximum 500 days after initiation. This is independent of the presence or absence of a ridge in the model basin. Without a ridge in the model, the travel time of the baroclinic signal is 1300 days. This time is similar to the transit time of the ring from the eastern to the western coast of the model basin. In the presence of the ridge, the baroclinic signal arrives in the northern part of the model basin after approximately 10 days, which is the same time scale as that of the barotropic signal. It is apparent that the ridge can facilitate the energy conversion from barotropic to baroclinic waves and the slow baroclinic adjustment can be bypassed. The meridional overturning circulation, parameterized in two ways as either a purely barotropic or a purely baroclinic phenomenon, also responds after 1300 days. The ring temporarily increases the overturning strength. Th presence of the ridge does not alter the time scales.
Resumo:
Red meat consumption causes a dose-dependent increase in fecal apparent total N-nitroso compounds (ATNC). The genotoxic effects of these ATNCs were investigated using two different Comet assay protocols to determine the genotoxicity of fecal water samples. Fecal water samples were obtained from two studies of a total of 21 individuals fed diets containing different amounts of red meat, protein, heme, and iron. The first protocol incubated the samples with HT-29 cells for 5 min at 4 degrees C, whereas the second protocol used a longer exposure time of 30 min and a higher incubation temperature of 37 degrees C. DNA strand breaks were quantified by the tail moment (DNA in the comet tail multiplied by the comet tail length). The results of the two Comet assay protocols were significantly correlated (r = 0.35, P = 0.003), however, only the second protocol resulted in detectable levels of DNA damage. Inter-individual effects were variable and there was no effect on fecal water genotoxicity by diet (P > 0.20), mean transit time (P = 0.588), or weight (P = 0.705). However, there was a highly significant effect of age (P = 0.019). There was no significant correlation between concentrations of ATNCs in fecal homogenates and fecal water genotoxicity (r = 0.04, P = 0.74). ATNC levels were lower in fecal water samples (272 microg/kg) compared to that of fecal homogenate samples (895 microg/kg) (P < 0.0001). Failure to find dietary effects on fecal water genotoxicity may therefore be attributed to individual variability and low levels of ATNCs in fecal water samples.