977 resultados para Proximity detectors.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The potential for universities to contribute positively to business innovation has received much attention in recent years. While the determinants of university-business cooperation have been examined extensively, less attention has been given to the mediating influence of proximity in this relationship. The analysis in this paper builds on theUKbusiness innovation survey (2002–2005) by incorporating measures of the university research environment for each of the 16,500 businesses surveyed. These measures allow us to look beyond business-level characteristics as determinants of the geography of university cooperation and account for the character of the local university environment. Measures include the distance from each business to its nearest university, the quality of local university research and the density of the university research environment. The findings suggest that significant differences exist between those businesses that cooperate with local universities and those that cooperate with non-local universities. These differences relate to business size, sales profile, location, absorptive capacity and innovation activity. In addition, we also find that if a business is located close to a research excellent university, cooperation tends to remain local, however, the distance between businesses and the nearest university is not a significant determinant of university-business cooperation and further, the higher the concentration of universities in the business locale, the more likely businesses are to cooperate with non-local universities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background
It is not clear whether the availability of tobacco affects the likelihood of smoking cessation. We examined whether the proximity to a tobacco store and
the number of stores were associated with smoking cessation, and compared results for proximity variables based on walking and straight-line (as the crow flies) distance.

Methods
The study population consisted of 8751 baseline smokers from the Finnish Public Sector study in 1997–2005. Smoking intensity (cigarettes/day) was
determined at baseline and smoking cessation was determined from a follow-up survey in 2008–2009. Proximity was measured using straight-line and walking
distance from home to the nearest tobacco store, and another exposure variable was the number of stores within 0.50 km from home. We calculated associations
with log-binomial regression models, adjusting for individual-level and area-level confounders.

Results
Of the participants, 3482 (39.8%) quit smoking during the follow-up (mean follow-up 5.5 years, SD 2.3 years). Among men who were moderate/heavy smokers at baseline and lived <0.50 km walking distance from the nearest tobacco store, the likelihood of smoking cessation was 27% (95% CI 12% to 40%) lower compared with those living ≥0.50 km from a store. Having even one store within 0.50 km walking distance from home decreased cessation in men who were moderate/heavy smokers by 37% (95% CI 19% to 51%). No decrease was found for men who were light smokers at baseline or for women.

Conclusions
Living within walking distance of a tobacco store reduced the likelihood of smoking cessation among men who were moderate/heavy smokers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel method for characterising the full spectrum of deuteron ions emitted by laser driven multi-species ion sources is discussed. The procedure is based on using differential filtering over the detector of a Thompson parabola ion spectrometer, which enables discrimination of deuterium ions from heavier ion species with the same charge-to-mass ratio (such as C6 +, O8 +, etc.). Commonly used Fuji Image plates were used as detectors in the spectrometer, whose absolute response to deuterium ions over a wide range of energies was calibrated by using slotted CR-39 nuclear track detectors. A typical deuterium ion spectrum diagnosed in a recent experimental campaign is presented, which was produced from a thin deuterated plastic foil target irradiated by a high power laser.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Shoeprint evidence collected from crime scenes can play an important role in forensic investigations. Usually, the analysis of shoeprints is carried out manually and is based on human expertise and knowledge. As well as being error prone, such a manual process can also be time consuming; thus affecting the usability and suitability of shoeprint evidence in a court of law. Thus, an automatic system for classification and retrieval of shoeprints has the potential to be a valuable tool. This paper presents a solution for the automatic retrieval of shoeprints which is considerably more robust than existing solutions in the presence of geometric distortions such as scale, rotation and scale distortions. It addresses the issue of classifying partial shoeprints in the presence of rotation, scale and noise distortions and relies on the use of two local point-of-interest detectors whose matching scores are combined. In this work, multiscale Harris and Hessian detectors are used to select corners and blob-like structures in a scale-space representation for scale invariance, while Scale Invariant Feature Transform (SIFT) descriptor is employed to achieve rotation invariance. The proposed technique is based on combining the matching scores of the two detectors at the score level. Our evaluation has shown that it outperforms both detectors in most of our extended experiments when retrieving partial shoeprints with geometric distortions, and is clearly better than similar work published in the literature. We also demonstrate improved performance in the face of wear and tear. As matter of fact, whilst the proposed work outperforms similar algorithms in the literature, it is shown that achieving good retrieval performance is not constrained by acquiring a full print from a scene of crime as a partial print can still be used to attain comparable retrieval results to those of using the full print. This gives crime investigators more flexibility is choosing the parts of a print to search for in a database of footwear.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using the Otto geometry of attenuated total reflection (prism-air gap-sample), front illuminated PtSi/Si Schottky barrier detectors are shown to exhibit enhanced photocurrent at surface plasmon resonance in the near infrared region. Correlation of the measured photocurrent with the calculated transmittance of light into the Si substate is demonstrated. The transmittance, which is due to surface plasmon re-radiation, is the optical parameter of principal importance in photosignal generation since the photon energies used here are greater than the silicon intrinsic bandgap. The results presented here indicate clearly the important features in optimizing surface plasmon enhancement in photodetection both above and below the silicon absorption edge.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Calibration of three scintillators (EJ232Q, BC422Q, and EJ410) in a time-of-flight arrangement using a laser drive-neutron source is presented. The three plastic scintillator detectors were calibrated with gamma insensitive bubble detector spectrometers, which were absolutely calibrated over a wide range of neutron energies ranging from sub-MeV to 20 MeV. A typical set of data obtained simultaneously by the detectors is shown, measuring the neutron spectrum emitted from a petawatt laser irradiated thin foil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mutual variation of the received signal which occurs as a consequence of the channel reciprocity property has recently been proposed as a viable method for secret key generation. However, this cannot be strictly maintained in practice as the property is applicable only in the absence of interference. To ensure the propagation defined key remains secret, one requirement is that there remain high degrees of uncertainty between the legitimate users channel response and that of any eavesdropper's. In this paper, we investigate whether such de-correlation occurs for an indoor point-to-point link at 2.45 GHz. This is achieved by computing the localized correlation coefficient between the simultaneous channel response measured by the legitimate users and that of multiple distributed eavesdroppers for static and dynamic scenarios.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Micro-Hole & Strip Plate (MHSP) é uma microestrutura desenvolvida recentemente em instituições universitárias portuguesas. Neste trabalho, o seu desempenho como detector para imagiologia é explorado, tendo como objectivo a imagiologia não só de neutrões, mas também de raios X. A aplicação do método da divisão resistiva de carga é aplicada a uma MHSP especialmente desenhada para sensibilidade em posição. Várias abordagens em termos da electrónica de aquisição de sinal são testadas, sem perder de vista a relação desempenho-preço. Resoluções espaciais abaixo de 1 mm foram obtidas com a MHSP a operar em xénon e tetrafluorometano, com um sistema de detecção a um preço modesto quando comparado com as alternativas, e apropriado para inúmeras aplicações em imagiologia de neutrões e de raios X.