857 resultados para Provisional Measure (MP)
Resumo:
Landscape is an example of a non-market good where no metrics exist to measure its quality. The paper proposes an original methodology to nevertheless estimate scope variables in those circumstances, allowing then to better test if people's willingnesstopay for such good is sensitive to the scope. The methodology is based on techniques developed in the context of multicriteria decision analysis. It is applied to assess the quality of the landscape of several Swiss alpine resorts. This assessment is then used as an explanatory variable in a hedonic price function to explain the rent of apartments and to derive an implicit price of the landscape quality.
Resumo:
BACKGROUND The high prevalence of women that do not reach the recommended level of physical activity is worrisome. A sedentary lifestyle has negative consequences on health status and increases health care costs. The main objective of this project is to assess the cost-effectiveness of a primary care-based exercise intervention in perimenopausal women. METHODS/DESIGN The present study is a Randomized Controlled Trial. A total of 150 eligible women will be recruited and randomly assigned to either a 16-week exercise intervention (3 sessions/week), or to usual care (control) group. The primary outcome measure is the incremental cost-effectiveness ratio. The secondary outcome measures are: i) socio-demographic and clinical information; ii) body composition; iii) dietary patterns; iv) glycaemic and lipid profile; v) physical fitness; vi) physical activity and sedentary behaviour; vii) sleep quality; viii) quality of life, mental health and positive health; ix) menopause symptoms. All outcomes will be assessed at baseline and post intervention. The data will be analysed on an intention-to-treat basis and per protocol. In addition, we will conduct a cost effectiveness analysis from a health system perspective. DISCUSSION The intervention designed is feasible and if it proves to be clinically and cost effective, it can be easily transferred to other similar contexts. Consequently, the findings of this project might help the Health Systems to identify strategies for primary prevention and health promotion as well as to reduce health care requirements and costs. TRIAL REGISTRATION ClinicalTrials.gov Identifier: NCT02358109 . Date of registration: 05/02/2015.
Resumo:
Obesity and binge eating disorder are common in individuals with psychotic disorders. Eating and weight-related cognitions are known to influence eating behaviors. The study was designed to assess the psychometric properties of the Mizes Anorectic Cognitions Questionnaire (MAC-R) in patients with psychotic disorders. Binge eating disorder (BED), body mass index (BMI), the MAC-R and the three factor eating questionnaire (TFEQ) were assessed in 125 patients with a diagnosis of schizophrenia or schizoaffective disorder. Whereas the MAC-R has not acceptable psychometric properties, a brief version of the MAC-R (BMAC) has good psychometrical properties and is correlated with TFEQ and BMI. Binge eating disorder is also correlated to the Rigid Weight Regulation and Fear of Weight Gain subscale. The BMAC is a useful brief measure to assess eating and weight related cognitions in people with psychotic disorders.
Resumo:
Study design:Cross-sectional validation study.Objectives:To develop and validate a self-report version of the Spinal Cord Independence Measure (SCIM III).Setting:Two SCI rehabilitation facilities in Switzerland.Methods:SCIM III comprises 19 questions on daily tasks with a total score between 0 and 100 and subscales for 'self-care', 'respiration & sphincter management' and 'mobility'. A self-report version (SCIM-SR) was developed by expert discussions and pretests in individuals with spinal cord injury (SCI) using a German translation. A convenience sample of 99 inpatients with SCI was recruited. SCIM-SR data were analyzed together with SCIM III data obtained from attending health professionals.Results:High correlations between SCIM III and SCIM-SR were observed. Pearson's r for the total score was 0.87 (95% confidence interval (CI) 0.82-0.91), for the subscales self-care 0.87 (0.81-0.91); respiration & sphincter management 0.81 (0.73-0.87); and mobility 0.87 (0.82-0.91). Intraclass correlations were: total score 0.90 (95% CI 0.85-0.93); self-care 0.86 (0.79-0.90); respiration & sphincter management 0.80 (0.71-0.86); and mobility 0.83 (0.76-0.89). Bland-Altman plots showed that patients rated their functioning higher than professionals, in particular for mobility. The mean difference between SCIM-SR and SCIM III for the total score was 5.14 (point estimate 95% CI 2.95-7.34), self-care 0.89 (0.19-1.59), respiration & sphincter management 1.05 (0.18-2.28 ) and mobility 3.49 (2.44-4.54). Particularly patients readmitted because of pressure sores rated their independence higher than attending professionals.Conclusion:Our results support the criterion validity of SCIM-SR. The self-report version may facilitate long-term evaluations of independence in persons with SCI in their home situation.
Resumo:
BACKGROUND: The yeast Schizosaccharomyces pombe is frequently used as a model for studying the cell cycle. The cells are rod-shaped and divide by medial fission. The process of cell division, or cytokinesis, is controlled by a network of signaling proteins called the Septation Initiation Network (SIN); SIN proteins associate with the SPBs during nuclear division (mitosis). Some SIN proteins associate with both SPBs early in mitosis, and then display strongly asymmetric signal intensity at the SPBs in late mitosis, just before cytokinesis. This asymmetry is thought to be important for correct regulation of SIN signaling, and coordination of cytokinesis and mitosis. In order to study the dynamics of organelles or large protein complexes such as the spindle pole body (SPB), which have been labeled with a fluorescent protein tag in living cells, a number of the image analysis problems must be solved; the cell outline must be detected automatically, and the position and signal intensity associated with the structures of interest within the cell must be determined. RESULTS: We present a new 2D and 3D image analysis system that permits versatile and robust analysis of motile, fluorescently labeled structures in rod-shaped cells. We have designed an image analysis system that we have implemented as a user-friendly software package allowing the fast and robust image-analysis of large numbers of rod-shaped cells. We have developed new robust algorithms, which we combined with existing methodologies to facilitate fast and accurate analysis. Our software permits the detection and segmentation of rod-shaped cells in either static or dynamic (i.e. time lapse) multi-channel images. It enables tracking of two structures (for example SPBs) in two different image channels. For 2D or 3D static images, the locations of the structures are identified, and then intensity values are extracted together with several quantitative parameters, such as length, width, cell orientation, background fluorescence and the distance between the structures of interest. Furthermore, two kinds of kymographs of the tracked structures can be established, one representing the migration with respect to their relative position, the other representing their individual trajectories inside the cell. This software package, called "RodCellJ", allowed us to analyze a large number of S. pombe cells to understand the rules that govern SIN protein asymmetry. CONCLUSIONS: "RodCell" is freely available to the community as a package of several ImageJ plugins to simultaneously analyze the behavior of a large number of rod-shaped cells in an extensive manner. The integration of different image-processing techniques in a single package, as well as the development of novel algorithms does not only allow to speed up the analysis with respect to the usage of existing tools, but also accounts for higher accuracy. Its utility was demonstrated on both 2D and 3D static and dynamic images to study the septation initiation network of the yeast Schizosaccharomyces pombe. More generally, it can be used in any kind of biological context where fluorescent-protein labeled structures need to be analyzed in rod-shaped cells. AVAILABILITY: RodCellJ is freely available under http://bigwww.epfl.ch/algorithms.html, (after acceptance of the publication).
Resumo:
The interfacial micromotion is closely associated to the long-term success of cementless hip prostheses. Various techniques have been proposed to measure them, but only a few number of points over the stem surface can be measured simultaneously. In this paper, we propose a new technique based on micro-Computer Tomography (μCT) to measure locally the relative interfacial micromotions between the metallic stem and the surrounding femoral bone. Tantalum beads were stuck at the stem surface and spread at the endosteal surface. Relative micromotions between the stem and the endosteal bone surfaces were measured at different loading amplitudes. The estimated error was 10μm and the maximal micromotion was 60μm, in the loading direction, at 1400N. This pilot study provided a local measurement of the micromotions in the 3 direction and at 8 locations on the stem surface simultaneously. This technique could be easily extended to higher loads and a much larger number of points, covering the entire stem surface and providing a quasi-continuous distribution of the 3D interfacial micromotions around the stem. The new measurement method would be very useful to compare the induced micromotions of different stem designs and to optimize the primary stability of cementless total hip arthroplasty.
Resumo:
OBJECTIVE: A new tool to quantify visceral adipose tissue (VAT) over the android region of a total body dual-energy x-ray absorptiometry (DXA) scan has recently been reported. The measurement, CoreScan, is currently available on Lunar iDXA densitometers. The purpose of the study was to determine the precision of the CoreScan VAT measurement, which is critical for understanding the utility of this measure in longitudinal trials. DESIGN AND METHODS: VAT precision was characterized in both an anthropomorphic imaging phantom (measured on 10 Lunar iDXA systems) and a clinical population consisting of obese women (n = 32). RESULTS: The intrascanner precision for the VAT phantom across 9 quantities of VAT mass (0-1,800 g) ranged from 28.4 to 38.0 g. The interscanner precision ranged from 24.7 to 38.4 g. There was no statistical dependence on the quantity of VAT for either the inter- or intrascanner precision result (p = 0.670). Combining inter- and intrascanner precision yielded a total phantom precision estimate of 47.6 g for VAT mass, which corresponds to a 4.8% coefficient of variance (CV) for a 1 kg VAT mass. Our clinical population, who completed replicate total body scans with repositioning between scans, showed a precision of 56.8 g on an average VAT mass of 1110.4 g. This corresponds to a 5.1% CV. Hence, the in vivo precision result was similar to the phantom precision result. CONCLUSIONS: The study suggests that CoreScan has a relatively low precision error in both phantoms and obese women and therefore may be a useful addition to clinical trials where interventions are targeted towards changes in visceral adiposity.
Resumo:
AbstractOBJECTIVEOf this study were to evaluate the functional independence of patients with intermittent claudication and to verify its association with sociodemographic and clinical variables, walking ability and physical activity level.METHODThis was a descriptive, exploratory, cross-sectional study with a quantitative approach. Fifty participants (66.4 years; 68% male) were recruited from Claudication Unit of a tertiary hospital. Functional Independence Measure were used to evaluate functional incapacity; the Baltimore Activity Scale, to estimate the physical activity level and the Walking Impairement Questionnaire, the walking ability.RESULTSParticipants had complete functional independence (124.8 + 2.0), low levels of physical activity (4.2 + 2.0), and impairment of walking ability; the worst performance was found in walking velocity domain (21.2 + 16.4). The functional independence score was associated with physical activity (r=0,402) and walking ability scores (distance, r=0,485; speed, r=0,463; stairs, r=0,337).CONCLUSIONIn conclusion, the level of functionality is associated with functional capacity in these patients.
The international development of the RGHQoL: a quality of life measure for recurrent genital herpes.
Resumo:
This paper describes the international development and psychometric testing of the Recurrent Genital Herpes Quality of Life Questionnaire (RGHQoL), a condition-specific quality of life (QoL) instrument. The theoretical foundation for the measure is the needs-based model of QoL and the content of the instrument was derived from in-depth qualitative interviews with relevant patients in the UK. Versions of the RGHQoL were required for the UK, USA, Italy, Germany, France and Denmark for use in international clinical trials. The results indicate that the final 20 item measure has good reliability, internal consistency and validity for all language versions. A small responsiveness study in Denmark suggested that the measure is sensitive to changes in QoL associated with the initiation of suppression treatment for recurrent genital herpes (RGH). It is concluded that the RGHQoL is a valuable instrument for inclusion in clinical trials. The psychometric properties of the instrument are such that it may also be used to monitor the progress of individual patients.
Resumo:
There is evidence showing that individual behavior often deviates fromthe classical principle of maximization. This evidence raises at least two importantquestions: (i) how severe the deviations are and (ii) which method is the best forextracting relevant information from choice behavior for the purposes of welfare analysis.In this paper we address these two questions by identifying from a foundationalanalysis a new measure of the rationality of individuals that enables the analysis ofindividual welfare in potentially inconsistent subjects, all based on standard revealedpreference data. We call such measure minimal index.