1000 resultados para Propellant actuated devices


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract is not available.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Online dynamic load modeling has become possible with the availability of Static Voltage Compensator (SVC) and Phasor Measurement Unit (PMU) devices. The power of the load response to the small random bounded voltage fluctuations caused from SVC can be measured by PMU for modelling purposes. The aim of this paper is to illustrate the capability of identifying an aggregated load model from high voltage substation level in the online environment. The induction motor is used as the main test subject since it contributes the majority of the dynamic loads. A test system representing simple electromechanical generator model serving dynamic loads through the transmission network is used to verify the proposed method. Also, dynamic load with multiple induction motors are modeled to achieve a better realistic load representation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An electric field (100 V/cm at 230°C and 150°C) has been applied to ammonium perchlorate (AP)/polystyrene (PS) propellant mixtures in order to understand the low temperature decomposition behavior of the propellant. The charge-carrying species is anionic in nature at 230°C, which could be ClO4−, but is cationic at 150°C, which could be either NH4+ or H+. These results are parallel to that observed for pure ammonium perchlorate (AP) pellets [1]. The burning rate (r' ) of the propellant was found to follow the same trend as that for the thermal decomposition of the propellant on application of an electric field. At 150°C Image was higher at the −ve electrode than at the +ve electrode, but at 230°C just the opposite was observed. Kinetic studies have confirmed that the decomposition of the orthorhombic AP follows two mechanism corresponding to E = 30 kcal mol−1 (180–230°C) and E = 15 kcal mol−1 (150–180°C).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis utilises an evidence-based approach to critically evaluate and summarize effectiveness research on physiotherapy, physiotherapy-related motor-based interventions and orthotic devices in children and adolescents with cerebral palsy (CP). It aims to assess the methodological challenges of the systematic reviews and trials, to evaluate the effectiveness of interventions in current use, and to make suggestions for future trials Methods: Systematic reviews were searched from computerized bibliographic databases up to August 2007 for physiotherapy and physiotherapy-related interventions, and up to May 2003 for orthotic devices. Two reviewers independently identified, selected, and assessed the quality of the reviews using the Overview Quality Assessment Questionnaire complemented with decision rules. From a sample of 14 randomized controlled trials (RCT) published between January 1990 and June 2003 we analysed the methods of sampling, recruitment, and comparability of groups; defined the components of a complex intervention; identified outcome measures based on the International Classification of Functioning, Disability and Health (ICF); analysed the clinical interpretation of score changes; and analysed trial reporting using a modified 33-item CONSORT (Consolidated Standards of Reporting Trials) checklist. The effectiveness of physiotherapy and physiotherapy-related interventions in children with diagnosed CP was evaluated in a systematic review of randomised controlled trials that were searched from computerized databases from January 1990 up to February 2007. Two reviewers independently assessed the methodological quality, extracted the data, classified the outcomes using the ICF, and considered the level of evidence according to van Tulder et al. (2003). Results: We identified 21 reviews on physiotherapy and physiotherapy-related interventions and five on orthotic devices. These reviews summarized 23 or 5 randomised controlled trials and 104 or 27 observational studies, respectively. Only six reviews were of high quality. These found some evidence supporting strength training, constraint-induced movement therapy or hippotherapy, and insufficient evidence on comprehensive interventions. Based on the original studies included in the reviews on orthotic devices we found some short-term effects of lower limb casting on passive range of movement, and of ankle-foot orthoses on equinus walk. Long term effects of lower limb orthoses have not been studied. Evidence of upper limb casting or orthoses is conflicting. In the sample of 14 RCTs, most trials used simple randomisation, complemented with matching or stratification, but only three specified the concealed allocation. Numerous studies provided sufficient details on the components of a complex intervention, but the overlap of outcome measures across studies was poor and the clinical interpretation of observed score changes was mostly missing. Almost half (48%) of the applicable CONSORT-based items (range 28 32) were reported adequately. Most reporting inadequacies were in outcome measures, sample size determination, details of the sequence generation, allocation concealment and implementation of the randomization, success of assessor blinding, recruitment and follow-up dates, intention-to-treat analysis, precision of the effect size, co-interventions, and adverse events. The systematic review identified 22 trials on eight intervention categories. Four trials were of high quality. Moderate evidence of effectiveness was established for upper extremity treatments on attained goals, active supination and developmental status, and of constraint-induced therapy on the amount and quality of hand use and new emerging behaviours. Moderate evidence of ineffectiveness was found for strength training's effect on walking speed and stride length. Conflicting evidence was found for strength training's effect on gross motor function. For the other intervention categories the evidence was limited due to the low methodological quality and the statistically insignificant results of the studies. Conclusions: The high-quality reviews provide both supportive and insufficient evidence on some physiotherapy interventions. The poor quality of most reviews calls for caution, although most reviews drew no conclusions on effectiveness due to the poor quality of the primary studies. A considerable number of RCTs of good to fair methodological and reporting quality indicate that informative and well-reported RCTs on complex interventions in children and adolescents with CP are feasible. Nevertheless, methodological improvement is needed in certain areas of the trial design and performance, and the trial authors are encouraged to follow the CONSORT criteria. Based on RCTs we established moderate evidence for some effectiveness of upper extremity training. Due to limitations in methodological quality and variations in population, interventions and outcomes, mostly limited evidence on the effectiveness of most physiotherapy interventions is available to guide clinical practice. Well-designed trials are needed, especially for focused physiotherapy interventions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Porous carbon oxygen-reducing electrodes incorporated with perovskite oxide catalysts are reported. It has been possible to fabricate high-performance oxygen-reducing electrodes by introducing La0.5Sr0.5CoO3 and La0.99Sr0.01NiO3 with the activated coconut-shell charcoal; these electrodes could sustain load currents as high as 1 A cm−2 without serious degradation. A model to explain oxygen-reducing activity of these oxides has been proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Formation of benzaldehyde and benzoic acid have been observed during the slow decomposition of polystyrene/ammonium perchlorale propellant. This has been attributed to the formation of polystyrene peroxide intermediate which on decomposition gives the above producis. The chemical scheme for the formation of polystyrene peroxide has been presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Synthetic, natural, or composite, biomaterials occupy a key position in the management of disease and support continuous advancement of health care. Clinical utility of many permanent and biodegradable implants can be significantly improved via surface modification. Here, we discuss a novel polymer material developed from essential oil-based monoterpene alcohol using plasma polymerisation. The developed coatings are cytocompatible and limit adhesion and proliferation of a variety of pathogens. The coating can also be used to control degradation behaviour of resorbable materials, such as magnesium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ageing population and a multitude of neurological and cardiovascular illnesses that cannot be mitigated by medication alone have resulted in a significant growth in the number of patients that require implantable electronic devices. These range from sensors, gastric and cardiac pacemakers, cardioverter defibrillators, to deep brain, nerve, and bone stimulators. Long-term implants present specific engineering challenges, including low energy consumption and stable performance. Resorbable electronics may offer excellent short-term performance without the need for surgical removal. However, most electronic materials have poor bio- and cytocompatibility, resulting in immune reactions and infections. This paper reviews the current situation and highlights challenges for future advancements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This report provides quantitative information on the effects of turtle excluder devices (TEDs) and bycatch reduction devices (BRDs) on the catch rates of bycatch, prawns, scallops and byproduct species, such as Moreton Bay bugs and Balmain bugs, in Queensland’s major trawl fishing sectors. It also provides biological information on, and management advice for several species referred to in the Fishery Management Plan as the permitted species. Several recommendations are included for reducing bycatch in the trawl fishery and for sustaining stocks of the permitted species.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to investigate the effects on follicle stimulating hormone (FSH) secretion and dominant follicle (OF) growth, of treatment of Bos indicus heifers with different combinations of intra-vaginal progesterone releasing devices (IPRD), oestradiol benzoate (ODB), PGF(2 alpha), and eCG. Two-year-old Brahman (BN; n=30) and Brahman-cross (BNX; n=34) heifers were randomly allocated to three IPRD-treatments: (i) standard-dose IPRD [CM 1.56 g; 1.56 g progesterone (P-4); n = 17]; (ii) half-dose IPRD (CM 0.78 g; 0.78 g p(4); n=15); (iii) half-dose IPRD + 300 IU eCG at IPRD removal (CM 0.78 g+G; n=14); and, (iv) non-IPRD control (2 x PGF(2 alpha); n=18) 500 mu g cloprostenol on Days -16 and -2. IPRD-treated heifers received 250 mu g PGF(2 alpha) at IPRD insertion (Day 10) and IPRD removal (Day -2) and 1 mg ODB on Day -10 and Day -1. Follicular dynamics were monitored daily by trans-rectal ultrasonography from Day -10 to Day 1. Blood samples for determination of P-4 were collected daily and samples for FSH determination were collected at 12 h intervals from Day -9 to Day -2. A significant surge in concentrations of FSH was observed in the 2 x PGF(2 alpha), treatment 12 h prior and 48 h after follicular wave emergence, but not in the IPRD-treated heifers. Estimated mean concentrations of total plasma P-4 during the 8 days of IPRD insertion was greater (P<0.001) in the CM 1.56 g P-4 treated heifers compared to the CM 0.78 g P-4 treated heifers (18.38 ng/ml compared with 11.09 ng/ml, respectively). A treatment by genotype interaction (P=0.036) was observed in the mean plasma P4 concentration in heifers with no CL during IPRD insertion, whereby BN heifers in the CM 1.56 g treatment had greater plasma P-4 than the BNX heifers on Days-9, -7, -6, -5, and -4. However, there was no genotype effect in the CM 0.78 g +/- G or the 2 x PGF(2 alpha) treatment. Treatment had no effect on the DF growth from either day of wave emergence (P=0.378) or day of IPRD removal (P=0.780) to ovulation. This study demonstrates that FSH secretion in B. indicus heifers treated with a combination of IPRD's and ODB to synchronise ovulation was suppressed during the period of IPRD insertion but no significant effect on growth of the DF was observed. (C) 2013 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Successful healing of long bone fractures is dependent on the mechanical environment created within the fracture, which in turn is dependent on the fixation strategy. Recent literature reports have suggested that locked plating devices are too stiff to reliably promote healing. However, in vitro testing of these devices has been inconsistent in both method of constraint and reported outcomes, making comparisons between studies and the assessment of construct stiffness problematic. Each of the methods previously used in the literature were assessed for their effect on the bending of the sample and concordant stiffness. The choice of outcome measures used in in vitro fracture studies was also assessed. Mechanical testing was conducted on seven hole locked plated constructs in each method for comparison. Based on the assessment of each method the use of spherical bearings, ball joints or similar is suggested at both ends of the sample. The use of near and far cortex movement was found to be more comprehensive and more accurate than traditional centrally calculated inter fragmentary movement values; stiffness was found to be highly susceptible to the accuracy of deformation measurements and constraint method, and should only be used as a within study comparison method. The reported stiffness values of locked plate constructs from in vitro mechanical testing is highly susceptible to testing constraints and output measures, with many standard techniques overestimating the stiffness of the construct. This raises the need for further investigation into the actual mechanical behaviour within the fracture gap of these devices.