906 resultados para Programmable devices
Resumo:
This study aims to help broaden the use of electronic portal imaging devices (EPIDs) for pre-treatment patient positioning verification, from photon-beam radiotherapy to photon- and electron-beam radiotherapy, by proposing and testing a method for acquiring clinicallyuseful EPID images of patient anatomy using electron beams, with a view to enabling and encouraging further research in this area. EPID images used in this study were acquired using all available beams from a linac configured to deliver electron beams with nominal energies of 6, 9, 12, 16 and 20 MeV, as well as photon beams with nominal energies of 6 and 10 MV. A widely-available heterogeneous, approximately-humanoid, thorax phantom was used, to provide an indication of the contrast and noise produced when imaging different types of tissue with comparatively realistic thicknesses. The acquired images were automatically calibrated, corrected for the effects of variations in the sensitivity of individual photodiodes, using a flood field image. For electron beam imaging, flood field EPID calibration images were acquired with and without the placement of blocks of water-equivalent plastic (with thicknesses approximately equal to the practical range of electrons in the plastic) placed upstream of the EPID, to filter out the primary electron beam, leaving only the bremsstrahlung photon signal. While the electron beam images acquired using a standard (unfiltered) flood field calibration were observed to be noisy and difficult to interpret, the electron beam images acquired using the filtered flood field calibration showed tissues and bony anatomy with levels of contrast and noise that were similar to the contrast and noise levels seen in the clinically acceptable photon beam EPID images. The best electron beam imaging results (highest contrast, signal-to-noise and contrast-to-noise ratios) were achieved when the images were acquired using the higher energy electron beams (16 and 20 MeV) when the EPID was calibrated using an intermediate (12 MeV) electron beam energy. These results demonstrate the feasibility of acquiring clinically-useful EPID images of patient anatomy using electron beams and suggest important avenues for future investigation, thus enabling and encouraging further research in this area. There is manifest potential for the EPID imaging method proposed in this work to lead to the clinical use of electron beam imaging for geometric verification of electron treatments in the future.
Resumo:
This study presents results from an experimental 10-day research charter that was designed to quantify the effects of a) a turtle excluder device (TED) and b) a radial escape section bycatch reduction device (BRD) and c) both devices together, on prawn and bycatch catch rates in the Queensland shallow water eastern king prawn (Penaeus plebejus) trawl fishery. The bycatch was comprised of 250 taxa, mainly gurnards, whiting, lizard fish, flathead, dragonets, portunid crabs, turretfish and flounders. The observed mean catch rates of bycatch and marketable eastern king prawns from the standard trawl net (i.e., net with no TED or BRD) used during the charter were 11.06 (se 0.90) kg per hectare swept by the trawl gear (ha-1) and 0.94 kg ha-1, respectively. For the range of depths sampled (20.1-90.7 m), bycatch catch rates declined significantly at a rate of 0.14 kg ha-1 for every 1 m increase in depth, while prawn catch rates were unaffected. When both the TED and radial escape section BRD were used together they resulted in a 24% reduction in total bycatch catch rate compared to a standard net, but at a 20% reduction in marketable prawn catch rate. The largest reductions were achieved for stout whiting Sillago robusta (57% reduction) and yellowtail scad Trachurus novaezelandiae (32% reduction). Multidimensional scaling and analysis of similarities revealed that bycatch assemblages differed significantly between depths and latitude, but not between the different combinations of bycatch reduction devices. Despite the lowered prawn catch rates, the reduced bycatch catch rates are promising, particularly for S. robusta which is not permitted to be retained by the prawn trawl fleet and yet experiences considerable incidental fishing mortality, and because it is targeted in a separate licensed commercial fishery.
Resumo:
Sampling devices differing greatly in shape, size and operating condition have been used to collect air samples to determine rates of emission of volatile substances, including odour. However, physical chemistry principles, in particular the partitioning of volatile substances between two phases as explained by Henrys Law and the relationship between wind velocity and emission rate, suggests that different devices cannot be expected to provide equivalent emission rate estimates. Thus several problems are associated with the use of static and dynamic emission chambers, but the more turbulent devices such as wind tunnels do not appear to be subject to these problems. In general, the ability to relate emission rate estimates obtained from wind tunnel measurements to those derived from device-independent techniques supports the use of wind tunnels to determine emission rates that can be used as input data for dispersion models.
Resumo:
Two commonly used sampling devices (a wind tunnel and the US EPA dynamic emission chamber), were used to collect paired samples of odorous air from a number of agricultural odour sources. The odour samples were assessed using triangular, forced-choice dynamic olfactometry. The odour concentration data was combined with the flushing rate data to calculate odour emission rates for both devices on all sources. Odour concentrations were consistently higher in samples collected with a flux chamber (ratio ranging from 10:7 to 5:1, relative to wind tunnel samples), whereas odour emission rates were consistently larger when derived from wind tunnels (ratio ranging from 60:1 to 240:1, relative to flux chamber values). A complex relationship existed between emission rate estimates derived from each device, apparently influenced by the nature of the emitting surface. These results have great significance for users of odour dispersion models, for which an odour emission rate is a key input parameter.
Resumo:
We present a low-frequency electrical noise measurement in graphene based field effect transistors. For single layer graphene (SLG), the resistance fluctuations is governed by the screening of the charge impurities by the mobile charges. However, in case of Bilayer graphene (BLG), the electrical noise is strongly connected to its band structure, and unlike single layer graphene, displays a minimum when the gap between the conduction and valence band is zero. Using double gated BLG devices we have tuned the zero gap and charge neutrality points independently, which offers a versatile mechanism to investigate the low-energy band structure, charge localization and screening properties of bilayer graphene
Resumo:
An on-line algorithm is developed for the location of single cross point faults in a PLA (FPLA). The main feature of the valgorithm is the determination of a fault set corresponding to the response obtained for a failed test. For the apparently small number of faults in this set, all other tests are generated and a fault table is formed. Subsequently, an adaptive procedure is used to diagnose the fault. Functional equivalence test is carried out to determine the actual fault class if the adaptive testing results in a set of faults with identical tests. The large amount of computation time and storage required in the determination, a priori, of all the fault equivalence classes or in the construction of a fault dictionary are not needed here. A brief study of functional equivalence among the cross point faults is also made.
Resumo:
We report on the bacterial protein-based all-optical switches which operate at low laser power, high speed and fulfil most of the requirements to be an ideal all-optical switch without any moving parts involved. This consists of conventional optical waveguides coated with bacteriorhodopsin films at switching locations. The principle of operation of the switch is based on the light-induced refractive index change of bacteriorhodopsin. This approach opens the possibility of realizing proteinbased all-optical switches for communication network, integrated optics and optical computers.
Resumo:
The hardware and the software details of a user-friendly, simple, flexible and inexpensive pulse programmer using programmable counters interfaced to a microprocessor are described. The control of the various parameters that are required for NMR applications is implemented using the microprocessor. The basic hardware is extendable to other applications which require programmable pulse trains.
Resumo:
Online dynamic load modeling has become possible with the availability of Static Voltage Compensator (SVC) and Phasor Measurement Unit (PMU) devices. The power of the load response to the small random bounded voltage fluctuations caused from SVC can be measured by PMU for modelling purposes. The aim of this paper is to illustrate the capability of identifying an aggregated load model from high voltage substation level in the online environment. The induction motor is used as the main test subject since it contributes the majority of the dynamic loads. A test system representing simple electromechanical generator model serving dynamic loads through the transmission network is used to verify the proposed method. Also, dynamic load with multiple induction motors are modeled to achieve a better realistic load representation.
Resumo:
This paper describes a switching theoretic algorithm for the folding of programmable logic arrays (PLA). The algorithm is valid for both column and row folding, although it has been presented considering only the simple column folding. The pairwise compatibility relations among all the pairs of the columns of the PLA are mapped into a square matrix, called the compatibility matrix of the PLA. A foldable compatibility matrix (FCM), a new concept introduced by the author, is then derived from the compatibility matrix. A new theorem called the folding theorem is then proved. The theorem states that the existence of an m by 2m FCM is both necessary and sufficient to fold 2m columns of the n column PLA (2m ≤ n). Once an FCM is obtained, the ordered pairs of foldable columns and the re-ordering of the rows are readily determined.
Resumo:
This thesis utilises an evidence-based approach to critically evaluate and summarize effectiveness research on physiotherapy, physiotherapy-related motor-based interventions and orthotic devices in children and adolescents with cerebral palsy (CP). It aims to assess the methodological challenges of the systematic reviews and trials, to evaluate the effectiveness of interventions in current use, and to make suggestions for future trials Methods: Systematic reviews were searched from computerized bibliographic databases up to August 2007 for physiotherapy and physiotherapy-related interventions, and up to May 2003 for orthotic devices. Two reviewers independently identified, selected, and assessed the quality of the reviews using the Overview Quality Assessment Questionnaire complemented with decision rules. From a sample of 14 randomized controlled trials (RCT) published between January 1990 and June 2003 we analysed the methods of sampling, recruitment, and comparability of groups; defined the components of a complex intervention; identified outcome measures based on the International Classification of Functioning, Disability and Health (ICF); analysed the clinical interpretation of score changes; and analysed trial reporting using a modified 33-item CONSORT (Consolidated Standards of Reporting Trials) checklist. The effectiveness of physiotherapy and physiotherapy-related interventions in children with diagnosed CP was evaluated in a systematic review of randomised controlled trials that were searched from computerized databases from January 1990 up to February 2007. Two reviewers independently assessed the methodological quality, extracted the data, classified the outcomes using the ICF, and considered the level of evidence according to van Tulder et al. (2003). Results: We identified 21 reviews on physiotherapy and physiotherapy-related interventions and five on orthotic devices. These reviews summarized 23 or 5 randomised controlled trials and 104 or 27 observational studies, respectively. Only six reviews were of high quality. These found some evidence supporting strength training, constraint-induced movement therapy or hippotherapy, and insufficient evidence on comprehensive interventions. Based on the original studies included in the reviews on orthotic devices we found some short-term effects of lower limb casting on passive range of movement, and of ankle-foot orthoses on equinus walk. Long term effects of lower limb orthoses have not been studied. Evidence of upper limb casting or orthoses is conflicting. In the sample of 14 RCTs, most trials used simple randomisation, complemented with matching or stratification, but only three specified the concealed allocation. Numerous studies provided sufficient details on the components of a complex intervention, but the overlap of outcome measures across studies was poor and the clinical interpretation of observed score changes was mostly missing. Almost half (48%) of the applicable CONSORT-based items (range 28 32) were reported adequately. Most reporting inadequacies were in outcome measures, sample size determination, details of the sequence generation, allocation concealment and implementation of the randomization, success of assessor blinding, recruitment and follow-up dates, intention-to-treat analysis, precision of the effect size, co-interventions, and adverse events. The systematic review identified 22 trials on eight intervention categories. Four trials were of high quality. Moderate evidence of effectiveness was established for upper extremity treatments on attained goals, active supination and developmental status, and of constraint-induced therapy on the amount and quality of hand use and new emerging behaviours. Moderate evidence of ineffectiveness was found for strength training's effect on walking speed and stride length. Conflicting evidence was found for strength training's effect on gross motor function. For the other intervention categories the evidence was limited due to the low methodological quality and the statistically insignificant results of the studies. Conclusions: The high-quality reviews provide both supportive and insufficient evidence on some physiotherapy interventions. The poor quality of most reviews calls for caution, although most reviews drew no conclusions on effectiveness due to the poor quality of the primary studies. A considerable number of RCTs of good to fair methodological and reporting quality indicate that informative and well-reported RCTs on complex interventions in children and adolescents with CP are feasible. Nevertheless, methodological improvement is needed in certain areas of the trial design and performance, and the trial authors are encouraged to follow the CONSORT criteria. Based on RCTs we established moderate evidence for some effectiveness of upper extremity training. Due to limitations in methodological quality and variations in population, interventions and outcomes, mostly limited evidence on the effectiveness of most physiotherapy interventions is available to guide clinical practice. Well-designed trials are needed, especially for focused physiotherapy interventions.
Resumo:
Porous carbon oxygen-reducing electrodes incorporated with perovskite oxide catalysts are reported. It has been possible to fabricate high-performance oxygen-reducing electrodes by introducing La0.5Sr0.5CoO3 and La0.99Sr0.01NiO3 with the activated coconut-shell charcoal; these electrodes could sustain load currents as high as 1 A cm−2 without serious degradation. A model to explain oxygen-reducing activity of these oxides has been proposed.
Resumo:
Synthetic, natural, or composite, biomaterials occupy a key position in the management of disease and support continuous advancement of health care. Clinical utility of many permanent and biodegradable implants can be significantly improved via surface modification. Here, we discuss a novel polymer material developed from essential oil-based monoterpene alcohol using plasma polymerisation. The developed coatings are cytocompatible and limit adhesion and proliferation of a variety of pathogens. The coating can also be used to control degradation behaviour of resorbable materials, such as magnesium.
Resumo:
Ageing population and a multitude of neurological and cardiovascular illnesses that cannot be mitigated by medication alone have resulted in a significant growth in the number of patients that require implantable electronic devices. These range from sensors, gastric and cardiac pacemakers, cardioverter defibrillators, to deep brain, nerve, and bone stimulators. Long-term implants present specific engineering challenges, including low energy consumption and stable performance. Resorbable electronics may offer excellent short-term performance without the need for surgical removal. However, most electronic materials have poor bio- and cytocompatibility, resulting in immune reactions and infections. This paper reviews the current situation and highlights challenges for future advancements.