830 resultados para Pneumatice Pressure, Distal Radius Fracture, Dynamic Loading, Fracture Healing


Relevância:

100.00% 100.00%

Publicador:

Resumo:

?  Introduction ?  Bone fracture healing and healing problems ?  Biomaterial scaffolds and tissue engineering in bone formation -  Bone tissue engineering -  Biomaterial scaffolds -  Synthetic scaffolds -  Micro- and nanostructural properties of scaffolds -  Conclusion ?  Mesenchymal stem cells and osteogenesis -  Bone tissue -  Origin of osteoblasts -  Isolation and characterization of bone marrow derived MSC -  In vitro differentiation of MSC into osteoblast lineage cells -  In vivo differentiation of MSC into bone -  Factors and pathways controlling osteoblast differentiation of hMSC -  Defining the relationship between osteoblast and adipocyte differentiation from MSC -  MSC and sex hormones -  Effect of aging on osteoblastogenesis -  Conclusion ?  Embryonic, foetal and adult stem cells in osteogenesis -  Cell-based therapies for bone -  Specific features of bone cells needed to be advantageous for clinical use -  Development of therapeutic biological agents -  Clinical application concerns -  Conclusion ?  Platelet-rich plasma (PRP), growth factors and osteogenesis -  PRP effects in vitro on the cells involved in bone repair -  PRP effects on osteoblasts -  PRP effects on osteoclasts -  PRP effects on endothelial cells -  PRP effects in vivo on experimental animals -  The clinical use of PRP for bone repair -  Non-union -  Distraction osteogenesis -  Spinal fusion -  Foot and ankle surgery -  Total knee arthroplasty -  Odontostomatology and maxillofacial surgery -  Conclusion ?  Molecular control of osteogenesis -  TGF-β signalling -  FGF signalling -  IGF signalling -  PDGF signalling -  MAPK signalling pathway -  Wnt signalling pathway -  Hedgehog signalling -  Notch signalling -  Ephrin signalling -  Transcription factors regulating osteoblast differentiation -  Conclusion ?  Summary This invited review covers research areas of central importance for orthopaedic and maxillofacial bone tissue repair, including normal fracture healing and healing problems, biomaterial scaffolds for tissue engineering, mesenchymal and foetal stem cells, effects of sex steroids on mesenchymal stem cells, use of platelet-rich plasma for tissue repair, osteogenesis and its molecular markers. A variety of cells in addition to stem cells, as well as advances in materials science to meet specific requirements for bone and soft tissue regeneration by addition of bioactive molecules, are discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Giant cell tumour (GCT) is a benign but locally aggressive primary osteolytic bone tumour, prone to local recurrence after surgery. Denosumab is a human antibody against RANKL, an over-expressed ligand present on normal multinucleated cells, responsible for bone destruction in GCT. We report the case of a patient with an advanced GCT of the distal radius. The lesion was treated with adjuvant denosumab , followed by curettage. Clinical case: A 28 years old patient presented with a classical honeycomb osteolytic lesion in the left distal radius. Core-needle biopsy confirmed the diagnosis of GCT. Due to the proximity to the radio-carpal joint and advanced scalloping of the metaphyseal cortical bone, joint-salvage surgery was not possible. We initiated a neo-adjuvant treatment with denosumab (XGEVA), 120mg/ week for 1 month, followed by monthly injections for 6 months. During this time, a substantial bone recorticalization, without progression of the size of the tumour was noted. No local or systemic side effects were observed. We performed intra-lesional (curettage) excision and bone grafting after 6 months. Histological analysis revealed islets (10%) of viable tumour cells within fibrous tissue. Post-op evolution was eventless. Discussion: While surgery remains the treatment of choice for GCT, joint-salvage may not always be possible in case of extensive epiphyseal involvement. The presence of osteoclast-like giant cells seems to make those lesions prone to the specific anti-RANKL treatment with denosumab. Denosumab appears to slow down tumour growth and promote recorticalization of eroded bone. It might allow less aggressive surgery in selected cases.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This prospective study addresses early results of the treatment of acute acetabular fractures in elderly patients by total hip arthroplasty and cerclage wiring.Fifteen patients with an average age of 81 years were treated at our institution between February 1998 and December 2000. There were two transverse fractures, eight T-shaped fractures, two transverse fractures with associated posterior wall fracture, two posterior column fractures with associated posterior wall fracture, and one fracture of both columns. Treatment consisted of cerclage wiring of the fracture and primary non-cemented total hip replacement.All of the patients were followed for a mean of 36 months. Although there was one patient with three hip dislocations during the first 10 months after the operation, we found an excellent or good result for the entire group. During this relatively short follow-up period, we have not found a radiological loss of fracture reduction of more than 1 mm or a cup migration of more than 3.2 mm. All of the fractures healed and no loosening of the implant was evident.Primary total hip arthroplasty combined with internal fixation is a valid treatment option for acetabular fractures in the elderly. Preliminary results are convincing, but a bigger patient population and a longer follow-up time are necessary before we are able to draw final conclusions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A group of nine patients with a diaphyseal fracture of the humerus and treated with retrograde nailing were studied with a mean follow-up of 15.3 months. Six patients with a humeral fracture without neurological deficit showed a good shoulder and elbow mobility at the last visit. Three patients with neurological lesion preoperatively suffer from a diminished range of movement not related to the surgical procedure. During the operation and postoperatively we found no complication related to the implant and more precisely we could not find a iatrogenic fracture or nervous lesion except one intraoperative lesion of the radial nerve probably related to an important traction movement during reduction with complete remission. Consolidation has been achieved for all fractures but one. This patient suffers from a lesion of the brachial plexus with complete plegia of the arm and a vascular lesion. This patient had to be reoperated for an atrophic non-union by bone grafting and plate fixation. The retrograde nail is a good implant and must be considered in our treatment plans as much as conservative treatment or surgical treatment with plating, anterograde nailing or the use of an external fixator. Only then will we be able to give to the patient the most adapted treatment for his fracture.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

From August 91 to December 94, 20 external fixators were used for severely injured patients (avg. ISS 25.2). The fractures were essentially open book with or without lateral compression and vertical lesions. The indication for fixation was treatment of shock and stabilization in 8 cases, stabilization alone in 9 cases, and in 3 cases as complementary fixation after internal fixation of posterior lesions. The fixation of the pelvis was effective on the amount of blood loss. One acetabulum fracture required surgery, two patients had internal fixation for loss of reduction and two others for late pubic and posterior pain. The clinical results are good; they are more related to the severity of the initial lesion than to the mode of fixation or the quality of the reduction. No superficial sepsis or osteitis was observed in relation to the pins.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Eighteen patients with acetabular fractures, with a mean age of 76 years, were treated with cable fixation and acute total hip arthroplasty. Nine were T-shaped fractures, 4 associated transverse and posterior wall, 2 transverse, 2 posterior column and posterior wall, and 1 anterior and posterior hemitransverse fractures. One patient experienced 3 episodes of hip dislocation within 10 months after surgery. All the others had a good outcome at a mean follow-up time of 36 months. Radiographic assessment showed healing of the fracture and a satisfactory alignment of the cup without loosening. This option provides good primary fixation, stabilizes complex acetabular fractures in elderly patients, and permits early postoperative mobilization.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Trabecular bone score (TBS) is a recently-developed analytical tool that performs novel grey-level texture measurements on lumbar spine dual X-ray absorptiometry (DXA) images, and thereby captures information relating to trabecular microarchitecture. In order for TBS to usefully add to bone mineral density (BMD) and clinical risk factors in osteoporosis risk stratification, it must be independently associated with fracture risk, readily obtainable, and ideally, present a risk which is amenable to osteoporosis treatment. This paper summarizes a review of the scientific literature performed by a Working Group of the European Society for Clinical and Economic Aspects of Osteoporosis and Osteoarthritis. Low TBS is consistently associated with an increase in both prevalent and incident fractures that is partly independent of both clinical risk factors and areal BMD (aBMD) at the lumbar spine and proximal femur. More recently, TBS has been shown to have predictive value for fracture independent of fracture probabilities using the FRAX® algorithm. Although TBS changes with osteoporosis treatment, the magnitude is less than that of aBMD of the spine, and it is not clear how change in TBS relates to fracture risk reduction. TBS may also have a role in the assessment of fracture risk in some causes of secondary osteoporosis (e.g., diabetes, hyperparathyroidism and glucocorticoid-induced osteoporosis). In conclusion, there is a role for TBS in fracture risk assessment in combination with both aBMD and FRAX.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thermogravimetry was applied to investigate the effects of temperature and atmosphere on conversion of sulfur dioxide (SO2) absorbed by limestone. Ranges of temperature and particle size were studied, typical of fluidized-bed coal combustion. Isothermal experiments were performed at different temperatures (between 750 and 950 ºC) under local atmospheric pressure (~ 697 mmHg) in dynamic atmospheres of air and nitrogen. The maximum conversion was 29% higher in nitrogen atmosphere than in air atmosphere. The optimum conversion temperature was found at 831 ºC in air atmosphere and at 894 ºC in nitrogen atmosphere.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It is necessary to use highly specialized robots in ITER (International Thermonuclear Experimental Reactor) both in the manufacturing and maintenance of the reactor due to a demanding environment. The sectors of the ITER vacuum vessel (VV) require more stringent tolerances than normally expected for the size of the structure involved. VV consists of nine sectors that are to be welded together. The vacuum vessel has a toroidal chamber structure. The task of the designed robot is to carry the welding apparatus along a path with a stringent tolerance during the assembly operation. In addition to the initial vacuum vessel assembly, after a limited running period, sectors need to be replaced for repair. Mechanisms with closed-loop kinematic chains are used in the design of robots in this work. One version is a purely parallel manipulator and another is a hybrid manipulator where the parallel and serial structures are combined. Traditional industrial robots that generally have the links actuated in series are inherently not very rigid and have poor dynamic performance in high speed and high dynamic loading conditions. Compared with open chain manipulators, parallel manipulators have high stiffness, high accuracy and a high force/torque capacity in a reduced workspace. Parallel manipulators have a mechanical architecture where all of the links are connected to the base and to the end-effector of the robot. The purpose of this thesis is to develop special parallel robots for the assembly, machining and repairing of the VV of the ITER. The process of the assembly and machining of the vacuum vessel needs a special robot. By studying the structure of the vacuum vessel, two novel parallel robots were designed and built; they have six and ten degrees of freedom driven by hydraulic cylinders and electrical servo motors. Kinematic models for the proposed robots were defined and two prototypes built. Experiments for machine cutting and laser welding with the 6-DOF robot were carried out. It was demonstrated that the parallel robots are capable of holding all necessary machining tools and welding end-effectors in all positions accurately and stably inside the vacuum vessel sector. The kinematic models appeared to be complex especially in the case of the 10-DOF robot because of its redundant structure. Multibody dynamics simulations were carried out, ensuring sufficient stiffness during the robot motion. The entire design and testing processes of the robots appeared to be complex tasks due to the high specialization of the manufacturing technology needed in the ITER reactor, while the results demonstrate the applicability of the proposed solutions quite well. The results offer not only devices but also a methodology for the assembly and repair of ITER by means of parallel robots.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hitsatuissa rakenteissa on paljon hitsien aiheuttamia epäjatkuvuuskohtia, jotka ovat alttiita vaurioitumaan väsyttävän kuormituksen alaisina. Standardit ja normit auttavat suunnittelua rakenneyksityiskohtien analysoinnissa, mutta ohjeiden arvot vaihtelevat paljon. Onkin tär-keää päättää, mitä standardia tai normia käytetään ja saada tutkimustuloksia tukemaan ohjeen käyttöä. Tämä työ on tehty Konecranes Finland Oy:lle. Työn tarkoituksena on etsiä käytössä olevi-en ohjeiden joukosta suunnittelun kannalta parhaiten todellista rakennetta kuvaava. Työssä esitellään käytössä olevia standardeja ja normeja sekä vertaillaan niiden välisiä eroja rakenneyksityiskohdan väsymiskestävyyden määrittämisessä. Työssä tarkastellaan myös hitsatun rakenteen väsymiseen vaikuttavia tekijöitä sekä väsymisanalyysissä käytet-täviä menetelmiä. Tutkittavaan liitokseen valittiin kolme erilaista hitsiä, yksi –ja kaksipuolinen pienahitsi sekä katkopienahitsi. Elementtimenetelmän avulla luotiin malleja koekappaleista ja laskettiin niille väsymiskestävyydet. Tämä lisäksi väsymistä tarkasteltiin väsytyskokeilla, jotka suoritti Lappeenrannan Teknillisen Yliopiston Teräsrakenteiden laboratorio. Lopputuloksena työstä saatiin tietoa hitsien väsymiskestävyyksistä. Liitosten väsymiskes-tävyydet olivat hyviä ja varsinkin katkopienahitsin tulokset olivat odotettua paremmat. Kat-kopienahitsin väsymiskestävyys vaatii tämän työn tulosten perusteella lisää tutkimista.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The hemodynamic responses to acute (45 min) partial aortic constriction were studied in conscious intact (N = 7) or sinoaortic denervated (SAD) adult male Wistar rats (280-350 g, N = 7) implanted with carotid and femoral arterial catheters, a pneumatic cuff around the abdominal aorta and a pulsed Doppler flow probe to measure changes in aortic resistance. In addition, the hypertensive response and the reflex bradycardia elicited by total (N = 8) vs partial (N = 7) aortic constriction (monitored by maintenance of the pressure distal to the cuff at 50 mmHg) were compared in two other groups of intact rats. Intact rats presented a smaller hypertensive response (26 to 40% above basal level) to partial aortic constriction than SAD rats (38 to 58%). The calculated change in aortic resistance imposed by constriction of the aorta increased progressively only in intact rats, but was significantly smaller (193 to 306%) than that observed (501 to 591%) in SAD rats. Intact rats showed a significant bradycardia (23 to 26% change in basal heart rate) throughout coarctation, whereas the SAD rats did not (1 to 3%). Partial or total occlusion of the aorta induced similar hypertensive responses (37-38% vs 24-30% for total constriction) as well as reflex bradycardia (-15 to -17% vs -22 to -33%) despite a greater gradient in pressure (97-98 vs 129-140 mmHg) caused by total constriction. The present data indicate that the integrity of the baroreflex in intact rats can cause the hypertensive response to level off at a lower value than in SAD rats despite a progressive increase in aortic resistance. In addition, they also indicate that the degree of partial aortic constriction by maintenance of the pressure distal to the cuff at 50 mmHg already elicits a maximal stimulation of the arterial baroreflex

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to compare bone speed of sound (SOS) measured by quantitative ultrasound, circulating levels of IGF- 1 and biochemical markers of bone turnover in pre- (Pr) and post-menarcheal (Po) synchronized swimmers (SS) and controls (NS). Seventy participants were recruited: 8 PrSS, 22 PoSS, 20 PrNS, and 20 PoNS. Anthropometric measures of height, weight, skeletal maturity and percent body fat were taken, and dietary intake evaluated using 24-hour recall. Bone SOS was measured at the distal radius and mid-tibia and blood samples analyzed for IGF-1, osteocalcin, NTx, and 25-OH vitamin D. Results demonstrated maturational effects on bone SOS, IGF-1 and bone turnover (p<0.05), with no differences observed between SS and NS. Main effects were observed for a reduced caloric intake in SS compared to NS (p<0.05). Therefore, SS does not offer additive affects on bone strength but imparts no adverse affects to skeletal health in these athletes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Over the last two decades, the prevalence of obesity in the general population has been steadily increasing. Obesity is a major issue in scientific research because it is associated with many health problems, one of which is bone quality. In adult females, adiposity is associated with increased bone mineral density, suggesting that there is a protective effect of fat on bone. However, the association between adiposity and bone strength during childhood is not clear. Thus, the purpose of this study was to compare bone strength, as reflected by speed of sound (SOS), of overweight and obese girls and adolescents with normal-weight age-matched controls. Data from 75 females included normal-weight girls (G-NW; body fat:::; 25%; n = 21), overweight and obese girls (GOW; body fat ~ 28%; n = 19), normal-weight adolescents (A-NW, body fat:::; 25%; n = 13) and overweight and obese adolescents (A-OW; body fat ~ 28%; n = 22). Nutrition was assessed with a 24-hour recall questionnaire and habitual physical activity was measured for one week using accelerometry. Using quantitative ultrasound (QUS; Sunlight Omnisense™), bone SOS was measured at the distal radius and mid-tibia. No differences were found between groups in daily total energy, calcium or vitamin D intake. However, all groups were below the recommended daily calcium intake of 1300 mg (Osteoporosis Canada, 2008). Adolescents were significantly less active than girls (14.7 ± 0.6 vs. 6.3 ± 0.6% active for G and A, respectively). OW accumulated significantly less minutes of moderate-to-very vigorous physical activity per day (MVPA) than NW in both age groups (114 ± 6 vs. 57 ± 5 min/day for NW and OW, i respectively). Girls had significantly lower radial SOS (3794 ± 87 vs. 3964 ± 64 mls for G-NW and A-NW, respectively), and tibial SOS (3678 ± 86 vs. 3878 ± 52 mls for G-NW and A-NW, respectively) than adolescents. Radial SOS was similar in the two adiposity groups within each age group. However, tibial SOS was lower in the two overweight groups (3601 ± 75 mls vs. 3739 ± 134 mls for G-OW and A-OW, respectively) compared with the age-matched normal-weight controls. Body fat percentage negatively correlated with tibial SOS in the study sample as a whole (r = -0.30). However, when split into groups, percent bo~y fat correlated with tibial SOS only in the A-OW group (r = -0.53). MVPA correlated with tibial SOS (r = 0.40), once age was partialed out. In conclusion, in contrast withthe higher bone strength characteristic of obese adult women, overweight and obese girls and adolescents are characterized by low tibial bone strength, as assessed with QUS. The differences between adiposity groups in tibial SOS may be at least partially due to the reduced weight-bearing physical activity levels in the overweight girls and adolescents. However, other factors, such as hormonal influences associated with high body fat may also playa role in reducing bone strength in overweight girls. Further research is required to reveal the mechanisms causing low bone strength in overweight and obese children and adolescents.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to examine the associations between bone speed of sound (SOS) and body composition, osteoporosis-related health behaviours, and socioeconomic status (SES) in adolescent females. A total of 442 adolescent females in grades 9-11 participated. Anthropometric measures of height, body mass, and percent body fat were taken, and osteo-protective behaviours such as oral contraceptive use (OC), physical activity and daily calcium intake were evaluated using self-report questionnaires. Bone SOS was measured by transaxial quantitative ultrasound (QUS) at the distal radius and mid-tibia. The results suggest that fat mass is a significant negative predictor of tibial SOS, while lean mass is positively associated with radial SOS scores and calcium intake was positively associated with tibial SOS scores (p