203 resultados para Plaster.
Resumo:
The objective of this study was to assess if the positioning of the impression tray could cause plaster casts distortion during gypsum setting time. fifteen pairs of master models were cast with alginate impression material and immediately poured with gypsum. impressions were allowed to set with the tray in the not inverted position (group a) or in the inverted position (group b). the plaster models were digitized using a laser scanner (3shape r-700, 3shape a/s). tooth size measurements and distances were obtained using o3d software (widialabs, brasil) measurement tools. data were analyzed by paired t test and linear regression with 5% significance. most measurements of both groups were similar, except for the lower intermolar distance. it was not possible to corroborate the presence of distortions owing to the position of the impression tray during gypsum setting time.
Resumo:
Diagnosis and planning stages are critical to the success of orthodontic treatment, in which the orthodontist should have many elements that contribute to the most appropriate decision-making. The orthodontic set-up is an important resource in the planning of corrective orthodontics therapy. It consists of the repositioning of the teeth previously removed from the study dental casts and reassembled on its remaining basis. When properly made, the set-up allows a three-dimensional preview of problems and limitations of the case, assisting in decision-making regarding tooth extractions in cases with problems of space, amount of anchorage loss extent and type of tooth movement, discrepancy of dental arch perimeter, discrepancy of inter-arch tooth volume, among others, indicating the best option for treatment. This paper outlines the most important steps for its confection, an evaluation system and its application in the preparation of orthodontic treatment planning.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The cares at the manipulation of the alginate (condensation, disinfection of the impression and the time elapsed until the leak of the plaster) deserve special attention considering the great amount of distortions occurring every time the impression is not fill of plaster in a brief space of time and appropriate storage conditions. Besides its adaptation to the plaster suffers influence of the events happened after the impression is removed of the mouth. The purpose of this research was to evaluate the wetting capacity of three brands of alginate (Jeltrate™,Hydrogum™ e Orthoprint™) by the plaster type III (Rio™) under the influence of disinfection by sodium hypochlorite 1% sprays and the time of storage of 15 minutes,30 minutes, 1 hour, 6, 12 and 24 hours. There were made 60 impressions of each brand of alginate divided in two groups (water and sodium hypochlorite 1%) rearranged after the application of the sodium hypochlorite spray according to the storage time (15 or 30 minutes and 1,6,12, or 24 hours). On the surface of the impressions 2ml of plaster were flowed, proportioned and condensed in agreement with manufacturer‘s instructions. After the final setting expansion the casts were sectioned vertically and medially, regularized at the cut surface (emery paper 400) and setted for reading the contact angle at the microscope Carl Zeiss. The obtained results, submitted to statistical treatment (ANOVA) revealed significant differences when compared the employed solutions (water and sodium hypochlorite 1%) and the time of storage. The sodium hypochlorite 1% exhibited the smallest contact angles and the times of storage of 15 minutes and 6 hours the smallest and larger angles, respectively. It can be concluded that the alginate impressions exhibited larger adaptation to the plaster when disinfected by hypochlorite of sodium 1% and stocked by 15 minutes.
Resumo:
Purpose: In order to assist in the selection of artificial teeth for complete dentures, this study aimed to assess the relationship between horizontal and vertical measurements of the face and the morphology of the maxillary central incisor. Materials and Methods: This was a study of 50 plaster casts and 100 teleradiographs - 50 in lateral norm and 50 in frontal norm, belonging to 50 individuals, Caucasian, with a naturally optimal occlusion, matching at least four of the six keys of Andrews. Images of the upper central incisors were obtained by scanning the plaster casts (three-dimensional) and subjectively classified by three examiners as oval, triangular or quadrangular. Facial measures (vertical and horizontal) were defined by means of teleradiographs. In order to check inter-examiner agreement on the classification of central incisor, the Kappa test was used. To verify whether data had normal distribution, the Kolmogorov-Smirnov test was used ( P > 0.2) was used. One-way analysis of variance was employed to assess the association between variables (P > 0.05). Results: When vertical measurements were compared with the three incisor shapes, there was no statistically significant difference (P > 0.05): Triangular (0.54), oval (0.63) and quadrangular (0.51). Similarly, no difference (P > 0.05) was found for facial width (139.08, 143.37, 141.65), maxillary width (76.68, 78.99, 76.91) and mandibular width (103.47, 105.50, 103.11). Conclusions: The majority of cases showed that horizontal and vertical measurements of the face cannot be used as a reference for determining the morphology of the maxillary central incisor crown. It is relevant to analyze and compare other morphological structures to improve the oral health-related quality of life for the conventional denture wearer.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The construction industry is one of the greatest sources of pollution because of the high level of energy consumption during its life cycle. In addition to using energy while constructing a building, several systems also use power while the building is operating, especially the air-conditioning system. Energy consumption for this system is related, among other issues, to external air temperature and the required internal temperature of the building. The facades are elements which present the highest level of ambient heat transfer from the outside to the inside of tall buildings. Thus, the type of facade has an influence on energy consumption during the building life cycle and, consequently, contributes to buildings' CO2 emissions, because these emissions are directly connected to energy consumption. Therefore, the aim is to help develop a methodology for evaluating CO2 emissions generated during the life cycle of office building facades. The results, based on the parameters used in this study, show that facades using structural glazing and uncolored glass emit the most CO2 throughout their life cycle, followed by brick facades covered with compound aluminum panels or ACM (Aluminum Composite Material), facades using structural glazing and reflective glass and brick facades with plaster coating. On the other hand, the typology of facade that emits less CO2 is brickwork and mortar because its thermal barrier is better than structural glazing facade and materials used to produce this facade are better than brickwork and ACM. Finally, an uncertainty analysis was conducted to verify the accuracy of the results attained. (C) 2011 Elsevier Inc. All rights reserved.
Resumo:
Purpose: The aim of this study was to evaluate the accuracy of cone-beam computed tomography (CBCT) for measuring the buccal bone volume around dental implants. Materials and methods: Three to six implants were inserted into the anterior maxilla of eight skulls, depending on the availability of bone, and after this, the CBCT was performed. By means of CBCT image, measurements of the bone wall at three points of the implant were obtained, analyzed and compared with those obtained in the plaster skull casting. Results: The results showed that for the three points of the implants, no statistically significant difference in the measurements was obtained from the plaster model and CBCT images. Conclusions: CBCT can be a useful tool for assessing buccal bone volume along the implant. To cite this article:?Shiratori LN, Marotti J, Yamanouchi J, Chilvarquer I, Contin I, Tortamano-Neto P. Measurement of buccal bone volume of dental implants by means of cone-beam computed tomography.?Clin. Oral Impl. Res. 23, 2012; 797804.?doi: 10.1111/j.1600-0501.2011.02207.x
Resumo:
INTRODUCTION: In orthodontics, determining the facial type is a key element in the prescription of a correct diagnosis. In the early days of our specialty, observation and measurement of craniofacial structures were done directly on the face, in photographs or plaster casts. With the development of radiographic methods, cephalometric analysis replaced the direct facial analysis. Seeking to validate the analysis of facial soft tissues, this work compares two different methods used to determining the facial types, the anthropometric and the cephalometric methods. METHODS: The sample consisted of sixty-four Brazilian individuals, adults, Caucasian, of both genders, who agreed to participate in this research. All individuals had lateral cephalograms and facial frontal photographs. The facial types were determined by the Vert Index (cephalometric) and the Facial Index (photographs). RESULTS: The agreement analysis (Kappa), made for both types of analysis, found an agreement of 76.5%. CONCLUSIONS: We concluded that the Facial Index can be used as an adjunct to orthodontic diagnosis, or as an alternative method for pre-selection of a sample, avoiding that research subjects have to undergo unnecessary tests.
Resumo:
La sindrome di Noonan (SN) è una patologia a trasmissione autosomica dominante caratterizzata da bassa statura, difetti cardiaci congeniti, dismorfia facciale. In letteratura sono stati pubblicati pochi case reports riguardanti le condizioni orali-facciali in pazienti affetti da SN. Obiettivo. Individuare patologie di pertinenza ortopedico-ortodontica caratteristiche della sindrome utilizzando un campione di pazienti con diagnosi di SN. Metodi. Un gruppo di 10 pazienti affetti da SN è stato sottoposto a esame obiettivo extraorale ed intraorale, ortopantomografia, teleradiografia latero-laterale, impronte delle arcate dentarie. Le misurazioni sulle TLL sono state effettuate sulla base dell'analisi MBT; i valori palatali provengono dai modelli di studio dell’arcata superiore. È stata utilizzato il test t-Student per mettere a confronto il gruppo di studio e il gruppo di controllo riguardo le misure cefalometriche e i valori palatali. Risultati. Nel gruppo di studio sono state rilevate anomalie di numero (un dente deciduo soprannumerario e una agenesia di un dente permanente). Il test t-Student rivela differenze statisticamente significative per 7 variabili cefalometriche su 13 e per 2 variabili palatali. Conclusioni. Basandosi su questo studio è possibile concludere che i pazienti con SN mostrano II classe scheletrica di tipo mandibolare, crescita iperdivergente, tendenza al morso aperto scheletrico, palatoversione degli incisivi superiori, palato stretto. Questi risultati possono fornire informazioni utili sia per la diagnosi di SN sia per la pianificazione del corretto trattamento ortodontico.
Resumo:
Objective: To develop yardsticks for assessment of dental arch relationship in young individuals with repaired complete bilateral cleft lip and palate appropriate to different stages of dental development. Participants: Eleven cleft team orthodontists from five countries worked on the projects for 4 days. A total of 776 sets of standardized plaster models from 411 patients with operated complete bilateral cleft lip and palate were available for the exercise. Statistics: The interexaminer reliability was calculated using weighted kappa statistics. Results: The interrater weighted kappa scores were between .74 and .92, which is in the "good" to "very good" categories. Conclusions: Three bilateral cleft lip and palate yardsticks for different developmental stages of the dentition were made: one for the deciduous dentition (6-year-olds' yardstick), one for early mixed dentition (9-year-olds' yardstick), and one for early permanent dentition (12-year-olds' yardstick).
Enamel loss and adhesive remnants following bracket removal and various clean-up procedures in vitro
Resumo:
This study evaluated the enamel loss and composite remnants after debonding and clean-up. The tested null hypothesis is that there are no differences between different polishing systems regarding removing composite remnants without damaging the tooth surface. Brackets were bonded to 75 extracted human molars and removed after a storage period of 100 hours. The adhesive remnant index (ARI) was evaluated. The clean-up was carried out with five different procedures: 1. carbide bur; 2. carbide bur and Brownie and Greenie silicone polishers; 3. carbide bur and Astropol polishers; 4. carbide bur and Renew polishers; and 5. carbide bur, Brownie, Greenie and PoGo polishers. Silicone impressions were made at baseline (T0) and after debonding (T1) and polishing (T2) to produce plaster replicas. The replicas were analysed with a three-dimensional laser scanner and measured with analytical software. Statistical analysis was performed with the Kruskal-Wallis test and pairwise Wilcoxon tests with Bonferroni-Holm adjustment (α = 0.05). Enamel breakouts after debonding were detectable in 27 per cent of all cases, with a mean volume loss of 0.02 mm(3) (±0.03 mm(3)) and depth of 44.9 μm (±48.3 μm). The overall ARI scores was 3 with a few scores of 1 and 2. The composite remnants after debonding had a mean volume of 2.48 mm(3) (±0.92 mm(3)). Mean volume loss due to polishing was 0.05 mm(3) (±0.26 mm(3)) and the composite remnants had a mean volume of 0.22 mm(3) (±0.32 mm(3)). There were no statistically significant differences in volumetric changes after polishing (P = 0.054) between the different clean-up methods. However, sufficient clean-up without enamel loss was difficult to achieve.
Resumo:
Yardsticks have been developed to measure dental arch relations in cleft lip and palate (CLP) patients as diagnostic proxies for the underlying skeletal relationship. Travelling with plaster casts to compare results between CLP centres is inefficient so the aim of this study was to investigate the reliability of using digital models or photographs of dental casts instead of plaster casts for rating dental arch relationships in children with complete bilateral cleft lip and palate (CBCLP). Dental casts of children with CBCLP (n=20) were included. Plaster casts, digital models and photographs of the plaster casts were available for all the children at 6, 9, and 12 years of age. All three record formats were scored using the bilateral cleft lip and palate (BCLP) yardstick by four observers in random order. No significant differences were found for the BCLP yardstick scores among the three formats. The interobserver weighted kappa scores were between 0.672 and 0.934. Comparison between the formats per observer resulted in weighted kappa scores between 0.692 and 0.885. It is concluded that digital models and photographs of dental casts can be used for rating dental arch relationships in patients with CBCLP. These formats are a reliable alternative for BCLP yardstick assessments on conventional plaster casts.
Resumo:
This study investigates the influence of 17β-estradiol (E2) on nitric oxide (NO) production in endothelial cell cultures and the effect of topical E2 on the survival of skin flap transplants in a rat model. Human umbilical vein endothelial cells were treated with three different E2 concentrations and nitrite (NO2) concentrations, as well as endothelial nitric oxide synthase (eNOS) protein expressions were analyzed. In vivo, random-pattern skin flaps were raised in female Wistar rats 14 days following ovariectomy and treated with placebo ointment (group 1), E2 as gel (group 2), and E2 via plaster (group 3). Flap perfusion, survival, and NO2 levels were measured on postoperative day 7. In vitro, E2 treatment increased NO2 concentration in cell supernatant and eNOS expression in cell lysates (p < 0.05). In vivo, E2 treated (gel and plaster groups) demonstrated significantly increased skin flap survival compared to the placebo group (p < 0.05). E2 plaster-treated animals exhibited higher NO2 blood levels than placebo (p < 0.05) paralleling the in vitro observations. E2 increases NO production in endothelial cells via eNOS activation. Topical E2 application can significantly increase survival of ischemically challenged skin flaps in a rat model and may augment wound healing in other ischemic situations via activation of NO production.
Resumo:
A new system for computer-aided corrective surgery of the jaws has been developed and introduced clinically. It combines three-dimensional (3-D) surgical planning with conventional dental occlusion planning. The developed software allows simulating the surgical correction on virtual 3-D models of the facial skeleton generated from computed tomography (CT) scans. Surgery planning and simulation include dynamic cephalometry, semi-automatic mirroring, interactive cutting of bone and segment repositioning. By coupling the software with a tracking system and with the help of a special registration procedure, we are able to acquire dental occlusion plans from plaster model mounts. Upon completion of the surgical plan, the setup is used to manufacture positioning splints for intraoperative guidance. The system provides further intraoperative assistance with the help of a display showing jaw positions and 3-D positioning guides updated in real time during the surgical procedure. The proposed approach offers the advantages of 3-D visualization and tracking technology without sacrificing long-proven cast-based techniques for dental occlusion evaluation. The system has been applied on one patient. Throughout this procedure, we have experienced improved assessment of pathology, increased precision, and augmented control.