959 resultados para Pigments. Polymerization Complexes method. Fractional factorial design


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effect of operational variables and their interaction in TPR profiles was studied using a fractional factorial experimental design. The heating rate and the reducing agent concentration were found to be the most important variables determining the resolution and sensitivity of the technique. They showed opposite effects. Therefore, they should be manipulated preferentially in order to obtain optimized TPR profiles. The effect of sample particle size was also investigated. The tests were carried out within a Cu/Zn/Al2O3 catalyst used for the water-gas shift reaction that presented two distinct species of Cu2+ in TPR profiles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The influences of the spray-drying parameters and the type of nanoparticles (nanocapsules or nanospheres) on the characteristics of nanoparticle-coated diclofenac-loaded microparticles were investigated by using a factorial design 3². Gastrointestinal tolerance following oral administration in rats was evaluated. Formulations were selected considering the best yields, the best encapsulation efficiencies and the lowest water contents, presenting surfaces completely coated by nanostructures and a decrease in the surface areas in relation to the uncoated core. In vitro drug release demonstrated the influence of the nanoparticle-coating on the dissolution profiles of diclofenac. Nanocapsule-coated microparticles presented a protective effect on the gastrointestinal mucosa.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The liquid-liquid extraction with the low temperature partition technique was developed for the analysis of four pyrethroids in water by CG. Using a factorial design the extraction technique was optimised evaluating the effect of the variables ionic strength, contact time and proportion between sample and solvent volumes. The validation parameters sensitivity, precision, accuracy and detection and quantification limits were evaluated. The LOD and LOQ of the method varied from 1.1 to 3.2 µg L-1 and 2.7 to 9.5 µg L-1, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper reports the development of a methodology for simultaneously determining As, Cd and Pb, employing GF AAS with polarized Zeeman-effect background correction. In order to make the procedure applicable, the influence of pyrolysis and atomization temperatures and the amount of chemical modifiers were studied. Factorial and central composite designs were used to optimize these variables. Precision and accuracy of the method were investigated using Natural Water Reference material, Nist SRM 1640. Results are in agreement with certified values at the 95% confidence limit when the Student t-test is used. This methodology was used for quality control of purified water for hemodialysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pyrazinoic acid esters have been synthesized as prodrugs of pyrazinoic acid. In the literature, its preparation is reported through the reaction of pyrazinoyl chloride with alcohols and the reaction with DCC/DMAP. In this work, it is reported a 2² factorial design to evaluate the preparation of these esters through the substitution of alkyl bromides with carboxylate anion. The controlled factors were alkyl chain length of bromides (ethyl and hexyl) and the used base (triethylamine and DBU). Results revealed that the used base used has significant effect on yield, and alkyl bromide used has neither significant influence, nor its interaction effect with base.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The decomposition of detergent powder samples in a microwave oven and autoclave was evaluated. To establish the best experimental conditions a 2(5) factorial design was performed, varying the conditions in autoclave and microwave digestion and flow system parameters for the determination of phosphorus. The best composition was: 0.2 mL sulfuric acid; 500 W power and a 2 min time interval; 6 mmol L-1 of ascorbic acid and 16 mmol L-1 of molybdate to flow system. This factor levels use less reagents than the reference method. No statistically significant differences were found between the autoclave and microwave oven responses at the 95% confidence level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work describes the establishment of dissolution test conditions for 75 mg cinnarizine capsules using a multivariate approach. A 2³ full factorial design was carried out to achieve the best conditions and HCl 0.1 mol L-1 as dissolution medium, basket as apparatus at 100 rpm and collect time at 30 min were considered adequate. The quantification was carried out by spectrophotometry at 251 nm. Both dissolution procedure and analytical method were validated and all parameters were within the acceptable limits. Since there is no official monograph for this pharmaceutical product, this dissolution test could be applied for quality control routine.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to standardize the extractive solution of Syzygium cumini. The extractive solution was selected through a full factorial design, considering the extraction method (maceration-5-days, turbo extraction, percolation), extractor solvent (ethanol 50, 70, 96%) and plant material particle size 0.302 mm into a plant:solvent ratio (1:10), using the dried residue and antimicrobial activity determination as evaluation criteria. The tests were performed in triplicate. It appeared that the percolation is the best procedure extractive, and ethanol mixture: water (50:50) the best solvent. ANOVA analysis showed the importance of these parameters.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A factorial design applied in a voltammetric stripping method for the measurement of Ag(I) in natural water is described. The procedure is based on the effective pre-concentration of silver ions on electrode surface. The calibration graph was linear in the silver concentration range from 7.92 x 10"7 to 1.07 x 10"5 mol L"1 with a detection limit of 3.81 x 10-7 mol L-1. The determination of Ag(I) in natural water samples was carried out satisfactory with the proposed electrode.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A procedure for the simultaneous determination of Cr, Ni, and V in urine by electrothermal atomic absorption spectrometry (ET AAS) was optimized by factorial design, and performed at a pyrolysis and atomization temperatures of 1300 and 2500 ºC, respectively, using 15 µg de Mg(NO3)2 as chemical modifier. Characteristics mass of 14, 6 and 220 ρg and detection limits of the method of 0.07, 0.38 and 0.75 µg L-1 were obtained for Cr, Ni and V respectively. The methodology was validated using a Liphochek Urine Metals Control sample (Bio-Rad) (P=0.05). The methodology was applied to samples of voluntary Venezuelan people, not environmentally exposed to specific emissions, and results ranging from < LOD-1.1 and 1.3-3.3 µg L-1 was observed for Cr and V, respectively, and not detectable levels for Ni.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work applied a 2² factorial design to the optimization of the extraction of seven elements (calcium, magnesium, potassium, iron, zinc, copper and manganese) in brachiaria leaves, determined by flame atomic absorption spectrometry. The factors sample mass and digestion type were evaluated at two levels: 200/500 mg, and dry/wet, respectively. Principal component analysis allowed simultaneous discrimination of all the significant effects in one biplot. Wet digestion and mass of 200 mg were considered the best conditions. The decrease of 60% in sample mass allowed to save costs and reagents. The method was validated through the estimation of figures of merit.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study, a method for determination of hexavalent chromium in aqueous samples using liquid-liquid microextraction (LLME) and detection by Flame Atomic Absorption Spectrometry (F AAS) was developed. The LLME procedure was based on the extraction of Cr (VI) by acetone at a sample pH of 1.2. The use of saturated ammonium sulphate solution allowed effective separation of the aqueous and organic phases and acetone extracted chromium. The sample pH, acetone volume and stirring time were optimized by a full factorial design.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A flow-injection system with sample and reagent addition by the synchronous merging zones approach for calcium determination in milk by flame AAS is proposed. Main parameters were optimized using a factorial design with central point. The optimum conditions were 2.5% (m/v) for La concentration, 8 mL min-1 for the carrier flow-rate, 20 cm for coiled reactor and 250 ìL for sample volume. Different sample preparation procedures were evaluated such as dilution in water or acid and microwave-assisted decomposition using concentrated or diluted acids. The optimized flow system was applied to determine Ca in eleven commercial milk samples and two standard reference materials diluted in water. Similar calcium levels were encountered comparing the results obtained by the proposed method (dilution in water) with those obtained using microwave-oven digestion. Results obtained in two standard reference materials were in agreement at 95% confidence level with those certified. Recoveries of spiked samples were in the 93% - 116% range. Relative standard deviation (n = 12) was < 5.4% and the sample throughput was 150 measurements per hour, corresponding to a consumption of 250 µL of sample and 6.25 mg La per determination.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this work was to evaluate the initial growth and the physiological characteristics of eucalypt submitted to different managements of signalgrass. The experiment was conducted in a protected environment, using a randomized blocks design with five repetitions. The treatments were arranged in a (5 x 2) + 1 factorial design, and the first factor corresponded to the types of weed management (no control; chemical control keeping the signalgrass shoot on the soil; chemical control with removal of the signalgrass shoot; mechanical control keeping the signalgrass shoot on the soil, and mechanical control with removal of the signalgrass shoot); the second factor corresponded to the two weeds species (U. brizantha and U. decumbens) and a control relative to the eucalypt in monoculture. The eucalypt growth was not affected by the presence of the Urochloa species until 50 days after treatments (DAT). However, the coexistence of these species with eucalypt for 107 DAT reduced the collar diameter, total dry matter, and the leaf area, but did not alter the characteristics related to photosynthesis and transpiration. The control method adopted, with removal or maintenance of the signalgrass shoot, regardless of species, did not change the initial eucalypt growth. It can be concluded that the coexistence of eucalypt with Urochloa decumbens or Urochloa brizantha for 105 days reduces the eucalypt growth. However, the use of chemical or mechanical control, with or without removal of signalgrass residue, were effective methods to prevent interference of these weeds.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this work was to make tofu from soybean cultivar BRS 267 under different processing conditions in order to evaluate the influence of each treatment on the product quality. A fractional factorial 2(5-1) design was used, in which independent variables (thermal treatment, coagulant concentration, coagulation time, curd cutting, and draining time) were tested at two different levels. The response variables studied were hardness, yield, total solids, and protein content of tofu. Polynomial models were generated for each response. To obtain tofu with desirable characteristics (hardness ~4 N, yield 306 g tofu.100 g-1 soybeans, 12 g proteins.100 g-1 tofu and 22 g solids.100 g-1 tofu), the following processing conditions were selected: heating until boiling plus 10 minutes in water bath, 2% dihydrated CaSO4 w/w, 10 minutes coagulation, curd cutting, and 30 minutes draining time.