149 resultados para Piezo


Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

New actuation technology in functional or "smart" materials has opened new horizons in robotics actuation systems. Materials such as piezo-electric fiber composites, electro-active polymers and shape memory alloys (SMA) are being investigated as promising alternatives to standard servomotor technology [52]. This paper focuses on the use of SMAs for building muscle-like actuators. SMAs are extremely cheap, easily available commercially and have the advantage of working at low voltages. The use of SMA provides a very interesting alternative to the mechanisms used by conventional actuators. SMAs allow to drastically reduce the size, weight and complexity of robotic systems. In fact, their large force-weight ratio, large life cycles, negligible volume, sensing capability and noise-free operation make possible the use of this technology for building a new class of actuation devices. Nonetheless, high power consumption and low bandwidth limit this technology for certain kind of applications. This presents a challenge that must be addressed from both materials and control perspectives in order to overcome these drawbacks. Here, the latter is tackled. It has been demonstrated that suitable control strategies and proper mechanical arrangements can dramatically improve on SMA performance, mostly in terms of actuation speed and limit cycles.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A cell of the bacterium Escherichia coli was tethered covalently to a glass coverslip by a single flagellum, and its rotation was stopped by using optical tweezers. The tweezers acted directly on the cell body or indirectly, via a trapped polystyrene bead. The torque generated by the flagellar motor was determined by measuring the displacement of the laser beam on a quadrant photodiode. The coverslip was mounted on a computer-controlled piezo-electric stage that moved the tether point in a circle around the center of the trap so that the speed of rotation of the motor could be varied. The motor generated ≈4500 pN nm of torque at all angles, regardless of whether it was stalled, allowed to rotate very slowly forwards, or driven very slowly backwards. This argues against models of motor function in which rotation is tightly coupled to proton transit and back-transport of protons is severely limited.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The design, realization, and test performances of an electronic junction based on single-electron phenomena that works in the air at room temperature are hereby reported. The element consists of an electrochemically etched sharp tungsten stylus over whose tip a nanometer-size crystal was synthesized. Langmuir-Blodgett films of cadmium arachidate were transferred onto the stylus and exposed to a H2S atmosphere to yield CdS nanocrystals (30-50 angstrom in diameter) imbedded into an organic matrix. The stylus, biased with respect to a flat electrode, was brought to the tunnel distance from the film and a constant gap value was maintained by a piezo-electric actuator driven by a feedback circuit fed by the tunneling current. With this set-up, it is possible to measure the behavior of the current flowing through the quantum dot when a bias voltage is applied. Voltage-current characteristics measured in the system displayed single-electron trends such as a Coulomb blockade and Coulomb staircase and revealed capacitance values as small as 10(-19) F.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present thesis is focused on the development of a thorough mathematical modelling and computational solution framework aimed at the numerical simulation of journal and sliding bearing systems operating under a wide range of lubrication regimes (mixed, elastohydrodynamic and full film lubrication regimes) and working conditions (static, quasi-static and transient conditions). The fluid flow effects have been considered in terms of the Isothermal Generalized Equation of the Mechanics of the Viscous Thin Films (Reynolds equation), along with the massconserving p-Ø Elrod-Adams cavitation model that accordingly ensures the so-called JFO complementary boundary conditions for fluid film rupture. The variation of the lubricant rheological properties due to the viscous-pressure (Barus and Roelands equations), viscous-shear-thinning (Eyring and Carreau-Yasuda equations) and density-pressure (Dowson-Higginson equation) relationships have also been taken into account in the overall modelling. Generic models have been derived for the aforementioned bearing components in order to enable their applications in general multibody dynamic systems (MDS), and by including the effects of angular misalignments, superficial geometric defects (form/waviness deviations, EHL deformations, etc.) and axial motion. The bearing exibility (conformal EHL) has been incorporated by means of FEM model reduction (or condensation) techniques. The macroscopic in fluence of the mixedlubrication phenomena have been included into the modelling by the stochastic Patir and Cheng average ow model and the Greenwood-Williamson/Greenwood-Tripp formulations for rough contacts. Furthermore, a deterministic mixed-lubrication model with inter-asperity cavitation has also been proposed for full-scale simulations in the microscopic (roughness) level. According to the extensive mathematical modelling background established, three significant contributions have been accomplished. Firstly, a general numerical solution for the Reynolds lubrication equation with the mass-conserving p - Ø cavitation model has been developed based on the hybridtype Element-Based Finite Volume Method (EbFVM). This new solution scheme allows solving lubrication problems with complex geometries to be discretized by unstructured grids. The numerical method was validated in agreement with several example cases from the literature, and further used in numerical experiments to explore its exibility in coping with irregular meshes for reducing the number of nodes required in the solution of textured sliding bearings. Secondly, novel robust partitioned techniques, namely: Fixed Point Gauss-Seidel Method (PGMF), Point Gauss-Seidel Method with Aitken Acceleration (PGMA) and Interface Quasi-Newton Method with Inverse Jacobian from Least-Squares approximation (IQN-ILS), commonly adopted for solving uid-structure interaction problems have been introduced in the context of tribological simulations, particularly for the coupled calculation of dynamic conformal EHL contacts. The performance of such partitioned methods was evaluated according to simulations of dynamically loaded connecting-rod big-end bearings of both heavy-duty and high-speed engines. Finally, the proposed deterministic mixed-lubrication modelling was applied to investigate the in fluence of the cylinder liner wear after a 100h dynamometer engine test on the hydrodynamic pressure generation and friction of Twin-Land Oil Control Rings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Patient discomfort is one reason for poor compliance with supportive periodontal therapy (SPT). The aim of this study was to compare the levels of discomfort during SPT, using the Vector (TM) system and treatment with a conventional ultrasonic scaler. Methods: Forty-six patients with an SPT programme were debrided using both the Vector (TM) system and a conventional piezo-electric scaler (Sirona (TM)) in a split mouth design. A visual analogue scale was used to evaluate of pain scores upon completion of treatment. A verbal response scale(VRS) was used to assess discomfort, vibration and noise associated with the scaling system, as well as the volume and taste of the coolant used by these systems. Results: Patients instrumented with the Vector (TM) system experienced approximately half the amount of pain compared with the conventional ultrasonic scaling system. The VRS showed that the Vector (TM) system caused less discomfort than the conventional ultrasonic scaling system when assessed for pain, vibration, noise and volume of coolant. These findings were all statistically significant. There was, however, no statistically significant difference between the two systems when assessed for taste. Conclusion: During SPT the Vector (TM) system caused reduced discomforting sensations compared with conventional methods and may be useful in improving compliance with SPT programmes.