963 resultados para Photon asymmetry
Resumo:
Brazilian poultry production nowadays occupies important position in world's economy due to its technological advancement, which associated to the development of genetic strains of high growth may cause deviation in the growth rate and harm production. Morphological asymmetry has been pointed as an indicator of welfare, as maintained the pattern that leads to balance, the broiler chicken would have its normal locomotion characteristics, freely reaching water and feed. Thus, the objective of this research was to verify the possibility of using morphological asymmetry for evaluating walking ability of broiler chicken. The research was done in the Technology Center, at UNICAMP. The experiment was made using biomechanics analysis and following, the toes were measured. Results found did not show asymmetry useful for determining the locomotion ability of broiler chicken. New studies are recommended in order to search for other correlations that might help to estimate at field level, the locomotion difficulties of broiler chicken.
Resumo:
In this work we report the observation of the blue visible fluorescence at 420 nm in rubidium vapour as a result of two-photon absorption excited by femtosecond laser pulses 790 nm. After experimental investigation of the spa-tial and spectral characteristics of the obtained emission we can claim that mechanism of this coherent fluorescence at 420 nm was not caused by ampli-fied spontaneous emission, but represents the nondegenerate four-wave mixing. As a probable outcome of this investigation an opportunity of creation an ultrafast all-optical switcher might appear.
Resumo:
Control of the world-wide spread of methicillin-resistant Staphylococcus aureus (MRSA) has been unsuccessful in most developed countries. A few countries have been able to maintain a low MRSA prevalence, plausibly due to their strict MRSA control policies. Such policies require wide-scale screening of patients with suspected MRSA colonization, in order to nurse the MRSA-positive patients in contact isolation. The aim of this study was to develop and introduce a 2-photon excited fluorescence detection (TPX) technique for screening of MRSA directly from clinical samples. The assay principle involves specific online immunometric monitoring of S. aureus growth under selective antibiotic pressure. After the novel TPX approach had been set up, its applicability for the detection of MRSA was evaluated using a large MRSA collection including practically all epidemic MRSA strains identified in Finland between 1991 and 2009. The TPX assay was found both sensitive (97.9%) and specific (94.1%) in this epidemiological setting, illustrating that the method is tolerant to wide biological variation as well as to environments with rapidly emerging MRSA strains. When MRSA was screened directly from colonization samples, all patients positive for MRSA by conventional methods were positive also by the TPX assay. The assay capacity was 48 samples per a test run, and the median time required for confirmation of a true-positive screening test result was 3 h 26 min. Collectively, the findings presented in this thesis suggest that the TPX MRSA screening assay could be applicable for direct screening of MRSA colonization samples without any prior steps of isolation. This can potentially mean that contact isolation of suspected carriers testing negative could be discontinued earlier, thereby reducing the costs and burden associated with the containment of MRSA. In case of infection, a positive test result would ensure an early onset of effective therapy.
Resumo:
The objective of the present study was to identify the single photon emission computed tomography (SPECT) and magnetic resonance (MR) findings in juvenile systemic lupus erythematosus (JSLE) patients with CNS involvement and to try to correlate them with neurological clinical history data and neurological clinical examination. Nineteen patients with JSLE (16 girls and 3 boys, mean age at onset 9.2 years) were submitted to neurological examination, electroencephalography, cerebrospinal fluid analysis, SPECT and MR. All the evaluations were made separately within a period of 15 days. SPECT and MR findings were analyzed independently by two radiologists. Electroencephalography and cerebrospinal fluid analysis revealed no relevant alterations. Ten of 19 patients (53%) presented neurological abnormalities including present or past neurological clinical history (8/19, 42%), abnormal neurological clinical examination (5/19, 26%), and abnormal SPECT or MR (8/19, 42% and 3/19, 16%, respectively). The most common changes in SPECT were cerebral hypoperfusion and heterogeneous distribution of blood flow. The most common abnormalities in MR were leukomalacia and diffuse alterations of white matter. There was a correlation between SPECT and MR (P<0.05). We conclude that SPECT and MR are complementary and useful exams in the evaluation of neurological involvement of lupus.
Resumo:
The effect of physical exercise on the treatment of depressive elderly adults has not been investigated thus far in terms of changes in cortical hemispheric activity. The objective of the present study was to identify changes in depressive symptoms, quality of life, and cortical asymmetry produced by aerobic activity. Elderly subjects with a diagnosis of major depressive disorder (DSM-IV) were included. Twenty patients (70% females, 71 ± 3 years) were divided into an exercise group (pharmacological treatment plus aerobic training) and a control group (undergoing pharmacological treatment) in a quasi-experimental design. Pharmacological treatment was maintained stable throughout the study (antidepressants and anxiolytics). Subjects were evaluated by depression scales (Beck Depression Inventory, Hamilton Depression Rating Scale, Montgomery-Asberg Depression Rating Scale) and the Short Form Health Survey-36, and electroencephalographic measurements (frontal and parietal alpha asymmetry) before and after 1 year of treatment. After 1 year, the control group showed a decrease in cortical activity on the right hemisphere (increase of alpha power), which was not observed in the exercise group. The exercise group showed a significant decrease of depressive symptoms, which was not observed in the control group. This result was also accompanied by improved treatment response and remission rate after 1 year of aerobic exercise associated with treatment. This study provides support for the effect of aerobic training on alpha activity and on depressive symptoms in elderly patients. Exercise facilitates the treatment of depressive elderly adults, leading to clinical and physical improvement and protecting against a decrease in cortical activity.
Resumo:
We recently demonstrated that automatic attention favors the right side of space and, in the present study, we investigated whether voluntary attention also favors this side. Six reaction time experiments were conducted. In each experiment, 12 new 18-25-year-old male right-handed individuals were tested. In Experiments 1, 2, 3 (a, b) and 4 (a, b), tasks with increasing attentional demands were used. In Experiments 1, 2, 3a, and 4a, attention was oriented to one or both sides by means of a central spatially informative visual cue. A left or right side visual target appeared 100, 300, or 500 ms later. Attentional effects were observed in the four experiments. In Experiments 2, 3a and 4a, these effects were greater when the cue indicated the right side than when it indicated the left side (respectively: 16 ± 10 and 44 ± 6 ms, P = 0.015, for stimulus onset asynchrony of 500 ms in Experiment 2; 38 ± 10 and 70 ± 7 ms, P = 0.011, for Experiment 3a, and 23 ± 11 and 61 ± 10 ms, P = 0.009, for Experiment 4a). In Experiments 3b and 4b, the central cue pointed to both sides and was said to be non-relevant for task performance. In these experiments right and left reaction times did not differ. The most conservative interpretation of the present findings is that voluntary attention orienting favors the right side of space, particularly when a difficult task has to be performed.
Resumo:
The single photon emission microscope (SPEM) is an instrument developed to obtain high spatial resolution single photon emission computed tomography (SPECT) images of small structures inside the mouse brain. SPEM consists of two independent imaging devices, which combine a multipinhole collimator, a high-resolution, thallium-doped cesium iodide [CsI(Tl)] columnar scintillator, a demagnifying/intensifier tube, and an electron-multiplying charge-coupling device (CCD). Collimators have 300- and 450-µm diameter pinholes on tungsten slabs, in hexagonal arrays of 19 and 7 holes. Projection data are acquired in a photon-counting strategy, where CCD frames are stored at 50 frames per second, with a radius of rotation of 35 mm and magnification factor of one. The image reconstruction software tool is based on the maximum likelihood algorithm. Our aim was to evaluate the spatial resolution and sensitivity attainable with the seven-pinhole imaging device, together with the linearity for quantification on the tomographic images, and to test the instrument in obtaining tomographic images of different mouse organs. A spatial resolution better than 500 µm and a sensitivity of 21.6 counts·s-1·MBq-1 were reached, as well as a correlation coefficient between activity and intensity better than 0.99, when imaging 99mTc sources. Images of the thyroid, heart, lungs, and bones of mice were registered using 99mTc-labeled radiopharmaceuticals in times appropriate for routine preclinical experimentation of <1 h per projection data set. Detailed experimental protocols and images of the aforementioned organs are shown. We plan to extend the instrument's field of view to fix larger animals and to combine data from both detectors to reduce the acquisition time or applied activity.
Resumo:
Upconversion photoluminescence is a unique property of mostly certain inorganic materials, which are capable of converting low-energy infrared radiation into a higher-energy emission at visible wavelengths. This anti-Stokes shift enables luminescence detection without autofluorescence, which makes the upconverting materials a highly suitable reporter technology for optical biosensing applications. Furthermore, they exhibit long luminescence lifetime with narrow bandwidths also at the optical window of biomaterials enabling luminescence measurements in challenging sample matrices, such as whole blood. The aim of this thesis was to study the unique properties and the applicability of nano-sized upconverting phosphors (UCNPs) as reporters in biosensing applications. To render the inorganic nanophosphors water-dispersible and biocompatible, they were subjected to a series of surface modifications starting with silica-encapsulation and ending with a bioconjugation step with an analyte-recognizing biomolecule. The paramagnetism of the lanthanide dopants in the nanophosphors was exploited to develop a highly selective separation method for the UCNP-bioconjugates based on the magnetic selectivity of the high gradient magnetic separation (HGMS) system. The applicability of the nano-sized UCNPs as reporters in challenging sample matrices was demonstrated in two homogeneous sensing applications based on upconversion resonance energy transfer (UC-RET). A chemosensor for intracellular pH was developed exploiting UC-RET between the UCNP and a fluorogenic pH-sensitive dye with strongly increasing fluorescence intensity in decreasing pH. The pH-independent emission of the UCNPs at 550 nm was used for referencing. The applicability of the pH-nanosensor for intracellular pH measurement was tested in HeLa cells, and the acidic pH of endosomes could be detected with a confocal fluorescence microscope. Furthermore, a competitive UC-RET-based assay for red blood cell folic acid was developed for the measurement of folate directly from a whole blood sample. The optically transparent window of biomaterials was used in both the excitation and the measurement of the UC-RET sensitized emission of a near-infrared acceptor dye to minimize sample absorption, and the anti-Stokes detection completely eliminated the Stokes-shifted autofluorescence. The upconversion photoluminescence efficiency is known to be dependent on crystallite size, because the increasing surface-to-volume ratio of nano-sized UCNPs renders them more susceptible to quenching effects of the environment than their bulk counterpart. Water is known to efficiently quench the luminescence of lanthanide dopants. In this thesis, the quenching mechanism of water was studied using luminescence decay measurements. Water was found to quench the luminescence of UCNPs by increasing the non-radiative relaxation of the excited state of Yb3+ sensitizer ion, which had a very strong quenching effect on upconversion luminescence intensity.
Resumo:
Confocal and two-photon microcopy have become essential tools in biological research and today many investigations are not possible without their help. The valuable advantage that these two techniques offer is the ability of optical sectioning. Optical sectioning makes it possible to obtain 3D visuahzation of the structiu-es, and hence, valuable information of the structural relationships, the geometrical, and the morphological aspects of the specimen. The achievable lateral and axial resolutions by confocal and two-photon microscopy, similar to other optical imaging systems, are both defined by the diffraction theorem. Any aberration and imperfection present during the imaging results in broadening of the calculated theoretical resolution, blurring, geometrical distortions in the acquired images that interfere with the analysis of the structures, and lower the collected fluorescence from the specimen. The aberrations may have different causes and they can be classified by their sources such as specimen-induced aberrations, optics-induced aberrations, illumination aberrations, and misalignment aberrations. This thesis presents an investigation and study of image enhancement. The goal of this thesis was approached in two different directions. Initially, we investigated the sources of the imperfections. We propose methods to eliminate or minimize aberrations introduced during the image acquisition by optimizing the acquisition conditions. The impact on the resolution as a result of using a coverslip the thickness of which is mismatched with the one that the objective lens is designed for was shown and a novel technique was introduced in order to define the proper value on the correction collar of the lens. The amoimt of spherical aberration with regard to t he numerical aperture of the objective lens was investigated and it was shown that, based on the purpose of our imaging tasks, different numerical apertures must be used. The deformed beam cross section of the single-photon excitation source was corrected and the enhancement of the resolution and image quaUty was shown. Furthermore, the dependency of the scattered light on the excitation wavelength was shown empirically. In the second part, we continued the study of the image enhancement process by deconvolution techniques. Although deconvolution algorithms are used widely to improve the quality of the images, how well a deconvolution algorithm responds highly depends on the point spread function (PSF) of the imaging system applied to the algorithm and the level of its accuracy. We investigated approaches that can be done in order to obtain more precise PSF. Novel methods to improve the pattern of the PSF and reduce the noise are proposed. Furthermore, multiple soiu'ces to extract the PSFs of the imaging system are introduced and the empirical deconvolution results by using each of these PSFs are compared together. The results confirm that a greater improvement attained by applying the in situ PSF during the deconvolution process.
Resumo:
A method using L-cysteine for the determination of arsenous acid (As(III)), arsenic acid (As(V)), monomethylarsonic acid (MMAA), and dimethylarsinic acid (DMAA) by hydride generation was demonstrated. The instrument used was a d.c. plasma atomic emission spectrometer (OCP-AES). Complete recovery was reported for As(III), As(V), and DMAA while 86% recovery was reported for MMAA. Detection limits were determined, as arsenic for the species listed previously, to be 1.2, 0.8, 1.1, and 1.0 ngemL-l, respectively. Precision values, at 50 ngemL-1 arsenic concentration, were f.80/0, 2.50/0, 2.6% and 2.6% relative standard deviation, respectively. The L-cysteine reagent was compared directly with the conventional hydride generation technique which uses a potassium iodide-hydrochloric acid medium. Recoveries using L-cysteine when compared with the conventional method provided the following results: similar recoveries were obtained for As(III), slightly better recoveries were obtained for As(V) and MMAA, and significantly better recoveries for DMAA. In addition, tall and sharp peak shapes were observed for all four species when using L-cysteine. The arsenic speciation method involved separation by ion exchange .. high perfonnance liquid chromatography (HPLC) with on-line hydride generation using the L.. cysteine reagent and measurement byOCP-AES. Total analysis time per sample was 12 min while the time between the start of subsequent runs was approximately 20 min. A binary . gradient elution program, which incorporated the following two eluents: 0.01 and 0.5 mM tri.. sodium citrate both containing 5% methanol (v/v) and both at a pH of approximately 9, was used during the separation by HPLC. Recoveries of the four species which were measured as peak area, and were normalized against As(III), were 880/0, 290/0, and 40% for DMAA, MMAA and As(V), respectively. Resolution factors between adjacent analyte peaks of As(III) and DMAA was 1.1; DMAA and MMAA was 1.3; and MMAA and As(V) was 8.6. During the arsenic speciation study, signals from the d.c. plasma optical system were measured using a new photon-signal integrating device. The_new photon integrator developed and built in this laboratory was based on a previously published design which was further modified to reflect current available hardware. This photon integrator was interfaced to a personal computer through an AID convertor. The .photon integrator has adjustable threshold settings and an adjustable post-gain device.
Resumo:
LaFond and Watts (2008) provide evidence that information asymmetry might be a determinant of accounting conservatism. One implication of their paper is that regulators trying to reduce information asymmetry by lowering the level of accounting conservatism might be wrong. However, there is a trend in moving away from conservative accounting. The typical example is IFRS adoption. Therefore, this paper studies information asymmetry and accounting conservatism under IFRS adoption. The results show that the level of accounting conservatism decreases after mandatory IFRS adoption, but the adoption of IFRS is likely to weaken the relationship between information asymmetry and accounting conservatism. Moreover, this paper investigates how the change of accounting conservatism under IFRS is related to the change in information environment. The finding shows that accounting conservatism increases information environment, supporting the idea that, by providing comparatively credible information, conservative accounting is beneficial to the information environment.
Asymmetry Risk, State Variables and Stochastic Discount Factor Specification in Asset Pricing Models
Resumo:
In this paper, I present a non standard objection to moral impartialism. My idea is that moral impartialism is questionable when it is committed to a principle we have reasons to reject: the principle of self-other symmetry. According to the utilitarian version of the principle, the benefits and harms to the agent are exactly as relevant to the global evaluation of the goodness of his action as the benefits and harms to any other agent. But this view sits badly with the “Harm principle” which stresses the difference between harm to others and harm to the self. According to the deontological version, we have moral duties to ourselves which are exactly symmetrical to our duties to others. But there are reasons to believe that the idea of a duty to the self is not coherent.
Resumo:
Cette thèse constitue à la fois un apport de nature clinique et technologique dans l’approche diagnostique du glaucome. Plus précisément, nous nous proposons d’étudier une nouvelle façon de détecter le glaucome par la mesure de l’asymétrie du rapport de la surface de l’anneau neurorétinien et de la surface de la papille ou du disque optique ou rim to disc area asymmetry ratio (RADAAR). Pour atteindre cet objectif, nous avons recours à une base de données composée d’une population subdivisée en 4 différents groupes de diagnostic (normal, glaucome possible, glaucome probable et glaucome définitif). Les mesures du RADAAR sont calculées de différentes façons à partir des paramètres stéréométriques de la tête du nerf optique des sujets, produits par la microscopie confocale à balayage laser (Heidelberg Retina Tomograph (HRT) (Heidelberg Engineering, Germany)). Nous procédons à une analyse de données grâce au logiciel SPSS où nous mettons en exergue la distribution du RADAAR dans les différentes populations, sa validité et son utilité dans le dépistage du glaucome. Nous enrôlons donc 523 sujets dans cette étude avec 82 sujets atteints de glaucome définitif. La moyenne d’âge est de 62 ans. Il y a plus de femmes que d’hommes et plus de Caucasiens que d’Africains Caribéens. Nous trouvons que la distribution de la mesure du RADAAR est différente des sujets d’un groupe de diagnostic à l’autre. En termes de performance, la sensibilité de la mesure du RADAAR est très basse c'est-à-dire que sa capacité de détecter la maladie est basse. En revanche la mesure du RADAAR est plus spécifique c'est-à-dire que sa capacité d’identifier les sujets exempts de la maladie est plus grande. Elle tendrait à être aussi plus performante chez les Africains Caribéens que chez les Caucasiens. De même, elle serait plus sensible chez les hommes que chez les femmes. La mesure du RADAAR est utile si on l’associe à une autre méthode de diagnostic comme l’analyse de Régression de Moorfields (MRA) incluse dans le logiciel du HRT3 spécialement lors de la détection du glaucome dans la population à haut risque. En définitive, nous déterminons que la mesure du RADAAR se veut un outil d’aide au diagnostic. Elle est particulièrement intéressante dans le contexte de dépistage de glaucome.