944 resultados para Pertecnetato de tecnécio Tc 99m
Resumo:
Several clinic evaluations have been possible with radiobiocomplexes labeled with technetium-99m (99mTc). Some natural and synthetic drugs are capable of to interfere on the labeling of blood constituents with 99mTc, as well as on the biodistribution of radiobiocomplexes. Authors have also reported about the toxicity of several natural products. The aim of this study was to compare the effects of the Mentha crispa (hortelã) and of the Hypericum perforatum (hipérico) in different experimental models. On the labeling of red blood cells (RBC) and plasma and cellular proteins with 99mTc, both extracts were capable of to decrease the radioactivity percentage on the cellular compartment and on the fixation on plasma and cellular proteins. On the morphometry of the RBC, only the hortelã was capable to alter the shape and the perimeter/area ratio of the RBC. On the biodistribution of the radiobiocomplex sodium pertechnetate (Na99mTcO4), the hortelã increased the Na99mTcO4 distribution in the kidney, spleen, liver and thyroid, meanwhile the hipérico decreased the Na99mTcO4 distribution in the bone, stomach, lungs and thyroid, and increased the Na99mTcO4 distribution in the pancreas. On the bacterial cultures survival, the hipérico was capable of to protect the bacteria against the stannous chloride (SnCl2) effect. The hipérico did not alter the topology of plasmidial DNA and did not protect the plasmidial DNA against the SnCl2 action. Probably, the effects presented by both extracts could be due to chemical compounds of the extracts that could alter the morphology of the RBC and the plasma membrane ions transport, and/or by phytocomplexes that could be formed with different effects dependent on the biological system considered
Resumo:
Medicinal plants have been studied and used in the world. Lantana camara has medicinal properties and it has been used in folk medicine. The aim was to verify the effect of a lantana extract on the labeling of blood constituents with 99mTc, and to evaluate the effect of an aqueous extract of Lantana camara on the morphology of RBC withdrawn from Wistar rats. The results showed that lantana extract has decreased the fixation of radioactivity on the IF-P. This effect was not observed in the BC compartment and in IF-BC. The BC-%ATI was decreased in all concentrations tested when the BC was washed. The osmotic fragility assay and morphological analysis were carried out. In presence of the extract, the data obtained indicated that (i) an increase of the hemolysis and (ii) modifications on the morphology of RBC. These effects of the Lantana camara could be associated with some pharmacological properties of the chemical compounds of this studied extract
Resumo:
The biliopancretic diversion with duodenal switch is one of the mixing techniques used in the treatment of morbid obesity. The duodenal switch reduces the stomach capacity and leaves only 50-100 cm of small intestine for nutrition and absorption. The surgery produces hormonal, structural and biochemical changes, which can influence on the result of scintigraphic examinations in operated patients. With the objective of evaluate the postoperative biodistribution of sodium pertechnetate (Na99mTcO4) in brain, thyroid, heart, lung, liver, spleen, kidney, stomach, duodenum, pancreas, small intestine, bladder, muscle and bone of Wistar rats. The rats were randomly allocated into 3 groups of 7 rats each: the duodenal switch group (DS), the control group (C) and the sham group (S). They were operated under anesthesia and aseptic technique. In the tenth postoperative day, 0.1mL of sodium pertechnetate was injected via orbital plexus. After 30 min the animals were killed with overdose of anesthetic and samples of liver, spleen, pancreas, stomach, duodenum, small intestine, thyroid, lung, heart, kidney, bladder, muscle, bone and brain were harvested, washed with saline and weighed. The detention of radioactivity was made using the automatic Gamma Counter Wizard, PerkinElmer and the percentage of activity per gram of tissue (%ATI/g) was calculated. There was no early or late mortality in either rats groups. The values of percent radioactivity per gram of tissue (%ATI/g), showed no significant difference in liver, stomach, small bowel, duodenum, kidney, heart, bladder, bone and brain, when compared the DS rats with sham and controls rats. A postoperative significant increase in mean %ATI/g levels was observed in spleen, pancreas and muscle in group DS rats, as compared to group S and C rats (p<0.05). In the lung there was an increase and in thyroid a decrease in mean %ATI/g of DS rats, when compared to sham rats (p>0.05). In conclusion, the biliopancreatic diversion with duodenal switch in rats modified the biodistribution of sodium pertechnetate in thyroid, lung, pancreas, spleen and muscle. The study had the participation of the departments and laboratories researches, as Nucleus of Experimental Surgery, Department of Surgery, Laboratory of Radiobiology, Department of Pathology and Service of Nuclear Medicine, certifying the character of a multidisciplinary research
Resumo:
Owing to its optimal nuclear properties, ready availability, low cost and favourable dosimetry, (99m)Tc continues to be the ideal radioisotope for medical-imaging applications. Bifunctional chelators based on a tetraamine framework exhibit facile complexation with Tc(V)O(2) to form monocationic species with high in vivo stability and significant hydrophilicity, which leads to favourable pharmacokinetics. The synthesis of a series of 1,4,8,11-tetraazaundecane derivatives (01-06) containing different functional groups at the 6-position for the conjugation of biomolecules and subsequent labelling with (99m)Tc is described herein. The chelator 01 was used as a starting material for the facile synthesis of chelators functionalised with OH (02), N(3) (04) and O-succinyl ester (05) groups. A straightforward and easy synthesis of carboxyl-functionalised tetraamine-based chelator 06 was achieved by using inexpensive and commercially available starting materials. Conjugation of 06 to a potent bombesin-antagonist peptide and subsequent labelling with (99m)Tc afforded the radiotracer (99m)Tc-N4-BB-ANT, with radiolabelling yields of >97% at a specific activity of 37 GBq micromol(-1). An IC(50) value of (3.7+/-1.3) nM was obtained, which confirmed the high affinity of the conjugate to the gastrin-releasing-peptide receptor (GRPr). Immunofluorescence and calcium mobilisation assays confirmed the strong antagonist properties of the conjugate. In vivo pharmacokinetic studies of (99m)Tc-N4-BB-ANT showed high and specific uptake in PC3 xenografts and in other GRPr-positive organs. The tumour uptake was (22.5+/-2.6)% injected activity per gram (% IA g(-1)) at 1 h post injection (p.i.). and increased to (29.9+/-4.0)% IA g(-1) at 4 h p.i. The SPECT/computed tomography (CT) images showed high tumour uptake, clear background and negligible radioactivity in the abdomen. The promising preclinical results of (99m)Tc-N4-BB-ANT warrant its potential candidature for clinical translation.
Resumo:
Study with the purpose to examine the effects of duodenal switch (DS), regularly performed in morbidly obese patients, on biodistribution of sodium pertechnetate in several organs of rats. There was no early or late mortality in either rats groups. The values of percent radioactivity per gram of tissue (%ATI/g), showed no significant difference in liver, stomach, small bowel, duodenum, kidney, heart, bladder, bone and brain, when compared the DS rats with sham and controls rats. A postoperative significant increase (p<0.05) in mean %ATI/g levels was observed in spleen, pancreas and muscle in group DS rats, as compared to group S and C rats. In the lung there was an increase and in thyroid a decrease in mean %ATI/g of DS rats, when compared to sham rats (p<0.05). In conclusion, the biliopancreatic diversion with duodenal switch in rats modified the biodistribution of sodium pertechnetate in thyroid, lung, pancreas, spleen and muscle
Resumo:
Study with the purpose to examine the effects of duodenal switch (DS), regularly performed in morbidly obese patients, on biodistribution of sodium pertechnetate in several organs of rats. There was no early or late mortality in either rats groups. The values of percent radioactivity per gram of tissue (%ATI/g), showed no significant difference in liver, stomach, small bowel, duodenum, kidney, heart, bladder, bone and brain, when compared the DS rats with sham and controls rats. A postoperative significant increase (p<0.05) in mean %ATI/g levels was observed in spleen, pancreas and muscle in group DS rats, as compared to group S and C rats. In the lung there was an increase and in thyroid a decrease in mean %ATI/g of DS rats, when compared to sham rats (p<0.05). In conclusion, the biliopancreatic diversion with duodenal switch in rats modified the biodistribution of sodium pertechnetate in thyroid, lung, pancreas, spleen and muscle
Resumo:
The objectives of the study were to evaluate the performance of sentinel lymph node biopsy (SLNB) in detecting occult metastases in papillary thyroid carcinoma (PTC) and to correlate their presence to tumor and patient characteristics. Twenty-three clinically node-negative PTC patients (21 females, mean age 48.4 years) were prospectively enrolled. Patients were submitted to sentinel lymph node (SLN) lymphoscintigraphy prior to total thyroidectomy. Ultrasound-guided peritumoral injections of (99m)Tc-phytate (7.4 MBq) were performed. Cervical single-photon emission computed tomography and computed tomography (SPECT/CT) images were acquired 15 min after radiotracer injection and 2 h prior to surgery. Intra-operatively, SLNs were located with a gamma probe and removed along with non-SLNs located in the same neck compartment. Papillary thyroid carcinoma, SLNs and non-SLNs were submitted to histopathology analysis. Sentinel lymph nodes were located in levels: II in 34.7 % of patients; III in 26 %; IV in 30.4 %; V in 4.3 %; VI in 82.6 % and VII in 4.3 %. Metastases in the SLN were noted in seven patients (30.4 %), in non-SLN in three patients (13.1 %), and in the lateral compartments in 20 % of patients. There were significant associations between lymph node (LN) metastases and the presence of angio-lymphatic invasion (p = 0.04), extra-thyroid extension (p = 0.03) and tumor size (p = 0.003). No correlations were noted among LN metastases and patient age, gender, stimulated thyroglobulin levels, positive surgical margins, aggressive histology and multifocal lesions. Sentinel lymph node biopsy can detect occult metastases in PTC. The risk of a metastatic SLN was associated with extra-thyroid extension, larger tumors and angio-lymphatic invasion. This may help guide future neck dissection, patient surveillance and radioiodine therapy doses.
Resumo:
OBJETIVO: Avaliar as características demográficas e de imagens da trombose endoluminal em uma série de pacientes submetidos a tratamento endovascular do aneurisma de aorta abdominal (TEAAA). MÉTODOS: Avaliamos as características de imagem que permitiram o diagnóstico da trombose endoluminal em uma série de 30 pacientes submetidos ao TEAAA, com seguimento de 5 a 29 meses, através de exames de tomografia computadorizada multidetectores (TCMD) de 64 canais. RESULTADOS: Foram diagnosticados dez casos de trombose luminal (33,3%), sendo que em três pacientes a trombose foi total de um ramo ilíaco. CONCLUSÃO: A TCMD permitiu o diagnóstico de diferentes tipos de trombose endoluminal em pacientes submetidos ao TEAAA. O uso desta modalidade diagnóstica minimamente invasiva deverá ser encorajado na prática clínica.
Resumo:
Background. The radioguided localization of occult breast lesions (ROLL) technique often utilizes iodinated radiographic contrast to assure that the local injection of (99m)Tc-MAA corresponds to the location of the lesion under investigation. However, for this application, this contrast has several shortcomings. The objective of this study was to evaluate the safety, effectiveness and technical feasibility of the use of polydimethylsiloxane (PDMS) as radiological contrast and tissue marker in ROLL. Materials and methods. The safety assessment was performed by the acute toxicity study in Wistar rats (n = 50). The radiological analysis of breast tissue (n = 32) from patients undergoing reductive mammoplasty was used to verify the effectiveness of PDMS as contrast media. The technical feasibility was evaluated through the scintigraphic and histologic analysis. Results. We found no toxic effects of PDMS for this use during the observational period. It has been demonstrated in human breast tissue that the average diameter of the tissue marked by PDMS was lower than when marked by the contrast medium (p <0.001). PDMS did not interfere with the scintigraphic uptake (p = 0.528) and there was no injury in histological processing of samples. Conclusions. This study demonstrated not only the superiority of PDMS as radiological contrast in relation to the iodinated contrast, but also the technical feasibility for the same applicability in the ROLL.
Resumo:
Background: Cardiac cell transplantation is compromised by low cell retention and poor graft viability. Here, the effects of co-injecting adipose tissue-derived stem cells (ASCs) with biopolymers on cell cardiac retention, ventricular morphometry and performance were evaluated in a rat model of myocardial infarction (MI). Methodology/Principal Findings: (99m)Tc-labeled ASCs (1 x 10(6) cells) isolated from isogenic Lewis rats were injected 24 hours post-MI using fibrin a, collagen (ASC/C), or culture medium (ASC/M) as vehicle, and cell body distribution was assessed 24 hours later by gamma-emission counting of harvested organs. ASC/F and ASC/C groups retained significantly more cells in the myocardium than ASC/M (13.8+/-2.0 and 26.8+/-2.4% vs. 4.8+/-0.7%, respectively). Then, morphometric and direct cardiac functional parameters were evaluated 4 weeks post-MI cell injection. Left ventricle (LV) perimeter and percentage of interstitial collagen in the spare myocardium were significantly attenuated in all ASC-treated groups compared to the non-treated (NT) and control groups (culture medium, fibrin, or collagen alone). Direct hemodynamic assessment under pharmacological stress showed that stroke volume (SV) and left ventricle end-diastolic pressure were preserved in ASC-treated groups regardless of the vehicle used to deliver ASCs. Stroke work (SW), a global index of cardiac function, improved in ASC/M while it normalized when biopolymers were co-injected with ASCs. A positive correlation was observed between cardiac ASCs retention and preservation of SV and improvement in SW post-MI under hemodynamic stress. Conclusions: We provided direct evidence that intramyocardial injection of ASCs mitigates the negative cardiac remodeling and preserves ventricular function post-MI in rats and these beneficial effects can be further enhanced by administrating co-injection of ASCs with biopolymers.
Resumo:
Background: Cell therapy approaches for biologic cardiac repair hold great promises, although basic fundamental issues remain poorly understood. In the present study we examined the effects of timing and routes of administration of bone marrow cells (BMC) post-myocardial infarction (MI) and the efficacy of an injectable biopolymer scaffold to improve cardiac cell retention and function. Methodology/Principal Findings: (99m)Tc-labeled BMC (6x10(6) cells) were injected by 4 different routes in adult rats: intravenous (IV), left ventricular cavity (LV), left ventricular cavity with temporal aorta occlusion (LV(+)) to mimic coronary injection, and intramyocardial (IM). The injections were performed 1, 2, 3, or 7 days post-MI and cell retention was estimated by gamma-emission counting of the organs excised 24 hs after cell injection. IM injection improved cell retention and attenuated cardiac dysfunction, whereas IV, LV or LV* routes were somewhat inefficient (< 1%). Cardiac BMC retention was not influenced by timing except for the IM injection that showed greater cell retention at 7 (16%) vs. 1, 2 or 3 (average of 7%) days post-MI. Cardiac cell retention was further improved by an injectable fibrin scaffold at day 3 post-MI (17 vs. 7%), even though morphometric and function parameters evaluated 4 weeks later displayed similar improvements. Conclusions/Significance: These results show that cells injected post-MI display comparable tissue distribution profile regardless of the route of injection and that there is no time effect for cardiac cell accumulation for injections performed 1 to 3 days post-MI. As expected the IM injection is the most efficient for cardiac cell retention, it can be further improved by co-injection with a fibrin scaffold and it significantly attenuates cardiac dysfunction evaluated 4 weeks post myocardial infarction. These pharmacokinetic data obtained under similar experimental conditions are essential for further development of these novel approaches.
Resumo:
Souza MA, Souza MH, Palheta RC Jr, Cruz PR, Medeiros BA, Rola FH, Magalhaes PJ, Troncon LE, Santos AA. Evaluation of gastrointestinal motility in awake rats: a learning exercise for undergraduate biomedical students. Adv Physiol Educ 33: 343-348, 2009; doi: 10.1152/advan.90176.2008.-Current medical curricula devote scarce time for practical activities on digestive physiology, despite frequent misconceptions about dyspepsia and dysmotility phenomena. Thus, we designed a hands-on activity followed by a small-group discussion on gut motility. Male awake rats were randomly submitted to insulin, control, or hypertonic protocols. Insulin and control rats were gavage fed with 5% glucose solution, whereas hypertonic-fed rats were gavage fed with 50% glucose solution. Insulin treatment was performed 30 min before a meal. All meals (1.5 ml) contained an equal mass of phenol red dye. After 10, 15, or 20 min of meal gavage, rats were euthanized. Each subset consisted of six to eight rats. Dye recovery in the stomach and proximal, middle, and distal small intestine was measured by spectrophotometry, a safe and reliable method that can be performed by minimally trained students. In a separate group of rats, we used the same protocols except that the test meal contained (99m)Tc as a marker. Compared with control, the hypertonic meal delayed gastric emptying and gastrointestinal transit, whereas insulinic hypoglycemia accelerated them. The session helped engage our undergraduate students in observing and analyzing gut motor behavior. In conclusion, the fractional dye retention test can be used as a teaching tool to strengthen the understanding of basic physiopathological features of gastrointestinal motility.
Resumo:
AIM: To evaluate the effects of meal size and three segmentations on intragastric distribution of the meal and gastric motility, by scintigraphy. METHODS: Twelve healthy volunteers were randomly assessed, twice, by scintigraphy. The test meal consisted of 60 or 180 mL of yogurt labeled with 64 MBq (99m)Tc-tin colloid. Anterior and posterior dynamic frames were simultaneously acquired for 18 min and all data were analyzed in MatLab. Three proximal-distal segmentations using regions of interest were adopted for both meals. RESULTS: Intragastric distribution of the meal between the proximal and distal compartments was strongly influenced by the way in which the stomach was divided, showing greater proximal retention after the 180 mL. An important finding was that both dominant frequencies (1 and 3 cpm) were simultaneously recorded in the proximal and distal stomach; however, the power ratio of those dominant frequencies varied in agreement with the segmentation adopted and was independent of the meal size. CONCLUSION: It was possible to simultaneously evaluate the static intragastric distribution and phasic contractility from the same recording using our scintigraphic approach. (C) 2010 Baishideng. All rights reserved.
Resumo:
Background: Primary hyperparathyroidism occurs in only 10%-30% of patients with multiple endocrine neoplasia type 2A (MEN2A), rarely as the sole clinical manifestation, and is usually diagnosed after the third decade of life. Summary: A5-year-old girl was referred for prophylactic thyroidectomy as she carried the p.C634R RET mutation. She was clinically asymptomatic, with a normally palpable thyroid and with the cervical region free of lymphadenopathy or other nodules. Preoperative tests revealed hypercalcemia associated with elevation of parathyroid hormone (PTH) (calcium = 11.2mg/dL, calcium ion = 1.48mmol/L, phosphorus = 4.0 mg/dL, alkaline phosphatase = 625U/L, parathyroid hormone (PTH) PTH = 998 pg/mL). A thyroid ultrasound was normal and parathyroid scintigraphy with (99m)Tc-Sestamibi revealed an area of radioconcentration in the upper half of the left thyroid lobe suggesting hyperfunctioning parathyroid tissue. She underwent total thyroidectomy and parathyroidectomy and developed hypocalcemia. The anatomopathological examination showed no histopathological changes in the thyroid tissue and an adenoma of the parathyroid gland, confirming the diagnosis of hyperparathyroidism. Conclusions: Primary hyperparathyroidism can be a precocious manifestation of MEN2A. This case report highlights that asymptomatic hypercalcemia should be scrutinized in children related to patients with MEN2A who carry a mutation in the RET proto-oncogene, especially mutations in the codon 634, before the currently recommended age of 8 years.
Resumo:
Radiation dose calculations in nuclear medicine depend on quantification of activity via planar and/or tomographic imaging methods. However, both methods have inherent limitations, and the accuracy of activity estimates varies with object size, background levels, and other variables. The goal of this study was to evaluate the limitations of quantitative imaging with planar and single photon emission computed tomography (SPECT) approaches, with a focus on activity quantification for use in calculating absorbed dose estimates for normal organs and tumors. To do this we studied a series of phantoms of varying complexity of geometry, with three radionuclides whose decay schemes varied from simple to complex. Four aqueous concentrations of (99m)Tc, (131)I, and (111)In (74, 185, 370, and 740 kBq mL(-1)) were placed in spheres of four different sizes in a water-filled phantom, with three different levels of activity in the surrounding water. Planar and SPECT images of the phantoms were obtained on a modern SPECT/computed tomography (CT) system. These radionuclides and concentration/background studies were repeated using a cardiac phantom and a modified torso phantom with liver and ""tumor"" regions containing the radionuclide concentrations and with the same varying background levels. Planar quantification was performed using the geometric mean approach, with attenuation correction (AC), and with and without scatter corrections (SC and NSC). SPECT images were reconstructed using attenuation maps (AM) for AC; scatter windows were used to perform SC during image reconstruction. For spherical sources with corrected data, good accuracy was observed (generally within +/- 10% of known values) for the largest sphere (11.5 mL) and for both planar and SPECT methods with (99m)Tc and (131)I, but were poorest and deviated from known values for smaller objects, most notably for (111)In. SPECT quantification was affected by the partial volume effect in smaller objects and generally showed larger errors than the planar results in these cases for all radionuclides. For the cardiac phantom, results were the most accurate of all of the experiments for all radionuclides. Background subtraction was an important factor influencing these results. The contribution of scattered photons was important in quantification with (131)I; if scatter was not accounted for, activity tended to be overestimated using planar quantification methods. For the torso phantom experiments, results show a clear underestimation of activity when compared to previous experiment with spherical sources for all radionuclides. Despite some variations that were observed as the level of background increased, the SPECT results were more consistent across different activity concentrations. Planar or SPECT quantification on state-of-the-art gamma cameras with appropriate quantitative processing can provide accuracies of better than 10% for large objects and modest target-to-background concentrations; however when smaller objects are used, in the presence of higher background, and for nuclides with more complex decay schemes, SPECT quantification methods generally produce better results. Health Phys. 99(5):688-701; 2010