881 resultados para Pediatric pharmacology.
Resumo:
Objectives: To characterize the epidemiology and risk factors for acute kidney injury (AKI) after pediatric cardiac surgery in our center, to determine its association with poor short-term outcomes, and to develop a logistic regression model that will predict the risk of AKI for the study population. Methods: This single-center, retrospective study included consecutive pediatric patients with congenital heart disease who underwent cardiac surgery between January 2010 and December 2012. Exclusion criteria were a history of renal disease, dialysis or renal transplantation. Results: Of the 325 patients included, median age three years (1 day---18 years), AKI occurred in 40 (12.3%) on the first postoperative day. Overall mortality was 13 (4%), nine of whom were in the AKI group. AKI was significantly associated with length of intensive care unit stay, length of mechanical ventilation and in-hospital death (p<0.01). Patients’ age and postoperative serum creatinine, blood urea nitrogen and lactate levels were included in the logistic regression model as predictor variables. The model accurately predicted AKI in this population, with a maximum combined sensitivity of 82.1% and specificity of 75.4%. Conclusions: AKI is common and is associated with poor short-term outcomes in this setting. Younger age and higher postoperative serum creatinine, blood urea nitrogen and lactate levels were powerful predictors of renal injury in this population. The proposed model could be a useful tool for risk stratification of these patients.
Resumo:
Background: In 1989, we introduced a 1-stage procedure with orthotopic colonic transplants for esophageal stenosis. A pitfall of this procedure is frequent reflux and/or stasis in the transplants from the cologastric anastomosis. Since 1993, we have used a new antireflux wrap (ARW) using an anterior wrap technique similar to the Dor procedure but fixed to the right crus of the diaphragm.Purpose: The purpose of the study was to evaluate ARWs.Method: From 1993 to 2008, the records of 67 patients with an ARW were compared with 27 without ARW (either operated on before 1993 or ARW was not appropriate) after colonic transplant for caustic esophageal stenosis. Both groups otherwise underwent the same surgical procedure. Postoperative esophagograms done on postoperative day 10 were reviewed for the presence of gastrocolonic reflux and stasis in the transplant.Results: The reflux rate on the initial esophagogram was reduced from 48.1% to 7.5% using ARW. The incidence of reflux on later esophagograms was 40.0% with no ARW and 21.4% with ARW. The 25% long-term rate of stasis in the colonic transplant was not increased with ARW.Conclusions: A loose ARW in patients with colonic esophageal replacements reduces gastrocolic reflux without increasing the rate of stasis. In the long term, children adapt better to stasis than to reflux and are thus protected from occult inflammation.
Resumo:
OBJECTIVE: : To determine the influence of nebulizer types and nebulization modes on bronchodilator delivery in a mechanically ventilated pediatric lung model. DESIGN: : In vitro, laboratory study. SETTING: : Research laboratory of a university hospital. INTERVENTIONS: : Using albuterol as a marker, three nebulizer types (jet nebulizer, ultrasonic nebulizer, and vibrating-mesh nebulizer) were tested in three nebulization modes in a nonhumidified bench model mimicking the ventilatory pattern of a 10-kg infant. The amounts of albuterol deposited on the inspiratory filters (inhaled drug) at the end of the endotracheal tube, on the expiratory filters, and remaining in the nebulizers or in the ventilator circuit were determined. Particle size distribution of the nebulizers was also measured. MEASUREMENTS AND MAIN RESULTS: : The inhaled drug was 2.8% ± 0.5% for the jet nebulizer, 10.5% ± 2.3% for the ultrasonic nebulizer, and 5.4% ± 2.7% for the vibrating-mesh nebulizer in intermittent nebulization during the inspiratory phase (p < 0.01). The most efficient nebulizer was the vibrating-mesh nebulizer in continuous nebulization (13.3% ± 4.6%, p < 0.01). Depending on the nebulizers, a variable but important part of albuterol was observed as remaining in the nebulizers (jet and ultrasonic nebulizers), or being expired or lost in the ventilator circuit (all nebulizers). Only small particles (range 2.39-2.70 µm) reached the end of the endotracheal tube. CONCLUSIONS: : Important differences between nebulizer types and nebulization modes were seen for albuterol deposition at the end of the endotracheal tube in an in vitro pediatric ventilator-lung model. New aerosol devices, such as ultrasonic and vibrating-mesh nebulizers, were more efficient than the jet nebulizer.
Resumo:
OBJECTIVES: Pediatric resuscitation is an intense, stressful, and challenging process. The aim of this study was to review the life-threatening pediatric (LTP) emergencies admitted in a Swiss university hospital with regards to patients' demographics, reason for admission, diagnosis, treatment, significant events, critical incidents, and outcomes. METHODS: A retrospective observational cohort study of prospectively collected data was conducted, including all LTP emergencies admitted over a period of 2 years in the resuscitation room (RR). Variables, including indication for transfer, mode of prehospital transportation, diagnosis, and time spent in RR, were recorded. RESULTS: Of the 60,939 pediatric emergencies treated in our university hospital over 2 years, a total of 277 LTP emergencies (0.46%) were admitted in the RR. They included 160 boys and 117 girls, aged 6 days to 15.95 years (mean, 6.69 years; median, 5.06). A medical problem was identified in 55.9% (n = 155) of the children. Of the 122 children treated for a surgical problem, 35 (28.3%) went directly from the RR to the operating room. Hemodynamic instability was noted in 19.5% of all LTP emergencies, of which 1.1% benefited from O negative transfusion. Admission to the intensive care unit was necessary for 61.6% of the children transferred from another hospital. The average time spent in the RR was 46 minutes. The overall mortality rate was 7.2%. CONCLUSIONS: The LTP emergencies accounted for a small proportion of all pediatric emergencies. They were more medical than surgical cases and resuscitation measures because of hemodynamic instability were the most frequent treatment.
Resumo:
Pediatric follicular lymphoma is a rare disease that differs genetically and clinically from its adult counterpart. With the exception of pediatric follicular lymphoma with IRF4-translocation, the genetic events associated with these lymphomas have not yet been defined. We applied array-comparative genomic hybridization and molecular inversion probe assay analyses to formalin-fixed paraffin-embedded tissues from 18 patients aged 18 years and under with IRF4 translocation negative follicular lymphoma. All evaluable cases lacked t(14;18). Only 6 of 16 evaluable cases displayed chromosomal imbalances with gains or amplifications of 6pter-p24.3 (including IRF4) and deletion and copy number neutral-loss of heterozygosity in 1p36 (including TNFRSF14) being most frequent. Sequencing of TNFRSF14 located in the minimal region of loss in 1p36.32 showed nine mutations in 7 cases from our series. Two subsets of pediatric follicular lymphoma were delineated according to the presence of molecular alterations, one with genomic aberrations associated with higher grade and/or diffuse large B-cell lymphoma component and more widespread disease, and another one lacking genetic alterations associated with more limited disease.
Resumo:
BACKGROUND: Advances in nebulizer design have produced both ultrasonic nebulizers and devices based on a vibrating mesh (vibrating mesh nebulizers), which are expected to enhance the efficiency of aerosol drug therapy. The aim of this study was to compare 4 different nebulizers, of 3 different types, in an in vitro model using albuterol delivery and physical characteristics as benchmarks. METHODS: The following nebulizers were tested: Sidestream Disposable jet nebulizer, Multisonic Infra Control ultrasonic nebulizer, and the Aerogen Pro and Aerogen Solo vibrating mesh nebulizers. Aerosol duration, temperature, and drug solution osmolality were measured during nebulization. Albuterol delivery was measured by a high-performance liquid chromatography system with fluorometric detection. The droplet size distribution was analyzed with a laser granulometer. RESULTS: The ultrasonic nebulizer was the fastest device based on the duration of nebulization; the jet nebulizer was the slowest. Solution temperature decreased during nebulization when the jet nebulizer and vibrating mesh nebulizers were used, but it increased with the ultrasonic nebulizer. Osmolality was stable during nebulization with the vibrating mesh nebulizers, but increased with the jet nebulizer and ultrasonic nebulizer, indicating solvent evaporation. Albuterol delivery was 1.6 and 2.3 times higher with the ultrasonic nebulizer and vibrating mesh nebulizers devices, respectively, than with the jet nebulizer. Particle size was significantly higher with the ultrasonic nebulizer. CONCLUSIONS: The in vitro model was effective for comparing nebulizer types, demonstrating important differences between nebulizer types. The new devices, both the ultrasonic nebulizers and vibrating mesh nebulizers, delivered more aerosolized drug than traditional jet nebulizers.
Resumo:
BACKGROUND: Pediatric intensive care patients represent a population at high risk for drug-related problems. There are few studies that compare the activity of clinical pharmacists between countries. OBJECTIVE: To describe the drug-related problems identified and interventions by four pharmacists in a pediatric cardiac and intensive care unit. SETTING: Four pediatric centers in France, Quebec, Switzerland and Belgium. METHOD: This was a six-month multicenter, descriptive and prospective study conducted from August 1, 2009 to January 31, 2010. Drug-related problems and clinical interventions were compiled from four pediatric centers in France, Quebec, Switzerland and Belgium. Data on patients, drugs, intervention, documentation, approval and estimated impact were compiled. MAIN OUTCOME MEASURE: Number and type of drug-related problems encountered in a large pediatric inpatient population. RESULTS: A total of 996 interventions were recorded: 238 (24 %) in France, 278 (28 %) in Quebec, 351 (35 %) in Switzerland and 129 (13 %) in Belgium. These interventions targeted 270 patients (median 21 months old, 53 % male): 88 (33 %) in France, 56 (21 %) in Quebec, 57 (21 %) in Switzerland and 69 (26 %) in Belgium. The main drug-related problems were inappropriate administration technique (29 %), untreated indication (25 %) and supra-therapeutic dose (11 %). The pharmacists' interventions were mostly optimizing the mode of administration (22 %), dose adjustment (20 %) and therapeutic monitoring (16 %). The two major drug classes that led to interventions were anti-infectives for systemic use (23 %) and digestive system and metabolism drugs (22 %). Interventions mainly involved residents and all clinical staff (21 %). Among the 878 (88 %) proposed interventions requiring physician approval, 860 (98 %) were accepted. CONCLUSION: This descriptive study illustrates drug-related problems and the ability of clinical pharmacists to identify and resolve them in pediatric intensive care units in four French-speaking countries.
Resumo:
Research in which children undergo genetic testing for predisposition to adult-onset diseases or disorders can lead to a better understanding of these conditions. It can possibly also help encourage early detection and the development of clinical and preventive interventions for those found to be at increased hereditary risk. Increasingly, predisposition testing is becoming part of pediatric genetic research. However, the paucity of normative texts about the conduct of pediatric research using predisposition genetic testing generates complex legal and ethical issues. Drawing on the current texts that govern predisposition genetic testing in research and the norms of pediatric research, we outline points of consensus and divergence as well as recommendations regarding predisposition genetic testing in pediatric research.
Resumo:
Le but de cette étude était d’évaluer les qualifications de performance du système FlexiWare® chez le rat male Sprague Dawley et le singe Cynomolgus éveillés, ainsi que chez le chien Beagle éveillé et anesthésié, suite à l’administration de produits ayant une activité pharmacologique connue. Les produits utilisés incluaient l’albutérol administré par inhalation, la méthacholine, et le rémifentanil administrés par voie intraveineuse. Une solution saline administré par voie intraveneuse, a été utilisée comme substance témoin. Différentes variables ont servi à évaluer la réponse des animaux (rats, chien, singe). Ces dernières comprenaient la fréquence respiratoire (RR), le volume courant (TV), la ventilation minute (MV). Des paramètres additionnels ont été évalués chez le rat, soit les temps d’inspiration (IT) et d’expiration (ET), le temps du pic de débit expiratoire, les pics de débits inspiratoire et expiratoire, le ratio inspiratoire:expiratoire (I:E), le ratio inspiratoire sur respiration totale (I:TB), et l’écoulement expiratoire moyen (EF50). Les résultats obtenus ont démontré que le système FlexiWare® était suffisamment sensible et spécifique pour dépister, chez les espèces animales utilisées, les effets bronchodilateur, bronchoconstricteur et dépresseur central des substances testées. Il pourrait faire partie des méthodes (ICH 2000) utilisées en pharmacologie de sécurité lors de l’évaluation de substances pharmacologiques sur le système respiratoire des animaux de laboratoire. Les espèces animales utilisées ont semblé s’adapter aisément aux procédures de contention. Les paramètres évalués, RR, TV et MV ont permis de caractériser la réponse des animaux suite à l’administration de produits pharmacologiques à effets connus, judicieusement complétés par les variables de débit. L’ajout de paramètres du temps n’était pas primordiale pour détecter les effets des drogues, mais offre des outils complémentaires d’interpréter les changements physiologiques. Cependant, chez le rat conscient, la période d’évaluation ne devrait pas s’étendre au-delà d’une période de deux heures post traitement. Ces études constituent une évaluation des qualifications de performance de cet appareil et ont démontré de manière originale, la validation concurrentielle, en terme de précision (sensibilité et spécificité) et fiabilité pour différentes variables et sur différentes espèces.
Resumo:
Thèse numérisée par la Division de la gestion de documents et des archives de l'Université de Montréal.
Resumo:
L’immunosuppression optimale après greffe d’organe solide est une balance délicate et propre à chaque individu entre le risque de rejet et les risques liés à une surexposition au traitement immunosuppresseur. L’évaluation de la fonction résiduelle des lymphocytes T après stimulation par un mitogène (pharmacodynamie effective) devrait permettre de mesurer l’effet direct des médicaments immunosuppresseurs sur leur cible. Nous avons étudié différents paramètres de pharmacodynamie effective chez 34 receveurs pédiatriques de greffe d’organes solides traités par tacrolimus et mycophénolate. Les tests proposés dans ce travail sont adaptés au milieu pédiatrique et à une réalisation en temps réel. La quantification du CD25 parmi les CD4 activés par l’OKT3 permet de distinguer deux groupes de patients selon leur degré d’immunosuppression. L’âge médian est plus bas et la concentration plasmatique médiane en MPA plus élevée dans le groupe de patients plus fortement immunosupprimés. L’étude des paramètres immunologiques pouvant influencer la réponse (sécrétion des interleukines, proportion des sous-populations lymphocytaires CD4, CD8, T naïfs et Trég) ainsi que l’étude du pouvoir de restauration de la fonction lymphocytaire par l’Il-2, la guanosine ou la xanthosine, ne permettent pas de mieux comprendre les variabilités interindividuelles observées. Ces résultats devront être confirmés sur une cohorte plus grande de patients afin de juger de leur intérêt en pratique clinique.
Resumo:
Le suivi thérapeutique est recommandé pour l’ajustement de la dose des agents immunosuppresseurs. La pertinence de l’utilisation de la surface sous la courbe (SSC) comme biomarqueur dans l’exercice du suivi thérapeutique de la cyclosporine (CsA) dans la transplantation des cellules souches hématopoïétiques est soutenue par un nombre croissant d’études. Cependant, pour des raisons intrinsèques à la méthode de calcul de la SSC, son utilisation en milieu clinique n’est pas pratique. Les stratégies d’échantillonnage limitées, basées sur des approches de régression (R-LSS) ou des approches Bayésiennes (B-LSS), représentent des alternatives pratiques pour une estimation satisfaisante de la SSC. Cependant, pour une application efficace de ces méthodologies, leur conception doit accommoder la réalité clinique, notamment en requérant un nombre minimal de concentrations échelonnées sur une courte durée d’échantillonnage. De plus, une attention particulière devrait être accordée à assurer leur développement et validation adéquates. Il est aussi important de mentionner que l’irrégularité dans le temps de la collecte des échantillons sanguins peut avoir un impact non-négligeable sur la performance prédictive des R-LSS. Or, à ce jour, cet impact n’a fait l’objet d’aucune étude. Cette thèse de doctorat se penche sur ces problématiques afin de permettre une estimation précise et pratique de la SSC. Ces études ont été effectuées dans le cadre de l’utilisation de la CsA chez des patients pédiatriques ayant subi une greffe de cellules souches hématopoïétiques. D’abord, des approches de régression multiple ainsi que d’analyse pharmacocinétique de population (Pop-PK) ont été utilisées de façon constructive afin de développer et de valider adéquatement des LSS. Ensuite, plusieurs modèles Pop-PK ont été évalués, tout en gardant à l’esprit leur utilisation prévue dans le contexte de l’estimation de la SSC. Aussi, la performance des B-LSS ciblant différentes versions de SSC a également été étudiée. Enfin, l’impact des écarts entre les temps d’échantillonnage sanguins réels et les temps nominaux planifiés, sur la performance de prédiction des R-LSS a été quantifié en utilisant une approche de simulation qui considère des scénarios diversifiés et réalistes représentant des erreurs potentielles dans la cédule des échantillons sanguins. Ainsi, cette étude a d’abord conduit au développement de R-LSS et B-LSS ayant une performance clinique satisfaisante, et qui sont pratiques puisqu’elles impliquent 4 points d’échantillonnage ou moins obtenus dans les 4 heures post-dose. Une fois l’analyse Pop-PK effectuée, un modèle structural à deux compartiments avec un temps de délai a été retenu. Cependant, le modèle final - notamment avec covariables - n’a pas amélioré la performance des B-LSS comparativement aux modèles structuraux (sans covariables). En outre, nous avons démontré que les B-LSS exhibent une meilleure performance pour la SSC dérivée des concentrations simulées qui excluent les erreurs résiduelles, que nous avons nommée « underlying AUC », comparée à la SSC observée qui est directement calculée à partir des concentrations mesurées. Enfin, nos résultats ont prouvé que l’irrégularité des temps de la collecte des échantillons sanguins a un impact important sur la performance prédictive des R-LSS; cet impact est en fonction du nombre des échantillons requis, mais encore davantage en fonction de la durée du processus d’échantillonnage impliqué. Nous avons aussi mis en évidence que les erreurs d’échantillonnage commises aux moments où la concentration change rapidement sont celles qui affectent le plus le pouvoir prédictif des R-LSS. Plus intéressant, nous avons mis en exergue que même si différentes R-LSS peuvent avoir des performances similaires lorsque basées sur des temps nominaux, leurs tolérances aux erreurs des temps d’échantillonnage peuvent largement différer. En fait, une considération adéquate de l'impact de ces erreurs peut conduire à une sélection et une utilisation plus fiables des R-LSS. Par une investigation approfondie de différents aspects sous-jacents aux stratégies d’échantillonnages limités, cette thèse a pu fournir des améliorations méthodologiques notables, et proposer de nouvelles voies pour assurer leur utilisation de façon fiable et informée, tout en favorisant leur adéquation à la pratique clinique.
Resumo:
Commentaire / Commentary
Resumo:
Dans les pays industrialisés, les rétinopathies ischémiques proliférantes telles que la rétinopathie diabétique et la rétinopathie du prématuré sont les principales causes de cécité chez les individus en âge de travailler et la population pédiatrique. Ces pathologies sont caractérisées par une dégénérescence microvasculaire initiale suivie d’une hyper-vascularisaton compensatoire disproportionnée et pathologique. Les sirtuines constituent une importante famille de protéines impliquées dans le métabolisme et la réponse au stress. Plus particulièrement, sirtuine 3 (SIRT3) est une déacétylase mitochondriale primordiale qui agit au cœur du métabolisme énergétique et de l’activation de nombreuses voies métaboliques oxydatives. Nos résultats démontrent pour la première fois qu’une déficience en SIRT3 diminue la sévérité des lésions vasculaires dans le modèle murin de rétinopathie induite par l’oxygène (OIR). En plus de stimuler l’angiogénèse, l’absence de SIRT3 est aussi associée à une augmentation de la glycolyse, possiblement en activant la famille de gènes 6-phosphofructo-2-kinase/fructose-2,6-bisphosphatase (PFKFB). Nous suggérons que le manque de SIRT3 est impliqué dans l’effet Warburg et procure ainsi un avantage prolifératif et protecteur dans l’OIR. La présente étude propose SIRT3 comme nouvelle cible thérapeutique potentielle dans la rétinopathie du prématuré, une maladie dont les complications désastreuses persistent tout au long de la vie.
Resumo:
La Fibrosis Quística es la enfermedad autosómica recesiva mas frecuente en caucásicos. En Colombia no se conoce la incidencia de la enfermedad, pero investigaciones del grupo de la Universidad del Rosario indican que podría ser relativamente alta. Objetivo: Determinar la incidencia de afectados por Fibrosis Quística en una muestra de recién nacidos de la ciudad de Bogotá. Metodología: Se analizan 8.297 muestras de sangre de cordón umbilical y se comparan tres protocolos de tamizaje neonatal: TIR/TIR, TIR/DNA y TIR/DNA/TIR. Resultados: El presente trabajo muestra una incidencia de 1 en 8.297 afectados en la muestra analizada. Conclusiones: Dada la relativamente alta incidencia demostrada en Bogotá, se justifica la implementación de Tamizaje Neonatal para Fibrosis Quística en Colombia.