232 resultados para Pdms


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pancreatic polypeptide (PP) has been isolated from extracts of the pancreas of the European hedgehog (Erinaceous europaeus) which is a representative of the order Insectivora, deemed to be the most primitive group of placental mammals. Pancreatic tissues were extracted in acidified ethanol and the peptide was purified chromatographically using a PP C-terminal hexapeptide amide specific radioimmunoassay to monitor purification. Two major PP-immunoreactive peptides were baseline-resolved following the final analytical reverse phase HPLC fractionation. Each was separately subjected to plasma desorption mass spectroscopy (PDMS) and gas-phase sequencing. The molecular masses of each peptide were similar: (I) 4237.6 +/- 4 Da and (II) 4238.2 +/- 4 Da. The full primary structures of each peptide were deduced and these were identical: VPLEPVYPGDNATPEQMAHYAAELRRYINMLTRPRY. The peptides were deemed to be amidated due to their full molar cross-reactivity with the amide-requiring PP antiserum employed in radioimmunoassay. The molecular mass (4233.8 Da) calculated from the sequence was in close agreemeent with PDMS estimates and the reason for the different retention times of each peptide is unknown at present. Hedgehog PP exhibits only 2 unique amino acid substitutions, at positions 1 (Val) and 19 (His), when compared with other mammalian analogues.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We previously reported nonaqueous silicone elastomer gels (SEGs) for sustained vaginal administration of the CCR5-targeted entry inhibitor maraviroc (MVC). Here, we describe chemically modified SEGs (h-SEGs) in which the hydrophobic cyclomethicone component was partially replaced with relatively hydrophilic silanol-terminated polydimethylsiloxanes (st-PDMS). MVC and emtricitabine (a nucleoside reverse transcriptase inhibitor), both currently under evaluation as topical microbicides to counter sexual transmission of human immunodeficiency virus type 1 (HIV-1), were used as model antiretroviral (ARV) drugs. Gel viscosity and in vitro ARV release were significantly influenced by st-PDMS molecular weight and concentration in the h-SEGs. Unexpectedly, gels prepared with lower molecular weight grades of st-PDMS showed higher viscosities. h-SEGs provided enhanced release over 24 h compared with aqueous hydroxyethylcellulose (HEC) gels, did not modify the pH of simulated vaginal fluid (SVF), and were shown to less cytotoxic than standard HEC vaginal gel. ARV solubility increased as st-PDMS molecular weight decreased (i.e., as percentage hydroxyl content increased), helping to explain the in vitro release trends. Dye ingression and SVF dilution studies confirmed the increased hydrophilicity of the h-SEGs. h-SEGs have potential for use in vaginal drug delivery, particularly for ARV-based HIV-1 microbicides.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rapid and sensitive detection of viral infections associated with Bovine Respiratory Disease (BRD) in live animals is recognized as key to minimizing the impact of this disease. ELISA-based testing is limited as it typically relies on the detection of a single viral antibody subtype within an individual test sample and testing is relatively slow and expensive. We have recently initiated a new project entitled AgriSense to develop a novel low-cost and label-free, integrated bimodal electronic biosensor system for BRD. The biosensor system will consist of an integrated multichannel thin-film-transistor biosensor and an electrochemical impedance spectroscopy biosensor, interfaced with PDMS-based microfluidic sample delivery channels. By using both sensors in tandem, nonspecific binding biomolecules must have the same mass to charge ratio as the target analyte to elicit equivalent responses from both sensors. The system will target simultaneous multiplexed sensing of the four primary viral agents involved in the development of BRD: bovine herpesvirus-1 (BHV-1), bovine parainfluenza virus-3 (BPIV-3), bovine respiratory syncytial virus (BRSV), and bovine viral diarrhea (BVD). Optimized experimental conditions derived through model antigen-antibody studies will be applied to the detection of serological markers of BRD-related infections based on IgG interaction with a panel of sensor-immobilized viral proteins. This rapid, “cowside” multiplex sensor capability presents a major step forward in disease diagnosis, helping to ensure the integrity of the agri-food supply chain by reducing the risk of disease spread during animal movement and transport.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O desenvolvimento de tecnologias para a deteção de vírus é um tema de grande interesse em medicina de diagnóstico. Neste contexto, os biossensores têm-se revelado importantes ferramentas bioanalíticas, na medida em que permitem efetuar deteções moleculares de forma rápida, específica, reprodutível e com baixo custo associado. No âmbito desta dissertação, estabeleceram-se metodologias para a deteção fluorescente do fator de infetividade viral (Vif) do VIH através de um nanossensor ótico funcionalizado com anticorpos recombinantes anti-Vif, fragmentos variáveis de cadeia simples 4BL. Quantum dots carboxílicos conjugados a proteínas Vif são excitados a um comprimento de onda de 405 nm, transmitindo luz fluorescente a 605 nm a um fotodetetor de silício amorfo hidrogenado com um filtro de fluorescência integrado. Para implementar um sistema de deteção sensível e eficiente, estudaram-se estratégias de ativação de superfície em chips de vidro. A variabilidade das condições experimentais de um protocolo de silanização com (3-mercaptopropil)-trimetoxisilano (MPTS) foi avaliada através da análise de ângulos de contacto e densidades moleculares de fluoresceína funcionalizada com maleimida. Estabeleceu-se que, uma incubação dos substratos por 4 h com 5% (w/v) MPTS, seguida de cura a 110 ºC por 2 h, e redução com 10 mM ditiotreitol por 30 min, promove a formação de camadas de organosilanos de qualidade com grupos tiol reativos bem orientados. Estratégias de imobilização do elemento recetor foram testadas em substratos de vidro ativados e em sistemas de microfluídica vidro/PDMS, tomando por base o tag de afinidade, glutationa S-transferase (GST), do anticorpo recombinante. Vidros funcionalizados com glutationa e anti-GST mostraram-se igualmente reativos ao anticorpo GST-4BL, resultando uma capacidade de ligação do antigénio de aproximadamente 4.76 x 1010 moléculas/cm2 de QD-Vif, o que corresponde a 15% da cobertura máxima de superfície. Dos ensaios em sistemas de microfluídica resultaram sinais fracos e poucos reprodutíveis, destacando a necessidade de desenvolver metodologias de funcionalização mais apropriadas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de Mestrado, Qualidade em Análises, Faculdade de Ciências e Tecnologia, Universidade do Algarve, 2015

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia do Ambiente, perfil de Ordenamento do Território e Impactes Ambientais

Relevância:

10.00% 10.00%

Publicador:

Resumo:

L'élongation cellulaire de cellules cultivant bout comme hyphae fongueux, inculquez hairs, des tubes de pollen et des neurones, est limité au bout de la cellule, qui permet à ces cellules d'envahir l'encerclement substrate et atteindre une cible. Les cellules cultivant bout d'équipement sont entourées par le mur polysaccharide rigide qui régule la croissance et l'élongation de ces cellules, un mécanisme qui est radicalement différent des cellules non-walled. La compréhension du règlement du mur de cellule les propriétés mécaniques dans le contrôle de la croissance et du fonctionnement cellulaire du tube de pollen, une cellule rapidement grandissante d'équipement, est le but de ce projet. Le tube de pollen porte des spermatozoïdes du grain de pollen à l'ovule pour la fertilisation et sur sa voie du stigmate vers l'ovaire le tube de pollen envahit physiquement le stylar le tissu émettant de la fleur. Pour atteindre sa cible il doit aussi changer sa direction de croissance les temps multiples. Pour évaluer la conduite de tubes de pollen grandissants, un dans le système expérimental vitro basé sur la technologie de laboratoire-sur-fragment (LOC) et MEMS (les systèmes micro-électromécaniques) ont été conçus. En utilisant ces artifices nous avons mesuré une variété de propriétés physiques caractérisant le tube de pollen de Camélia, comme la croissance la croissance accélérée, envahissante et dilatant la force. Dans une des organisations expérimentales les tubes ont été exposés aux ouvertures en forme de fente faites de l'élastique PDMS (polydimethylsiloxane) la matière nous permettant de mesurer la force qu'un tube de pollen exerce pour dilater la croissance substrate. Cette capacité d'invasion est essentielle pour les tubes de pollen de leur permettre d'entrer dans les espaces intercellulaires étroits dans les tissus pistillar. Dans d'autres essais nous avons utilisé l'organisation microfluidic pour évaluer si les tubes de pollen peuvent s'allonger dans l'air et s'ils ont une mémoire directionnelle. Une des applications auxquelles le laboratoire s'intéresse est l'enquête de processus intracellulaires comme le mouvement d'organelles fluorescemment étiqueté ou les macromolécules pendant que les tubes de pollen grandissent dans les artifices LOC. Pour prouver que les artifices sont compatibles avec la microscopie optique à haute résolution et la microscopie de fluorescence, j'ai utilisé le colorant de styryl FM1-43 pour étiqueter le système endomembrane de tubes de pollen de cognassier du Japon de Camélia. L'observation du cône de vésicule, une agrégation d'endocytic et les vésicules exocytic dans le cytoplasme apical du bout de tube de pollen, n'a pas posé de problèmes des tubes de pollen trouvés dans le LOC. Pourtant, le colorant particulier en question a adhéré au sidewalls du LOC microfluidic le réseau, en faisant l'observation de tubes de pollen près du difficile sidewalls à cause du signal extrêmement fluorescent du mur. Cette propriété du colorant pourrait être utile de refléter la géométrie de réseau en faisant marcher dans le mode de fluorescence.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

High aspect ratio polymeric micro-patterns are ubiquitous in many fields ranging from sensors, actuators, optics, fluidics and medical. Second generation PDMS molds are replicated against first generation silicon molds created by deep reactive ion etching. In order to ensure successful demolding, the silicon molds are coated with a thin layer of C[subscript 4]F[subscript 8] plasma polymer to reduce the adhesion force. Peel force and demolding status are used to determine if delamination is successful. Response surface method is employed to provide insights on how changes in coil power, passivating time and gas flow conditions affect plasma polymerization of C[subscript 4]F[subscript 8].

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The non-Newtonian flow of dilute aqueous polyethylene oxide (PEO) solutions through microfabricated planar abrupt contraction-expansions is investigated. The contraction geometries are fabricated from a high-resolution chrome mask and cross-linked PDMS gels using the tools of soft-lithography. The small length scales and high deformation rates in the contraction throat lead to significant extensional flow effects even with dilute polymer solutions having time constants on the order of milliseconds. The dimensionless extra pressure drop across the contraction increases by more than 200% and is accompanied by significant upstream vortex growth. Streak photography and videomicroscopy using epifluorescent particles shows that the flow ultimately becomes unstable and three-dimensional. The moderate Reynolds numbers (0.03 ≤ Re ≤ 44) associated with these high Deborah number (0 ≤ De ≤ 600) microfluidic flows results in the exploration of new regions of the Re-De parameter space in which the effects of both elasticity and inertia can be observed. Understanding such interactions will be increasingly important in microfluidic applications involving complex fluids and can best be interpreted in terms of the elasticity number, El = De/Re, which is independent of the flow kinematics and depends only on the fluid rheology and the characteristic size of the device.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Els polímers són una sèrie de compostos que troben un ampli ventall d'aplicacions en la indústria actual. Un exemple són les espumes de poliuretà, estructures de tipus cel·lular obtingudes mitjançant la reacció química entre compostos de tipus isocianat i compostos de tipus poliol (polièters amb diferent nombre de grups hidroxil). És imprescindible l'ús d'additius d'estructura tensioactiva (surfactants de silicona) per estabilitzar el procés d'espumació i per proporcionar una estructura cel·lular ordenada i homogènia en mida i distribució. La síntesis i caracterització de les molècules precursores (polihidrosiloxans i polièters al·lílics), l'estudi de la reacció d'hidrosililació com a via d'obtenció dels diferents surfactants per reacció d'addició entre els polihidrosiloxans i els polièters al·lílics i la caracterització i avaluació en formulacions comercials de poliuretà dels surfactants sintetitzats han constituït els objectius del present treball. MEMÒRIA La Tesi Doctoral ha estat presentada seguint el següent esquema: CAPÍTOL I. INTRODUCCIÓ A LA QUÍMICA DEL POLIURETÀ. Es presenten els principis de la química del poliuretà, fent esment dels recents avenços en la síntesis i caracterització d'aquests compostos polimèrics, així com un apartat concret centrat en els surfactants de silicona. Es presenten les estructures habituals d'aquests compostos comercials i es detallen les reaccions de síntesi i les característiques físiques que aquests compostos proporcionen a les espumes de poliuretà. CAPÍTOL II. OBJECTIUS. 1.- Síntesis y caracterització d'una àmplia gamma de poliglicols al·lílics i de polihidrosiloxans amb grups hidrur reactius, ambdós precursors d'estructures polimèriques de tipus surfactant. 2.- Estudi de la reacció d'hidrosililació com a via de formació d'enllaços Si-C no hidrolitzables, mitjançant la reacció d'addició entre els substrats al·lílics insaturats i els polisiloxans amb grups hidrur reactius. 3.- Caracterització de les estructures polimèriques de tipus surfactant sintetitzades i avaluació d'aquestes en formulacions de poliuretà, a fi de relacionar l'estructura química d'aquests oligómers amb els efectes físics que originen en l'espuma de poliuretà. CAPÍTOL III. SÍNTESI I CARACTERITZACIÓ DE SUBSTRATS AL·LÍLICS INSATURATS DE TIPUS POLIGLICOL. S'han caracteritzat per HPLC-UV una sèrie de polietilenglicols comercials. S'ha estudiat la reacció de derivatització al·lílica sobre els grups hidroxil dels polièters comercials (PEG, PPG i copolímers PEG-PPG) i s'han caracteritzat exhaustivament els productes sintetitzats (1H,13C-RMN, GC, GC-MS, FTIR, ESI-MS, HPLC-UV). S'ha iniciat un estudi de polimerització aniònica sobre nous epòxids amb un punt de diversitat molecular, sintetitzant-se i caracteritzant-se els corresponents nous polièters obtinguts. CAPÍTOL IV. SÍNTESI I CARACTERITZACIÓ DE POLIHIDROSILOXANS REACTIUS. S'estudia la síntesis de polihidrosiloxans amb grups hidrur reactius, mitjançant la reacció de polimerització aniònica d'obertura d'anell ("AROP, anionic ring opening polimerization") i mitjançant la reacció de polimerització per equilibració catiònica. Es presenta una caracterització exhaustiva dels productes sintetitzats i es descriu la naturalesa de la microestructura polimèrica a partir de la distribució bivariant dels copolímers PDMS-co-PHMS (poli(dimetilsiloxà)-co-poli(hidrometilsiloxà)). CAPÍTOL V. ESTUDI SISTEMÀTIC DE LA REACCIÓ D'HIDROSILILACIÓ. S'ha estudiat la reacció d'hidrosililació amb la finalitat de sintetitzar estructures copolimèriques poliglicol-polisiloxà a partir de la reacció de polisiloxans hidrur reactius i polièters al·lílics. S'han provat diferents catalitzadors (Pt/C 5%, cat. de Speier i cat. de Karstedt), s'han sintetitzat diferents estructures tensoactives (lineals i ramificades) i s'ha modelitzat les diferents reaccions secundàries observades, per presentar un estudi mecanístic de la reacció d'hidrosililació aplicada a la síntesis de molècules d'elevat PM a partir de la reacció entre substrats al·lílics insaturats i polihidrosiloxans. CAPÍTOL VI. AVALUACIÓ DELS SURFACTANTS EN FORMULACIONS DE POLIURETÀ. S'ha estudiat la idoneïtat dels surfactants de silicona sintetitzats en diferents formulacions de poliuretà comercials. S'ha relacionat el comportament físic d'aquests surfactants en les espumes de poliuretà amb la seva estructura química a partir de l'anàlisi per microscòpia electrònica de rastreig. CAPÍTOL VII. CONCLUSIONS. S'han esposat les conclusions extretes de cada capítol.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Neuroprostheses interfaced with transected peripheral nerves are technological routes to control robotic limbs as well as convey sensory feedback to patients suffering from traumatic neural injuries or degenerative diseases. To maximize the wealth of data obtained in recordings, interfacing devices are required to have intrafascicular resolution and provide high signal-to-noise ratio (SNR) recordings. In this paper, we focus on a possible building block of a three-dimensional regenerative implant: a polydimethylsiloxane (PDMS) microchannel electrode capable of highly sensitive recordings in vivo. The PDMS 'micro-cuff' consists of a 3.5 mm long (100 µm × 70 µm cross section) microfluidic channel equipped with five evaporated Ti/Au/Ti electrodes of sub-100 nm thickness. Individual electrodes have average impedance of 640 ± 30 kΩ with a phase angle of −58 ± 1 degrees at 1 kHz and survive demanding mechanical handling such as twisting and bending. In proof-of-principle acute implantation experiments in rats, surgically teased afferent nerve strands from the L5 dorsal root were threaded through the microchannel. Tactile stimulation of the skin was reliably monitored with the three inner electrodes in the device, simultaneously recording signal amplitudes of up to 50 µV under saline immersion. The overall SNR was approximately 4. A small but consistent time lag between the signals arriving at the three electrodes was observed and yields a fibre conduction velocity of 30 m s−1. The fidelity of the recordings was verified by placing the same nerve strand in oil and recording activity with hook electrodes. Our results show that PDMS microchannel electrodes open a promising technological path to 3D regenerative interfaces.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We are reporting on the fabrication and electrical characterization of a novel elastomer based micro-cuff neural interface. Electrodes are gold (Au) tracks of sub-100nm thickness and are thermally evaporated on a 0.5 mm thick polydimethylsiloxane (PDMS) substrate. We investigate how electrode area and immersion in phosphate buffered saline (PBS) at 37°C influence electrode impedance. A microfluidic channel is bonded to the electrode array to form the cuff. In an acute, in-vivo, proof-of-principle recording, the device is capable of detecting light stroking and pinch of a hind leg of an anaesthetized rat.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We have fabricated a compliant neural interface to record afferent nerve activity. Stretchable gold electrodes were evaporated on a polydimethylsiloxane (PDMS) substrate and were encapsulated using photo-patternable PDMS. The built-in microstructure of the gold film on PDMS allows the electrodes to twist and flex repeatedly, without loss of electrical conductivity. PDMS microchannels (5mm long, 100μm wide, 100μm deep) were then plasma bonded irreversibly on top of the electrode array to define five parallel-conduit implants. The soft gold microelectrodes have a low impedance of ~200kΩ at the 1kHz frequency range. Teased nerves from the L6 dorsal root of an anaesthetized Sprague Dawley rat were threaded through the microchannels. Acute tripolar recordings of cutaneous activity are demonstrated, from multiple nerve rootlets simultaneously. Confinement of the axons within narrow microchannels allows for reliable recordings of low amplitude afferents. This electrode technology promises exciting applications in neuroprosthetic devices including bladder fullness monitors and peripheral nervous system implants.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A method for the determination of volatile organic compounds (VOCs) in recycled polyethylene terephthalate and high-density polyethylene using headspace sampling by solid-phase microextraction and gas chromatography coupled to mass spectrometry detection is presented. This method was used to evaluate the efficiency of cleaning processes for VOC removal from recycled PET. In addition, the method was also employed to evaluate the level of VOC contamination in multilayer packaging material containing recycled HDPE material. The optimisation of the extraction procedure for volatile compounds was performed and the best extraction conditions were found using a 75 mu m carboxen-polydimethylsiloxane (CAR-PDMS) fibre for 20 min at 60 degrees C. The validation parameters for the established method were linear range, linearity, sensitivity, precision (repeatability), accuracy (recovery) and detection and quantification limits. The results indicated that the method could easily be used in quality control for the production of recycled PET and HDPE. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this article, a novel polydimethylsiloxane/activated carbon (PDMS-ACB) material is proposed as a new polymeric phase for stir bar sorptive extraction (SBSE). The PDMS-ACB stir bar, assembled using a simple Teflon (R)/glass capillary mold, demonstrated remarkable stability and resistance to organic solvents for more than 150 extractions. The SBSE bar has a diameter of 2.36 mm and a length of 2.2 cm and is prepared to contain 92 mu L of polymer coating. This new PDMS-ACB bar was evaluated for its ability to determine the quantity of pesticides in sugarcane juice samples by performing liquid desorption (LD) in 200 mu L of ethyl acetate and analyzing the solvent through gas chromatography coupled with mass spectrometry (GC-MS). A fractional factorial design was used to evaluate the main parameters involved in the extraction procedure. Then, a central composite design with a star configuration was used to optimize the significant extraction parameters. The method used demonstrated a limit of quantification (LOQ) of 0.5-40 mu g/L, depending on the analyte detected; the amount of recovery varied from 0.18 to 49.50%, and the intraday precision ranged from 0.072 to 8.40%. The method was used in the analysis of real sugarcane juice samples commercially available in local markets.