915 resultados para PLASMON RESONANCE SENSORS


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Surface plasmon resonances of arrays of parallel copper nanowires, embedded in ion track-etched polycarbonate membranes, were investigated by systematic changes of nanowires’ topology and arrays area density. The extinction spectra exhibit two peaks which are attributed to interband transitions of Cu bulk metal and to a dipolar surface plasmon resonance, respectively. The resonances were investigated as a function of wire diameter and length, mean distance between adjacent wires, and angle of incidence of the light field with respect to the long wire axis. The dipolar peak shifts to larger wavelengths with increasing diameter and length, and diminishing mean distance between adjacent wires. Additionally, the shape effect on the dipolar peak is investigated.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A label-free and highly sensitive impedimetric aptasensor based on a polyamidoamine dendrimer modified gold electrode was developed for the determination of thrombin. Amino-terminated polyamidoamine dendrimer was firstly covalently attached to the cysteine functionalized gold electrode through glutaraldehyde coupling. Subsequently, the dendrimer was activated with glutaraldehyde, and amino-modified thrombin aptamer probe was immobilized onto the activated dendrimer monolayer film. The layer-by-layer assembly process was traced by surface plasmon resonance and electrochemical impedance spectroscopy.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

An automated biomolecular interaction analysis instrument (BI-Acore) based on surface plasmon resonance (SPR) has been used to determine human immunoglobulin G (IgG) in real time. Polyclonal anti-human IgG antibody was covalently immobilized to a carboxymethyldextran modified gold film surface. The samples of human IgG prepared in HBS buffer were poured over the immobilized surface. The signal amplification antibody was applied to amplify the response signal. After each measurement, the surface was regenerated with 0.1 mol/L H3PO4. The assay was rapid, requiring only 30 min for antibody immobilization and 20 min for each subsequent process of immune binding, antibody amplification and regeneration. The antibody immobilized surface had good response to human IgG in the range of 0.12-60 nmol/L with a detection limit of 60 pmol/L. The same antibody immobilized surface could be used for more than 110 cycles of binding, amplification and regeneration. The results demonstrate that the sensitivity, specificity and reproducibility of amplified immunoassay using real-time BIA technology are satisfactory.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The kinetic analysis of the interaction between tumor necrosis factor(TNF) and its monoclonal antibody was performed by surface plasmon resonance(SPR) technique. The monoclonal antibody was immobilized to the surface of CM5 sensor chip by amine coupling. TNF at different concentrations was injected across the mAb immobilized surface. The interaction was recorded in real time and could be seen on the sensorgram. One cycle, including association, dissociation and regeneration, lasted no more than 15 min. The interaction results was evaluated using 1 : 1 Langmuir binding model. The kinetic rate constants were calculated to be: k =1.68 X 10(3) L (.) mol(-1) (.) s(-1), k(d) = 1.73 X 10(-4) s(-1), and the affinity constants K-A = 9. 7 X 10(3) L (.) mol(-1), K-r)= 1. 03 X 10(-7) Mol (.) L-1. The X-2 was 3.47, which showed that the interaction is consistent with the 1 : I model. We can see from the results that although there are two binding sites in one mAb molecule, TNF reacts with each site in an independent and noncooperative manner.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Layer-by-layer assembly of multilayer films of streptavidin and biotinylated antibody was completed on the streptavidin coated surface. Real-time biomolecular interaction analysis (BIA) based on surface plasmon resonance technique was used to monitor the multilayer assembly in solution continuously. The results indicate that the uniform multilayer film can be fabricated successfully based on the strong interaction between streptavidin and biotin. The mean surface mass concentration of each adsorption layer is 1. 32 ng/mm(2) for biotinylated antibody, 2. 93 ng/mm(2) for streptavidin, according to the correlation of SPR response with surface concentration.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Multiplexed immunochemical detection platforms offer the potential to decrease labour demands, increase sample throughput and decrease overall time to result. A prototype four channel multiplexed high throughput surface plasmon resonance biosensor was previously developed, for the detection of food related contaminants. A study focused on determining the instruments performance characteristics was undertaken. This was followed by the development of a multiplexed assay for four high molecular weight proteins. The protein levels were simultaneously evaluated in serum samples of 10-week-old veal calves (n = 24) using multiple sample preparation methods. Each of the biosensor's four channels were shown to be independent of one another and produced multiplexed within run repeatability (n = 6) ranging from 2.0 to 6.7%CV, for the four tested proteins, whilst between run reproducibility (n = 4) ranged from 1.5 to 8.9%CV. Four calibration curves were successfully constructed before serum sample preparation was optimised for each protein. Multiplexed concentration analysis was successfully performed on four channels revealing that each proteins concentration was consistent across the twenty-four tested animals. Signal reproducibility (n > 19) on a further long term study revealed coefficient of variation ranging from 1.1% to 7.3% and showed that the multiplexed assay was stable for at least 480 cycles. These findings indicate that the performance characteristics fall within the range of previously published data for singleplex optical biosensors and that the multiplexing biosensor is fit-for-purpose for simultaneous concentration analysis in many different types of applications such as the multiplexed detection of markers of growth-promoter abuse and multiplexed detection of residues of concern in food safety. © 2013 Elsevier B.V.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Surface plasmon resonance (SPR)-based biosensor is a popular platform for real-time monitoring and sensitive detection for a myriad of targets. However, only a few studies have reported the use of bacteriophages as specific binders for SPR-based detection. This study aimed to demonstrate how filamentous M13 bacteriophages expressing 12-mer peptides can be employed in an SPR-based assay, using a Salmonella-specific bacteriophage as a model binder to detect the foodborne bacterium Salmonella. Several important factors (immobilization buffers and methods, and interaction buffers) for a successful bacteriophage-based SPR assay were optimized. As a result, a Salmonella-specific bacteriophage-based SPR assay was achieved, with very low cross reactivity with other non-target foodborne pathogens and detection limits of 8.0 × 107 and 1.3 × 107 CFU/mL for one-time and five-time immobilized sensors, respectively. This proof-of-concept study demonstrates the feasibility of using M13 bacteriophages expressing target-specific peptides as a binder in a rapid and label-free SPR assay for pathogen detection.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Protein G-coated magnetic particles (MPs) were used as immobilisation supports for an antibody against okadaic acid (MAb(OA)) and carriers into a surface plasmon resonance (SPR) device for the development of a direct competitive immunosensor for okadaic acid (OA). SPR analysis of MAb(OA)-MP conjugates demonstrated that conjugations were successful with complete immobilisation of all the antibody biomolecules onto the MPs. Moreover, MAb(OA)-MP conjugates provided up to 11-fold higher SPR signals, compared to free MAb(OA). The use of conjugates in the direct competition assay provided a 3-fold lower LOD mu g/L (2.6 mu g of OA/L, equivalent to 12 mu g of OA/kg mussel meat). The presence of mussel matrix did not interfere in the OA quantification as seen in the calibration curves. Mussel samples, obtained from Ebro Delta's bays (NW Mediterranean) during a diarrheic shellfish poisoning (DSP) event and in the presence of Dinophysis sacculus, an OA producer, in the shellfish production area, were analysed with the MP-based SPR immunosensor. The OA contents correlated with those obtained by liquid chromatography-tandem mass spectrometry (LC-MS/MS) (y = 0.984x -5.273, R-2 = 0.789, p <0.001) and by mouse bioassay (MBA).

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Thin, oxidised Al films grown an one face of fused silica prisms are exposed. tinder ambient conditions, to single shots from an excimer laser operating at wavelength 248 nm. Preliminary characterisation of the films using attenuated total reflection yields optical and thickness data for the Al and Al oxide layers; this step facilitates the subsequent, accurate tuning of the excimer laser pulse to the: surface plasmon resonance at the Al/(oxide)/air interface and the calculation of the fluence actually absorbed by the thin film system. Ablation damage is characterised using scanning electron, and atomic force microscopy. When the laser pulse is incident, through the prism on the sample at less than critical angle, the damage features are molten in nature with small islands of sub-micrometer dimension much in evidence, a mechanism of film melt-through and subsegment blow-off due to the build up of vapour pressure at the substrate/film interface is appropriate. By contrast, when the optical input is surface plasmon mediated, predominately mechanical damage results with the film fragmenting into large flakes of dimensions on the order of 10 mu m. It is suggested that the ability of surface plasmons to transport energy leads to enhanced, preferential absorption of energy at defect sites causing stress throughout the film which exceeds the ultimate tensile stress for the film: this in turn leads to film break-up before melting can onset. (C) 1998 Elsevier Science B.V.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Here, we demonstrate that quasi self-standing Au nanorod arrays prepared with plasma polymerisation deposited SiO2 dielectric spacers support surface enhanced fluorescence (SEF) while maintaining high signal reproducibility. We show that it is possible to find a balance between enhanced radiative and non-radiative decay rates at which the fluorescent intensity is maximized. The SEF signal optimised with a 30 nm spacer layer thickness showed a 3.5-fold enhancement with a signal variance of <15% thereby keeping the integrity of the nanorod array. We also demonstrate the decreased importance of obtaining resonance conditions when localized surface plasmon resonance is positioned within the spectral region of Au interband transitions. Procedures for further increasing the SEF enhancement factor are also discussed.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

An ultrathin layer of metasurface that almost completely annihilates the reflection of light (>99.5%) over a wide range of incident angles (>80°) is experimentally demonstrated. Such zero-reflectance metafilms exhibit optimal performance for plasmonic sensing, since their sensitivity to changes of local refractive index is far superior to films of nonzero reflectance. Since both main detection mechanisms tracking intensity changes and wavelength shifts are improved, zero-reflectance metafilms are optimal for localized surface plasmon resonance molecular sensing. Such nanostructures have significant opportunities in many areas, including enhanced light harvesting as well as in developing high-performance molecular sensors for a wide range of chemical and biomedical applications.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Les propriétés d'une nouvelle classe de chimie de surface basée sur les monocouches auto-assemblées de liquides ioniques (ILs-SAMs), ont été étudiées pour une utilisation dans la construction de biocapteurs basés sur la résonance des plasmons de surface (SPR). Les biocapteurs sont utiles pour détecter des biomolécules spécifiques dans une matrice biologique complexe. Cependant, le signal analytique de la biomolécule spécifique peut être masqué par l’adsorption non spécifique de la matrice biologique, produisant une réponse faussement positive. Par ailleurs, l'activité des récepteurs moléculaires est souvent réduite par des techniques d'immobilisation chimique. Ainsi, il est essentiel de déterminer une surface idéale pour la préparation de biocapteurs. Les liquides ioniques sont bien connus pour favoriser l'activité des récepteurs moléculaires et cette étude enquête si cette propriété importante peut se traduire sur des capteurs SPR. Différents liquides ioniques ont été utilisés pour former des monocouches auto-assemblées sur une surface d'or. Les ILs-SAMs sont tous basés sur les sels de mercapto-(chaîne alkyle)nCH2-méthylimidazolium avec différentes chaînes alkyles (n = 3, 6, 9, 12) et différents contre-anions (Br-, BF4-, PF6-, NTf2-). Des études cinétiques de l'adsorption non spécifique de sérum bovin ont été réalisées sur des capteurs SPR avec un instrument construit sur mesure, basé sur l'interrogation des longueurs d’ondes SPR sur un prisme d’inversion d’image (dove). Par la suite, l’anti-IgG de chèvre sélective à l’IgG humain a été utilisé en tant que modèle pour la confection de biocapteurs sur les ILs-SAMs. En solution, il est possible d’effectuer des échanges du contre-anion des liquides ioniques pour un contre-anion de plus en plus hydrophobe. Cependant, l’échange inverse, soit vers des anions de plus en plus hydrophile, s’avère impossible. Toutefois, il a été observé par les travaux présentés dans ce mémoire, que les liquides ioniques immobilisés sur une surface d'or ont la capacité d'échanger leurs contre-anions réversiblement, procurant une méthode simple de moduler leurs propriétés physico-chimiques. Ce phénomène a été observé par la mesure d’angles de contacts et par les techniques spectroscopiques de l’infrarouge moyen (mid-IR), des photoélectrons de rayon-X (XPS) et par la diffusion Raman exaltée par les surfaces (SERS) ii ainsi que par la spectrométrie de masse (MS). La connaissance des propriétés d’échange d’anion est importante pour prédire le comportement de ces surfaces de liquides ioniques dans les tampons et fluides biologiques.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The aim of the thesis is to theoretically investigate optical/plasmonic antennas for biosensing applications. The full 3-D numerical electromagnetic simulations have been performed by using finite integration technique (FIT). The electromagnetic properties of surface plasmon polaritons (SPPs) and the localized surface plasmons (LSPs) based devices are studied for sensing purpose. The surface plasmon resonance (SPR) biosensors offer high refractive index sensitivity at a fixed wavelength but are not enough for the detection of low concentrations of molecules. It has been demonstrated that the sensitivity of SPR sensors can be increased by employing the transverse magneto-optic Kerr effect (TMOKE) in combination with SPPs. The sensor based on the phenomena of TMOKE and SPPs are known as magneto-optic SPR (MOSPR) sensors. The optimized MOSPR sensor is analyzed which provides 8 times higher sensitivity than the SPR sensor, which will be able to detect lower concentration of molecules. But, the range of the refractive index detection is limited, due to the rapid decay of the amplitude of the MOSPR-signal with the increase of the refractive indices. Whereas, LSPs based sensors can detect lower concentrations of molecules, but their sensitivity is small at a fixed wavelength. Therefore, another device configuration known as perfect plasmonic absorber (PPA) is investigated which is based on the phenomena of metal-insulator-metal (MIM) waveguide. The PPA consists of a periodic array of gold nanoparticles and a thick gold film separated by a dielectric spacer. The electromagnetic modes of the PPA system are analyzed for sensing purpose. The second order mode of the PPA at a fixed wavelength has been proposed for the first time for biosensing applications. The PPA based sensor combines the properties of the LSPR sensor and the SPR sensor, for example, it illustrates increment in sensitivity of the LSPR sensor comparable to the SPR and can detect lower concentration of molecules due to the presence of nanoparticles.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Die Wechselwirkungen zwischen Biomolekülen spielen eine zentrale Rolle in der biochemischen und pharmazeutischen Forschung. In der biomolekularen Interaktionsanalyse sind dabei Biosensoren auf Basis des Oberflächenplasmonresonanzeffekts (SPR-Effekt) weitverbreitet. Seit Einführung der ersten kommerziellen SPR-Biosensoren Anfang der 1990er Jahre wurden verschiedenste Messanordnungen sowie Materialsysteme mit dem Ziel einer möglichst hohen Empfindlichkeit getestet. Eine Möglichkeit zur Steigerung der Empfindlichkeit klassischer SPR-Systeme bieten sogenannte magneto-optische SPR-Biosensoren (MOSPR-Biosensoren). Grundlage der Empfindlichkeitssteigerung ist die gleichzeitige Messung des SPR-Effekts und des transversalen magneto-optischen KERR-Effekts (tMOKE). Bisherige Untersuchungen haben sich meist auf den Einfluss der Magnetisierung freier ferromagnetischer Schichten beschränkt. Im Rahmen dieser Arbeit wurden erstmals austauschverschobene Dünnschichtsysteme (EB-Systeme), eine Kombination aus Ferromagnet und Antiferromagnet, hinsichtlich ihrer Eignung für SPR- und MOSPR-basierte biosensorische Anwendungen untersucht. Aufgrund der remanenten Magnetisierung der ferromagnetischen Schicht und ihrer magnetischen Strukturierbarkeit sind EB-Systeme eine hochinteressante Plattform zur Realisierung neuer Biosensorkonzepte. Zur Reduzierung der stark dämpfendenden Wirkung magnetischer Materialien wurde das hier betrachtete IrMn/Co EB-System zwischen zwei Goldschichten eingebettet. Eine Gegenüberstellung optimierter Au/ IrMn/Co/Au-Systeme mit einem reinen Au-System, wie es typischerweise in kommerziellen SPR-basierten Biosensoren eingesetzt wird, demonstriert, dass mit den entwickelten EB-Systemen vergleichbare Empfindlichkeiten in SPR-Sensor-Anwendungen erreicht werden können. Die magneto-optische Aktivität der untersuchten Dünnschichtsysteme liegt im Bereich der Literaturwerte für Au/Co/Au-Systeme, mit denen erhöhte Empfindlichkeiten gegenüber Standard-SPR-Biosensoren realisiert wurden. Auf Grundlage magnetisch strukturierter Au/IrMn/Co/Au-Systeme wurden neue Biosensorkonzepte entwickelt und getestet. Erste Experimente belegen, dass mit diesen Schichtsystemen eine gleichzeitige Detektion der magnetisierungsabhängigen Reflektivitäten in ortsauflösenden MOSPR-Messungen möglich ist. Eine solche Messanordnung profitiert von der erhöhten Empfindlichkeit MOSPR-basierter Biosensoren, hohen Messgeschwindigkeiten und einem verbesserten Signal-Rausch-Verhältnis. Weiterhin wurde der domänenwandassistierte Transport (DOWMAT) superparamagnetischer Partikel über der Oberfläche eines exemplarischen EB-Systems, zur Sensorintegration von Misch-, Reinigungs- und Aufkonzentrationsfunktionen erfolgreich getestet. Die Ergebnisse demonstrieren, dass ein Transport von Partikelreihen mit hohen Geschwindigkeiten bei moderaten externen Magnetfeldern über den entwickelten Schichtsystemen möglich ist. Die Agglomeration der Partikel wird dabei intrinsisch vermieden. Diese Beobachtungen verdeutlichen die Vorzüge des DOWMAT-Mechanismus für biosensorische Anwendungen. Die präsentierten Untersuchungen bilden die Grundlage auf dem Weg zur Umsetzung neuer vielversprechender Biosensorkonzepte, die eine Schlüsselfunktion in der medizinischen point-of-care-Diagnostik bei der Detektion kleinster Konzentrationen krankheitsrelevanter Biomarker einnehmen können.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The control of morphology and coating of metal surfaces is essential for a number of organic electronic devices including photovoltaic cells and sensors. In this study, we monitor the functionalization of gold surfaces with 11-mercaptoundecanoic acid (MUA, HS(CH(2))(10)CO(2)H) and cysteamine, aiming at passivating the surfaces for application in surface plasmon resonance (SPR) biosensors. Using polarization-modulated infrared reflection-absorption spectroscopy (PM-IRRAS), cyclic voltammetry, atomic force microscopy and quartz crystal microbalance, we observed a time-dependent organization process of the adsorbed MUA monolayer with alkyl chains perpendicular to the gold surface. Such optimized condition for surface passivation was obtained with a systematic search for experimental parameters leading to the lowest electrochemical signal of the functionalized gold electrode. The ability to build supramolecular architectures was also confirmed by detecting with PM-IRRAS the adsorption of streptavidin on the MUA-functionalized gold. As the approaches used for surface functionalization and its verification with PM-IRRAS are generic, one may now envisage monitoring the fabrication of tailored electrodes for a variety of applications.