989 resultados para Order Determination
Resumo:
This paper describes 2 alternative methodologies for the determination of selected aldehydes (formaldehyde, acetaldehyde, propionaldehyde, acrolein, and benzaldehyde) by capillary electrophoresis (CE), the first approach is based on the formation of aldehyde-bisulfite adducts and employs free solution CE with reversed electroosmotic flow and indirect detection, using 10 mmol/L 3,5-dinitrobenzoic acid (pH 4.5) containing 0.2 mmol/L cetyltrimethylammonium bromide as the electrolyte. This novel methodology showed a fairly good sensitivity to concentration, with detection limits with respect to a single aldehyde on the order of 10-40 mu g/L, a reasonable analysis time (separation was achieved in <8 min), and no need for sample manipulation. A second approach was proposed in which 2,4-dinitrophenylhydrazine derivatives of the aldehydes were detected in a micellar electrolyte medium (20 mmol/L berate buffer containing 50 mmol/L sodium dodecyl sulfate and 15 mmol/L beta-cyclodextrin). This latter methodology included a laborious sample preconcentration step and showed much poorer sensitivity (0.5-2 mg/L detection limit, with respect to a single aldehyde), despite the use of sodium chloride to promote sample stacking. Both methodologies proved adequate to evaluate aldehyde levels in vehicular emissions. Samples from the tailpipe exhaust of a passenger car vehicle without a catalytic converter and operated with an ethanol-based fuel were collected and analyzed; the results showed high levels of formaldehyde and acetaldehyde (0.41-6.1 ppm, v/v). The concentrations estimated by the 2 methodologies, which were not in good agreement, suggest the possibility of striking differences in sample collection efficiency, which was not the concern of this work.
Resumo:
At accumulation potentials close to +0.1 V at a hanging mercury drop electrode, ceftazidime is accumulated at pH 9.5, probably in a hydrolysed or otherwise chemically altered form, in an anodic process to give an adsorbed mercury salt. The accumulation of this mercury salt allows the indirect cathodic-stripping voltammetric determination of ceftazidime using the reduction peak of the mercury salt at -0.70 V. The high sensitivity of the method coupled with high sample dilution allows ceftazidime to be determined in milk samples at the 28 mu g ml(-1) level without prior separation. In order to determine lower levels of ceftazidime in milk (ca. 10 ng ml(-1)) a separation process would be required. (C) 1998 Elsevier B.V. B.V. All rights reserved.
Resumo:
This work describes an efficient, fast, and reliable analytical methodology for mercury determination in urine samples using stripping chronopotentiometry at gold film electrodes. The samples were sonicated in the presence of concentrated HCl and H2O2 for 15 min in order to disrupt the organic ligands and release the mercury. Thirty samples can be treated over the optimized region of the ultrasonic bath. This sample preparation was enough to allow the accurate stripping chronopotentiometric determination of mercury in the treated samples. No background currents and no passivation of the gold film electrode due to the sample matrix were verified. The samples were also analyzed by cold vapour atomic absorption spectrometry (CV-AAS) and good agreement between the results was verified. The analysis of NIST SRM 2670 (Toxic Metals in Freeze-Dried Urine) also validated the proposed electroanalytical method. Finally, this method was applied for mercury evaluation in urine of workers exposed to hospital waste incinerators. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
In most of the cases, the systems of water distribution from groundwater wells use electrical submersible pumps. All electrical energy is applied to the pumps; however, other components (pipes, valves, etc.) of these systems are also responsible by the higher or lower consumption of electric energy. The supervisors and operators of the systems should thus have knowledge of the global energetic behavior of the process in order to administrate it properly. This work suggests a 'Global Energetic Efficiency Indicator' for groundwater wells by using mathematical equations and neural networks. Simulation results will be presented in order to demonstrate the validity of the proposed approach.
Resumo:
A flow injection system with online sample preparation is proposed for the determination of phosphite in liquid fertilizers by spectrophotometry. After loop-based injection, phosphite is oxidized by an acidic permanganate solution (1.0 10(-2) mol L-1 KMnO4 + 1.0 mol L-1 H2SO4) in a heated reactor (50 degreesC). The phosphate generated is then determined by the molybdenum blue method. Influence of flow rates, temperature, and concentration and order of addition of reagents, sample volume, and reactor configuration for the blue complex formation on recorded signals were investigated. The pow system was applied to phosphite determination in commercial samples of liquid fertilizers. The proposed system handles about 80 samples per hour [0.05-0.40% (w/v) H3PO3; R = 0,9998], consuming about 80 muL sample, 1 mg KMnO4, 25 mg (NH)(6)Mo7O24, and Ia mg ascorbic acid per determination. Results are precise [relative standard deviation less than or equal to 3.5% for 0.1% (w/v) H3PO3, n = 12] and in agreement with those obtained by gravimetry at 95% confidence level. (C) 2000 John Wiley & Sons, Inc.
Resumo:
This study investigated mechanisms involved in the maintenance of the functional response pattern of the postjunctional alpha(1)-adrenoceptor in vas deferens isolated from rats submitted to acute swimming stress. The plasma corticosterone levels increased approximately three times after the swimming stress in the nontreated rats as well as after swimming stress in the rats pretreated with desipramine (DMI), yohimbine (YO), or DMI with YO. No alteration was detected in the sensitivity to norepinephrine (NE) in the vasa deferentia from the stressed rats or stressed rats treated with DMI or DMI with YO, in relation to their respective control. However, when the vasa deferentia were previously incubated with DMI, a reduction in sensitivity to NE in organs from stressed rats was observed. Vasa deferentia excised from rats pretreated with YO before the swimming stress showed an increase in postjunctional alpha(1)-response that was abolished by prazosin (PZ). Thus, the neuronal uptake, the prejunctional alpha(2)-adrenoceptors (mediating prejunctional inhibition), the occupancy and functional response of the postjunctional alpha(1)-adrenoceptors, and the emotional stress component were very important for the determination of the noradrenergic response pattern in vas deferens from rats submitted to acute swimming stress. (C) 2002 Elsevier B.V. Ltd. All rights reserved.
Resumo:
A simple and sensitive method for determining atmospheric ammonia (NH3), using a hanging drop, is described. A colorimetric sensor is composed of two optical fibers and the source of monochromatic light implemented was a red light emitting diode (LED) (635 nm). Preliminary experiments were carried out in order to optimize the geometry of the sensor. These tests showed that the best signal absorbance was obtained using a 22 muL deionized water drop for sampling the gas and as addition of 4 muL of each of the reactants to form the blue dye (indophenol). Some important analytical parameters were also studied, including sampling time and flow rate. The analytical curve was constructed with a concentration range of 3-20 ppbv of gaseous NH3 standard. The detection limit reached was of ca 0.5 ppbv. It was observed that formaldehyde and diethylamine did not interfere. However, studies showed that hydrogen sulfide caused a negative interference of 20%, when present in the atmosphere in a concentration equal to that of NE3. The method considered here was shown to be easy to apply, making it possible to make a determination every 17 min.
Resumo:
The present article presents a means of determining the maximum impact force between two bodies from the determination of the involved impulse in the impact and the sound emitted by the shock of the bodies during this impact.It also presents a case study applied to the shock between the skulls of male sheep of the Ovis aries species. These animals do not possess horns and dispute the territorial leadership by fighting, during which the skull is used as a weapon of attack, similar to a battering ram.Initially, a revision of basic physics approaching the theory of impulse is made, which shows that the average force during an impact can be obtained by the quantity of movement of the bodies. In its turn, the quantity of movement is obtained through the average speed of approach and the mass of the bodies. The maximum force is obtained from the average force, using the approach of the Force X Time curve with the Sonorous Intensity X Time Curve.In order to study the case of a shock between two sheep, the mass of the bodies was obtained through direct weighing and the average speed of approach obtained indirectly through filming, thus making possible the calculation of the average force. The Sonorous Intensity X Time Curve was obtained through the recording of the sound of the impact during a filmed fight, with later manipulation through computer programs. With this data the maximum force exercised between the skull of the sheep during the impact was obtained, which will be used in later studies.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Different kinds of modifiers and coatings on the integrated platform of transversely heated graphite atomizer (THGA) have been tested for the simultaneous determination of two group of elements: the first, the more volatile, formed by arsenic, bismuth, lead, antimony and selenium; the second, the less volatile, formed by cobalt, chromium, cupper, iron and manganese in milk by electrothermal atomic absorption spectrometry. Different Rh-modifiers were studied, such as Rh-coated platforms (Rh), carbide plus rhodium coated platforms (W-Rh, Zr-Rh), carbide-coated platforms (W and Zr) with co-injection of RhCl3, solutions and uncoated platforms with injection of solutions of Pd(NO3)(2), Mg(NO3)(2), and RhCl3. Milk samples were diluted 1:10 in 1.0% HNO3 and injected into the tube. The mass of modifier deposited and co-injected in the tube and the use of end capped tubes were also evaluated in order to improve the electrothermal behavior of analytes. Integrated platform pretreated with W plus co-injection RhCl3 for first group and pretreated with W-Rh for second group were elected. For 20 mu L injected samples the analytical curves in the 5.0-20.0 mu g L-1 concentration range have good linear correlation coefficients (r > 0.998). Relative standard deviations (n = 12) are < 6% and the calculated characteristic masses are between 5 pg and 62 pg.
Resumo:
A calibration method was developed using flow injection analysis (FI) with a Gradient Calibration Method (GCM). The method allows the rapid determination of zinc In foods (approximately 30 min) after treatment with concentrated sulphuric acid and 30% hydrogen peroxide, and analysis with flame atomic absorption spectrometry (FAAS). The method provides analytical results with a relative standard deviation of about 2% and requires less time than by conventional FI calibration. The electronic selection of different segments along the gradient and monitoring of the technique covers wide concentration ranges while maintaining the inherent high precision of flow injection analysis. Concentrations, flow rates, and flow times of the reagents were optimized in order to obtain best accuracy and precision. Flow rates of 10 mL/min were selected for zinc. In addition, the system enables electronic dilution and calibration where a multipoint curve can be constructed using a single sample injection.
Resumo:
This paper presents models that can be used in the design of microstrip antennas for mobile communications. The antennas can be triangular or rectangular. The presented models are compared with deterministic and empirical models based on artificial neural networks (ANN) presented in the literature. The models are based on Perceptron Multilayer (PML) and Radial Basis Function (RBF) ANN. RBF based models presented the best results. Also, the models can be embedded in CAD systems, in order to design microstrip antennas for mobile communications.
Resumo:
This work proposes a new method to determine the chemical composition of magnetic ferrite nanoparticles by the slurry injection technique using the inductively coupled plasma optical emission spectroscopy. In this way, experimental conditions such as aerosol gas flow rate and colloidal stability were optimized in order to use aqueous calibration curves in the slurry nebulization and to determine the chemical composition of a series of sols containing chemically synthesized size-tailored NiFe 2O 4 nanograms. Then, the results of direct sampling and those of conventional aqueous introduction analysis are compared, showing the efficiency of the proposed method.
Resumo:
In this article, the authors measure throughput of sonic diamond microtubes and micronozzles that can work as passive gas flow controllers and flow meters under choking conditions. The behavior of the outlet pressure through the microdevices using an experimental setup with constant volume and constant temperature was determined in order to obtain the critical throughput, the critical mass flow rate, and the discharge coefficients of the diamond sonic microdevices. © 2007 American Vacuum Society.
Resumo:
It is well known that the microcrack density is a fundamental parameter in hard chromium electroplating. The chemical and mechanical properties of this coating are widely dependent on its microcrack density. In this paper a simple image analysis procedure to determine microcrack density is presented in order to demonstrate it as a fundamental tool to estimate the fatigue, corrosion and wear behavior, as well as the residual stress field of a coated component. For this purpose, the image analysis procedure was carried out on two kinds of hard chromium plating - one called accelerated (high velocity of deposition and fluoride-free) and the other conventional (with fluoride). The coatings were applied on samples of AISI 4340 aeronautical steel, which is widely used in aircraft landing gear components. To characterize the practical significance of this study, the microcrack density results were related to the fatigue, wear and corrosion behavior from previous study and to the residual stress field in the coatings.