985 resultados para Orbital Maneuvers
Resumo:
In this work is presented a new method for the determination of the orbital period (Porb) of eclipsing binary systems based on the wavelet technique. This method is applied on 18 eclipsing binary systems detected by the CoRoT (Convection Rotation and planetary transits) satellite. The periods obtained by wavelet were compared with those obtained by the conventional methods: box Fitting (EEBLS) for detached and semi-detached eclipsing binaries; and polynomial methods (ANOVA) for contact binary systems. Comparing the phase diagrams obtained by the different techniques the wavelet method determine better Porb compared with EEBLS. In the case of contact binary systems the wavelet method shows most of the times better results than the ANOVA method but when the number of data per orbital cicle is small ANOVA gives more accurate results. Thus, the wavelet technique seems to be a great tool for the analysis of data with the quality and precision given by CoRoT and the incoming photometric missions.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
In this work, three welding programs for orbital TIG previously developed were used, using pulsed current and increasing speed (M), constant current (#B) and pulsed current and decreasing current (#C). One of those should be used for the propulsion system of the satellite CBERS (CHINA-BRAZIL EARTH RESOURCES SATELLITE). Welded joints using tubes of commercially pure titanium were obtained with these procedures, which were characterized by means of mechanical and metallographic tests. The obtained results show that the three welding procedures produce welded joints free of defects and with adequate shape. Although small differences on mechanical properties and microstructure have been observed, the three welding programs attained compatible results with international standards used in the aerospace segment. The welding program #B, due the reduced heat input used, was considered to obtain slightly advantage over the others.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Objetivo: Relatar 20 pacientes portadores de dermolipoma e 10 pacientes com prolapso de gordura orbitária, ressaltando aspectos que podem auxiliar para o diferencial clínico destas duas entidades. Métodos: Foi realizado estudo retrospectivo de 12 anos, avaliando-se portadores de dermolipoma e de prolapso de gordura orbitária, atendidos na Faculdade de Medicina de Botucatu-SP. Resultados: No período foram detectados 20 (1,6 pacientes/ano) portadores de dermolipoma e 10 (0,8 pacientes/ano), de prolapso de gordura orbitária. Quanto ao sexo, o dermolipoma acometeu mais mulheres e o prolapso de gordura orbital ocorreu mais em homens. Nos portadores de dermolipoma, a lesão foi encontrada no canto externo em todos os pacientes, sendo bilateral em apenas um caso; nos com prolapso de gordura orbital, a lesão localizava-se no canto externo em 9 dos 10 portadores. Sete pacientes com dermolipoma possuíam associação com outras doenças oculares e em dez pacientes a lesão estava presente desde o nascimento. Conclusão: O dermolipoma é semelhante ao prolapso de gordura orbitária quanto à localização e aparência clínica. Porém, o dermolipoma está presente desde o nascimento, ocorre mais no sexo feminino, podendo estar associado a outras doenças oculares. O prolapso de gordura orbitária é alteração que ocorre em indivíduos idosos, geralmente do sexo masculino.
Resumo:
Background: An experimental study was done to assess the ability of the vegetal polymer miniplates and screws to repair defects of the orbital floor.Methods: An artificial standard-sized defect was created in the bony floor of right orbit of 45 albino rabbits. The animals were divided into three experimental groups: control group (G1) involving animals with orbital floor defect and no treatment; titanium group (G2) containing animals with orbital floor defect repaired by titanium miniplates and screws; vegetal polymer group (G3) composed of animals with similar orbital floor defects repaired by vegetal polymer miniplates and screws. Throughout the course of the experiment, the animals were clinically evaluated. At 15, 30 and 60 days after surgery, the animals were killed. They were X-rayed immediately after the floor defect and at the moment of sacrifice. Histological and morphometric evaluation of inflammatory reaction and bone healing was done. Data were statistically evaluated.Results: No implants were extruded. Bone consolidation was similar in G2 and G3 and better than in G1 group animals. Inflammatory reaction was most pronounced in animals of G3 15 days after surgery, and it subsided over time.Conclusion: Vegetal polymer miniplates and screws induces small inflammatory reaction and had the ability to stimulate bone growth with good integration in the orbital floor defect allowing to consider the vegetal polymer adequate option to treat orbital floor defects. Future studies involving long-term follow-up and biomechanical tests to evaluate material resistance to traction are needed.
Resumo:
Background: Solitary fibrous tumor (SFT) is a rare, benign, and very uncommon lesion in the orbit. Because of its complex and variable clinical and histological appearance the SIFT is often misdiagnosed.Cases: Two new cases of orbital SIFT are reported, one in a man and the other in a woman, both unilateral and in the superomedial orbit.Observations: Clinical and tomographical evaluations were conducted and the lesions were excised. The histological evaluation showed the tumors were composed of spindle-shaped cells within colla.-en bundles and vascular channels. Immunohistochemical staining was positive for CD 34 and negative for S-100 protein.Conclusion: Immunohistochemical study is an important adjuvant in determining the SIFT diagnosis. Long-term follow-up is necessary because of the possibility of SFT recurrence after excision. (C) 2003 Japanese Ophthalmological Society.
Resumo:
The objectives of this study were, through a literature review, to point the differences between orbital implants and their advantages and disadvantages, to evaluate prosthesis motility after orbital implants are inserted, and to point the implant wrapping current risks. Sixty-seven articles were reviewed. Enucleation implants can be autoplastics or alloplastics and porous (including natural and synthetic hydroxyapatite [HA]) or nonporous (silicone). Hydroxyapatite is the most related in the literature, but it has disadvantages, too, that is, all orbital implants must be wrapped. Exposure of the porous orbital implant can be repaired using different materials, which include homologous tissue, as well as autogenous graft, xenograft, and synthetic material mesh. The most used materials are HA and porous polyethylene orbital implant. The HA implant is expensive and possibly subject corals to damage, different from porous polyethylene orbital implants. Porous implants show the best prosthesis motility and a minimum rate of implants extrusion. Implant wraps can facilitate smoother entry of the implant into the orbit and allow reattachment of extraocular muscles. They also serve as a barrier between the overlying soft tissue and the rough surface of the implant, protecting implants from exposure or erosion.
Resumo:
One of the concerns after a major trauma to the orbit is to be rebuilt. This can be achieved with care in management of orbital reconstruction, techniques, types of materials, and osseointegrated implants; it allows satisfactory aesthetic recuperation and well-being, whereas psychological therapy allows for patients' re-insertion in social and family environment to make them feel happier and safer.
Resumo:
Aims. We study trajectories of planetesimals whose orbits decay due to gas drag in a primordial solar nebula and are perturbed by the gravity of the secondary body on an eccentric orbit whose mass ratio takes values from mu(2) = 10(-7) to mu(2) = 10(-3) increasing ten times at each step. Each planetesimal ultimately suffers one of the three possible fates: (1) trapping in a mean motion resonance with the secondary body; (2) collision with the secondary body and consequent increase of its mass; or (3) diffusion after crossing the orbit of the secondary body.Methods. We take the Burlirsh-Stoer numerical algorithm in order to integrate the Newtonian equations of the planar, elliptical restricted three-body problem with the secondary body and the planetesimal orbiting the primary. It is assumed that there is no interaction among planetesimals, and also that the gas does not affect the orbit of the secondary body.Results. The results show that the optimal value of the gas drag constant k for the 1: 1 resonance is between 0.9 and 1.25, representing a meter size planetesimal for each AU of orbital radius. In this study, the conditions of the gas drag are such that in theory, L4 no longer exists in the circular case for a critical value of k that defines a limit size of the planetesimal, but for a secondary body with an eccentricity larger than 0.05 when mu(2) = 10(-6), it reappears. The decrease of the cutoff collision radius increase the difusions but does not affect the distribution of trapping. The contribution to the mass accretion of the secondary body is over 40% with a collision radius 0.05R(Hill) and less than 15% with 0.005R(Hill) for mu(2) = 10(-7). The trappings no longer occur when the drag constant k reachs 30. That means that the size limit of planetesimal trapping is 0.2 m per AU of orbital radius. In most cases, this accretion occurs for a weak gas drag and small secondary eccentricity. The diffusions represent most of the simulations showing that gas drag is an efficient process in scattering planetesimals and that the trapping of planetesimals in the 1: 1 resonance is a less probable fate. These results depend on the specific drag force chosen.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)