900 resultados para Ontogenetic Shift
Resumo:
The aim of this study was to compare statistically the zooplankton assemblage ingested by brown trout (Salmo trutta) in Loch Ness with that of the zooplankton in the water column. This would allow the examination of the apparent paradox that very few copepods appear to be consumed by trout at a time of year when they are numerous and readily available as food. The investigation was limited to the crustacean zooplankters, since the Rotifera are generally so small that they are only of interest to fish in the first few days of life. 25 trout were obtained from anglers, and the stomach contents of non-"ferox" animals analysed. Samples of pelagic zooplankton were obtained approximately monthly from 30-m vertical net-hauls (mesh size 100 km). It is concluded that the variation in dietary composition with trout wet weight indicates an ontogenetic habitat shift producing spatial separation of young and older individuals.
Resumo:
It is the first time in China that the phase variations and phase shift of microwave cavity in a miniature Rb fountain frequency standard are studied, considering the effect of imperfect metallic walls. Wall losses in the microwave cavity lead to small traveling wave components that deliver power from the cavity feed to the walls of cavity. The small traveling wave components produce a microradian distribution of phase throughout the cavity ity, and therefore distributed cavity phase shifts need to be considered. The microwave cavity is a TE011 circular cylinder copper cavity, with round cut-hole of end plates (14mm in diameter) for access for the atomic flux and two small apertures in the center of the side wall for coupling in microwave power. After attenuation alpha is calculated, field variations in cavity are solved. The field variations of the cavity are given. At the same time, the influences of loaded quality factor QL and diameter/height (2a/d) of the microwave cavity on the phase variations and phase shift are considered. According to the phase variation and phase shift of microwave cavity we select the parameters of cavity, diameter 2a = 69.2mm, height d = 34.6mm, QL = 5000, which will result in an uncertainty delta(Delta f / f0 ) < 4.7 x 10(-17) and meets the requirement for the miniature Rb fountain frequency standard with accuracy 10(-15).
Resumo:
We have theoretically investigated the phase shift of a probe field for a four-level atomic system interacting successively with two fields tuned near an EIT resonance of an atom, a microwave field, and a coupling field. It has been found that the phase of retrieved signal has been shifted due to the cross-phase modulation when the stored spin wave was disturbed by a microwave. Because of the low relaxation rates of the ground hyperfine state, our proposed technique can impart a large phase rotation onto the probe field with low absorption of retrieved field and very low intensity of the microwave field.
Resumo:
This paper investigates the influences of phase shift on superresolution performances of annular filters. Firstly, it investigates the influence of phase shift on axial superresolution. It proves theoretically that axial superresolution can not be obtained by two-zone phase filter with phase shift pi, and it gets the phase shift with which axial superresolution can be brought by two-zone phase filter. Secondly, it studies the influence of phase shift on transverse superresolution. It finds that the three-zone phase filter with arbitrary phase shift has an almost equal optimal transverse gain to that of commonly used three-zone phase filter, but can produce a much higher axial superresolution gain. Thirdly, it investigates the influence of phase shift on three-dimensional superresolution. Three-dimensional superresolution capability and design margin of three-zone complex filter with arbitrary phase shift are obtained, which presents the theoretical basis for three-dimensional superresolution design. Finally, it investigates the influence of phase shift on focal shift. To obtain desired focal shifts, it designs a series of three-zone phase filters with different phase shifts. A spatial light modulator (SLM) is used to implement the designed filters. By regulating the voltage imposed on the SLM, an accurate focal shift control is obtained.
Resumo:
A novel phase-step calibration technique is presented on the basis of a two-run-times-two-frame phase-shift method. First the symmetry factor M is defined to describe the distribution property of the distorted phase due to phase-shifter miscalibration; then the phase-step calibration technique, in which two sets of two interferograms with a straight fringe pattern are recorded and the phase step is obtained by calculating M of the wrapped phase map, is developed. With this technique, a good mirror is required, but no uniform illumination is needed and no complex mathematical operation is involved. This technique can be carried out in situ and is applicable to any phase shifter, whether linear or nonlinear. (c) 2006 Optical Society of America.
Resumo:
In this paper an electrically controllable radial birefringent pupil filter is proposed. It consists of two polarizers and an improved electrically controllable optical azimuth rotator which has two lambda/4 retarders, one electro-optical crystal and one radial birefringent crystal. The evolution and distribution of polarization states of this pupil filter are discussed. The most interesting and useful advantage of such a structure is that the characteristic of transverse superresolution and axial extended focal depth or focal shift can be obtained merely by controlling the applied voltage on the electro-optical crystal. The radial birefringent crystal azimuth angle cooperating with different electrical inductive phase differences will determine the transverse and axial intensity distribution. It is shown that for particular ranges of electrical inductive phase difference it is possible to obtain transverse superresolution along with extended focal depth or with a focal shift.
Resumo:
A four-frame phase shift method and an associated algorithm using unequal phase steps are presented. The unique advantage of this method is that it becomes insensitive to phase shifter nonlinearity because of the performance of a special procedure, in which the phase shifts are shared out between the reference beam and the object beam. By this means, any phase shifter can work as long as one phase shift is accurately known. On the basis of the technique, a simple calibration method for the linear phase shifter is suggested. The influences of phase shifter miscalibration, detector nonlinearity and random noise on the algorithm are investigated, and the optimal phase shifts are given.
Resumo:
Electronic Kαl x-ray isotope shifts have been measured for Sn 116-124, Sm 148-154, W 182-184, W 184-186, and W 182-186 using a curved crystal Cauchois spectrometer. The analysis of the measurements has included the electrostatic volume effect, screening by the transition electron as well as the non-transition electrons, normal and specific mass shifts, dynamical nuclear qudrupole polarization, and a radiative correction effect of the electron magnetic moment in the nuclear charge radii are obtained. Where other experimental data are available, the agreement with the present measurements is satisfactory. Comparisons with several nuclear model predictions yield only partial agreement.
Resumo:
Part I
Potassium bis-(tricyanovinyl) amine, K+N[C(CN)=C(CN)2]2-, crystallizes in the monoclinic system with the space group Cc and lattice constants, a = 13.346 ± 0.003 Å, c = 8.992 ± 0.003 Å, B = 114.42 ± 0.02°, and Z = 4. Three dimensional intensity data were collected by layers perpendicular to b* and c* axes. The crystal structure was refined by the least squares method with anisotropic temperature factor to an R value of 0.064.
The average carbon-carbon and carbon-nitrogen bond distances in –C-CΞN are 1.441 ± 0.016 Å and 1.146 ± 0.014 Å respectively. The bis-(tricyanovinyl) amine anion is approximately planar. The coordination number of the potassium ion is eight with bond distances from 2.890 Å to 3.408 Å. The bond angle C-N-C of the amine nitrogen is 132.4 ± 1.9°. Among six cyano groups in the molecule, two of them are bent by what appear to be significant amounts (5.0° and 7.2°). The remaining four are linear within the experimental error. The bending can probably be explained by molecular packing forces in the crystals.
Part II
The nuclear magnetic resonance of 81Br and 127I in aqueous solutions were studied. The cation-halide ion interactions were studied by studying the effect of the Li+, Na+, K+, Mg++, Cs+ upon the line width of the halide ions. The solvent-halide ion interactions were studied by studying the effects of methanol, acetonitrile, and acetone upon the line width of 81Br and 127I in the aqueous solutions. It was found that the viscosity plays a very important role upon the halide ions line width. There is no specific cation-halide ion interaction for those ions such as Mg++, Di+, Na+, and K+, whereas the Cs+ - halide ion interaction is strong. The effect of organic solvents upon the halide ion line width in aqueous solutions is in the order acetone ˃ acetonitrile ˃ methanol. It is suggested that halide ions do form some stable complex with the solvent molecules and the reason Cs+ can replace one of the ligands in the solvent-halide ion complex.
Part III
An unusually large isotope effect on the bridge hydrogen chemical shift of the enol form of pentanedione-2, 4(acetylacetone) and 3-methylpentanedione-2, 4 has been observed. An attempt has been made to interpret this effect. It is suggested from the deuterium isotope effect studies, temperature dependence of the bridge hydrogen chemical shift studies, IR studies in the OH, OD, and C=O stretch regions, and the HMO calculations, that there may probably be two structures for the enol form of acetylacetone. The difference between these two structures arises mainly from the electronic structure of the π-system. The relative population of these two structures at various temperatures for normal acetylacetone and at room temperature for the deuterated acetylacetone were calculated.
Resumo:
Isotope shifts of Kα1 x-ray transitions were measured for the Neodymium isotopes Nd 142, 143, 144, 145, 146, 148 and 150, the Samarium isotopes Sm 147, 148, 149, 150, 152 and 154, the Gadolinium isotopes Gd 154, 155, 156, 157, 158 and 160, the Dysprosium isotopes Dy 162 and 164, the Erbium isotopes Er 166, 168 and 170, the Hafnium isotopes Hf 178 and 180 and the Lead isotopes Pb 204, 206, 207 and 208. A curved crystal Cauchois spectrometer was used. The analysis of the measurement furnished the variation of the mean square charge radius of the nucleus, δ˂r2˃, for 23 isotope pairs. The experimental results were compared with theoretical values from nuclear models. Combining the x-ray shifts and the optical shifts in Nd and Sm yielded the optical mass shifts. An anomaly was observed in the odd-even shifts when the optical and the x-ray shifts were plotted against each other.
Resumo:
In this paper, the evolution of the gradient force pattern, focal shift, and focal switch induced by a three-portion pure phase-shifting apodizer is numerically investigated in detail. The results show that the proposed apodizer may induce tunable gradient force on the particles in the focal region, focal shift, and focal switch. By adjusting the geometrical parameters of the phase-shifting apodizer, multiple traps may occur with changeable distance between them, and the shape of the optical trap also evolves evidently. More interestingly, for certain geometrical parameters of the proposed apodizer, by changing the phase shift of inner annular portion, the considerable focal shift may occur with focal switch accompanying, which is discussed to show that this kind of apodizer may be a very promising method of transporting trapped particles. © 2005 Elsevier GmbH. All rights reserved.