991 resultados para Obstetric Complication
Resumo:
The objective of this systematic review was to assess the 5- and 10-year survival of implant-supported fixed dental prostheses (FDPs) and to describe the incidence of biological and technical complications.
Resumo:
Upshaw-Schulman syndrome (USS) is a rarely reported congenital form of thrombotic thrombocytopenic purpura (TTP) that results from mutations in the ADAMTS13 gene. Many USS patients are diagnosed during the second or third trimester of their first pregnancy. We present a patient diagnosed with USS following retinal detachments and intrauterine fetal demise at 34 weeks of gestation. The patient's plasma was tested for ADAMTS13 activity, inhibitor, and antibody. Subsequently, she and her first-degree relatives had ADAMTS13 gene sequencing. Initially, the patient was found to have an ADAMTS13 activity of <5% in the absence of an ADAMTS13 inhibitor (FRETS assay) or antibody (immunoassay). Repeat studies in the months following hospital discharge showed persistent, undetectable ADAMTS13 activity and she was given a clinical diagnosis of USS. Molecular sequencing demonstrated two novel missense mutations in the ADAMTS13 gene: one in the maternal exon 17 (p.Ala690Thr due to nucleotide substitution c.2068 G>A) and another in the paternal exon 22 (p.Arg915Cys due to nucleotide substitution c.2746 C>T). In addition to being compound heterozygous for two ADAMTS13 mutations, the patient also had two maternally inherited single nucleotide polymorphisms: p.P618A (exon 16) and p.A732V (exon 18). Her parents and only sister had normal or near-normal ADAMTS13 activity. Each was heterozygous for one of the novel missense mutations. This case highlights the importance of molecular analysis of the ADAMTS13 gene in patients and family members when the severe ADAMTS13 deficiency does not appear to be autoimmune in nature. J. Clin. Apheresis, 2012. © 2012 Wiley Periodicals, Inc.
Resumo:
To assess the 5-year survival rates and incidences of complications of cemented and screw-retained implant reconstructions.
Resumo:
PURPOSE: To evaluate selective and superselective catheter therapy of serious arterial damage associated with orthopedic surgery of the pelvis, hip joint, femur, and knee. MATERIALS AND METHODS: Between 1989 and 2005, 16 consecutive patients with arterial damage after orthopedic surgery (seven women, nine men; mean age, 62 years; age range, 21-82 y) underwent angiographic exploration. Seven patients were in hemodynamically unstable condition. Initial orthopedic procedures were iliac crest internal fixation (n = 1); total hip prosthesis (n = 3); revision of total hip prosthesis (n = 4); revision of acetabular cup prosthesis (n = 1); gamma-nailing, nail-plate fixation, or intramedullary nailing (n = 3); and total knee prosthesis (n = 4). RESULTS: Angiography showed pseudoaneurysms (n = 11), vascular lacerations with active extravasation (n = 3), and arteriovenous fistulas with extravasation (n = 2). After angiographic documentation of serious arterial injury, 14 patients were treated with a single or coaxial catheter technique in combination with coils alone, coils and polyvinyl alcohol particles, coils and Gelfoam pledgets, or Gelfoam pledgets; or balloon occlusion with isobutyl cyanoacrylate and coils. Two patients were treated with covered stents. In all, bleeding was effectively controlled in a single session in 16 patients, with immediate circulatory stabilization. Major complications included death, pulmonary embolism, and postprocedural hematoma. CONCLUSION: Selective and superselective catheter therapy may be used for effective, minimally invasive management of rare but potentially life-threatening vascular complications after orthopedic surgery.
Resumo:
OBJECTIVES: The objectives of this systematic review were to assess the 5-year survival of resin-bonded bridges (RBBs) and to describe the incidence of technical and biological complications. METHODS: An electronic Medline search complemented by manual searching was conducted to identify prospective and retrospective cohort studies on RBBs with a mean follow-up time of at least 5 years. Patients had to have been examined clinically at the follow-up visit. Assessment of the identified studies and data extraction were performed independently by two reviewers. Failure and complication rates were analyzed using random-effects Poissons regression models to obtain summary estimates of 5-year proportions. RESULTS: The search provided 6110 titles and 214 abstracts. Full-text analysis was performed for 93 articles, resulting in 17 studies that met the inclusion criteria. Meta-analysis of these studies indicated an estimated survival of RBBs of 87.7% (95% confidence interval (CI): 81.6-91.9%) after 5 years. The most frequent complication was debonding (loss of retention), which occurred in 19.2% (95% CI: 13.8-26.3%) of RBBs over an observation period of 5 years. The annual debonding rate for RBBs placed on posterior teeth (5.03%) tended to be higher than that for anterior-placed RBBs (3.05%). This difference, however, did not reach statistical significance (P=0.157). Biological complications, like caries on abutments and RBBs lost due to periodontitis, occurred in 1.5% of abutments and 2.1% of RBBs, respectively. CONCLUSION: Despite the high survival rate of RBBs, technical complications like debonding are frequent. This in turn means that a substantial amount of extra chair time may be needed following the incorporation of RBBs. There is thus an urgent need for studies with a follow-up time of 10 years or more, to evaluate the long-term outcomes.
A systematic review of the 5-year survival and complication rates of implant-supported single crowns
Resumo:
OBJECTIVES: The objective of this systematic review was to assess the 5-year survival of implant-supported single crowns (SCs) and to describe the incidence of biological and technical complications. METHODS: An electronic MEDLINE search complemented by manual searching was conducted to identify prospective and retrospective cohort studies on SCs with a mean follow-up time of at least 5 years. Failure and complication rates were analyzed using random-effects Poisson's regression models to obtain summary estimates of 5-year proportions. RESULTS: Twenty-six studies from an initial yield of 3601 titles were finally selected and data were extracted. In a meta-analysis of these studies, survival of implants supporting SCs was 96.8% [95% confidence interval (CI): 95.9-97.6%] after 5 years. The survival rate of SCs supported by implants was 94.5% (95% CI: 92.5-95.9%) after 5 years of function. The survival rate of metal-ceramic crowns, 95.4% (95% CI: 93.6-96.7%), was significantly (P=0.005) higher than the survival rate, 91.2% (95% CI: 86.8-94.2%), of all-ceramic crowns. Peri-implantitis and soft tissue complications occurred adjacent to 9.7% of the SCs and 6.3% of the implants had bone loss exceeding 2 mm over the 5-year observation period. The cumulative incidence of implant fractures after 5 years was 0.14%. After 5 years, the cumulative incidence of screw or abutment loosening was 12.7% and 0.35% for screw or abutment fracture. For supra-structure-related complications, the cumulative incidence of ceramic or veneer fractures was 4.5%. CONCLUSION: It can be concluded that after an observation period of 5 years, high survival rates for implants and implant-supported SCs can be expected. However, biological and particularly technical complications are frequent.
Resumo:
We report of a 71-year-old woman with a history of chronic analgesic nephropathy, who underwent coronary angiography. Because of anterior ventricular aneurysm, anticoagulation with nadroparine was installed. Continued ACE-inhibitor and ASA with additional intravenous contrast substance lead to acute tubular necrosis with rapid decline of the renal function. Due to accumulation of the low molecular weight heparin, the patient developed an extensive retroperitoneal haematoma with circulatory shock and temporary anuric kidney failure. Low molecular weight heparins are commonly used during percutaneous coronary interventions. They are as safe and efficient compared to unfractioned heparin. But due to their renal elimination, they have to be monitored by measuring anti-factor Xa-activity if creatinine-clearance is <30 ml/min.
Resumo:
BACKGROUND AND PURPOSE: Although mechanical thrombectomy (MT) has an encouragingly high recanalization rate in treating stroke, it is associated with severe complications of which the underlying factors have yet to be identified. Because MT is a mechanical approach, the mechanical properties of the thrombus might be crucial for its success. The present study assesses the effect of thrombus length on the in vivo effectiveness and complication rate of MT. MATERIALS AND METHODS: Angiography and embolization of 21 cranial vessels with radiopaque whole-blood thrombi 10, 20, and 40 mm in length (7 occlusions each) were performed in 7 swine. MT was carried out using a distal snarelike device (BCR Roadsaver) with proximal balloon occlusion. A total of 61 retrievals were attempted. RESULTS: In the group of 10-mm occlusions, 77.8% of the attempts achieved complete recanalisation. For longer occlusions, the success rates decreased significantly to 20% of attempts for 20-mm occlusions (odds ratio [OR], 14; 95% confidence interval [CI], 2.2-89.2) and 11.1% for 40-mm occlusions (OR, 28; 95% CI, 3.9-202.2; P < .005). The low success rates were largely due to complications associated with thrombus compaction during retrieval. Similarly, the rate of thromboembolic events increased from 0% in 10-mm occlusions to 14.8% in 40-mm occlusions. CONCLUSIONS: MT using a distal device proved to be a fast, effective, and safe procedure for recanalizing short (10-mm) occlusions in the animal model. However, occlusion length emerged as a crucial determinant for MT with a significant decrease in recanalization success per attempt and increased complication rates. These findings suggest limitations of MT in the clinical application.