987 resultados para New left
Resumo:
In three-dimensional (3D) coronary magnetic resonance angiography (MRA), the in-flow contrast between the coronary blood and the surrounding myocardium is attenuated as compared to thin-slab two-dimensional (2D) techniques. The application of a gadolinium (Gd)-based intravascular contrast agent may provide an additional source of signal and contrast by reducing T(1blood) and supporting the visualization of more distal or branching segments of the coronary arterial tree. In six healthy adults, the left coronary artery (LCA) system was imaged pre- and postcontrast with a 0.075-mmol/kg bodyweight dose of the intravascular contrast agent B-22956. For imaging, an optimized free-breathing, navigator-gated and -corrected 3D inversion recovery (IR) sequence was used. For comparison, state-of-the-art baseline 3D coronary MRA with T(2) preparation for non-exogenous contrast enhancement was acquired. The combination of IR 3D coronary MRA, sophisticated navigator technology, and B-22956 allowed for an extensive visualization of the LCA system. Postcontrast, a significant increase in both the signal-to-noise ratio (SNR; 46%, P < 0.05) and contrast-to-noise ratio (CNR; 160%, P < 0.01) was observed, while vessel sharpness of the left anterior descending (LAD) artery and the left coronary circumflex (LCX) were improved by 20% (P < 0.05) and 18% (P < 0.05), respectively.
Resumo:
OBJECTIVE: Resistin is associated with inflammation and insulin resistance and exerts direct effects on myocardial cells including hypertrophy and altered contraction. We investigated the association of serum resistin concentrations with risk for incident heart failure (HF) in humans. METHODS AND RESULTS: We studied 2902 older persons without prevalent HF (age, 73.6+/-2.9 years; 48.1% men; 58.8% white) enrolled in the Health, Aging, and Body Composition (Health ABC) Study. Correlation between baseline serum resistin concentrations (20.3+/-10.0 ng/mL) and clinical variables, biochemistry panel, markers of inflammation and insulin resistance, adipocytokines, and measures of adiposity was weak (all rho <0.25). During a median follow-up of 9.4 years, 341 participants (11.8%) developed HF. Resistin was strongly associated with risk for incident HF in Cox proportional hazards models controlling for clinical variables, biomarkers, and measures of adiposity (HR, 1.15 per 10.0 ng/mL in adjusted model; 95% CI, 1.05 to 1.27; P=0.003). Results were comparable across sex, race, diabetes mellitus, and prevalent and incident coronary heart disease subgroups. In participants with available left ventricular ejection fraction at HF diagnosis (265 of 341; 77.7%), association of resistin with HF risk was comparable for cases with reduced versus preserved ejection fraction. CONCLUSIONS: Serum resistin concentrations are independently associated with risk for incident HF in older persons.
Resumo:
OBJECTIVE: Fabry disease is an X-linked disorder resulting from alpha-galactosidase A deficiency. The cardiovascular findings include left ventricular hypertrophy (LVH) and increased intima-media thickness of the common carotid artery (CCA IMT). The current study examined the possible correlation between these parameters. To corroborate these clinical findings in vitro, plasma from Fabry patients was tested for possible proliferative effect on rat vascular smooth muscle cells (vascular smooth muscle cell [VSMC]) and mouse neonatal cardiomyocytes. METHODS AND RESULTS: Thirty male and 38 female patients were enrolled. LVH was found in 60% of men and 39% of women. Increased CCA IMT was equally present in males and females. There was a strong positive correlation between LV mass and CCA IMT (r2=0.27; P<0.0001). VSMC and neonatal cardiomyocyte proliferative response in vitro correlated with CCA IMT (r2=0.39; P<0.0004) and LV mass index (r2=0.19; P=0.028), respectively. CONCLUSIONS: LVH and CCA IMT occur concomitantly in Fabry suggesting common pathogenesis. The underlying cause may be a circulating growth-promoting factor whose presence has been confirmed in vitro.
Resumo:
OBJECTIVE: Balloon-expandable stent valves require flow reduction during implantation (rapid pacing). The present study was designed to compare a self-expanding stent valve with annular fixation versus a balloon-expandable stent valve. METHODS: Implantation of a new self-expanding stent valve with annular fixation (Symetis, Lausanne, Switzerland) was assessed versus balloon-expandable stent valve, in a modified Dynatek Dalta pulse duplicator (sealed port access to the ventricle for transapical route simulation), interfaced with a computer for digital readout, carrying a 25 mm porcine aortic valve. The cardiovascular simulator was programmed to mimic an elderly woman with aortic stenosis: 120/85 mmHg aortic pressure, 60 strokes/min (66.5 ml), 35% systole (2.8 l/min). RESULTS: A total of 450 cardiac cycles was analysed. Stepwise expansion of the self-expanding stent valve with annular fixation (balloon-expandable stent valve) resulted in systolic ventricular increase from 120 to 121 mmHg (126 to 830+/-76 mmHg)*, and left ventricular outflow obstruction with mean transvalvular gradient of 11+/-1.5 mmHg (366+/-202 mmHg)*, systolic aortic pressure dropped distal to the valve from 121 to 64.5+/-2 mmHg (123 to 55+/-30 mmHg) N.S., and output collapsed to 1.9+/-0.06 l/min (0.71+/-0.37 l/min* (before complete obstruction)). No valve migration occurred in either group. (*=p<0.05). CONCLUSIONS: Implantation of this new self-expanding stent valve with annular fixation has little impact on haemodynamics and has the potential for working heart implantation in vivo. Flow reduction (rapid pacing) is not necessary.
Resumo:
Atrial arrhythmias (AAs) are a common complication in adult patients with congenital heart disease. We sought to compare the lifetime prevalence of AAs in patients with right- versus left-sided congenital cardiac lesions and their effect on the prognosis. A congenital heart disease diagnosis was assigned using the International Disease Classification, Ninth Revision, diagnostic codes in the administrative databases of Quebec, from 1983 to 2005. Patients with AAs were those diagnosed with an International Disease Classification, Ninth Revision, code for atrial fibrillation or intra-atrial reentry tachycardia. To ensure that the diagnosis of AA was new, a washout period of 5 years after entry into the database was used, a period during which the patient could not have received an International Disease Classification, Ninth Revision, code for AA. The cumulative lifetime risk of AA was estimated using the Practical Incidence Estimators method. The hazard ratios (HRs) for mortality, morbidity, and cardiac interventions were compared between those with right- and left-sided lesions after adjustment for age, gender, disease severity, and cardiac risk factors. In a population of 71,467 patients, 7,756 adults developed AAs (isolated right-sided, 2,229; isolated left-sided, 1,725). The lifetime risk of developing AAs was significantly greater in patients with right- sided than in patients with left-sided lesions (61.0% vs 55.4%, p <0.001). The HR for mortality and the development of stroke or heart failure was similar in both groups (HR 0.96, 95% confidence interval [CI] 0.86 to 1.09; HR 0.94, 95% CI 0.80 to 1.09; and HR 1.10, 95% CI 0.98 to 1.23, respectively). However, the rates of cardiac catheterization (HR 0.63, 95% CI 0.55 to 0.72), cardiac surgery (HR 0.40, 95% CI 0.36 to 0.45), and arrhythmia surgery (HR 0.77, 95% CI 0.6 to 0.98) were significantly less for patients with right-sided lesions. In conclusion, patients with right-sided lesions had a greater lifetime burden of AAs. However, their morbidity and mortality were no less than those with left-sided lesions, although the rate of intervention was substantially different.
Resumo:
Aim Avoiding 'mini-laparotomy' to extract a colectomy specimen may decrease wound complications and further improve recovery after laparoscopic surgery. The aim of this study was to develop a new technique for transrectal specimen extraction (TRSE) and to compare it with conventional laparoscopy (CL) for left sided colectomy. Method Eleven patients with benign disease requiring either sigmoid or left colon resection underwent TRSE. The unfired circular stapler was inserted transanally and used as a guide to suture-close the recto-sigmoid junction laparoscopically and as a handle to pull the sutured sigmoid through the opened rectum inside a laparoscopic camera bag. The anvil was inserted into the lumen of the intussuscepted sigmoid and pushed to the level of the anastomosis. The anastomosis was fashioned end-to-end in the first patients and side-to-end in the following patients to improve safety. Intra-operative and postoperative outcomes of patients undergoing TRSE were compared with those of a group of 20 patients undergoing CL, who were matched for type of resection, body mass index and age. Results The procedure was successful in all but the first patient who was converted to conventional laparoscopic colectomy without any additional morbidity. Two patients in the end-to-end anastomosis group, but none in the side-to-end group, developed peri-anastomotic sepsis. Compared with CL, patients undergoing TRSE did not show any significant differences in operative time, recovery or morbidity. Conclusion Transrectal specimen extraction after left colectomy using the circular stapler technique is feasible. A side-to-end anastomosis appears safer than an end-to-end anastomosis. Further studies are needed to explore the potential advantages of this procedure over CL.
Resumo:
New products available for food creations include a wide variety of "supposed" food grade aerosol sprays. However, the gas propellants used cannot be considered as safe. The different legislations available did not rule any maximum residue limits, even though these compounds have some limits when used for other food purposes. This study shows a preliminary monitoring of propane, butane and dimethyl ether residues, in cakes and chocolate after spraying, when these gases are used as propellants in food aerosol sprays. Release kinetics of propane, butane and dimethyl ether were measured over one day with sprayed food, left at room temperature or in the fridge after spraying. The alkanes and dimethyl ether analyses were performed by headspace-gas chromatography-mass spectrometry/thermal conductivity detection, using monodeuterated propane and butane generated in situ as internal standards. According to the obtained results and regardingthe extrapolations of the maximum residue limits existing for these substances, different delays should be respected according to the storage conditions and the gas propellant to consume safely the sprayed food.
Resumo:
Recent years have been characterized by a series of publications in the field of firearms investigation questioning the reliability and objectivity of such examination. This research investigates new solutions to decrease the subjective component affecting the evaluation that follows the comparison of impressions left by a firearm on the surface of spent cartridge cases. An automatic comparison system based on 3D measurements has been developed and coupled to a bivariate evaluative model allowing assigning likelihood ratios. Based on a dataset of 79 pistols (all SIG Sauer 9 mm Luger caliber), the system shows a very high discriminating power and the LRs that it provides are very indicative of the true state under both the prosecution and the defense propositions. For example, likelihood ratios exceeding a billion are predominantly obtained when impressions originating from the same source are compared. The system is also characterized by relatively low rates (≤1%) of misleading evidence depending on the firearm considered.
Resumo:
BACKGROUND: Left atrial (LA) dilatation is associated with a large variety of cardiac diseases. Current cardiovascular magnetic resonance (CMR) strategies to measure LA volumes are based on multi-breath-hold multi-slice acquisitions, which are time-consuming and susceptible to misregistration. AIM: To develop a time-efficient single breath-hold 3D CMR acquisition and reconstruction method to precisely measure LA volumes and function. METHODS: A highly accelerated compressed-sensing multi-slice cine sequence (CS-cineCMR) was combined with a non-model-based 3D reconstruction method to measure LA volumes with high temporal and spatial resolution during a single breath-hold. This approach was validated in LA phantoms of different shapes and applied in 3 patients. In addition, the influence of slice orientations on accuracy was evaluated in the LA phantoms for the new approach in comparison with a conventional model-based biplane area-length reconstruction. As a reference in patients, a self-navigated high-resolution whole-heart 3D dataset (3D-HR-CMR) was acquired during mid-diastole to yield accurate LA volumes. RESULTS: Phantom studies. LA volumes were accurately measured by CS-cineCMR with a mean difference of -4.73 ± 1.75 ml (-8.67 ± 3.54%, r2 = 0.94). For the new method the calculated volumes were not significantly different when different orientations of the CS-cineCMR slices were applied to cover the LA phantoms. Long-axis "aligned" vs "not aligned" with the phantom long-axis yielded similar differences vs the reference volume (-4.87 ± 1.73 ml vs. -4.45 ± 1.97 ml, p = 0.67) and short-axis "perpendicular" vs. "not-perpendicular" with the LA long-axis (-4.72 ± 1.66 ml vs. -4.75 ± 2.13 ml; p = 0.98). The conventional bi-plane area-length method was susceptible for slice orientations (p = 0.0085 for the interaction of "slice orientation" and "reconstruction technique", 2-way ANOVA for repeated measures). To use the 3D-HR-CMR as the reference for LA volumes in patients, it was validated in the LA phantoms (mean difference: -1.37 ± 1.35 ml, -2.38 ± 2.44%, r2 = 0.97). Patient study: The CS-cineCMR LA volumes of the mid-diastolic frame matched closely with the reference LA volume (measured by 3D-HR-CMR) with a difference of -2.66 ± 6.5 ml (3.0% underestimation; true LA volumes: 63 ml, 62 ml, and 395 ml). Finally, a high intra- and inter-observer agreement for maximal and minimal LA volume measurement is also shown. CONCLUSIONS: The proposed method combines a highly accelerated single-breathhold compressed-sensing multi-slice CMR technique with a non-model-based 3D reconstruction to accurately and reproducibly measure LA volumes and function.
Resumo:
Objective To evaluate the utility of a new multimodal image-guided intervention technique to detect epileptogenic areas with a gamma probe as compared with intraoperative electrocorticography. Materials and Methods Two symptomatic patients with refractory epilepsy underwent magnetic resonance imaging, videoelectroencephalography, brain SPECT scan, neuropsychological evaluation and were submitted to gamma probe-assisted surgery. Results In patient 1, maximum radioactive count was initially observed on the temporal gyrus at about 3.5 cm posteriorly to the tip of the left temporal lobe. After corticotomy, the gamma probe indicated maximum count at the head of the hippocampus, in agreement with the findings of intraoperative electrocorticography. In patient 2, maximum count was observed in the occipital region at the transition between the temporal and parietal lobes (right hemisphere). During the surgery, the area of epileptogenic activity mapped at electrocorticography was also delimited, demarcated, and compared with the gamma probe findings. After lesionectomy, new radioactive counts were performed both in the patients and on the surgical specimens (ex-vivo). Conclusion The comparison between intraoperative electrocorticography and gamma probe-assisted surgery showed similarity of both methods. The advantages of gamma probe include: noninvasiveness, low cost and capacity to demonstrate decrease in the radioactive activity at the site of excision after lesionectomy.
Resumo:
Rabbits have been used as an experimental model in many diseases and for the study of toxicology, pharmacology and surgery in many universities. However, some aspects of their macro anatomy need a more detailed description, especially the abdominal and pelvic arterial vascular system, which has a huge variability in distribution and trajectory. Thirty cadaveric adult New Zealand rabbits, 13 male and 17 female, with an average weight and rostrum-sacral length of 2.5 kg and 40cm, respectively, were used. The thoracic aorta was cannulated and the vascular system was filled with stained latex S-65. The celiac artery and its proximal branches were dissected and lengthened in order to evidence origin and proximal ramifications. The celiac artery emerged between the 12th and 13th thoracic vertebra in 11 (36.7%) rabbits; at the level of the 13th thoracic vertebra in 6 (20%) rabbits; between the 13th thoracic vertebra and the 1st lumbar vertebra in 12 (40%) rabbits; and at the level of the 1st lumbar vertebra in only one (3.3%) rabbit. The mean length of the celiac artery was 0.5cm. The celiac artery first branch was the lienal artery, the second branch was the left gastric artery and the hepatic artery arose from the left gastric artery in all the dissected rabbits. No relation was observed between the celiac artery length and the rostrum-sacral length in rabbits. The number of left gastric and lienal artery branches and the distribution of celiac artery origin are not gender dependent.
Resumo:
This monograph dissertation looks into the field of ICT-mediated health and well-being services. Through six chapters that extend the work done in the reviewed and published articles, the dissertation focuses on new and emerging technologies, and to impact of their use on the beneficiary; the individual who eventually derives advantage from the services. As the field is currently going through major changes particularly in the OECD countries, the focus is on shortterm developments in the field and the analysis on the long term developments is cursory by nature. The dissertation includes theoretical and empirical elements. Most of the empirical elements are linked to product development and conceptualization performed in the national MyWellbeing project that ended in 2010. In the project, the emphasis was on conceptualization of a personal aid for the beneficiary that could be used for managing information and services in the field of health and well-being services. This work continued the theme of developing individual-centric solutions for the field; a work that started in the InnoElli Senior program in 2006. The nature of this thesis is foremost a conceptual elaboration based on a literature review, illustrated in empirical work performed in different projects. As a theoretical contribution, this dissertation elaborates the role of a mediator, i.e. an intermediary, and it is used as an overarching theme. The role acts as a ‘lens’ through which a number of technology-related phenomena are looked at, pinned down and addressed to a degree. This includes introduction of solutions, ranging from anthropomorphic artefacts to decision support systems that may change the way individuals experience clinical encounters in the near-future. Due to the complex and multiform nature of the field, it is impractical and effectively impossible to cover all aspects that are related to mediation in a single work. Issues such as legislation, financing and privacy are all of equal importance. Consideration of all these issues is beyond the scope of this dissertation and their investigation is left to other work. It follows from this that the investigation on the role is not intended as inclusive one. The role of the mediator is also used to highlight some of the ethical issues related to personal health information management, and to mediating health and well-being related issues on behalf of another individual, such as an elderly relative or a fellow member of a small unit in the armed forces. The dissertation concludes in a summary about the use and functions of the mediator, describing some potential avenues for implementing such support mechanisms to the changing field of ICT-mediated health and well-being services. The conclusions also describe some of the limitations of this dissertation, including remarks on methodology and content.
Resumo:
Atrial fibrillation (AF) affects subjects with Chagas' disease and is an indicator of poor prognosis. We investigated clinical, echocardiographic and electrocardiographic variables of Chagas' disease in a long-term longitudinal study as predictors of a new-onset AF episode lasting >24 h, nonfatal embolic stroke and cardiac death. Fifty adult outpatients (34 to 74 years old, 62% females) staged according to the Los Andes classification were enrolled. During a follow-up of (mean ± SD) 84.2 ± 39.0 months, 9 subjects developed AF (incidence: 3.3 ± 1.0%/year), 5 had nonfatal stroke (incidence: 1.3 ± 1.0%/year), and nine died (mortality rate: 2.3 ± 0.8%/year). The progression rate of left ventricular mass and left ventricular ejection fraction was significantly greater in subjects who experienced AF (16.4 ± 20.0 g/year and -8.6 ± 7.6%/year, respectively) than in those who did not (8.2 ± 8.4 g/year; P = 0.03, and -3.0 ± 2.5%/year; P = 0.04, respectively). In univariate analysis, left atrial diameter ≥3.2 cm (P = 0.002), pulmonary arterial hypertension (P = 0.035), frequent premature supraventricular and ventricular contraction counts/24 h (P = 0.005 and P = 0.007, respectively), ventricular couplets/24 h (P = 0.002), and ventricular tachycardia (P = 0.004) were long-term predictors of AF. P-wave signal-averaged ECG revealed a limited long-term predictive value for AF. In chronic Chagas' disease, large left atrial diameter, pulmonary arterial hypertension, frequent supraventricular and ventricular premature beats, and ventricular tachycardia are long-term predictors of AF. The rate of left ventricular mass enlargement and systolic function deterioration impact AF incidence in this population.
Resumo:
Previous assessment of verticality by means of rod and rod and frame tests indicated that human subjects can be more (field dependent) or less (field independent) influenced by a frame placed around a tilted rod. In the present study we propose a new approach to these tests. The judgment of visual verticality (rod test) was evaluated in 50 young subjects (28 males, ranging in age from 20 to 27 years) by randomly projecting a luminous rod tilted between -18 and +18° (negative values indicating left tilts) onto a tangent screen. In the rod and frame test the rod was displayed within a luminous fixed frame tilted at +18 or -18°. Subjects were instructed to verbally indicate the rod’s inclination direction (forced choice). Visual dependency was estimated by means of a Visual Index calculated from rod and rod and frame test values. Based on this index, volunteers were classified as field dependent, intermediate and field independent. A fourth category was created within the field-independent subjects for whom the amount of correct guesses in the rod and frame test exceeded that of the rod test, thus indicating improved performance when a surrounding frame was present. In conclusion, the combined use of subjective visual vertical and the rod and frame test provides a specific and reliable form of evaluation of verticality in healthy subjects and might be of use to probe changes in brain function after central or peripheral lesions.
Dr. Vernon Stauffer [left] on the California Christian College campus, Los Angeles, California, 1921
Resumo:
Dr. Vernon Stauffer [left], Dean and Professor of New Testament and Church History and unidentified on the California Christian College campus [later Chapman College], Los Angeles, California, 1921.