928 resultados para Needle bearings


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cytomorphologic characteristics of smears from fine-needle aspirates (FNA) of three cases of sinus histiocytosis with massive lymphadenopathy (SHML) (Rosai-Dorfman disease) are described. All aspirates showed mature lymphocytes, plasma cells, and large pale histiocytes with well-preserved lymphocytes within the cytoplasm (lymphocytophagocytosis). The cases were confirmed by surgical biopsy, and the immunohistochemical findings suggested a macrophage origin for this lesion. The value of FNA analysis as an aid to diagnosis of SHML is discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Testicular biopsy has been a complementary technique for clinical and research purposes to evaluate reproductive function in males. However, hemorrhage, inflammation, degeneration, and adhesion are factors that might limit the use of this procedure. In order to minimize these potential problems, fibrin glue derived from snake venom, a tissue adhesive with sealing, hemostatic, and healing properties, was used in conjunction with bilateral testicular biopsy with the Tru-Cut needle and was compared with a more conventional technique that uses nylon suture. Thirty mature rams were randomly assigned to three groups of 10 animals each, as follows: nonsurgical control group (no scrotal surgery, or biopsy); biopsy + glue group (fibrin glue on puncture sites and skin incisions) and biopsy + suture group (compression with swab on puncture sites and suturing of skin incision). The surgeries of the rams in the biopsy groups were performed on the same day, which was designated Day 0 for all three groups. Data of scrotal circumference, number of spermatozoa per ejaculum, percentage of morphologically abnormal spermatozoa, spermatozoa motility, and serum testosterone concentrations from Days -7, 20, 40, 60, 80 and 100 were evaluated. There were no significant differences between groups within days for any of the parameters evaluated. In conclusion, the testicular biopsy procedure using the Tru-Cut needle in conjunction with conventional nylon suture or the more novel fibrin glue in rams did not affect any of the parameters of testicular function evaluated in this study and was shown to be relatively simple, safe and efficient. (C) 2002 Published by Elsevier B.V. B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A primary carcinoid tumour of the breast in a 66-year-old man was diagnosed by fine-needle aspiration cytology. The nature of the lesion was proved by histochemical and immunocytochemical studies. The importance of a conclusive diagnosis is discussed and the value of immunocytochemical analysis as an aid to cytomorphologic diagnosis is demonstrated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Sister Mary Joseph (SMJ) nodule is a clinical sign of metastatic cancer involving the umbilicus. The vast majority of these instances represent adenocarcinomas arising from ovarian or colorectal primaries. We present a patient who presented with ascites and the SMJ lesion that turned out to be a metastatic gastrointestinal stromal tumor after fine needle aspiration biopsy was performed. The lesion was subsequently histologically confirmed. Gastrointestinal stroma tumor involving the umbilicus is exceedingly uncommon and only rarely presents in this fashion. The cytomorphological features, differential diagnosis, and comparison with the tissue specimen are made. © 2006 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a software tool, called LEVSOFT, suitable for the electric field simulations of corona electrodes by the Finite Element Method (FEM). Special attention was paid to the user friendly construction of geometries with corners and sharp points, and to the fast generation of highly refined triangular meshes and field maps. The execution of self-adaptive meshes was also implemented. These customized features make the code attractive for the simulation of needle-type corona electrodes. Some case examples involving needle type electrodes are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cytology is a well established research technique in human and veterinary medicine, but it is rarely used in small rodents. Spontaneous tumors are relatively uncommon in guinea pigs and those described in literature include a variety of organs like skin and subcutis, respiratory and reproductive tract, endocrine and hematopoietic system, and mammary gland. The objective of this article was to describe the use of the fine needle aspiration biopsy technique (FNAB) on evaluation of a mammary neoplasm in a guinea pig and describe the main cytological findings for the first time in literature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultrasound (US) has been used as a tool for parotid abscess diagnosis and treatment. The present article aimed to report a case of 72-year-old woman with parotid abscess treated by US-guided needle aspiration and conventional surgical drainage. Along with the clinical report, indications, advantages, and limitations of the method are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: We evaluated the presence of ductal carcinoma in situ (DCIS) in core needle biopsies (CNB) from invasive ductal lesions. Methods: Retrospective study, which analyzed 90 cases of invasive ductal carcinoma lesions. The percentage of DCIS was quantified in each specimens obtained from CNB, which were compared to the surgical specimens. CNB and surgical specimens were evaluated by the same pathologist, and the percentage of DCIS in CNB was evaluated (percentage) and divided into categories. We considered the following parameters regarding the amount of DCIS: 1 = 0; 2 = 1 for 5%; 3 = 6 for 24%; 4 = 25 for 50%; 5 = 51 for 75% and 6 = 76 for 99%. The number of fragments and the histological pattern of DCIS was found. Results: We found the following results regarding the distribution of the percentage of DCIS in the CNB: 1 = 63.3%; 2 = 12.2%; 3 = 12.2%; 4 = 5.6%; 5 = 1.1% and 6 = 5.6%. The logistic regression analysis showed that CNB percentages above 45% reflected the presence of DCIS in the surgical specimen in 100% of the cases (p<0.001), with a specificity of 100%, accuracy of 83.3% and false positive rate of 0% (p <0.001). Conclusion: There is direct relationship between extensive intraductal component in the surgical specimen when the core biopsy shows 45% or more of the DCI or microinvasive in the material examined. © 2012 Barbalaco Neto et al.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For intricate automotive systems that enclose several components, such as gearboxes, an important aspect of the design is defining the correct assembly parameters. A proper assembly can ensure optimized operating conditions and therefore the components can achieve a longer life. In the case of the support bearings applied to front-axle lightweight differentials, the assembly preload is a major aspect for an adequate performance of the system. During the design phase it is imperative to define reference values to this preload, so the application would endure its requirements. However, with the assistance of computer simulations, it is possible to determine an optimum condition of operation, i.e. optimum pre-load, which would increase the system reliability. This paper presents a study on the influence of preload on the rating life of tapered roller bearings applied to light-weight front axle differentials, evaluating how preload affects several key parameters such as rating life and displacement of components, taking into account the flexibility of the surrounding differential housing. Copyright © 2012 SAE International.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: To evaluate the reliability of fine needle aspirate cell blocks in the assessment of oestrogen receptor (ER), progesterone receptor (PR) and HER-2/neu proteins by immunohistochemistry in comparison with surgical specimens. Materials and methods: This is a retrospective study of 62 cases of breast carcinoma diagnosed by fine needle aspiration cytology (FNAC) and confirmed using the surgical specimen. Immunohistochemical tests were performed to assess the presence of oestrogen receptor (ER), progesterone receptor (PR) and HER-2/neu proteins in cell blocks and the corresponding surgical specimens. The cell block method used alcohol prior to formalin fixation. Cases with 10% or more stained cells were considered positive for ER and PR. Positivity for HER-2/neu was assessed on a scale of 0-3+. The criterion for positivity was a score of 3+. Results: Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of the cell blocks in the investigation of ER, PR and HER-2/neu protein (3+) were (%): ER, 92.7, 85.7, 92.7, 85.7 and 90.3; PR, 92.7, 94.7, 97.4, 87.0 and 93.5; HER-2/neu, 70.0, 100.0, 100.0, 94.5 and 95.2. Discrepancies were seen in cell blocks in the 1+ and 2+ HER-2/neu staining scores: two of 12 cases scoring 2+ and one case of 26 scoring 1+ on cell blocks scored 3+ on surgical specimens. The correlation index between cell block and corresponding surgical specimen varied from 90% to 94%. Conclusion: Cell blocks provide a useful method of assessing ER, PR and HER-2/neu, mainly for inoperable and recurrent cases, but consideration should be given to carrying out FISH analysis on 1+ as well as 2+ HER-2/neu results. © 2012 Blackwell Publishing Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A case of primary squamous-cell carcinoma (SCC) of the thyroid which had been initially diagnosed as an anaplastic carcinoma (ATC) is described: female, 73 years old, with a fast-growing cervical nodule on the left side and hoarseness for 3 months. Ultrasonography showed a 4.5 cm solid nodule. FNA was compatible with poorly differentiated carcinoma with immunoreactivity for AE1/AE3, EMA. Thyroidectomy was performed. Histopathological examination showed a nonencapsulated tumor. Immunohistochemistry disclosed positivity for AE1/AE3, p53,p63, and Ki67. The diagnosis was ATC. A second opinion reported tumor consisting of squamous cells, with intense inflammatory infiltrate both in tumor and in the adjacent thyroid, with final diagnosis of SCC, associated with Hashimoto thyroiditis. No other primary focus of SCC was found. Patient has shown a 48-month survival period. Clinically, primary SCCs of the thyroid and ATCs are similar. The distinction is often difficult particularly when based on the cytological analysis of FNA material.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To identify associations between cytological criteria in fine needle aspiration (FNA) specimens and histological subtypes of lobular breast carcinoma (classical and other types). Study Design: FNA cytology and mastectomy specimens from 72 cases of invasive lobular breast carcinoma were consecutively retrieved from the files of the Amaral de Carvalho Hospital, Jaú-São Paulo, Brazil. All cases were reviewed regarding five cytological criteria: cellularity, cellular cohesion, presence of inflammation, nucleoli and nuclear atypia. The χ2 test or Fisher's exact tests with 95% confidence intervals (CI) were used. Results: The classical type showed lower initial cytological diagnosis of malignancy compared to the other variants (p = 0.017; odds ratio (OR) 0.26, 95% CI 0.89-0.80). Moderate/intense cellular cohesion (p = 0.011; OR 0.18, 95% CI 0.04-0.73) and mild atypia (p = 0.000; OR 16.15, 95% CI 3.20-81.48) were significantly associated with the classical type of lobular breast carcinoma, while the absence of inflammation (p = 0.082; OR 0.36, 95% CI 0.12-1.15) was marginally associated with the classical type. Conclusions: In cytology, the characterization of lobular carcinoma as malignant is difficult, especially the classical type. The association between cell cohesion and the classical type of lobular breast carcinoma may be one of the factors that complicate this diagnosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Linear parameter varying (LPV) control is a model-based control technique that takes into account time-varying parameters of the plant. In the case of rotating systems supported by lubricated bearings, the dynamic characteristics of the bearings change in time as a function of the rotating speed. Hence, LPV control can tackle the problem of run-up and run-down operational conditions when dynamic characteristics of the rotating system change significantly in time due to the bearings and high vibration levels occur. In this work, the LPV control design for a flexible shaft supported by plain journal bearings is presented. The model used in the LPV control design is updated from unbalance response experimental results and dynamic coefficients for the entire range of rotating speeds are obtained by numerical optimization. Experimental implementation of the designed LPV control resulted in strong reduction of vibration amplitudes when crossing the critical speed, without affecting system behavior in sub- or supercritical speeds. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate whether immunohistochemical marker studies performed on core needle biopsy (CNB) specimens accurately reflect the marker status of the tumor obtained from final surgical specimen. Methods: This was a retrospective study that used the database of the Division of Mastology of the Hospital das Clinicas, Sao Paulo, Brazil. Sixty-nine patients submitted to ultrasound-guided CNB diagnosed with breast cancer were retrospectively analyzed. Immunohistochemistry (IHC) on core biopsy specimens was compared to that of excisional biopsy regarding estrogen receptor (ER), progesterone receptor (PR), human epidermal gowth factor receptor 2 gene (HER2), p53, and Ki67. The analysis of the concordance between CNB and surgical biopsy was performed using the kappa (k) coefficient (95% CI). Results: A perfect concordance between the labeling in the surgical specimens and the preoperative biopsies in p53 (k = 1.0; 95% CI: 0.76-1.0) was identified. There was an almost perfect concordance for ER (k = 0.89; 95% CI: 0.65-1.0) and a substantial concordance for PR (k = 0.70; 95% CI: 0.46-0.93). HER2 (k = 0.61; 95% CI: 0.38-0.84) and Ki-67 (k = 0.74; 95% CI: 0.58-0.98) obtained a substantial concordance this analysis. Conclusion: The results of this study indicate that the immunohistochemical analysis of ER, PR, Ki-67, and p53 from core biopsy specimens provided results that accurately reflect the marker status of the tumor. The concordance rate of HER2 was less consistent; although it produced substantial concordance, values were very close to moderate concordance.