947 resultados para Nd : YAG transparent ceramic


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Odontologia Restauradora - ICT

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The success of endodontic treatment depends on the complete elimination of microorganisms from the root canal system, thus the search for new procedures to eliminate them is justified. The aim of this study was to assess bacterial reduction after intracanal irradiation with the Er:YAG laser. The canals of 70 extracted human maxillary canines were prepared up to file #40 using 1% NaOCl, irrigated with 17% EDTA, and then washed with physiological solution activated by ultrasound. The roots were sterilized by autoclaving, inoculated with 10 mu l of a suspension containing 1.5 x 10(8) CFU/ml of Enterococcus faecalis ATCC 29212 and incubated at 37A degrees C for 72 h. The canals were irradiated with the Er:YAG laser using two energy settings: 60 mJ and 15 Hz, and 100 mJ and 10 Hz. The remaining bacteria were counted immediately and 48 h after laser irradiation. The results showed a high bacterial reduction at both time points. With 60 mJ and 15 Hz there was an immediate reduction of 99.73% and the reduction was 77.02% after 48 h, and with 100 mJ and 10 Hz there was an immediate reduction of 99.95% and the reduction was 84.52% after 48 h. Although the best results were observed with 100 mJ of energy, the difference between the two settings was not statistically significant. The count performed 48 h after irradiation showed that E. faecalis were able to survive, and can grow even from small numbers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tribochemical silica-coating is the recommended conditioning method for improving glass-infiltrated alumina composite adhesion to resin cement. High-intensity lasers have been considered as an alternative for this purpose. This study evaluated the morphological effects of Er,Cr:YSGG laser irradiation on aluminous ceramic, and verified the microtensile bond strength of composite resin to ceramic following silica coating or laser irradiation. In-Ceram Alumina ceramic blocks were polished, submitted to airborne particle abrasion (110 mu m Al(2)O(3)), and conditioned with: (CG) tribochemical silica coating (110 mu m SiO(2)) + silanization (control group); (L1-L10) Er,Cr:YSGG laser (2.78 mu m, 20 Hz, 0.5 to 5.0 W) + silanization. Composite resin blocks were cemented to the ceramic blocks with resin cement. These sets were stored in 37A degrees C distilled water (24 h), embedded in acrylic resin, and sectioned to produce bar specimens that were submitted to microtensile testing. Bond strength values (MPa) were statistically analyzed (alpha a parts per thousand currency sign0.05), and failure modes were determined. Additional ceramic blocks were conditioned for qualitative analysis of the topography under SEM. There were no significant differences among silicatization and laser treatments (p > 0.05). Microtensile bond strength ranged from 19.2 to 27.9 MPa, and coefficients of variation ranged from 30 to 55%. Mixed failure of adhesive interface was predominant in all groups (75-96%). No chromatic alteration, cracks or melting were observed after laser irradiation with all parameters tested. Surface conditioning of glass-infiltrated alumina composite with Er,Cr:YSGG laser should be considered an innovative alternative for promoting adhesion of ceramics to resin cement, since it resulted in similar bond strength values compared to the tribochemical treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

El proceso de soldadura por láser desarrollado en los últimos años ha puesto de manifiesto las posibilidades de aplicación de esta tecnología en diferentes sectores productivos, principalmente en la industria automovilística, en la cual se han demostrado sus ventajas en términos de productividad, eficiencia y calidad. El uso de la tecnología láser, ya sea híbrida o pura, reduce el input térmico al limitar la zona afectada por el calor, sin crear deformaciones y, por tanto, disminuye los re-trabajos post-soldadura necesarios para eliminarlas. Asimismo, se aumenta la velocidad de soldadura, incrementando la productividad y calidad de las uniones. En la última década, el uso de láseres híbridos, (láser + arco) de gran potencia de Neodimio YAG, (Nd: YAG) ha sido cada vez más importante. La instalación de este tipo de fuentes de láser sólido de gran potencia ha sido posible en construcción naval debido a sus ventajas con respecto a las instalaciones de láser de C02 existentes en los astilleros que actualmente utilizan esta tecnología. Los láseres de C02 están caracterizados por su gran potencia y la transmisión del haz a través de espejos. En el caso de las fuentes de Nd:YAG, debido a la longitud de onda a la cual se genera el haz láser, su transmisión pueden ser realizada a través de fibra óptica , haciendo posible la utilización del cabezal láser a gran distancia de la fuente, aparte de la alternativa de integrar el cabezal en unidades robotizadas. El proceso láser distribuye el calor aportado de manera uniforme. Las características mecánicas de dichas uniones ponen de manifiesto la adecuación de la soldadura por láser para su uso en construcción naval, cumpliendo los requerimientos exigidos por las Sociedades de Clasificación. La eficiencia energética de los láseres de C02, con porcentajes superiores al 20%, aparte de las ya estudiadas técnicas de su instalación constituyen las razones por las cuales este tipo de láser es el más usado en el ámbito industrial. El láser de gran potencia de Nd: YAG está presente en el mercado desde hace poco tiempo, y por tanto, su precio es relativamente mayor que el de C02, siendo sus costes de mantenimiento, tanto de lámparas como de diodos necesarios para el bombeo del sólido, igualmente mayores que en el caso del C02. En cambio, el efecto de absorción de parte de la energía en el plasma generado durante el proceso no se produce en el caso del láser de Nd: YAG, utilizando parte de esa energía en estabilizar el arco, siendo necesaria menos potencia de la fuente, reduciendo el coste de la inversión. En función de la aplicación industrial, se deberá realizar el análisis de viabilidad económica correspondiente. Dependiendo de la potencia de la fuente y del tipo de láser utilizado, y por tanto de la longitud de onda a la que se propaga la radiación electromagnética, pueden existen riesgos para la salud. El láser de neodimio se propaga en una longitud de onda, relativamente cercana al rango visible, en la cual se pueden producir daños en los ojos de los operadores. Se deberán establecer las medidas preventivas para evitar los riesgos a los que están expuestos dichos operadores en la utilización de este tipo de energía. La utilización del láser de neodimio: YAG ofrece posibilidades de utilización en construcción naval económicamente rentables, debido su productividad y las buenas características mecánicas de las uniones. Abstract The laser welding process development of the last years shows broad application possibilities in many sectors of industry, mostly in automobile production. The advantages of the laser beam process produce higher productivity, increasing the quality and thermal efficiency. Laser technology, arc-hybrid or pure laser welding, reduces thermal input and thus a smaller heat-affected zone at the work piece. This means less weldment distortion which reduces the amount of subsequent post-weld straightening work that needs to be done. A higher welding speed is achieved by use of the arc and the laser beam, increasing productivity and quality of the joining process. In the last decade use of hybrid technology (laser-GMA hybrid method) with high power sources Nd:YAG lasers, gained in importance. The installation of this type of higher power solid state laser is possible in shipbuilding industrial applications due to its advantages compare with the C02 laser sources installed in the shipyards which use this technology. C02 lasers are characterised by high power output and its beam guidance is via inelastic system of mirrors. In the case of Nd:YAG laser, due to its wavelength, the laser beam can be led by means of a flexible optical fibre even across large distances, which allows three dimensional welding jobs by using of robots. Laser beam welding is a process during which the heat is transferred to the welded material uniformly and the features of the process fulfilled the requirements by Classification Societies. So that, its application to the shipbuilding industry should be possible. The high quantum efficiency of C02 laser, which enabled efficiency factors up to 20%, and relative simple technical possibilities of implementation are the reasons for the fact that it is the most important laser in industrial material machining. High power Nd: YAG laser is established on the market since short time, so that its price is relatively high compared with the C02 laser source and its maintenance cost, lamp or diode pumped solid state laser, is also higher than in the case of C02 lasers. Nevertheless effect of plasma shielding does not exist with Nd:YAG lasers, so that for the gas-shielding welding process the optimal gases can be used regarding arc stability, thus power source are saved and the costs can be optimised. Each industrial application carried out needs its cost efficiency analysis. Depending on the power output and laser type, the dangerousness of reflected irradiation, which even in some meters distance, affects for the healthy operators. For the YAG laser process safety arrangements must be set up in order to avoid the laser radiation being absorbed by the human eye. Due to its wavelength of radiation, being relatively close to the visible range, severe damage to the retina of the eye is possible if sufficient precautions are not taken. Safety aspects are of vital importance to be able to shield the operator as well as other personal. The use of Nd:YAG lasers offers interesting and economically attractive applications in shipbuilding industry. Higher joining rates are possible, and very good mechanical/technological parameters can be achieved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To assess the influence of Nd:YAG (neodymium: yttrium-aluminum- garnet) laser unilateral posterior capsulotomy on visual acuity and patients' perception of difficulties with vision-related activities of daily life. METHODS: We conducted an interventional survey that included 48 patients between 40 and 80 years of age with uni- or bilateral pseudophakia, posterior capsule opacification, and visual acuity <0.30 (logMAR) in one eye who were seen at a Brazilian university hospital. All patients underwent posterior capsulotomy using an Nd:YAG laser. Before and after the intervention, patients were asked to complete a questionnaire that was developed in an exploratory study. RESULTS: Before posterior capsulotomy, the median visual acuity (logMAR) of the included patients was 0.52 (range 0.30-1.60). After posterior capsulotomy, the median visual acuity of the included patients improved to 0.10 (range 0.0-0.52). According to the subjects' perceptions, their ability to perform most of their daily life activities improved after the intervention (p<0.05). CONCLUSIONS: After patients underwent posterior capsulotomy with an Nd:YAG laser, a significant improvement in the visual acuity of the treated eye was observed. Additionally, subjects felt that they experienced less difficulty performing most of their vision-dependent activities of daily living.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To evaluate the effectiveness of photocoagulation with high-intensity diode laser in the treatment of venous lake (VL) lesions. Background Data: VL is a common vascular lesion characterized by elevated, usually dome-shaped papules, ranging in color from dark blue to dark purple, seen more frequently in elderly patients. They often occur as single lesions on the ears, face, lips, or neck. Once formed, lesions persist throughout life. Although these lesions are usually asymptomatic, they can bleed if injured. Methods: Seventeen patients (7 men and 10 women) with VL on the lip were treated using a noncontact diode laser (wavelength 808 nm, power output 2-3 W in continuous wave). Results: After only one irradiation exposure, all lesions were successfully treated. Healing was completed in approximately 2 to 3 weeks, and none of the patients experienced complications. Postoperative discomfort and scarring were not present or were minimal. Conclusion: Photocoagulation with high-intensity diode laser is an effective, bloodless procedure for the treatment of VL.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: This study evaluated ultra-structural dentine changes at the apical stop after CO(2) laser irradiation used during biomechanical preparation. Background: Most studies evaluating the sealing efficiency of CO(2) lasers have been carried out after apical root canal resections and retro-filling procedures. Methods: Sixty human canines were prepared with #1 to #6 Largo burs. The apical stops were established at 1 mm (n = 30) and 2 mm (n = 30) from the apex. Final irrigation was performed with 1% NaOCl and 15% EDTA followed by 20 ml of distilled and deionized water. Specimens were subdivided into three subgroups (n = 10 for each stop distance): GI-no radiation (n = 20); GII-3W potency (n = 20), GIII-5W potency (n = 20). After preparation, specimens were evaluated by scanning electron microscopy, with ultra-structural changes classified according to a scoring system based on six qualitatively different outcomes. Results: Statistical analysis using the Mann-Whitney test confirmed more intense results for the specimens irradiated at 5 W potency than at 3 W (p<0.0001). The Kruskal-Wallis test indicated that when using the same potencies (3 or 5 W) at 1 and 2 mm from the apex, there were no statistically significant differences in ultra-structural changes. Conclusions: Our results showed that ultra-structural changes ranged from smear layer removal to dentine fusion. As laser potency was increased from 3 to 5 W, ultra-structural changes included extensive fused lava-like areas sealing the apical foramen.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: The purpose of this in vitro study was to investigate using the scanning electron microscope (SEM) the ultrastructural morphological changes of the radicular dentine surface after irradiation with 980-nm diode laser energy at different parameters and angles of incidence. Background Data: There have been limited reports on the effects of diode laser irradiation at 980 nm on radicular dentin morphology. Materials and Methods: Seventy-two maxillary canines were sectioned and roots were biomechanically prepared using K3 rotary instruments. The teeth were irrigated with 2 mL of distilled water between files and final irrigation was performed with 10 mL of distilled water. The teeth were then randomly divided into five groups (n = 8 each) according to their diode laser parameters: Group 1: no irradiation (control); group 2: 1.5 W/continuous wave (CW) emission (the manufacturer's parameters); group 3: 1.5 W/100 Hz; group 4: 3 W/CW; and group 5: 3 W/100 Hz. Laser energy was applied with helicoid movements (parallel to the canal walls) for 20 sec. Eight additional teeth for each group were endodontically prepared and split longitudinally and irradiation was applied perpendicularly to the root surface. Results: Statistical analysis showed no difference between the root canal thirds irradiated with the 980-nm diode laser, and similar results between the parameters 1.5 W/CW and 3 W/100 Hz (p > 0.05). Conclusion: When considering different output powers and delivery modes our results showed that changes varied from smear layer removal to dentine fusion.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To evaluate the potential of 980-nm gallium aluminum arsenide (GaAlAs) and 1064-nm neodymium-doped yttrium aluminum garnet (Nd:YAG) lasers to reduce bacteria after irradiation of implant surfaces contaminated with Enterococcus faecalis and Porphyromonas gingivalis and on irradiated implant surface morphology. Background: Despite the frequency of implant success, some implant loss is related to peri-implantitis because of difficulty in eliminating the biofilm. Methods: Implants (3.75 x 13 mm) with machined surfaces, surfaces sand blasted with titanium oxide (TiO(2)), and sand-blasted and acid-etched surfaces were exposed to P. gingivalis and E. faecalis cultures and irradiated with 980-nm GaAlAs or 1064-nm Nd: YAG lasers. After laser treatments, the number of remaining colony-forming units and implant surface morphology were analyzed using scanning electron microscopy (SEM). Results: The Nd: YAG laser was able to promote a total contamination reduction on all implants irradiated. The results with the GaAlAs laser showed 100% bacteria reduction on the implants irradiated with 3 W. Irradiation with 2.5 W and 3 W achieved 100% of bacteria reduction on P. gingivalis-contaminated implants. Decontamination was not complete for the sand-blasted TiO(2) (78.6%) and acid-etched surfaces (49.4%) contaminated with E. faecalis and irradiated with 2.5 W. SEM showed no implant surface changes. Conclusion: The wavelengths used in this research provided bacteria reduction without damaging implant surfaces. New clinical research should be encouraged for the use of this technology in the treatment of peri-implantitis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We propose a method for measuring hyper-Rayleigh scattering employing pulse trains produced by a Q-switched and mode-locked Nd:YAG laser. The use of the entire pulse train under the Q-switch envelope avoids the need of any device to scan the irradiance, as is usually done with nanosecond and femtosecond single-pulse lasers. To verify the feasibility of the technique, we performed measurements in different solutions of para-nitroaniline and compared the results with those obtained with nanosecond pulses. In both cases, the agreement with the hyperpolarizability values reported in the literature is about the same, but the measurements carried out with pulse trains are at least 20 times faster. Besides the advantage of acquisition speed, the use of pulse trains also allows the instantaneous inspection of slow luminescence contributions arising from multiphoton absorption. (C) 2008 Optical Society of America.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It has been demonstrated that laser induced breakdown spectrometry (LIBS) can be used as an alternative method for the determination of macro (P, K. Ca, Mg) and micronutrients (B, Fe, Cu, Mn, Zn) in pellets of plant materials. However, information is required regarding the sample preparation for plant analysis by LIBS. In this work, methods involving cryogenic grinding and planetary ball milling were evaluated for leaves comminution before pellets preparation. The particle sizes were associated to chemical sample properties such as fiber and cellulose contents, as well as to pellets porosity and density. The pellets were ablated at 30 different sites by applying 25 laser pulses per site (Nd:YAG@1064 nm, 5 ns, 10 Hz, 25J cm(-2)). The plasma emission collected by lenses was directed through an optical fiber towards a high resolution echelle spectrometer equipped with an ICCD. Delay time and integration time gate were fixed at 2.0 and 4.5 mu s, respectively. Experiments carried out with pellets of sugarcane, orange tree and soy leaves showed a significant effect of the plant species for choosing the most appropriate grinding conditions. By using ball milling with agate materials, 20 min grinding for orange tree and soy, and 60 min for sugarcane leaves led to particle size distributions generally lower than 75 mu m. Cryogenic grinding yielded similar particle size distributions after 10 min for orange tree, 20 min for soy and 30 min for sugarcane leaves. There was up to 50% emission signal enhancement on LIBS measurements for most elements by improving particle size distribution and consequently the pellet porosity. (C) 2011 Elsevier B.V. All rights reserved.