889 resultados para Motor Evoked Potential


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: To study the components of long latency auditory evoked potentials and to compare data from these measures in students with and without learning disabilities. Method: Thirty students, 15 with learning disorder (study group) and 15 typical without learning problems (control group), of both genders, aged 7-14 years, mean age 10 years. They underwent clinical assessment in a clinic belonging to a public university in the state of São Paulo. Following, audiological assessment was performed to determine normal peripheral auditory system and electrophysiological assessment by examining the long latency auditory evoked response. Result: The results showed that there are functional differences between the groups. Increased latency components of long latency auditory evoked potential was observed in the study group compared to the control group. Longer latency values of these components were observed in the left ear when stimulated in the study group. Conclusion: This study contributed to better understanding of the auditory pathway functioning in children with learning disorders and can be a reference for other clinical and experimental studies and thus improve the definition of diagnostic criteria in this population.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Medicina Veterinária - FMVZ

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Contrast sensitivity (CS) was evaluated in 41 former workers from a lamp manufacturing plant who were on disability retirement due to exposure to mercury and 14 age-matched controls. The CS was measured monocularly using the sweep visual evoked potential (sVEP) paradigm at 6 spatial frequencies (0.2, 0.8, 2.0, 4.0, 15.0, and 30 cpd). Statistical difference (p < 0.05) was found between the controls and the patient right and left eyes for 2.0 and 4.0 cpd. According the results in those spatial frequencies the eyes were classified in best and worst. Statistical differences were found between the controls and the best eyes for 2.0 and 4.0 cpd and for 0.8, 2.0, and 4.0 cpd for their worst eyes. No correlation was found between CS results and the time of exposure (mean 8.9 yr +/- 4.1), time away from the mercury source (mean = 6.0 yr +/- 3.9), urinary mercury level at the time of work (mean = 40.6 mu g/g +/-36.3) or with the mercury level at the CS measurement time (mean = 1.6 mu g/g +/-1.1). We show the first evidence of a permanent impairment in CS measured objectively with the sVEP. Our data complement the previous psychophysical works reporting a diffuse impairment in the CS function showing a CS reduction in the low to middle spatial frequencies. In conclusion, non-reversible CS impairment was found in occupational exposure to mercury vapor. We suggest that CS measurement should be included in studies of the mercury effects of occupational exposure. (C) 2007 Elsevier Inc. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Amazonian gold mining activity results in human exposure to mercury vapor. We evaluated the visual system of two Amazonian gold miners (29 and 37 years old) by recording the transient pattern electroretinogram (tPERG) and transient pattern visual evoked potential (tPVEP). We compared these results with those obtained from a regional group of control subjects. For both tPERG and tPVEP, checkerboards with 0.5 or 2 cycles per degree (cpd) of spatial frequency were presented in a 16 degrees squared area, 100% Michelson contrast, 50cd/m(2) mean luminance, and 1 Hz square-wave pattern-reversal presentation. Two averaged waveforms (n = 240 sweeps, Is each) were monocularly obtained for each subject in each condition. Both eyes were monocularly tested only in gold miners. Normative data were calculated using a final pooled waveforin with 480 sweeps. The first gold miner, LCS, had normal tPERG responses. The second one, RNP, showed low tPERG (P50 component) amplitudes at 0.5cpd for both eyes, outside the normative data, and absence of response at 2 cpd for his right eye. Delayed tPVEP responses (P 100 component) were found at 2 cpd for LCS but the implicit times were inside the normative data. Subject RNP also showed delayed tPVEP responses (all components), but only the implicit time obtained with his right eye was outside the normative data at 2cpd. We conclude that mercury exposure levels found in the Amazon gold miners is high enough to damage the visual system and can be assessed by non-invasive electrophysiological techniques. (C) 2007 Elsevier Inc. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

There are several electrophysiological systems available commercially. Usually, control groups are required to compare their results, due to the differences between display types. Our aim was to examine the differences between CRT and LCD/TFT stimulators used in pattern VEP responses performed according to the ISCEV standards. We also aimed to check different contrast values toward thresholds. In order to obtain more precise results, we intended to measure the intensity and temporal response characteristics of the monitors with photometric methods. To record VEP signals, a Roland RetiPort electrophysiological system was used. The pattern VEP tests were carried out according to ISCEV protocols on a CRT and a TFT monitor consecutively. Achromatic checkerboard pattern was used at three different contrast levels (maximal, 75, 25%) using 1A degrees and 15` check sizes. Both CRT and TFT displays were luminance and contrast matched, according to the gamma functions based on measurements at several DAC values. Monitor-specific luminance parameters were measured by means of spectroradiometric instruments. Temporal differences between the displays` electronic and radiometric signals were measured with a device specifically built for the purpose. We tested six healthy control subjects with visual acuity of at least 20/20. The tests were performed on each subject three times on different days. We found significant temporal differences between the CRT and the LCD monitors at all contrast levels and spatial frequencies. In average, the latency times were 9.0 ms (+/- 3.3 ms) longer with the TFT stimulator. This value is in accordance with the average of the measured TFT input-output temporal difference values (10.1 +/- A 2.2 ms). According to our findings, measuring the temporal parameters of the TFT monitor with an adequately calibrated measurement setup and correcting the VEP data with the resulting values, the VEP signals obtained with different display types can be transformed to be comparable.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The auditory brainstem response (ABR) is a test widely used to assess the integrity of the brain stem. Although it is considered to be an auditory-evoked potential that is influenced by the physical characteristics of the stimulus, such as rate, polarity and type of stimulus, it may also be influenced by the change in several parameters. The use of anesthetics may adversely influence the value of the ABR wave latency. One of the anesthetics used for e ABR assessment, especially in animal research, is the ketamine/xylazine combination. Our objective was to determine the influence of the ketamine/xylazine anesthetic on the ABR latency values in adult gerbils. The ABRs of 12 adult gerbils injected with the anesthetic were collected on three consecutive days, or a total of six collections, namely: pre-collection and A, B, C, D, and E collections. Before each collection the gerbil was injected with a dose of ketamine (100 mg/kg)/xylazine (4 mg/kg). For the capture of the ABR, 2000 click stimuli were used with rarefaction polarity and 13 stimuli per second, 80 dBnHL intensity and in-ear phones. A statistically significant difference was observed in the latency of the V wave in the ABR of gerbils in the C and D collections compared to the pre-, A and E collections, and no difference was observed between the pre-, A, B, and E collections. We conclude that the use of ketamine/xylazine increases the latency of the V wave of the ABR after several doses injected into adult gerbils; thus clinicians should consider the use of this substance in the assessment of ABR.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

CONTEXT AND OBJECTIVE: Children and adolescents who live in situations of social vulnerability present a series of health problems. Nonetheless, affirmations that sensory and cognitive abnormalities are present are a matter of controversy. The aim of this study was to investigate aspects to auditory processing, through applying the brainstem auditory evoked potential (BAEP) and behavioral auditory processing tests to children living on the streets, and comparison with a control group. DESIGN AND SETTING: Cross-sectional study in the Laboratory of Auditory Processing, School of Medicine, Universidade de São Paulo. METHODS: The auditory processing tests were applied to a group of 27 individuals, subdivided into 11 children (7 to 10 years old) and 16 adolescents (11 to 16 years old), of both sexes, in situations of social vulnerability, compared with an age-matched control group of 10 children and 11 adolescents without complaints. The BAEP test was also applied to investigate the integrity of the auditory pathway. RESULTS: For both children and adolescents, there were significant differences between the study and control groups in most of the tests applied, with significantly worse performance in the study group, except in the pediatric speech intelligibility test. Only one child had an abnormal result in the BAEP test. CONCLUSIONS: The results showed that the study group (children and adolescents) presented poor performance in the behavioral auditory processing tests, despite their unaltered auditory brainstem pathways, as shown by their normal results in the BAEP test.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: To describe the Brainstem Auditory Evoked Potential (BAEP) results of full-term small-for-gestational-age newborns, comparing them to the results of full-term appropriate-for-gestational-age newborns, in order to verify whether the small-for-gestational-age condition is a risk indicator for retrocochlear hearing impairment. METHODS: This multicentric prospective cross-sectional study assessed 86 full-term newborns - 47 small- (Study Group) and 39 appropriate-for-gestational-age (Control Group - of both genders, with ages between 2 and 12 days. Newborns with presence of transient evoked otoacoustic emissions and type A tympanometry were included in the study. Quantitative analysis was based on the mean and standard deviation of the absolute latencies of waves I, III and V and interpeak intervals I-III, III-V and I-V, for each group. For qualitative analysis, the BAEP results were classified as normal or altered by analyzing these data considering the age range of the newborn at the time of testing. RESULTS: In the Study Group, nine of the 18 (38%) subjects with altered BAEP results had the condition of small-for-gestational-age as the only risk factor for hearing impairments. In the Control Group, seven (18%) had altered results. Female subjects from the Study Group tended to present more central alterations. In the Control Group, the male group tended to have more alterations. CONCLUSION: Full-term children born small or appropriate for gestational age might present transitory or permanent central hearing impairments, regardless of the presence of risk indicators.