951 resultados para Methods validation
Resumo:
Drug abuse is a widespread problem affecting both teenagers and adults. Nitrous oxide is becoming increasingly popular as an inhalation drug, causing harmful neurological and hematological effects. Some gas chromatography-mass spectrometry (GC-MS) methods for nitrous oxide measurement have been previously described. The main drawbacks of these methods include a lack of sensitivity for forensic applications; including an inability to quantitatively determine the concentration of gas present. The following study provides a validated method using HS-GC-MS which incorporates hydrogen sulfide as a suitable internal standard allowing the quantification of nitrous oxide. Upon analysis, sample and internal standard have similar retention times and are eluted quickly from the molecular sieve 5Å PLOT capillary column and the Porabond Q column therefore providing rapid data collection whilst preserving well defined peaks. After validation, the method has been applied to a real case of N2O intoxication indicating concentrations in a mono-intoxication.
Resumo:
BACKGROUND AND AIMS: Inflammatory bowel disease (IBD) frequently manifests during childhood and adolescence. For providing and understanding a comprehensive picture of a patients' health status, health-related quality of life (HRQoL) instruments are an essential complement to clinical symptoms and functional limitations. Currently, the IMPACT-III questionnaire is one of the most frequently used disease-specific HRQoL instrument among patients with IBD. However, there is a lack of studies examining the validation and reliability of this instrument. METHODS: 146 paediatric IBD patients from the multicenter Swiss IBD paediatric cohort study database were included in the study. Medical and laboratory data were extracted from the hospital records. HRQoL data were assessed by means of standardized questionnaires filled out by the patients in a face-to-face interview. RESULTS: The original six IMPACT-III domain scales could not be replicated in the current sample. A principal component analysis with the extraction of four factor scores revealed the most robust solution. The four factors indicated good internal reliability (Cronbach's alpha=.64-.86), good concurrent validity measured by correlations with the generic KIDSCREEN-27 scales and excellent discriminant validity for the dimension of physical functioning measured by HRQoL differences for active and inactive severity groups (p<.001, d=1.04). CONCLUSIONS: This study with Swiss children with IBD indicates good validity and reliability for the IMPACT-III questionnaire. However, our findings suggest a slightly different factor structure than originally proposed. The IMPACT-III questionnaire can be recommended for its use in clinical practice. The factor structure should be further examined in other samples.
Resumo:
Matrix effects, which represent an important issue in liquid chromatography coupled to mass spectrometry or tandem mass spectrometry detection, should be closely assessed during method development. In the case of quantitative analysis, the use of stable isotope-labelled internal standard with physico-chemical properties and ionization behaviour similar to the analyte is recommended. In this paper, an example of the choice of a co-eluting deuterated internal standard to compensate for short-term and long-term matrix effect in the case of chiral (R,S)-methadone plasma quantification is reported. The method was fully validated over a concentration range of 5-800 ng/mL for each methadone enantiomer with satisfactory relative bias (-1.0 to 1.0%), repeatability (0.9-4.9%) and intermediate precision (1.4-12.0%). From the results obtained during validation, a control chart process during 52 series of routine analysis was established using both intermediate precision standard deviation and FDA acceptance criteria. The results of routine quality control samples were generally included in the +/-15% variability around the target value and mainly in the two standard deviation interval illustrating the long-term stability of the method. The intermediate precision variability estimated in method validation was found to be coherent with the routine use of the method. During this period, 257 trough concentration and 54 peak concentration plasma samples of patients undergoing (R,S)-methadone treatment were successfully analysed for routine therapeutic drug monitoring.
Quantitative comparison of reconstruction methods for intra-voxel fiber recovery from diffusion MRI.
Resumo:
Validation is arguably the bottleneck in the diffusion magnetic resonance imaging (MRI) community. This paper evaluates and compares 20 algorithms for recovering the local intra-voxel fiber structure from diffusion MRI data and is based on the results of the "HARDI reconstruction challenge" organized in the context of the "ISBI 2012" conference. Evaluated methods encompass a mixture of classical techniques well known in the literature such as diffusion tensor, Q-Ball and diffusion spectrum imaging, algorithms inspired by the recent theory of compressed sensing and also brand new approaches proposed for the first time at this contest. To quantitatively compare the methods under controlled conditions, two datasets with known ground-truth were synthetically generated and two main criteria were used to evaluate the quality of the reconstructions in every voxel: correct assessment of the number of fiber populations and angular accuracy in their orientation. This comparative study investigates the behavior of every algorithm with varying experimental conditions and highlights strengths and weaknesses of each approach. This information can be useful not only for enhancing current algorithms and develop the next generation of reconstruction methods, but also to assist physicians in the choice of the most adequate technique for their studies.
Resumo:
BACKGROUND: Adequate pain assessment is critical for evaluating the efficacy of analgesic treatment in clinical practice and during the development of new therapies. Yet the currently used scores of global pain intensity fail to reflect the diversity of pain manifestations and the complexity of underlying biological mechanisms. We have developed a tool for a standardized assessment of pain-related symptoms and signs that differentiates pain phenotypes independent of etiology. METHODS AND FINDINGS: Using a structured interview (16 questions) and a standardized bedside examination (23 tests), we prospectively assessed symptoms and signs in 130 patients with peripheral neuropathic pain caused by diabetic polyneuropathy, postherpetic neuralgia, or radicular low back pain (LBP), and in 57 patients with non-neuropathic (axial) LBP. A hierarchical cluster analysis revealed distinct association patterns of symptoms and signs (pain subtypes) that characterized six subgroups of patients with neuropathic pain and two subgroups of patients with non-neuropathic pain. Using a classification tree analysis, we identified the most discriminatory assessment items for the identification of pain subtypes. We combined these six interview questions and ten physical tests in a pain assessment tool that we named Standardized Evaluation of Pain (StEP). We validated StEP for the distinction between radicular and axial LBP in an independent group of 137 patients. StEP identified patients with radicular pain with high sensitivity (92%; 95% confidence interval [CI] 83%-97%) and specificity (97%; 95% CI 89%-100%). The diagnostic accuracy of StEP exceeded that of a dedicated screening tool for neuropathic pain and spinal magnetic resonance imaging. In addition, we were able to reproduce subtypes of radicular and axial LBP, underscoring the utility of StEP for discerning distinct constellations of symptoms and signs. CONCLUSIONS: We present a novel method of identifying pain subtypes that we believe reflect underlying pain mechanisms. We demonstrate that this new approach to pain assessment helps separate radicular from axial back pain. Beyond diagnostic utility, a standardized differentiation of pain subtypes that is independent of disease etiology may offer a unique opportunity to improve targeted analgesic treatment.
Resumo:
BACKGROUND: The only available score to assess the risk for fatal bleeding in patients with venous thromboembolism (VTE) has not been validated yet. METHODS: We used the RIETE database to validate the risk-score for fatal bleeding within the first 3 months of anticoagulation in a new cohort of patients recruited after the end of the former study. Accuracy was measured using the ROC curve analysis. RESULTS: As of December 2011, 39,284 patients were recruited in RIETE. Of these, 15,206 had not been included in the former study, and were considered to validate the score. Within the first 3 months of anticoagulation, 52 patients (0.34%; 95% CI: 0.27-0.45) died of bleeding. Patients with a risk score of <1.5 points (64.1% of the cohort) had a 0.10% rate of fatal bleeding, those with a score of 1.5-4.0 (33.6%) a rate of 0.72%, and those with a score of >4 points had a rate of 1.44%. The c-statistic for fatal bleeding was 0.775 (95% CI 0.720-0.830). The score performed better for predicting gastrointestinal (c-statistic, 0.869; 95% CI: 0.810-0.928) than intracranial (c-statistic, 0.687; 95% CI: 0.568-0.806) fatal bleeding. The score value with highest combined sensitivity and specificity was 1.75. The risk for fatal bleeding was significantly increased (odds ratio: 7.6; 95% CI 3.7-16.2) above this cut-off value. CONCLUSIONS: The accuracy of the score in this validation cohort was similar to the accuracy found in the index study. Interestingly, it performed better for predicting gastrointestinal than intracranial fatal bleeding.
Resumo:
Background: It has been previously shown with English speaking children that food allergy clearly affects their quality of life. The first allergy quality of life questionnaire has been validated in English in 2008, however to date no questionnaire was available in French. Objectives: To validate the French version of the Food Allergy Quality of Life Questionnaire- Parent Form (FAQLQ-PF) already existing version developed and validated in English by DunnGalvin et al. Methods: The questionnaire was translated from English to French by two independent French-speaking translators and retranslated by an independent English-speaking translator. We then recruited 30 patients between 0 and 12 years with a food allergy. Parents of these children answered the questionnaire during a clinic visit. The results obtained were then analysed and compared with the results provided by DunnGalvin's study and the Food Allergy independent Measure (FAIM). Results: 27 questionnaires were fully completed and available for analysis. Median age was 6 years with a range from 18 months to 12 years. We had a girl/boy ratio of 1:1.14. A Cronbach's a correlation index of 0.748 was found. Validity was demonstrated by significant correlations between FAQLQ-PF and the FAIM. Conclusion: The French version of the FAQLQ was validated and will permit to assess degree of Quality of Life for French-speaking children with food allergy. It will be an important tool for clinical research and will allow research collaboration between French and English speaking research teams.
Resumo:
In occupational exposure assessment of airborne contaminants, exposure levels can either be estimated through repeated measurements of the pollutant concentration in air, expert judgment or through exposure models that use information on the conditions of exposure as input. In this report, we propose an empirical hierarchical Bayesian model to unify these approaches. Prior to any measurement, the hygienist conducts an assessment to generate prior distributions of exposure determinants. Monte-Carlo samples from these distributions feed two level-2 models: a physical, two-compartment model, and a non-parametric, neural network model trained with existing exposure data. The outputs of these two models are weighted according to the expert's assessment of their relevance to yield predictive distributions of the long-term geometric mean and geometric standard deviation of the worker's exposure profile (level-1 model). Bayesian inferences are then drawn iteratively from subsequent measurements of worker exposure. Any traditional decision strategy based on a comparison with occupational exposure limits (e.g. mean exposure, exceedance strategies) can then be applied. Data on 82 workers exposed to 18 contaminants in 14 companies were used to validate the model with cross-validation techniques. A user-friendly program running the model is available upon request.
Resumo:
Lymphocytic choriomeningitis virus (LCMV) is a rare cause of central nervous system disease in humans. Screening by real-time RT-PCR assay is of interest in the case of aseptic meningitis of unknown etiology. A specific LCMV real-time RT-PCR assay, based on the detection of genomic sequences of the viral nucleoprotein (NP), was developed to assess the presence of LCMV in cerebrospinal fluids (CSF) sent for viral screening to a Swiss university hospital laboratory. A 10-fold dilution series assay using a plasmid containing the cDNA of the viral NP of the LCMV isolate Armstrong (Arm) 53b demonstrated the high sensitivity of the assay with a lowest detection limit of ≤50 copies per reaction. High sensitivity was confirmed by dilution series assays in a pool of human CSF using four different LCMV isolates (Arm53b, WE54, Traub and E350) with observed detection limits of ≤10PFU/ml (Arm53b and WE54) and 1PFU/ml (Traub and E350). Analysis of 130 CSF showed no cases of acute infection. The absence of positive cases was confirmed by a published PCR assay detecting all Old World arenaviruses. This study validates a specific and sensitive real-time RT-PCR assay for the diagnosis of LCMV infections. Results showed that LCMV infections are extremely rare in hospitalized patients western in Switzerland.
Resumo:
BACKGROUND: Major depression, although frequent in primary care, is commonly hidden behind multiple physical complaints that are often the first and only reason for patient consultation. Major depression can be screened by two validated questions that are easier to use in primary care than the full DSM-IV criteria. A third question, called the "help" question, improves the specificity without apparently decreasing the sensitivity of this screening procedure. We validated the abbreviated screening procedure for major depression with and without the "help" question in primary care patients managed for a physical complaint. METHODS: This diagnostic accuracy study used data from a cohort study called SODA (for SOmatisation Depression Anxiety ) conducted by 24 general practitioners (GPs) in western Switzerland that included patients over 18 years of age with at least one physical complaint at index consultation. Major depression was identified with the full Patient Health Questionnaire. GPs were asked to screen patients for major depression with the three screening questions one year after inclusion. RESULTS: Out of 937 patients with at least one physical complaint, 751 were eligible one year after index consultation. Major depression was diagnosed in 69/724 (9.5%) patients. The sensitivity and specificity of the two-question method alone were 91.3% (95% confidence interval 81.4-96.4%) and 65.0% (95% confidence interval 61.2-68.6%), respectively. Adding the "help" question decreased the sensitivity (59.4% ; 95% confidence interval 47.0-70.9%) but improved the specificity (88.2% ; 95% confidence interval 85.4-90.5%) of the three-question method. CONCLUSIONS: The use of two screening questions for major depression was associated with high sensitivity and low specificity in primary care patients presenting a physical complaint. Adding the "help" question improved the specificity but clearly decreased the sensitivity; when using the "help" question; four out of ten patients with depression will be missed, compared to only one out of ten with the two-question method. Therefore, the "help" question is not useful as a screening question, but may help discussing management strategies.
Resumo:
We validated the polymerase chain reaction (PCR) with a composite reference standard in 61 patients clinically suspected of having mucosal leishmaniasis, 36 of which were cases and 25 were non-cases according to this reference standard. Patient classification and test application were carried out independently by two blind observers. One pair of primers was used to amplify a fragment of 120 bp in the conserved region of kDNA and another pair was used to amplify the internal transcript spacers (ITS) rDNA. PCR showed 68.6% (95% CI 59.2-72.6) sensitivity and 92% (95% CI 78.9-97.7) specificity; positive likelihood ratio: 8.6 (95% CI 2.8-31.3) and negative likelihood ratio: 0.3 (95% CI 0.3-0.5), when kDNA molecular target was amplified. The test performed better on sensitivity using this target compared to the ITS rDNA molecular target which showed 40% (95% CI 31.5-42.3) sensitivity and 96% (95% CI 84.1-99.3) specificity; positive likelihood ratio: 10 (95% CI 2.0-58.8) and negative likelihood ratio: 0.6 (95% CI 0.6-0.8). The inter-observer agreement was excellent for both tests. Based upon results obtained and due to low performance of conventional methods for diagnosing mucosal leishmaniasis, we consider PCR with kDNA as molecular target is a useful diagnostic test and the ITS rDNA molecular target is useful when the aim is to identify species.
Resumo:
A wide range of numerical models and tools have been developed over the last decades to support the decision making process in environmental applications, ranging from physical models to a variety of statistically-based methods. In this study, a landslide susceptibility map of a part of Three Gorges Reservoir region of China was produced, employing binary logistic regression analyses. The available information includes the digital elevation model of the region, geological map and different GIS layers including land cover data obtained from satellite imagery. The landslides were observed and documented during the field studies. The validation analysis is exploited to investigate the quality of mapping.
Resumo:
BACKGROUND: Anterior shoulder stabilization surgery with the arthroscopic Bankart procedure can have a high recurrence rate in certain patients. Identifying these patients to modify outcomes has become a focal point of research. PURPOSE: The Instability Shoulder Index Score (ISIS) was developed to predict the success of arthroscopic Bankart repair. Scores range from 0 to 10, with higher scores predicting a higher risk of recurrence after stabilization. The interobserver reliability of the score is not known. STUDY DESIGN: Cohort study (diagnosis); Level of evidence, 2. METHODS: This is a prospective multicenter (North America and Europe) study of patients suffering from shoulder instability and waiting for stabilization surgery. Five pairs of independent evaluators were asked to score patient instability severity with the ISIS. Patients also completed functional scores (Western Ontario Shoulder Instability Index [WOSI], Disabilities of the Arm, Shoulder and Hand-short version [QuickDASH], and Walch-Duplay test). Data on age, sex, number of dislocations, and type of surgery were collected. The test-retest method and intraclass correlation coefficient (ICC: >0.75 = good, >0.85 = very good, and >0.9 = excellent) were used for analysis. RESULTS: A total of 114 patients with anterior shoulder instability were included, of whom 89 (78%) were men. The mean age was 28 years. The ISIS was very reliable, with an ICC of 0.933. The mean number of dislocations per patient was higher in patients who had an ISIS of ≥6 (25 vs 14; P = .05). Patients who underwent more complex arthroscopic procedures such as Hill-Sachs remplissage or open Latarjet had higher preoperative ISIS outcomes, with a mean score of 4.8 versus 3.4, respectively (P = .002). There was no correlation between the ISIS and the quality-of-life questionnaires, with Pearson correlations all >0.05 (WOSI = 0.39; QuickDASH = 0.97; Walch-Duplay = 0.08). CONCLUSION: Our results show that the ISIS is reliable when used in a multicenter study with anterior traumatic instability populations. There was no correlation between the ISIS and the quality-of-life questionnaires, but surgical decisions reflected its increased use.
Resumo:
Background: Partner violence against women is a major public health problem. Although there are currently a number of validated screening and diagnostic tools that can be used to evaluate this type of violence, such tools are not available in Spain. The aim of this study is to analyze the validity and reliability of the Spanish version of the Index of Spouse Abuse (ISA). Methods: A cross-sectional study was carried out in 2005 in two health centers in Granada, Spain, in 390 women between 18 and 70 years old. Analyses of the factorial structure, internal consistency, test-retest reliability, and construct validity were conducted. Cutoff points for each subscale were also defined. For the construct validity analysis, the SF-36 perceived general health dimension, the Rosenberg Self-Esteem Scale and the Goldberg 12-item General Health Questionnaire were included. Results: The psychometric analysis shows that the instrument has good internal consistency, reproducibility, and construct validity. Conclusions: The scale is useful for the analysis of partner violence against women in both a research setting and a healthcare setting