923 resultados para MEASURING METHODS


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Based on the computer integrated and flexible laser processing system, develop the intelligent measuring sub-system. A novel model has been built to compensate the deviations of the main frame, a new-developed 3-D laser tracker system is applied to adjust the accuracy of the system. Analyzing the characteristic of all kinds of automobile dies, which is the main processing object of the laser processing system, classify the types of the surface and border needed to be measured and be processed. According to different types of surface and border, develop 2-D adaptive measuring method based on B?zier curve and 3-D adaptive measuring method based on spline curve. During the data processing, a new 3-D probe compensation method has been described in details. Some measuring experiments and laser processing experiments are carried out to testify the methods. All the methods have been applied in the computer integrated and flexible laser processing system invented by the Institute of Mechanics, CAS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Functional Electrical Stimulation (FES) is a technique that consists on applying electrical current pulses to artificially activate motor nerve fibers and produce muscle contractions to achieve functional movements. The main applications of FES are within the rehabilitation field, in which this technique is used to aid recovery or to restore lost motor functions. People that benefit of FES are usually patients with neurological disorders which result in motor dysfunctions; most common patients include stroke and spinal cord injury (SCI). Neuroprosthesis are devices that have their basis in FES technique, and their aim is to bridge interrupted or damaged neural paths between the brain and upper or lower limbs. One of the aims of neuroprosthesis is to artificially generate muscle contractions that produce functional movements, and therefore, assist impaired people by making them able to perform activities of daily living (ADL). FES applies current pulses and stimulates nerve fibers by means of electrodes, which can be either implanted or surface electrodes. Both of them have advantages and disadvantages. Implanted electrodes need open surgery to place them next to the nerve root, so these electrodes carry many disadvantages that are produced by the use of invasive techniques. In return, as the electrodes are attached to the nerve, they make it easier to achieve selective functional movements. On the contrary, surface electrodes are not invasive and are easily attached or detached on the skin. Main disadvantages of surface electrodes are the difficulty of selectively stimulating nerve fibers and uncomfortable feeling perceived by users due to sensory nerves located in the skin. Electrical stimulation surface electrode technology has improved significantly through the years and recently, multi-field electrodes have been suggested. This multi-field or matrix electrode approach brings many advantages to FES; among them it is the possibility of easily applying different stimulation methods and techniques. The main goal of this thesis is therefore, to test two stimulation methods, which are asynchronous and synchronous stimulation, in the upper limb with multi-field electrodes. To this end, a purpose-built wrist torque measuring system and a graphic user interface were developed to measure wrist torque produced with each of the methods and to efficiently carry out the experiments. Then, both methods were tested on 15 healthy subjects and sensitivity results were analyzed for different cases. Results show that there are significant differences between methods regarding sensation in some cases, which can affect effectiveness or success of FES.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Alliance for Coastal Technologies (ACT) Workshop entitled "Technologies for Measuring Currents in Coastal Environments" was held in Portland, Maine, October 26-28, 2005, with sponsorship by the Gulf of Maine Ocean Observing System (GoMOOS), an ACT partner organization. The primary goals of the event were to summarize recent trends in nearshore research and management applications for current meter technologies, identify how current meters can assist coastal managers to fulfill their regulatory and management objectives, and to recommend actions to overcome barriers to use of the technologies. The workshop was attended by 25 participants representing state and federal environmental management agencies, manufacturers of current meter technologies, and researchers from academic institutions and private industry. Common themes that were discussed during the workshop included 1) advantages and limitations of existing current measuring equipment, 2) reliability and ease of use with each instrument type, 3) data decoding and interpretation procedures, and 4) mechanisms to facilitate better training and guidance to a broad user group. Seven key recommendations, which were ranked in order of importance during the last day of the workshop are listed below. 1. Forums should be developed to facilitate the exchange of information among users and industry: a) On-line forums that not only provide information on specific instruments and technologies, but also provide an avenue for the exchange of user experiences with various instruments (i.e. problems encountered, cautions, tips, advantages, etc). (see References for manufacturer websites with links to application and technical forums at end of report) b) Regional training/meetings for operational managers to exchange ideas on methods for measuring currents and evaluating data. c) Organize mini-meetings or tutorial sessions within larger conference venues. 2. A committee of major stakeholders should be convened to develop common standards (similar to the Institute of Electrical and Electronics Engineers (IEEE) committee) that enable users to switch sensors without losing software or display capabilities. (pdf contains 28 pages)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

As is known, copepods play an important role in the nutrition of fish. Therefore with a view to facilitating research on the study of the quantitative side of feeding, there have recently appeared a considerable number of papers devoted to the development of methods for determining the wet. weight of these crustaceans. For the further facilitating of research in the nutrition of fish it would be of great interest to clarify the problem, is there not some kind of rule in the growth of the crustaceans during metamorphosis, and if there is such a rule is it not possible, to determine the length of the larvae at each stage, not by measuring them, but by using the formulae derived on the basis of these rules. This article examines the growth curves of different species of freshwater Copepoda, obtained on the basis of experimental observations in cultures or by way of measurement of mass material at all stages of development in samples from water-bodies. The authors study in particular the ratio of the mean diameter of the eggs to the mean length of the egg-bearing females.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

During the VITAL cruise in the Bay of Biscay in summer 2002, two devices for measuring the length of swimming fish were tested: 1) a mechanical crown that emitted a pair of parallel laser beams and that was mounted on the main camera and 2) an underwater auto-focus video camera. The precision and accuracy of these devices were compared and the various sources of measurement errors were estimated by repeatedly measuring fixed and mobile objects and live fish. It was found that fish mobility is the main source of error for these devices because they require that the objects to be measured are perpendicular to the field of vision. The best performance was obtained with the laser method where a video-replay of laser spots (projected on fish bodies) carrying real-time size information was used. The auto-focus system performed poorly because of a delay in obtaining focus and because of some technical problems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Measurements of adult marine fishes on the U.S. west coast are usually made using one of three methods: standard length, fork length, or total length. Each method has advantages and disadvantages. In this paper we attempt to determine whether one method is faster and/or more reliable than the other methods. We found that all three methods were comparable. There was no appreciable difference in the time it took to measure fish using the different methods. Fork length had the most reproducible results; however, it had the highest level of bias between researchers. We therefore suggest that selection of measurement type be based on what other researchers have used for the species under study. The best improvement in measurement reliability probably occurs by adequate training of personnel and not type of measurement used.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new method for measuring the coefficient of friction between nonwoven materials and the curved surface of the volar forearm has been developed and validated. The method was used to measure the coefficient of static friction for three different nonwoven materials on the normal (dry) and over-hydrated volar forearms of five female volunteers (ages 18-44). The method proved simple to run and had good repeatability: the coefficient of variation (standard deviation expressed as a percentage of the mean) for triplets of repeat measurements was usually (80 per cent of the time) less than 10 per cent. Measurements involving the geometrically simpler configuration of pulling a weighted fabric sample horizontally across a quasi-planar area of volar forearm skin proved experimentally more difficult and had poorer repeatability. However, correlations between values of coefficient of static friction derived using the two methods were good (R = 0.81 for normal (dry) skin, and 0.91 for over-hydrated skin). Measurements of the coefficient of static friction for the three nonwovens for normal (dry) and for over-hydrated skin varied in the ranges of about 0.3-0.5 and 0.9-1.3, respectively. In agreement with Amontons' law, coefficients of friction were invariant with normal pressure over the entire experimental range (0.1-8.2 kPa).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Environmental quality indicators provide resource managers with information useful to assess coastal condition and scientifically defensible decisions. Since 1984, the National Oceanic and Atmospheric Administration (NOAA), through its National Status and Trends (NS&T) Program, has provided environmental monitoring data on chemical, physical, and biological indicators of coastal environments. The program has two major monitoring components to meet its goals. The Bioeffects Assessments Program evaluates the health of bays, estuaries, and the coastal zone around the nation using the Sediment Quality Triad technique that includes measuring sediment contaminant concentrations, sediment toxicity and benthic community structure. The Mussel Watch Program is responsible for temporal coastal monitoring of contaminant concentrations by quantifying chemicals in bivalve mollusks. The NS&T Program is committed to providing the highest quality data to meet its statutory and scientific responsibilities. Data, metadata and information products are managed within the guidance protocols and standards set forth by NOAA’s Integrated Ocean Observing System (IOOS) and the National Monitoring Network, as recommended by the 2004 Ocean Action Plan. Thus, to meet these data requirements, quality assurance protocols have been an integral part of the NS&T Program since its inception. Documentation of sampling and analytical methods is an essential part of quality assurance practices. A step-by–step summary of the Bioeffects Program’s field standard operation procedures (SOP) are presented in this manual.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Kinetic measurements of amyloid growth provide insight into the free energy landscape of this supramolecular process and are crucial in the search for potent inhibitors of the main disorders with which it is associated, including Alzheimer's and Parkinson's diseases and Type II diabetes. In recent years, a new class of surface-bound biosensor assays, e.g., those based on surface plasmon resonance (SPR) and the quartz crystal microbalance (QCM) have been established as extremely valuable tools for kinetic measurements of amyloid formation. Here we describe detailed protocols of how QCM techniques can be used to monitor the elongation of amyloid fibrils in real time and to study the influence of external factors on the kinetics of amyloid growth with unprecedented accuracy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cognitive neuroscience defines the sense of agency as the experience of controlling one's own actions and, through this control, affecting the external world. We believe that the sense of personal agency is a key factor in how people experience interactions with technology. This paper draws on theoretical perspectives in cognitive neuroscience and describes two implicit methods through which personal agency can be empirically investigated. We report two experiments applying these methods to HCI problems. One shows that a new input modality - skin-based interaction - can substantially increase users' sense of agency. The second demonstrates that variations in the parameters of assistance techniques such as predictive mouse acceleration can have a significant impact on users' sense of agency. The methods presented provide designers with new ways of evaluating and refining empowering interaction techniques and interfaces, in which users experience an instinctive sense of control and ownership over their actions. Copyright 2012 ACM.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An accurate description of sound propagation in a duct is important to obtain the sound power radiating from a source in both near and far fields. A technique has been developed and applied to decompose higher-order modes of sound emitted into a duct. Traditional experiments and theory based on two-sensor methods are limited to the plane-wave contribution to the sound field at low frequency. Due to the increase in independent measurements required, a computational method has been developed to simulate sensitivities of real measurements (e.g., noise) and optimize the set-up. An experimental rig has been constructed to decompose the first two modes using six independent measurements from surface, flush-mounted microphones. Experiments were initially performed using a loudspeaker as the source for validation. Subsequently, the sound emitted by a mixed-flow fan has been investigated and compared to measurements made in accordance with the internationally standardized in-duct fan measurement method. This method utilizes large anechoic terminations and a procedure involving averaging over measurements in space and time to account for the contribution from higher-order modes. The new method does not require either of these added complications and gives detail about the underlying modal content of the emitted sound.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Detecting receptor dimerisation and other forms of clustering on the cell surface depends on methods capable of determining protein-protein separations with high resolution in the ∼10-50 nm range. However, this distance range poses a significant challenge because it is too large for fluorescence resonance energy transfer and contains distances too small for all other techniques capable of high-resolution in cells. Here we have adapted the technique of fluorophore localisation imaging with photobleaching to measure inter-receptor separations in the cellular environment. Using the epidermal growth factor receptor, a key cancer target molecule, we demonstrate ∼10 nm resolution while continuously covering the range of ∼10-80 nm. By labelling the receptor on cells expressing low receptor numbers with a fluorescent antagonist we have found inter-receptor separations all the way up from 8 nm to 59 nm. Our data are consistent with epidermal growth factor receptors being able to form homo-polymers of at least 10 receptors in the absence of activating ligands. © 2013 Needham et al.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Several assay methods were screened for viability assessment in cyanobacteria using Microcystis aeruginosa FACHB 905. Compared with fluorescent diacetate (FDA), Evan's Blue and autofluorescence, the 3-[4,5-dimethylthiazol-2-yl]2,5-diphenyl tetrazolium bromide (MTT) assay, which was based on the ability of viable cells to reduce MTT to formazan, was found to be reliable and was selected for further study. MTT concentration, incubation time and temperature were optimized for M. aeruginosa. Improvements to the sensitivity and reproducibility of the MTT assay included performing it in the dark to reduce the effects of formazan light sensitivity when extracted in DMSO. Another improvement involved collecting viability data by cell by counting rather than colourimetrically, which was concluded from the fact that oxidoreductase activity, responsible for MTT reduction, would elevate or decrease under stress conditions. Half-life of oxidoreductase in dead cell was calculated to be 3 h. The MTT assay was also found to be applicable to other cyanobacteria and diatoms, including field samples, but not for algae belonging to Chlorophyta, Euglenophyta, Pyrrophyta or Chrysophyta. Based on the above results, we proposed an optimized procedure for the MTT method on Microcystis strains. The use of this assay may be of importance to better understand the dynamics of bloom and the fate of Microcystis under natural or disturbed conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cubic boron nitride (c-BN) films were prepared by ion beam assisted deposition (IBAD) technique, and the stresses were primary estimated by measuring the frequency shifts in the infrared-absorption peaks of c-BN samples. To test the possible effects of other factors, dependencies of the c-BN transversal optical mode position on film thickness and c-BN content were investigated. Several methods for reducing the stress of c-BN films including annealing, high temperature deposition, two-stage process, and the addition of a small amount of Si were studied, in which the c-BN films with similar thickness and cubic phase content were used to evaluate the effects of the various stress relief methods. It was shown that all the methods can reduce the stress in c-BN films to various extents. Especially, the incorporation of a small amount of Si (2.3 at.%) can result in a remarkable stress relief from 8.4 to similar to 3.6 GPa whereas the c-BN content is nearly unaffected, although a slight degradation of the c-BN crystallinity is observed. The stress can be further reduced down below I GPa by combination of the addition of Si with the two-stage deposition process. (c) 2008 Elsevier B.V. All rights reserved.