932 resultados para Load test on SPT sampler


Relevância:

100.00% 100.00%

Publicador:

Resumo:

There are hundreds of structurally deficient or functionally obsolete bridges in the state of Iowa. With the majority of these bridges located on rural county roads where there is limited funding available to replace the bridges, diagnostic load testing can be utilized to determine the actual load carrying capacity of the bridge. One particular family or fleet of bridges that has been determined to be desirable for load testing consists of single-span bridges with non-composite, cast-in-place concrete decks, steel stringers, and timber substructures. Six bridges with poor performing superstructure and substructure from the aforementioned family of bridges were selected to be load tested. The six bridges were located on rural roads in five different counties in Iowa: Boone, Carroll, Humboldt, Mahaska, and Marshall. Volume I of this report focuses on evaluating the superstructure for this family of bridges. This volume discusses the behavior characteristics that influence the load carrying capacity of this fleet of bridges. In particular, the live load distribution, partial composite action, and bearing restraint were investigated as potential factors that could influence the bridge ratings. Implementing fleet management practices, the bridges were analyzed to determine if the load test results could be predicted to better analyze previously untested bridges. For this family of bridges it was found that the ratings increased as a result of the load testing demonstrating a greater capacity than determined analytically. Volume II of this report focuses on evaluating the timber substructure for this family of bridges. In this volume, procedures for detecting pile internal decay using nondestructive ultrasonic stress wave techniques, correlating nondestructive ultrasonic stress wave techniques to axial compression tests to estimate deteriorated pile residual strength, and evaluating load distribution through poor performing timber substructure elements by instrumenting and load testing the abutments of the six selected bridges are discussed. Also, in this volume pile repair methods for restoring axial and bending capacities of pile are developed and evaluated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recent data compiled by the National Bridge Inventory revealed 29% of Iowa's approximate 24,600 bridges were either structurally deficient or functionally obsolete. This large number of deficient bridges and the high cost of needed repairs create unique problems for Iowa and many other states. The research objective of this project was to determine the load capacity of a particular type of deteriorating bridge – the precast concrete deck bridge – which is commonly found on Iowa's secondary roads. The number of these precast concrete structures requiring load postings and/or replacement can be significantly reduced if the deteriorated structures are found to have adequate load capacity or can be reliably evaluated. Approximately 600 precast concrete deck bridges (PCDBs) exist in Iowa. A typical PCDB span is 19 to 36 ft long and consists of eight to ten simply supported precast panels. Bolts and either a pipe shear key or a grouted shear key are used to join adjacent panels. The panels resemble a steel channel in cross-section; the web is orientated horizontally and forms the roadway deck and the legs act as shallow beams. The primary longitudinal reinforcing steel bundled in each of the legs frequently corrodes and causes longitudinal cracks in the concrete and spalling. The research team performed service load tests on four deteriorated PCDBs; two with shear keys in place and two without. Conventional strain gages were used to measure strains in both the steel and concrete, and transducers were used to measure vertical deflections. Based on the field results, it was determined that these bridges have sufficient lateral load distribution and adequate strength when shear keys are properly installed between adjacent panels. The measured lateral load distribution factors are larger than AASHTO values when shear keys were not installed. Since some of the reinforcement had hooks, deterioration of the reinforcement has a minimal affect on the service level performance of the bridges when there is minimal loss of cross-sectional area. Laboratory tests were performed on the PCDB panels obtained from three bridge replacement projects. Twelve deteriorated panels were loaded to failure in a four point bending arrangement. Although the panels had significant deflections prior to failure, the experimental capacity of eleven panels exceeded the theoretical capacity. Experimental capacity of the twelfth panel, an extremely distressed panel, was only slightly below the theoretical capacity. Service tests and an ultimate strength test were performed on a laboratory bridge model consisting of four joined panels to determine the effect of various shear connection configurations. These data were used to validate a PCDB finite element model that can provide more accurate live load distribution factors for use in rating calculations. Finally, a strengthening system was developed and tested for use in situations where one or more panels of an existing PCDB need strengthening.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In response to the mandate on Load and Resistance Factor Design (LRFD) implementations by the Federal Highway Administration (FHWA) on all new bridge projects initiated after October 1, 2007, the Iowa Highway Research Board (IHRB) sponsored these research projects to develop regional LRFD recommendations. The LRFD development was performed using the Iowa Department of Transportation (DOT) Pile Load Test database (PILOT). To increase the data points for LRFD development, develop LRFD recommendations for dynamic methods, and validate the results of LRFD calibration, 10 full-scale field tests on the most commonly used steel H-piles (e.g., HP 10 x 42) were conducted throughout Iowa. Detailed in situ soil investigations were carried out, push-in pressure cells were installed, and laboratory soil tests were performed. Pile responses during driving, at the end of driving (EOD), and at re-strikes were monitored using the Pile Driving Analyzer (PDA), following with the CAse Pile Wave Analysis Program (CAPWAP) analysis. The hammer blow counts were recorded for Wave Equation Analysis Program (WEAP) and dynamic formulas. Static load tests (SLTs) were performed and the pile capacities were determined based on the Davisson’s criteria. The extensive experimental research studies generated important data for analytical and computational investigations. The SLT measured load-displacements were compared with the simulated results obtained using a model of the TZPILE program and using the modified borehole shear test method. Two analytical pile setup quantification methods, in terms of soil properties, were developed and validated. A new calibration procedure was developed to incorporate pile setup into LRFD.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Many state, county, and local agencies are faced with deteriorating bridge infrastructure composed of a large percentage of relatively short to medium span bridges. In many cases, these older structures are rolled or welded longitudinal steel stringers acting compositely with a reinforced concrete deck. Most of these bridges, although still in service, need some level of strengthening due to increases in legal live loads or loss of capacity due to deterioration. Although these bridges are overstressed in most instances, they do not warrant replacement; thus, structurally efficient but cost-effective means of strengthening needs to be employed. In the past, the use of bolted steel cover plates or angles was a common retrofit option for strengthening such bridges. However, the time and labor involved to attach such a strengthening system can sometimes be prohibitive. This project was funded through the Federal Highway Administration’s Innovative Bridge Research and Construction program. The goal is to retrofit an existing structurally deficient, three-span continuous steel stringer bridge using an innovative technique that involves the application of post-tensioning forces; the post-tensioning forces were applied using fiber reinforced polymer post-tensioning bars. When compared to other strengthening methods, the use of carbon fiber reinforced polymer composite materials is very appealing in that they are highly resistant to corrosion, have a low weight, and have a high tensile strength. Before the post-tensioning system was installed, a diagnostic load test was conducted on the subject bridge to establish a baseline behavior of the unstrengthened bridge. During the process of installing the post-tensioning hardware and stressing the system, both the bridge and the post-tensioning system were monitored. The installation of the hardware was followed by a follow-up diagnostic load test to assess the effectiveness of the post-tensioning strengthening system. Additional load tests were performed over a period of two years to identify any changes in the strengthening system with time. Laboratory testing of several typical carbon fiber reinforced polymer bar specimens was also conducted to more thoroughly understand their behavior. This report documents the design, installation, and field testing of the strengthening system and bridge.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Discussion on improving the power of genome-wide association studies to identify candidate variants and genes is generally centered on issues of maximizing sample size; less attention is given to the role of phenotype definition and ascertainment. The authors used genome-wide data from patients infected with human immunodeficiency virus type 1 (HIV-1) to assess whether differences in type of population (622 seroconverters vs. 636 seroprevalent subjects) or the number of measurements available for defining the phenotype resulted in differences in the effect sizes of associations between single nucleotide polymorphisms and the phenotype, HIV-1 viral load at set point. The effect estimate for the top 100 single nucleotide polymorphisms was 0.092 (95% confidence interval: 0.074, 0.110) log(10) viral load (log(10) copies of HIV-1 per mL of blood) greater in seroconverters than in seroprevalent subjects. The difference was even larger when the authors focused on chromosome 6 variants (0.153 log(10) viral load) or on variants that achieved genome-wide significance (0.232 log(10) viral load). The estimates of the genetic effects tended to be slightly larger when more viral load measurements were available, particularly among seroconverters and for variants that achieved genome-wide significance. Differences in phenotype definition and ascertainment may affect the estimated magnitude of genetic effects and should be considered in optimizing power for discovering new associations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tämän diplomityön oleellisempana tavoitteena oli tutkia ioninvaihtohartsien pitkäaikaista toiminnallista lämpötilakestävyyttä kirjallisuustutkimuksin ja kuormituskokein. Lisaksi työssä optimoitiin taloudellisesti ja teknisesti paras kytkentävaihtoehto soodakattilan lauhteenpuhdistuslaitokselle. Tässä diplomityössä selvitettiin myös soodakattilan ulospuhallusveden sisältämien veden jälkiannostelukemikaalien ja epäpuhtauksien vaikutusta ioninvaihtohartsien vanhenemiseen.; Ioninvaihtohartsien lämpötilakestävyyteen liittyvät koeajot suoritettiin Stora Enso Laminating Papers Oy Kotkan tehtaalla. Koeajoja varten oli erikseen suunniteltu koeajolaitteisto, jossa lauhdenäytettä puhdistettiin patruunasuotimella ja sekavaihtimella. Sekavaihtimessa käytettiin vahvoja anioni- ja kationihartseja. Koeajoja oli yhteensä neljäkappaletta ja niissä tutkittiin hartsien lämpötilakestävyyttä ja anionihartsin silikaatti-vuodon riippuvuutta lämpötilasta. Lämpötilakestävyyskoeajoissa käytetyt hartsit lähetettiin Rohm and Haasille analysoitavaksi. Lopulta koeajojen tuloksia verrattiin kirjallisuudessa esitettyihin aikaisempiin tutkimuksiin. Lauhteenpuhdistuslaitoksen kytkentävaihtoehtojen optimoinnissa käytettiin apuna Kotkan ja UPM-Kymmene Oyj Pietarsaaren tehtaiden kokemuksia. Kytkentävaihtoehtojen energiataseet laskettiin kuudelle eri laitokselle, joiden syöttöveden virtaukset olivat 37 -180 kg/s. Lisaksi selvitettiin kytkentävaihtoehtojen investointikustannukset ja kertakäyttöhartsien vuotuiset kustannukset laitokselle, jossa syöttöveden virtaus oli 67 kg/s. Ulospuhalluksen talteenottojärjestelmän energiataseet laskettiin kuudelle eri laitokselle, joiden syöttöveden virtaukset olivat 37 - 180 kg/s. Laskelmien lähtökohtana käytettiin kunkin soodakattilan ulospuhallusveden määriä, jotka selvitettiin tehdasvierailujen yhteydessä. Ulospuhallusveden epäpuhtauksien ja jälkiannostelukemikaalien pitoisuudet arvioitiin kattilaveden perusteella. Aikaisempien kokemusten perusteella arvioitiin, että ulospuhallusvesi johdettaisiin lisäveden valmistukseen ennen suolanpoistosarjoja. loninvaihtohartsien kuormituskokeiden ja kirjallisuustutkimusten perusteella oli selkeästi nähtävissä, että etenkin anionihartsin kapasiteetti heikkeni nopeasti lämpötilan ollessa yli 60 °C. Kationihartsin suolanpoistolle kriittinen lämpötilaraja on 100 °C.Lisäksi yli 60 °C:ssa anionihartsi ei pysty poistamaan silikaattia lauhteesta. Seuraavaksi on esitelty lauhteenpuhdistuslaitoksen optimikytkentävaihtoehdot sekä vanhoille että uusille laitoksille. Vanhalle laitokselle, jossa lauhteet on puhdistettu aikaisemmin mekaanisella suotimella ja lisäveden puhdistuksessa on käytetty sekavaihdinta, paras kytkentävaihto on erilliset sekavaihtimet lauhteelle ja lisävedelle. Uudelle ja vanhalle laitokselle, jossa lauhteet on puhdistettu aikaisemmin mekaanisella suotimella ja lisäveden puhdistuksessa ei ole käytetty sekavaihdinta, paras kytkentävaihto on yhteiset sekavaihtimet lauhteelle ja lisävedelle. Lauhteen puhdistuksessa käytetyt sekavaihtimen toimintalämpötila on 45 °C molemmissa kytkentävaihtoehdoissa. Kertakäyttöhartsien käyttö osoittautui suuressa mittakaavassa kannattamattomaksi. Tämä asia tarvinnee kuitenkin jatkotutkimuksia. Ulospuhallusveden talteenotolla saadaan energiasäästöä 6-53 k¤/a riippuenlaitoksesta. Etenkin soodakattilalaitoksissa, joissa soodakattila ja vedenkäsittelylaitos sijaitsevat lähellä toisiaan, kannattaa ulospuhallusvesi johtaa lisäveden valmistukseen. Jos edellä mainittujen laitosten etäisyydet kasvavat, saattavat ulospuhallusjärjestelmän investointi-kustannukset nousta kohtuuttoman suureksi. Tämä työ osoitti myös, että ulospuhallusveden epäpuhtauksilla ei ole merkittävää vaikutusta kemiallisesti puhdistetun veden laatuun ennen suolanpoistolaitosta ja ioninvaihtohartsien vanhenemiseen.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fatigue life assessment of weldedstructures is commonly based on the nominal stress method, but more flexible and accurate methods have been introduced. In general, the assessment accuracy is improved as more localized information about the weld is incorporated. The structural hot spot stress method includes the influence of macro geometric effects and structural discontinuities on the design stress but excludes the local features of the weld. In this thesis, the limitations of the structural hot spot stress method are discussed and a modified structural stress method with improved accuracy is developed and verified for selected welded details. The fatigue life of structures in the as-welded state consists mainly of crack growth from pre-existing cracks or defects. Crack growth rate depends on crack geometry and the stress state on the crack face plane. This means that the stress level and shape of the stress distribution in the assumed crack path governs thetotal fatigue life. In many structural details the stress distribution is similar and adequate fatigue life estimates can be obtained just by adjusting the stress level based on a single stress value, i.e., the structural hot spot stress. There are, however, cases for which the structural stress approach is less appropriate because the stress distribution differs significantly from the more common cases. Plate edge attachments and plates on elastic foundations are some examples of structures with this type of stress distribution. The importance of fillet weld size and weld load variation on the stress distribution is another central topic in this thesis. Structural hot spot stress determination is generally based on a procedure that involves extrapolation of plate surface stresses. Other possibilities for determining the structural hot spot stress is to extrapolate stresses through the thickness at the weld toe or to use Dong's method which includes through-thickness extrapolation at some distance from the weld toe. Both of these latter methods are less sensitive to the FE mesh used. Structural stress based on surface extrapolation is sensitive to the extrapolation points selected and to the FE mesh used near these points. Rules for proper meshing, however, are well defined and not difficult to apply. To improve the accuracy of the traditional structural hot spot stress, a multi-linear stress distribution is introduced. The magnitude of the weld toe stress after linearization is dependent on the weld size, weld load and plate thickness. Simple equations have been derived by comparing assessment results based on the local linear stress distribution and LEFM based calculations. The proposed method is called the modified structural stress method (MSHS) since the structural hot spot stress (SHS) value is corrected using information on weld size andweld load. The correction procedure is verified using fatigue test results found in the literature. Also, a test case was conducted comparing the proposed method with other local fatigue assessment methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The future of high technology welded constructions will be characterised by higher strength materials and improved weld quality with respect to fatigue resistance. The expected implementation of high quality high strength steel welds will require that more attention be given to the issues of crack initiation and mechanical mismatching. Experiments and finite element analyses were performed within the framework of continuum damage mechanics to investigate the effect of mismatching of welded joints on void nucleation and coalescence during monotonic loading. It was found that the damage of undermatched joints mainly occurred in the sandwich layer and the damageresistance of the joints decreases with the decrease of the sandwich layer width. The damage of over-matched joints mainly occurred in the base metal adjacent to the sandwich layer and the damage resistance of the joints increases with thedecrease of the sandwich layer width. The mechanisms of the initiation of the micro voids/cracks were found to be cracking of the inclusions or the embrittled second phase, and the debonding of the inclusions from the matrix. Experimental fatigue crack growth rate testing showed that the fatigue life of under-matched central crack panel specimens is longer than that of over-matched and even-matched specimens. Further investigation by the elastic-plastic finite element analysis indicated that fatigue crack closure, which originated from the inhomogeneousyielding adjacent to the crack tip, played an important role in the fatigue crack propagation. The applicability of the J integral concept to the mismatched specimens with crack extension under cyclic loading was assessed. The concept of fatigue class used by the International Institute of Welding was introduced in the parametric numerical analysis of several welded joints. The effect of weld geometry and load condition on fatigue strength of ferrite-pearlite steel joints was systematically evaluated based on linear elastic fracture mechanics. Joint types included lap joints, angle joints and butt joints. Various combinations of the tensile and bending loads were considered during the evaluation with the emphasis focused on the existence of both root and toe cracks. For a lap joint with asmall lack-of-penetration, a reasonably large weld leg and smaller flank angle were recommended for engineering practice in order to achieve higher fatigue strength. It was found that the fatigue strength of the angle joint depended strongly on the location and orientation of the preexisting crack-like welding defects, even if the joint was welded with full penetration. It is commonly believed that the double sided butt welds can have significantly higher fatigue strength than that of a single sided welds, but fatigue crack initiation and propagation can originate from the weld root if the welding procedure results in a partial penetration. It is clearly shown that the fatigue strength of the butt joint could be improved remarkably by ensuring full penetration. Nevertheless, increasing the fatigue strength of a butt joint by increasing the size of the weld is an uneconomical alternative.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The impact of round-the-clock cerebrospinal fluid (CSF) Gram stain on overnight empirical therapy for suspected central nervous system (CNS) infections was investigated. All consecutive overnight CSF Gram stains between 2006 and 2011 were included. The impact of a positive or a negative test on empirical therapy was evaluated and compared to other clinical and biological indications based on institutional guidelines. Bacterial CNS infection was documented in 51/241 suspected cases. Overnight CSF Gram stain was positive in 24/51. Upon validation, there were two false-positive and one false-negative results. The sensitivity and specificity were 41 and 99 %, respectively. All patients but one had other indications for empirical therapy than Gram stain alone. Upon obtaining the Gram result, empirical therapy was modified in 7/24, including the addition of an appropriate agent (1), addition of unnecessary agents (3) and simplification of unnecessary combination therapy (3/11). Among 74 cases with a negative CSF Gram stain and without formal indication for empirical therapy, antibiotics were withheld in only 29. Round-the-clock CSF Gram stain had a low impact on overnight empirical therapy for suspected CNS infections and was associated with several misinterpretation errors. Clinicians showed little confidence in CSF direct examination for simplifying or withholding therapy before definite microbiological results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS: There is no standard test to determine the fatigue resistance of denture teeth. With the increasing number of patients with implant-retained dentures the mechanical strength of the denture teeth requires more attention and valid laboratory test set-ups. The purpose of the present study was to determine the fatigue resistance of various denture teeth using a dynamic load testing machine. METHODS: Four denture teeth were used: Bonartic II (Candulor), Physiodens (Vita), SR Phonares II (Ivoclar Vivadent) and Trubyte (Dentsply). For dynamic load testing, first upper molars with a similar shape and cusp inclination were selected. The molar teeth were embedded in cylindrical steel molds with denture base material (ProBase, Ivoclar Vivadent). Dynamic fatigue loading was carried out on the mesio-buccal cusp at a 45° angle using dynamic testing machines and 2,000,000 cycles at 2Hz in water (37°C). Three specimens per group and load were submitted to decreasing load levels (at least 4) until all the three specimens no longer showed any failures. All the specimens were evaluated under a stereo microscope (20× magnification). The number of cycles reached before observing a failure, and its dependence on the load and on the material, has been modeled using a parametric survival regression model with a lognormal distribution. This allowed to estimate the fatigue resistance for a given material as the maximal load for which one would observe less than 1% failure after 2,000,000 cycles. RESULTS: The failure pattern was similar for all denture teeth, showing a large chipping of the loaded mesio-buccal cusp. In our regression model, there were statistically significant differences among the different materials, with SR Phonares II and Bonartic II showing a higher resistance than Physiodens and Trubyte, the fatigue resistance being estimated at around 110N for the former two, and at about 60N for the latter two materials. CONCLUSION: The fatigue resistance may be a useful parameter to assess and to compare the clinical risk of chipping and fracture of denture tooth materials.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

L’objecte del present estudi és caracteritzar el temps de vol (Tv) de la fase aèria en l’exercici d’arrencada en halterofília. Es descriu el seu comportament en funció de l’increment progressiu de la càrrega i en relació a variables biomecàniques de l’estirada, així com la seva evolució en un cicle d’entrenament. Es va fer un test màxim de càrregues progressives amb set halterofilistes (n = 7) de competició. Mitjançant els sistemes de valoració Musclelab i Chronojump es van registrar els valors de: força (F), potència (P), velocitat (V), pic de velocitat (pV) i alçada relativa (Hrel ) de la barra en l’estirada, al costat del Tv del desplaçament dels peus de l’aixecador a l’entrada sota la barra. Es va observar una moderada correlació negativa (r = –0,561; p < 0,01) entre el Tv i la càrrega màxima del test (%1RMT). No es van trobar correlacions significatives per al Tv respecte a la resta de variables analitzades. El Tv disminuïa amb l’increment de la càrrega en rangs submàxims, i era de natura aleatòria amb l’ocupació de càrregues màximes. En un subgrup de la mostra (n = 4) es van valorar les mateixes variables passades vuit setmanes. El Tv, la Pmàx i el pV suggereixen ser variables suficientment sensibles per monitoritzar els canvis generats per l’entrenament en vuit setmanes, encara que la reduïda dimensió mostral no va permetre aconseguir diferències significatives. Aquests resultats destaquen la possibilitat de considerar el Tv i la P com a mesures de control en l’entrenament d’halterofilistes, preferentment en l’ús de càrregues submàximes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Winter dysentery (WD) is a seasonal infectious disease described worldwide that causes a marked decrease in milk production in dairy cows. In the Northern hemisphere, where the disease is classically recognized, bovine coronavirus (BCoV) has been assigned as a major etiologic agent of the disease. Nonetheless, in the Southern hemisphere, an in-deep etiological survey on WD cases had not been carried out. This study aimed to survey for BCoV by nested-RT-PCR, rotavirus by polyacrylamide gel electrophoresis (PAGE) and ELISA, bacteria by classical bacteriological methods and PCR for virulence factors and parasites by sugar flotation test on fecal samples of 21 cows from a farm during an outbreak of WD in São Paulo state, Southeastern Brazil. BCoV was detected in all 21 samples, while rotavirus was detected in two symptomatic cows. Escherichia coli, Yersinia intermedia, Providencia rustigianii Proteus penneri, Klebsiella terrigena and Enterobacter aglomerans were detected in samples from both asymptomatic and healthy cows in different associations. The study of E. coli virulence factors revealed that the strains isolated were all apathogenic. Cysts of Eimeria sp. and eggs of Strongyloidea were detected at low numbers in four of the symptomatic cows, with one co-infestation. These results suggest BCoV as the main etiologic agent of the cases of WD in Brazil, a conclusion that, with the clinical and epidemiological patterns of the disease studied herein, match those already described elsewhere. These findings give basis to the development of preventive measures and contribute to the understanding of the etiology of WD.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

the response to an oral calcium load test was assessed in 17 hypercalciuric nephrolithiasis patients who presented elevated parathyroid hormone (PTH) irrespective of the ionized calcium (sCa2+) levels. Blood samples were collected at baseline (0 min) and at 60 and 180 min after 1 g calcium load for serum PTH, total calcium, sCa2+, and 1.25(OH)2D3 determinations. According to the sCa2+ level at baseline, patients were classified as normocalcemic (N = 9) or hypercalcemic (N = 8). Six healthy subjects were also evaluated as controls. Bone mineral density was reduced in 14/17 patients. In the normocalcemic group, mean PTH levels at 0, 60 and 180 min (95 ± 76, 56 ± 40, 57 ± 45 pg/ml, respectively) did not differ from the hypercalcemic group (130 ± 75, 68 ± 35, 80 ± 33 pg/ml) but were significantly higher compared to healthy subjects despite a similar elevation in sCa2+ after 60 and 180 min vs baseline in all 3 groups. Mean total calcium and 1.25(OH)2D3 were similar in the 3 groups. Additionally, we observed that 5 of 9 normocalcemic patients presented a significantly higher concentration-time curve for serum PTH (AUC0',60',180') than the other 4 patients and the healthy subjects, suggesting a primary parathyroid dysfunction. These data suggest that the individual response to an oral calcium load test may be a valuable dynamic tool to disclose a subtle primary hyperparathyroidism in patients with high PTH and fluctuating sCa2+ levels, avoiding repeated measurements of both parameters.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We evaluated vascular reactivity after a maximal exercise test in order to determine whether the effect of exercise on the circulation persists even after interruption of the exercise. Eleven healthy sedentary volunteers (six women, age 28 ± 5 years) were evaluated before and after (10, 60, and 120 min) a maximal exercise test on a treadmill. Forearm blood flow (FBF) was measured by venous occlusion plethysmography before and during reactive hyperemia (RH). Baseline FBF, analyzed by the area under the curve, increased only at 10 min after exercise (P = 0.01). FBF in response to RH increased both at 10 and 60 min vs baseline (P = 0.004). Total excess flow for RH above baseline showed that vascular reactivity was increased up to 60 min after exercise (mean ± SEM, before: 526.4 ± 48.8; 10 min: 1053.0 ± 168.2; 60 min: 659.4 ± 44.1 ml 100 ml-1 min-1 . s; P = 0.01 and 0.02, respectively, vs before exercise). The changes in FBF were due to increased vascular conductance since mean arterial blood pressure did not change. In a time control group (N = 5, 34 ± 3 years, three women) that did not exercise, FBF and RH did not change significantly (P = 0.07 and 0.7, respectively). These results suggest that the increased vascular reactivity caused by chronic exercise may result, at least in part, from a summation of the subacute effects of successive exercise bouts.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to verify the association between the contribution of energy systems during an incremental exercise test (IET), pacing, and performance during a 10-km running time trial. Thirteen male recreational runners completed an incremental exercise test on a treadmill to determine the respiratory compensation point (RCP), maximal oxygen uptake (V˙O2max), peak treadmill speed (PTS), and energy systems contribution; and a 10-km running time trial (T10-km) to determine endurance performance. The fractions of the aerobic (WAER) and glycolytic (WGLYCOL) contributions were calculated for each stage based on the oxygen uptake and the oxygen energy equivalents derived by blood lactate accumulation, respectively. Total metabolic demand (WTOTAL) was the sum of these two energy systems. Endurance performance during the T10-km was moderately correlated with RCP, V˙O2maxand PTS (P<@0.05), and moderate-to-highly correlated with WAER, WGLYCOL, and WTOTAL (P<0.05). In addition, WAER, WGLYCOL, and WTOTAL were also significantly correlated with running speed in the middle (P<0.01) and final (P<0.01) sections of the T10-km. These findings suggest that the assessment of energy contribution during IET is potentially useful as an alternative variable in the evaluation of endurance runners, especially because of its relationship with specific parts of a long-distance race.