956 resultados para LOW-VOLUME VENTILATION
Resumo:
A simple procedure was developed for packing PicoFrit HPLC columns with chromatographic stationary phase using a reservoir fabricated from standard laboratory HPLC fittings. Packed columns were mounted onto a stainless steel ultra-low volume precolumn filter assembly containing a 0.5-mu m pore size steel frit. This format provided a conduit for the application of the nanospray voltage and protected the column from obstruction by sample material. The system was characterised and operational performance assessed by analysis of a range of peptide standards (n = 9).
Resumo:
Sponge cakes have traditionally been manufactured using multistage mixing methods to enhance potential foam formation by the eggs. Today, use of all-in (single-stage) mixing methods is superseding multistage methods for large-scale batter preparation to reduce costs and production time. In this study, multistage and all-in mixing procedures and three final high-speed mixing times (3, 5, and 15 min) for sponge cake production were tested to optimize a mixing method for pilot-scale research. Mixing for 3 min produced batters with higher relative density values than did longer mixing times. These batters generated well-aerated cakes with high volume and low hardness. In contrast, after 5 and 15 min of high-speed mixing, batters with lower relative density and higher viscosity values were produced. Although higher bubble incorporation and retention were observed, longer mixing times produced better developed gluten networks, which stiffened the batters and inhibited bubble expansion during mixing. As a result, these batters did not expand properly and produced cakes with low volume, dense crumb, and high hardness values. Results for all-in mixing were similar to those for the multistage mixing procedure in terms of the physical properties of batters and cakes (i.e., relative density, elastic moduli, volume, total cell area, hardness, etc.). These results suggest the all-in mixing procedure with a final high-speed mixing time of 3 min is an appropriate mixing method for pilot-scale sponge cake production. The advantages of this method are reduced energy costs and production time.
Resumo:
Esta dissertação investigou, no mercado brasileiro, se o atraso no ajuste de preços das ações de baixa liquidez gera previsibilidade do retorno dessas ações quando comparadas às mais líquidas. O interesse estava em confrontar os resultados com os existentes na literatura internacional que apresentavam esse efeito. Para tanto, utilizamos a metodologia proposta no artigo “Trading volume and cross-autocorrelations in stock returns”, de Chordia e Swaminathan (2000), onde foi analisada a Bolsa de Valores de Nova York (NYSE). Verificamos que, na Bolsa de Valores de São Paulo (BOVESPA), uma vez controlados pelo tamanho das empresas, os retornos, sejam diários ou semanais, de portfólios com maior liquidez antecipam os retornos dos portfólios de menor liquidez, mais explicitamente nos quartis com pequenas e médias empresas. Os efeitos de não sincronia nas negociações e as autocorrelações próprias não são suficientes para explicar os padrões de antecipação-defasagem observados nos retornos das ações, já que esses são mais significativamente influenciados pelo volume negociado. As diferenças na velocidade da incorporação de novas informações aos preços ocorrem porque as ações menos líquidas parecem responder mais lentamente a informações de mercado, pelo menos nos portfólios de empresas de menor tamanho. Dessa maneira, podemos afirmar que no Brasil, assim como nos Estados Unidos, a baixa liquidez induz um atraso no ajuste de preços das ações de pequenas e médias empresas capaz de gerar previsibilidade dos retornos dessas ações, sugerindo alguma ineficiência do mercado. Os resultados são interessantes, já que indicam que, tanto no mercado nacional quanto nos de países desenvolvidos, os volumes negociados possuem um papel significativo na velocidade em que os preços se ajustam, jogando uma luz sobre como eles podem se tornar mais eficientes.
Resumo:
Leishmania infantum and Trypanosoma cruzi are trypanosomatids of medical importance and are, respectively, the etiologic agents of visceral leishmaniasis (VL) and Chagas disease (CD) in Brazil. People infected with L. infantum or T. cruzi may develop asymptomatically, enabling the transmission of pathogens through blood transfusion and / or organs. The assessment of the infection by T. cruzi is included among the tests performed for screening blood donors in Brazil, however, there is no availability of tests for Leishmania. Serological tests for T. cruzi are very sensitive, but not specific, and may have cross-reactions with other microorganisms. Thus, the aim of this study was to determine the prevalence of Leishmania infection in blood donors and assess whether the serological test for T. cruzi detect L. infantum. Among the 300 blood samples from donors, discarded in 2011, 61 were T. cruzi positive, 203 were from donors with other infections and 36 were from handbags with low blood volume, but without infection. We also assessed 144 samples from donors without infections and able to donate blood, totaling 444 subjects. DNA was extracted from blood samples of all to perform quantitative PCR (qPCR) to detect Leishmania DNA. The buffy coat obtained from all samples was grown in Schneider medium supplemented and NNN. All samples were evaluated for the presence of anti-Leishmania antibody. The serological results indicate a percentage of 22% of Leishmania infection in blood samples obtained from discarded bags. A total of 60% of samples positive in ELISA for T. cruzi were negative by IFI, used as confirmatory test, ie 60% false positive for Chagas. Among these samples false positive for Chagas, 72% were positive by ELISA for Leishmania characterizing the occurrence of cross reaction between serologic assays. Of the 300 cultures performed, 18 grew parasites that were typed by qPCR and specific isoenzymes, found the species Leishmania infantum crops. Among the 18 cultures, 4 were purged from scholarships for low volume and all negative serology blood bank, thus demonstrating that there is a real risk of Leishmania transmission via transfusion. It is concluded that in an area endemic for leishmaniasis in Brazil, serological diagnosis performed to detect infection by T. cruzi among blood donors can identify infection by L. infantum and although cause false positive for Chagas, this cross-reactivity reduces the risk of Leishmania infection via blood transfusion, since tests are not applied specific detection of the parasite. In this way, there remains the need to discuss the implementation of a specific serological screening test for Leishmania in endemic countries such as Brazil
Resumo:
A possibilidade do desenvolvimento de técnicas de aplicação de produtos fitossanitários mais seguras, com menores volumes de calda, número de aplicações e deriva, aliados à necessidade de se obter melhores níveis de controle dos agentes nocivos às plantas cultivadas, justificam o uso da assistência de ar junto à barra de pulverização. Com o objetivo de avaliar a deposição da pulverização na cultura do feijoeiro (Phaseolus vulgaris), em presença e ausência da assistência de ar junto à barra de pulverização, com diferentes pontas de pulverização e volumes de calda, foi conduzido um experimento em delineamento inteiramente casualizado, utilizando-se como traçador o óxido cuproso. Alvos artificiais (papel filtro com 3 x 3 cm) foram afixados nas superfícies adaxial e abaxial de folíolos posicionados nos terços superior e inferior de plantas, selecionadas ao acaso, distribuídas perpendicularmente ao deslocamento do pulverizador. Após a aplicação do traçador os coletores foram lavados individualmente em solução extratora de ácido nítrico a 1,0 mol L-1. A determinação quantitativa dos depósitos foi realizada com o uso da espectrofotometria de absorção atômica. A assistência de ar junto à barra de pulverização não aumentou a deposição do traçador em folíolos de feijoeiro, aos 48 dias após a emergência da cultura.
Resumo:
This paper presents a 2kW single-phase high power factor boost rectifier with four cells in interleave connection, operating in critical conduction mode, and employing a soft-switching technique, controlled by Field Programmable Gate Array (FPGA). The soft-switching technique Is based on zero-current-switching (ZCS) cells, providing ZC (zero-current) turn-on and ZCZV (zero-current-zero-voltage) turn-off for the active switches, and ZV (zero-voltage) turn-on and ZC (zero-current) turn-off for the boost diodes. The disadvantages related 'to reverse recovery effects of boost diodes operated in continuous conduction mode (additional losses, and electromagnetic interference (EMI) problems) are minimized, due to the operation in critical conduction mode. In addition, due to the Interleaving technique, the rectifer's features include the reduction in the input current ripple, the reduction in the output voltage ripple, the use of low stress devices, low volume for the EMI input filter, high input power factor (PF), and low total harmonic distortion (THD) In the input current, in compliance with the TEC61000-3-2 standards. The digital controller has been developed using a hardware description language (VHDL) and implemented using a XC2S200E-SpartanII-E/Xilinx FPGA device, performing a true critical conduction operation mode for four interleaved cells, and a closed-loop to provide the output voltage regulation, like as a pre-regulator rectifier. Experimental results are presented for a 2kW implemented prototype with four interleaved cells, 400V nominal output voltage and 220V(rms) nominal input voltage, in order to verify the feasibility and performance of the proposed digital control through the use of a FPGA device.
Resumo:
A novel single-phase voltage source rectifier capable to achieve High-Power-Factor (HPF) for variable speed refrigeration system application, is proposed in this paper. The proposed system is composed by a single-phase high-power-factor boost rectifier, with two cells in interleave connection, operating in critical conduction mode, and employing a soft-switching technique, controlled by a Field Programmable Gate Array (FPGA), associated with a conventional three-phase IGBT bridge inverter (VSI - Voltage Source Inverter), controlled by a Digital Signal Processor (DSP). The soft-switching technique for the input stage is based on zero-current-switching (ZCS) cells. The rectifier's features include the reduction in the input current ripple, the reduction in the output voltage ripple, the use of low stress devices, low volume for the EMI input filter, high input power factor (PF), and low total harmonic distortion (THD) in the input current, in compliance with the EEC61000-3-2 standards. The digital controller for the output stage has been developed using a conventional voltage-frequency control (scalar V/f control), and a simplified stator oriented Vector control, in order to verify the feasibility and performance of the proposed digital controls for continuous temperature control applied at a refrigerator prototype.
Resumo:
Objective-To compare the ability of a sidestream capnograph and a mainstream capnograph to measure end-tidal CO2 (ETCO2) and provide accurate estimates of Paco(2) in mechanically ventilated dogs.Design-Randomized, double Latin square.Animals-6 healthy adult dogs.Procedure-Anesthesia was induced and neuromuscular blockade achieved by IV administration of pancuronium bromide. Mechanical ventilation was used to induce conditions of standard ventilation, hyperventilation, and hypoventilation. While tidal volume was held constant, changes in minute volume ventilation and Paco(2) were made by changing the respiratory rate. Arterial blood gas analysis was performed and ETCO2 measurements were obtained by use of either a mainstream or a sidestream capnographic analyzer.Results-A linear regression model and bias analysis were used to compare Paco(2) and ETCO2 measurements; ETCO2 measurements obtained by both capnographs correlated well with Paco(2). Compared with Paco(2), mainstream ETCO2 values differed by 3.15 +/- 4.89 mm Hg (mean bias +/- SD), whereas the bias observed with the sidestream ETCO2 system was significantly higher (5.65 +/- 5.57 mm Hg). Regardless of the device used to measure ETCO2, bias increased as Paco(2) exceeded 60 mm Hg.Conclusions and Clinical Relevance-Although the mainstream capnograph was slightly more accurate, both methods of ETCO2 measurement correlated well with Paco(2) and reflected changes in the ventilatory status. However, ETCO2 values > 45 mm Hg may inaccurately reflect the severity of hypoventilation as Paco(2) may be underestimated during conditions of hypercapnia (Paco(2) > 60 mm Hg).
Resumo:
Background. Considering the renal effects of fluid resuscitation in hemorrhaged patients, the choice of fluid has been a source of controversy. In a model of hemorrhagic shock, we studied the early hemodynamic and renal effects of fluid resuscitation with lactated Ringer's (LR), 6% hydroxyethyl starch (HES), and 7.5% hypertonic saline (HS) with or without 6% dextran-70 (HSD).Materials and methods. Forty-eight dogs were anesthetized and submitted to splenectomy. An estimated 40% blood volume was removed to maintain mean arterial pressure (MAP) at 40 mm Hg for 30 min. The dogs were divided into four groups: LR, in a 3:1 ratio to removed blood volume; HS, 6 mL kg(-1); HSD, 6 mL kg(-1); and HES in a 1:1 ratio to removed blood volume. Hemodynamics and renal function were studied during shock and 5, 60, and 120 min after fluid replacement.Results. Shock treatment increased MAP similarly in all groups. At 5 min, cardiac filling pressures and cardiac performance indexes were higher for LR and HES but, after 120 min, there were no differences among groups. Renal blood flow and glomerular filtration rate (GFR) were higher in LR at 60 min but GFR returned to baseline values in all groups at 120 min. Diuresis was higher for LR at 5 min and for LR and HES at 60 min. There were no differences among groups in renal variables 120 min after treatment.Conclusions. Despite the immediate differences in hemodynamic responses, the low-volume resuscitation fluids, HS and HSD, are equally effective to LR and HES in restoring renal performance 120 min after hemorrhagic shock treatment. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
O objetivo deste estudo foi verificar a influência das diferentes dimensões corporais de meninos de 11 a 13 anos de idade, nas respostas cardiorrespiratórias, ao longo dos estágios de um teste incremental de esforço máximo em cicloergômetro. Vinte meninos realizaram um teste incremental máximo em cicloergômetro com carga inicial de 30 W e incrementos subsequentes de 30 W a cada três minutos. As variáveis respiratórias foram medidas respiração-a-respiracão através de um analisador metabólico de gases. A frequência cardíaca foi constantemente monitorada durante o teste. Os grupos foram divididos a posteriori em função da carga máxima atingida no teste incremental (90 ou 120 W) e em função da massa corporal (maior ou menor que 45 kg). As seguintes variáveis foram mensuradas continuamente: frequência respiratória, volume corrente, ventilação, consumo de oxigênio absoluto e relativo, produção absoluta de gás carbônico, frequência cardíaca e equivalente ventilatório de oxigênio. Foi concluído que as variáveis antropométricas, especialmente estatura e massa corporal, mostram-se estreitamente relacionadas às respostas cardiorrespiratórias, apresentando-se como fatores determinantes e limitantes do desempenho, devendo ambas ser consideradas para a prescrição e prática de exercícios físicos desta população pediátrica.
Resumo:
O presente trabalho teve como objetivo avaliar a eficiência do herbicida sulfosate, aplicado isoladamente e em misturas com diferentes adjuvantes, comparado com o herbicida glifosate, ambos aplicados com baixo volume de calda, no controle da planta daninha arroz vermelho (Oryza sativa L.) sob aplicação em condições de préplantio da cultura do arroz. O experimento foi conduzido em campo, sendo a área experimental instalada na cultura de arroz irrigado, variedade IAC-101. A área de pousio recebeu uma lâmina de água de 5 a 10cm de pro fundidade por dois dias, e após a retirada, o arroz vermelho começou a germinar. Quando o mesmo atingiu cerca de 20-25cm de altura, procedeu-se a aplicação de herbicidas de manejo (pré-plantio) . Após 16 dias da aplicação foi efetuado o plantio da cultura com densidade de 60-80 sementes/metro linear e profundidade de 3cm, sendo o espaçamento utilizado de 21,8cm entre linhas. Foram testados tratamentos com os seguintes produtos: sulfosate a 1,20; 1,44 e 1,68Kg i.a./ha e glifosate a 1,20; 1,44 e 1,68Kg i.a./ha, ambos os produtos aplicados isolados e em misturas com os seguintes adjuvantes: Poliglicol, Organosilicone e Amina Graxa, além de uma testemunha não capinada. Para a avaliação do efeito dos tratamentos empregados foram realizadas as seguintes avaliações: fitotoxicidade aperente, porcentagem de controle do arroz vermelho; altura do arroz vermelho (em cm); estande da cultura (no de per filhos/metro linear) e altura da cultura (em cm). Através dos resultados obtidos pode-se concluir que os herbicidas sulfosate, glifosate nas formulações comerciais Rodeo e Roundup, nas doses de 1,20; 1,44 e 1,68Kg i.a./ha, aplicados isolados (exceto o Rodeo) e conjuntamente com os adjuvantes poliglicol (Mojante), organosilicone (Silwet) e amina graxa (Frigate) (exceto Roundup, que foi utilizado apenas com o adjuvante amina graxa e sozinho), propiciaram excelente nível de controle do arroz vermelho, quando aplicados em pós-emergência e área total, e pré-plantio da cultura de arroz, implantada no sistema de plantio direto. Também foi verificado que não ocorreu diferença quanto à eficiência entre sulfosate e glifosate no controle do arroz vermelho, ambos controlando de forma eficiente a planta daninha.
Resumo:
Droplets formed at the tip of a tube under the same conditions possess extreme uniformity of form, volume and weight. These properties of liquid drop formation have been known for a long time and consequently many applications for the drop have been found in instrumentation and chemical analysis methods. In the present paper, we report on the analytical use of a dynamic LED-based flow-through optical absorption detector with optical path length controlled by continuous dropping of a solution. This arrangement consists of a flow cell built within a high-intensity red LED (lambda (max)=630 nm). The feasibility of the detector is demonstrated by colorimetric determination of methylene blue, and ammonium by Berthelot's reaction, in a flow-injection system. For ammonium, the reaction forms a blue dye (indophenol) with a maximum absorption at 630-650 nm. The detection limit, considered as 3 times the signal of the blank, is better than 125 mu g l(-1). The small flow cell represents a good combination of optical path length, low volume and fast washout. This detector can be used advantageously in automated methods and can represent a solution to problems of optical detection involving gas bubbles and precipitation of particles in turbidimetric applications.
Resumo:
This paper presents a multi-cell single-phase high power factor boost rectifier in interleave connection, operating in critical conduction mode, employing a soft-switching technique, and controlled by Field Programmable Gate Array (FPGA). The soft-switching technique is based on zero-current-switching (ZCS) cells, providing ZC (zero-current) turn-on and ZCZV (zero-current-zero-voltage) turn-off for the active switches, and ZV (zero-vohage) turn-on and ZC (zero-current) turn-off for the boost diodes. The disadvantages related to reverse recovery effects of boost diodes operated in continuous conduction mode (additional losses, and electromagnetic interference (EMI) problems) are minimized, due to the operation in critical conduction mode. In addition, due to the interleaving technique, the rectifier's features include the reduction in the input current ripple, the reduction in the output voltage ripple, the use of low stress devices, low volume for the EMI input filter, high input power factor (PF), and low total harmonic distortion (THD) in the input current, in compliance with the IEC61000-3-2 standards. The digital controller has been developed using a hardware description language (VHDL) and implemented using a XC2S200E-SpartanII-E/Xilinx FPGA device, performing a true critical conduction operation mode for all interleaved cells, and a closed-loop to provide the output voltage regulation, like as a preregulator rectifier. Experimental results are presented for a implemented prototype with two and with four interleaved cells, 400V nominal output voltage and 220V(rms) nominal input voltage, in order to verify the feasibility and performance of the proposed digital control through the use of a FPGA device.
Resumo:
This paper evaluates the efficiency of geotextile filters for sludge from a compact water treatment plant (WTP). The key aspects required in the methodology of selection and designing geotextile filters for sludge from dewatering was investigated based on laboratory tests results. The analyses were supported by the measured filtrated volume of water and turbidity resulting from variable head permeability tests carried out in two geotextiles and using the conventional granular filter (sand and gravel). The results of the present study showed that more than 75% of the dewatering sludge can be filtrated with low turbidity, which permits that this water can return to the treatment plan in order to be reuse in another cycle. The reduced volume of sludge retained by the geotextile that is transferred to the drying pound increases its efficiency by reducing the drying time. The low volume of the dry waste can be removed and the geotextile can be easily cleaned or replaced when needed. These procedures significantly reduce the volume of water needed in dewatering and also avoids waste discharges in the environment.
Resumo:
This paper is based on the analysis and implementation of a new drive system applied to refrigeration systems, complying with the restrictions imposed by the IEC standards (Harmonic/Flicker/EMI-Electromagnetic Interference restrictions), in order to obtain high efficiency, high power factor, reduced harmonic distortion in the input current and reduced electromagnetic interference, with excellent performance in temperature control of a refrigeration prototype system (automatic control, precision and high dynamic response). The proposal is replace the single-phase motor by a three-phase motor, in the conventional refrigeration system. In this way, a proper control technique can be applied, using a closed-loop (feedback control), that will allow an accurate adjustment of the desirable temperature. The proposed refrigeration prototype uses a 0.5Hp three-phase motor and an open (Belt-Drive) Bitzer IY type compressor. The input rectifier stage's features include the reduction in the input current ripple, the reduction in the output voltage ripple, the use of low stress devices, low volume for the EMI input filter, high input power factor (PF), and low total harmonic distortion (THD) in the input current, in compliance with the IEC61000-3-2 standards. The digital controller for the output three-phase inverter stage has been developed using a conventional voltage-frequency control (scalar V/f control), and a simplified stator oriented Vector control, in order to verify the feasibility and performance of the proposed digital controls for continuous temperature control applied at the refrigerator prototype. ©2008 IEEE.