259 resultados para JNI


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Uncertainty persists concerning the effect of improved long-term glycemic control on macrovascular disease in diabetes mellitus (DM).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Intravascular ultrasound of drug-eluting stent (DES) thrombosis (ST) reveals a high incidence of incomplete stent apposition (ISA) and vessel remodeling. Autopsy specimens of DES ST show delayed healing and hypersensitivity reactions. The present study sought to correlate histopathology of thrombus aspirates with intravascular ultrasound findings in patients with very late DES ST. METHODS AND RESULTS: The study population consisted of 54 patients (28 patients with very late DES ST and 26 controls). Of 28 patients with very late DES ST, 10 patients (1020+/-283 days after implantation) with 11 ST segments (5 sirolimus-eluting stents, 5 paclitaxel-eluting stents, 1 zotarolimus-eluting stent) underwent both thrombus aspiration and intravascular ultrasound investigation. ISA was present in 73% of cases with an ISA cross-sectional area of 6.2+/-2.4 mm(2) and evidence of vessel remodeling (index, 1.6+/-0.3). Histopathological analysis showed pieces of fresh thrombus with inflammatory cell infiltrates (DES, 263+/-149 white blood cells per high-power field) and eosinophils (DES, 20+/-24 eosinophils per high-power field; sirolimus-eluting stents, 34+/-28; paclitaxel-eluting stents, 6+/-6; P for sirolimus-eluting stents versus paclitaxel-eluting stents=0.09). The mean number of eosinophils per high-power field was higher in specimens from very late DES ST (20+/-24) than in those from spontaneous acute myocardial infarction (7+/-10), early bare-metal stent ST (1+/-1), early DES ST (1+/-2), and late bare-metal stent ST (2+/-3; P from ANOVA=0.038). Eosinophil count correlated with ISA cross-sectional area, with an average increase of 5.4 eosinophils per high-power field per 1-mm(2) increase in ISA cross-sectional area. CONCLUSIONS: Very late DES thrombosis is associated with histopathological signs of inflammation and intravascular ultrasound evidence of vessel remodeling. Compared with other causes of myocardial infarction, eosinophilic infiltrates are more common in thrombi harvested from very late DES thrombosis, particularly in sirolimus-eluting stents, and correlate with the extent of stent malapposition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIMS: Lesion length remains a predictor of target lesion revascularisation and results of long lesion stenting remain poor. Sirolimus-eluting stents have been shown to perform better than paclitaxel eluting stents in long lesions. In this substudy of the LEADERS trial, we compared the performance of biolimus biodegradable polymer (BES) and sirolimus permanent polymer stents (SES) in long lesions. METHODS AND RESULTS: A total of 1,707 'all-comer' patients were randomly allocated to treatment with BES and SES. A stratified analysis of angiographic and clinical outcomes at nine months and one year, respectively was performed for vessels with lesion length <20 mm versus >20 mm (as measured by quantitative angiography).Of 1,707 patients, 592 BES patients with 831 lesions and 619 SES patients with 876 lesions had only short lesions treated. One hundred and fifty-three BES patients with 166 lesions and 151 SES patients with 162 lesions had long lesions. There were no significant differences in baseline clinical characteristics, except for higher number of patients with long lesions presenting with acute myocardial infarction in both stent groups. Long lesions tended to have lower MLD and greater percent diameter stenosis at baseline than short lesions. Late loss was greater for long lesions than short lesions. There was no statistically significant difference in late loss between BES and SES stents (0.32+/-0.69 vs 0.24+/-0.57, p=0.59). Binary in-segment restenosis was present in 23.2% versus 13.1% of long lesions treated with BES and SES, respectively (p=0.042). In patients with long lesions, the overall MACE rate was similar for BES and SES (17% vs 14.6%; p=0.62). There was a trend towards higher overall TLR rate with BES (12.4 % vs 6.0%; HR=2.06; p=0.07) and clinically driven TLR (10.5% vs 5.3%: HR 1.94; p=0.13). Rates of definite stent thrombosis were 3.3% in the long lesion group and 1.3-1.7 % in the short lesion group. CONCLUSIONS: BES and SES appear similar with respect to MACE in long lesions in this "all-comer" patient population. However, long lesions tended to have a higher rate of binary in-segment restenosis and TLR following BES than SES treatment.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the association of adequate allocation concealment and patient blinding with estimates of treatment benefits in osteoarthritis trials. METHODS: We performed a meta-epidemiologic study of 16 meta-analyses with 175 trials that compared therapeutic interventions with placebo or nonintervention control in patients with hip or knee osteoarthritis. We calculated effect sizes from the differences in means of pain intensity between groups at the end of followup divided by the pooled SD and compared effect sizes between trials with and trials without adequate methodology. RESULTS: Effect sizes tended to be less beneficial in 46 trials with adequate allocation concealment compared with 112 trials with inadequate or unclear concealment of allocation (difference -0.15; 95% confidence interval [95% CI] -0.31, 0.02). Selection bias associated with inadequate or unclear concealment of allocation was most pronounced in meta-analyses with large estimated treatment benefits (P for interaction < 0.001), meta-analyses with high between-trial heterogeneity (P = 0.009), and meta-analyses of complementary medicine (P = 0.019). Effect sizes tended to be less beneficial in 64 trials with adequate blinding of patients compared with 58 trials without (difference -0.15; 95% CI -0.39, 0.09), but differences were less consistent and disappeared after accounting for allocation concealment. Detection bias associated with a lack of adequate patient blinding was most pronounced for nonpharmacologic interventions (P for interaction < 0.001). CONCLUSION: Results of osteoarthritis trials may be affected by selection and detection bias. Adequate concealment of allocation and attempts to blind patients will minimize these biases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Bleeding is a frequent complication during surgery. The intraoperative administration of blood products, including packed red blood cells, platelets and fresh frozen plasma (FFP), is often live saving. Complications of blood transfusions contribute considerably to perioperative costs and blood product resources are limited. Consequently, strategies to optimize the decision to transfuse are needed. Bleeding during surgery is a dynamic process and may result in major blood loss and coagulopathy due to dilution and consumption. The indication for transfusion should be based on reliable coagulation studies. While hemoglobin levels and platelet counts are available within 15 minutes, standard coagulation studies require one hour. Therefore, the decision to administer FFP has to be made in the absence of any data. Point of care testing of prothrombin time ensures that one major parameter of coagulation is available in the operation theatre within minutes. It is fast, easy to perform, inexpensive and may enable physicians to rationally determine the need for FFP. METHODS/DESIGN: The objective of the POC-OP trial is to determine the effectiveness of point of care prothrombin time testing to reduce the administration of FFP. It is a patient and assessor blind, single center randomized controlled parallel group trial in 220 patients aged between 18 and 90 years undergoing major surgery (any type, except cardiac surgery and liver transplantation) with an estimated blood loss during surgery exceeding 20% of the calculated total blood volume or a requirement of FFP according to the judgment of the physicians in charge. Patients are randomized to usual care plus point of care prothrombin time testing or usual care alone without point of care testing. The primary outcome is the relative risk to receive any FFP perioperatively. The inclusion of 110 patients per group will yield more than 80% power to detect a clinically relevant relative risk of 0.60 to receive FFP of the experimental as compared with the control group. DISCUSSION: Point of care prothrombin time testing in the operation theatre may reduce the administration of FFP considerably, which in turn may decrease costs and complications usually associated with the administration of blood products. TRIAL REGISTRATION: NCT00656396.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Osteoarthritis is a chronic joint disease that involves degeneration of articular cartilage. Pre-clinical data suggest that doxycycline might act as a disease-modifying agent for the treatment of osteoarthritis, with the potential to slow cartilage degeneration. OBJECTIVES: To examine the effects of doxycycline compared with placebo or no intervention on pain and function in patients with osteoarthritis of the hip or knee. SEARCH STRATEGY: We searched CENTRAL ( The Cochrane Library 2008, issue 3), MEDLINE, EMBASE and CINAHL up to 28 July 2008, checked conference proceedings, reference lists, and contacted authors. SELECTION CRITERIA: We included studies if they were randomised or quasi-randomised controlled trials that compared doxycycline at any dosage and any formulation with placebo or no intervention in patients with osteoarthritis of the knee or hip. DATA COLLECTION AND ANALYSIS: We extracted data in duplicate. We contacted investigators to obtain missing outcome information. We calculated differences in means at follow-up between experimental and control groups for continuous outcomes and risk ratios for binary outcomes. MAIN RESULTS: We found one randomised controlled trial that compared doxycycline with placebo in 431 obese women. After 30 months of treatment, clinical outcomes were similar between the two treatment groups, with a mean difference of -0.20 cm (95% confidence interval (CI) -0.77 to 0.37 cm) on a visual analogue scale from 0 to 10 cm for pain and -1.10 units (95% CI -3.86 to 1.66) for function on the WOMAC disability subscale, which ranges from 17 to 85. These differences correspond to clinically irrelevant effect sizes of -0.08 and -0.09 standard deviation units for pain and function, respectively. The difference in changes in minimum joint space narrowing was in favour of doxycycline (-0.15 mm, 95% CI -0.28 to -0.02 mm), which corresponds to a small effect size of -0.23 standard deviation units. More patients withdrew from the doxycycline group compared with placebo due to adverse events (risk ratio 1.69, 95% CI 1.03 to 2.75). AUTHORS' CONCLUSIONS: The symptomatic benefit of doxycycline is minimal to non-existent. The small benefit in terms of joint space narrowing is of questionable clinical relevance and outweighed by safety problems. Doxycycline should not be recommended for the treatment of osteoarthritis of the knee or hip.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Osteoarthritis is the most common form of joint disease and the leading cause of pain and disability in the elderly. S-Adenosylmethionine may be a viable treatment option but the evidence about its effectiveness and safety is equivocal. OBJECTIVES: We set out to compare S-Adenosylmethionine (SAMe) with placebo or no specific intervention in terms of effects on pain and function and safety outcomes in patients with knee or hip osteoarthritis. SEARCH STRATEGY: We searched CENTRAL, MEDLINE, EMBASE, CINAHL and PEDro up to 5 August 2008, checked conference proceedings and reference lists, and contacted authors. SELECTION CRITERIA: Randomised or quasi-randomised controlled trials that compared SAMe at any dosage and in any formulation with placebo or no intervention in patients with osteoarthritis of the knee or hip. DATA COLLECTION AND ANALYSIS: Two independent authors extracted data using standardised forms. We contacted investigators to obtain missing outcome information. We calculated standardised mean differences (SMDs) for pain and function, and relative risks for safety outcomes. We combined trials using inverse-variance random-effects meta-analysis. MAIN RESULTS: Four trials including 656 patients were included in the systematic review, all compared SAMe with placebo. The methodological quality and the quality of reporting were poor. For pain, the analysis indicated a small SMD of -0.17 (95% CI -0.34 to 0.01), corresponding to a difference in pain scores between SAMe and placebo of 0.4 cm on a 10 cm VAS, with no between trial heterogeneity (I(2) = 0). For function, the analysis suggested a SMD of 0.02 (95% CI -0.68 to 0.71) with a moderate degree of between-trial heterogeneity (I2 = 54%). The meta-analyses of the number of patients experiencing any adverse event, and withdrawals or drop-outs due to adverse events, resulted in relative risks of 1.27 (95% CI 0.94 to 1.71) and 0.94 (95% CI 0.48 to 1.86), respectively, but confidence intervals were wide and tests for overall effect were not significant. No trial provided information concerning the occurrence of serious adverse events. AUTHORS' CONCLUSIONS: The current systematic review is inconclusive, hampered by the inclusion of mainly small trials of questionable quality. The effects of SAMe on both pain and function may be potentially clinically relevant and, although effects are expected to be small, deserve further clinical evaluation in adequately sized randomised, parallel-group trials in patients with knee or hip osteoarthritis. Meanwhile, routine use of SAMe should not be advised.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Osteoarthritis is the most common form of joint disease and the leading cause of pain and physical disability in the elderly. Opioids may be a viable treatment option if patients suffer from severe pain or if other analgesics are contraindicated. However, the evidence about their effectiveness and safety is contradictory. OBJECTIVES: To determine the effects on pain and function and the safety of oral or transdermal opioids as compared with placebo or no intervention in patients with osteoarthritis of the hip or knee. SEARCH STRATEGY: We searched CENTRAL, MEDLINE, EMBASE, and CINAHL (up to 28 July 2008), checked conference proceedings, reference lists, and contacted authors. SELECTION CRITERIA: Studies were included if they were randomised or quasi-randomised controlled trials that compared oral or transdermal opioids with placebo or no treatment in patients with osteoarthritis of the knee or hip. Studies of tramadol were excluded. No language restrictions were applied. DATA COLLECTION AND ANALYSIS: We extracted data in duplicate. Standardised mean differences (SMDs) and 95% confidence intervals (CI) were calculated for pain and function, and risk ratios for safety outcomes. Trials were combined using inverse-variance random-effects meta-analysis. MAIN RESULTS: Ten trials with 2268 participants were included. Oral codeine was studied in three trials, transdermal fentanyl and oral morphine in one trial each, oral oxycodone in four, and oral oxymorphone in two trials. Overall, opioids were more effective than control interventions in terms of pain relief (SMD -0.36, 95% CI -0.47 to -0.26) and improvement of function (SMD -0.33, 95% CI -0.45 to -0.21). We did not find substantial differences in effects according to type of opioid, analgesic potency (strong or weak), daily dose, duration of treatment or follow up, methodological quality of trials, and type of funding. Adverse events were more frequent in patients receiving opioids compared to control. The pooled risk ratio was 1.55 (95% CI 1.41 to 1.70) for any adverse event (4 trials), 4.05 (95% CI 3.06 to 5.38) for dropouts due to adverse events (10 trials), and 3.35 (95% CI 0.83 to 13.56) for serious adverse events (2 trials). Withdrawal symptoms were more severe after fentanyl treatment compared to placebo (SMD 0.60, 95% CI 0.42 to 0.79; 1 trial). AUTHORS' CONCLUSIONS: The small to moderate beneficial effects of non-tramadol opioids are outweighed by large increases in the risk of adverse events. Non-tramadol opioids should therefore not be routinely used, even if osteoarthritic pain is severe.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Osteoarthritis is the most common form of joint disease and the leading cause of pain and physical disability in the elderly. Transcutaneous electrical nerve stimulation (TENS), interferential current stimulation and pulsed electrostimulation are used widely to control both acute and chronic pain arising from several conditions, but some policy makers regard efficacy evidence as insufficient. OBJECTIVES: To compare transcutaneous electrostimulation with sham or no specific intervention in terms of effects on pain and withdrawals due to adverse events in patients with knee osteoarthritis. SEARCH STRATEGY: We updated the search in CENTRAL, MEDLINE, EMBASE, CINAHL and PEDro up to 5 August 2008, checked conference proceedings and reference lists, and contacted authors. SELECTION CRITERIA: Randomised or quasi-randomised controlled trials that compared transcutaneously applied electrostimulation with a sham intervention or no intervention in patients with osteoarthritis of the knee. DATA COLLECTION AND ANALYSIS: We extracted data using standardised forms and contacted investigators to obtain missing outcome information. Main outcomes were pain and withdrawals or dropouts due to adverse events. We calculated standardised mean differences (SMDs) for pain and relative risks for safety outcomes and used inverse-variance random-effects meta-analysis. The analysis of pain was based on predicted estimates from meta-regression using the standard error as explanatory variable. MAIN RESULTS: In this update we identified 14 additional trials resulting in the inclusion of 18 small trials in 813 patients. Eleven trials used TENS, four interferential current stimulation, one both TENS and interferential current stimulation, and two pulsed electrostimulation. The methodological quality and the quality of reporting was poor and a high degree of heterogeneity among the trials (I(2) = 80%) was revealed. The funnel plot for pain was asymmetrical (P < 0.001). The predicted SMD of pain intensity in trials as large as the largest trial was -0.07 (95% CI -0.46 to 0.32), corresponding to a difference in pain scores between electrostimulation and control of 0.2 cm on a 10 cm visual analogue scale. There was little evidence that SMDs differed on the type of electrostimulation (P = 0.94). The relative risk of being withdrawn or dropping out due to adverse events was 0.97 (95% CI 0.2 to 6.0). AUTHORS' CONCLUSIONS: In this update, we could not confirm that transcutaneous electrostimulation is effective for pain relief. The current systematic review is inconclusive, hampered by the inclusion of only small trials of questionable quality. Appropriately designed trials of adequate power are warranted.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To examine whether excluding patients from the analysis of randomised trials are associated with biased estimates of treatment effects and higher heterogeneity between trials. DESIGN: Meta-epidemiological study based on a collection of meta-analyses of randomised trials. DATA SOURCES: 14 meta-analyses including 167 trials that compared therapeutic interventions with placebo or non-intervention control in patients with osteoarthritis of the hip or knee and used patient reported pain as an outcome. METHODS: Effect sizes were calculated from differences in means of pain intensity between groups at the end of follow-up, divided by the pooled standard deviation. Trials were combined by using random effects meta-analysis. Estimates of treatment effects were compared between trials with and trials without exclusions from the analysis, and the impact of restricting meta-analyses to trials without exclusions was assessed. RESULTS: 39 trials (23%) had included all patients in the analysis. In 128 trials (77%) some patients were excluded from the analysis. Effect sizes from trials with exclusions tended to be more beneficial than those from trials without exclusions (difference -0.13, 95% confidence interval -0.29 to 0.04). However, estimates of bias between individual meta-analyses varied considerably (tau(2)=0.07). Tests of interaction between exclusions from the analysis and estimates of treatment effects were positive in five meta-analyses. Stratified analyses indicated that differences in effect sizes between trials with and trials without exclusions were more pronounced in meta-analyses with high between trial heterogeneity, in meta-analyses with large estimated treatment benefits, and in meta-analyses of complementary medicine. Restriction of meta-analyses to trials without exclusions resulted in smaller estimated treatment benefits, larger P values, and considerable decreases in between trial heterogeneity. CONCLUSION: Excluding patients from the analysis in randomised trials often results in biased estimates of treatment effects, but the extent and direction of bias is unpredictable. Results from intention to treat analyses should always be described in reports of randomised trials. In systematic reviews, the influence of exclusions from the analysis on estimated treatment effects should routinely be assessed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To study the inter-observer variation related to extraction of continuous and numerical rating scale data from trial reports for use in meta-analyses. DESIGN: Observer agreement study. DATA SOURCES: A random sample of 10 Cochrane reviews that presented a result as a standardised mean difference (SMD), the protocols for the reviews and the trial reports (n=45) were retrieved. DATA EXTRACTION: Five experienced methodologists and five PhD students independently extracted data from the trial reports for calculation of the first SMD result in each review. The observers did not have access to the reviews but to the protocols, where the relevant outcome was highlighted. The agreement was analysed at both trial and meta-analysis level, pairing the observers in all possible ways (45 pairs, yielding 2025 pairs of trials and 450 pairs of meta-analyses). Agreement was defined as SMDs that differed less than 0.1 in their point estimates or confidence intervals. RESULTS: The agreement was 53% at trial level and 31% at meta-analysis level. Including all pairs, the median disagreement was SMD=0.22 (interquartile range 0.07-0.61). The experts agreed somewhat more than the PhD students at trial level (61% v 46%), but not at meta-analysis level. Important reasons for disagreement were differences in selection of time points, scales, control groups, and type of calculations; whether to include a trial in the meta-analysis; and data extraction errors made by the observers. In 14 out of the 100 SMDs calculated at the meta-analysis level, individual observers reached different conclusions than the originally published review. CONCLUSIONS: Disagreements were common and often larger than the effect of commonly used treatments. Meta-analyses using SMDs are prone to observer variation and should be interpreted with caution. The reliability of meta-analyses might be improved by having more detailed review protocols, more than one observer, and statistical expertise.