921 resultados para Invasive


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective This paper reviews the development and clinical validation of photodynamic diagnosis (PDD) of bladder cancer. Methods The authors reviewed the literature on the development of PDD, in particular the evidence for the clinical efficacy of hexaminolevulinate PDD in the diagnosis of bladder cancer. Results After initial work on ultraviolet cystoscopy following oral tetracycline, the focus of PDD research shifted to the use of synthetic porphyrins. First, the prodrug delta-aminolevulinic acid (ALA) was shown to cause a transient but significant accumulation of protoporphyrin IX (PpIX) in malignant or premalignant bladder tissue. Excitation by blue light leads to PpIX fluorescence (red), which distinguishes tumour from normal tissue (blue). Hexaminolevulinate (HAL, Hexvix), an ester of ALA, was then developed and has greater bioavailability and stability than the parent compound. It has been approved for clinical use in the diagnosis of bladder cancer. Clinical studies have shown that HAL PDD detects tumours, including carcinoma in situ (CIS), that are missed by conventional white-light cystoscopy. Conclusions HAL PDD is a valuable aid to the detection of bladder tumours, including CIS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is an ever-growing trend towards less-invasive procedures in all fields of medicine. We designed an animal study to prove the concept that trans-apical aortic valve replacement from an incision within the umbilicus through a single channel for instruments is feasible, which would be a major leap towards no-scar cardiac surgery. In three adult pigs, after creating a single 3-cm incision at a place where the human umbilicus would be, we introduced a 30F sheath through a tunnel created by an endoscopic vein-harvesting device up to the cardiac apex, through it and up to the left ventricle simulating the approach for trans-apical aortic valve replacement. We used a standard Amplatz nitinol occluder to seal the defect in ventricle wall later. The animals were followed up for 1h. Blood loss was minimal, and no tamponade occurred in any of the animals. In addition, we performed a test with water column static pressure to evaluate the impact of preclotting on the sealing properties of the occluders: 1 min flow-through was 2860+/-176 ml for the standard occluders and 348+/-56 ml for preclotted occluders (p<0.001).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Echocardiography is the preferred initial test to assess cardiac morphology and ventricular function. Cardiac MRI enables an optimal visualisation of heart muscle without contrast injection, and precise measurement of the ventricular volumes and systolic function. It is therefore an ideal test for patients with poor echocardiographic windows or for the specific evaluation of right heart chambers. Heart CT also remarkably images heart muscle and precisely measures ventricular systolic function after intravenous injection of iodinated contrast. Coronary CT may also, in selected cases, avoid the need for diagnostic coronary angiography. Although very accurate, these imaging modalities are expensive and may be contra-indicated for a particular patient. Their use in clinical practice has to follow the accepted guidelines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To document and compare the prevalence of asynchrony events during invasive-assisted mechanical ventilation in pressure support mode and in neurally adjusted ventilatory assist in children. DESIGN: Prospective, randomized, and crossover study. SETTING: Pediatric and Neonatal Intensive Care Unit, University Hospital of Geneva, Switzerland. PATIENTS: Intubated and mechanically ventilated children, between 4 weeks and 5 years old. INTERVENTIONS: Two consecutive ventilation periods (pressure support and neurally adjusted ventilatory assist) were applied in random order. During pressure support, three levels of expiratory trigger setting were compared: expiratory trigger setting as set by the clinician in charge (PSinit), followed by a 10% (in absolute values) increase and decrease of the clinician's expiratory trigger setting. The pressure support session with the least number of asynchrony events was defined as PSbest. Therefore, three periods were compared: PSinit, PSbest, and neurally adjusted ventilatory assist. Asynchrony events, trigger delay, and inspiratory time in excess were quantified for each of them. MEASUREMENTS AND MAIN RESULTS: Data from 19 children were analyzed. Main asynchrony events during PSinit were autotriggering (3.6 events/min [0.7-8.2]), ineffective efforts (1.2/min [0.6-5]), and premature cycling (3.5/min [1.3-4.9]). Their number was significantly reduced with PSbest: autotriggering 1.6/min (0.2-4.9), ineffective efforts 0.7/min (0-2.6), and premature cycling 2/min (0.1-3.1), p < 0.005 for each comparison. The median asynchrony index (total number of asynchronies/triggered and not triggered breaths ×100) was significantly different between PSinit and PSbest: 37.3% [19-47%] and 29% [24-43%], respectively, p < 0.005). With neurally adjusted ventilatory assist, all types of asynchrony events except double-triggering and inspiratory time in excess were significantly reduced resulting in an asynchrony index of 3.8% (2.4-15%) (p < 0.005 compared to PSbest). CONCLUSIONS: Asynchrony events are frequent during pressure support in children despite adjusting the cycling off criteria. Neurally adjusted ventilatory assist allowed for an almost ten-fold reduction in asynchrony events. Further studies should determine the clinical impact of these findings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectifs : Evaluer une méthode simple et rapide de mesure du volume atrial gauche. Matériels et méthodes : Cinquante patients ont été examinés avec un CT gaté pour mesure du score calcique. Trois méthodes ont été utilisées pour calculer le volume atrial gauche : 1) une méthode orthogonale avec mesure des surfaces/diamètres dans les plans axiaux/coronaux/sagittaux, 2) une méthode biplan inspirée de l'échocardiographie et 3) une méthode volumétrique. Les mesures ont été faites par le même observateur un mois plus tard et ont été répétées par trois autres observateurs. L'axe cardiaque a aussi été mesuré. La méthode Bland-Altmann et les corrélations de Spearman ont été utilisées. Résultats : La méthode volumétrique montre les variations intra/interobservateur les plus basses avec une variabilité de 6,1/7,4 ml, respectivement. Pour les mesures avec la méthode orthogonale (surfaces/diamètres), les variations intra/interobservateur sont 12,3/13,5 ml et 14,6/11,6 ml, respectivement. Pour la méthode biplan, les variations intra/interobservateur sont plus hautes : 23,9/19,8 ml. Comparée à la méthode de référence volumétrique, la méthode orthogonale avec les surfaces est mieux corrélée (R=0,959, p<0,001) que les autres méthodes. Il y a une faible influence de l'axe du coeur sur la méthode orthogonale avec les surfaces. Conclusion : La méthode volumétrique est le gold standard en terme de variabilité. Cependant elle est longue à metttre en oeuvre. La méthode orthogonale avec les surfaces est une alternative simple, sauf chez les patients obèses avec un coeur horizontalisé.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Invasive fungal diseases are important causes of morbidity and mortality. Clarity and uniformity in defining these infections are important factors in improving the quality of clinical studies. A standard set of definitions strengthens the consistency and reproducibility of such studies. METHODS: After the introduction of the original European Organization for Research and Treatment of Cancer/Invasive Fungal Infections Cooperative Group and the National Institute of Allergy and Infectious Diseases Mycoses Study Group (EORTC/MSG) Consensus Group definitions, advances in diagnostic technology and the recognition of areas in need of improvement led to a revision of this document. The revision process started with a meeting of participants in 2003, to decide on the process and to draft the proposal. This was followed by several rounds of consultation until a final draft was approved in 2005. This was made available for 6 months to allow public comment, and then the manuscript was prepared and approved. RESULTS: The revised definitions retain the original classifications of "proven," "probable," and "possible" invasive fungal disease, but the definition of "probable" has been expanded, whereas the scope of the category "possible" has been diminished. The category of proven invasive fungal disease can apply to any patient, regardless of whether the patient is immunocompromised, whereas the probable and possible categories are proposed for immunocompromised patients only. CONCLUSIONS: These revised definitions of invasive fungal disease are intended to advance clinical and epidemiological research and may serve as a useful model for defining other infections in high-risk patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

From November 1992 to December 1997, 25 patients (inoperable or refusing cystectomy) were included in a prospective study to assess the feasibility, tolerance, and curative potential of accelerated radiotherapy (RT) and concomitant cisplatin. Median age was 74 years (range 49-86). Stage distribution was as follows: 1 T1, 10 T2, 8 T3, and 6 T4. Two patients had clinically positive pelvic nodes. The goal was to deliver a total dose of 40 Gy to the whole pelvis and bladder in 4 weeks using a concomitant boost of 20 Gy to the tumor or to the whole bladder during the third and fourth weeks (total dose 60 Gy), with daily cisplatin (6 mg/m(2)) before RT for patients with creatinine clearance > 50 ml/min. All but one patient completed the RT protocol. Daily cisplatin was successfully delivered in 18 patients. One patient presented with grade III ototoxicity. Diarrhea was scored grade III in two and grade IV in two patients. Acute urinary toxicity was scored grade III in one patient. Posttreatment late effects included bladder grade II and grade III in two patients and one patient, respectively; large bowel grade III in one; urethral grade III in one; and femoral head radionecrosis in one. Four-year overall and disease-specific survival rates were 23% and 35%, respectively. The latter was 60% for patients with T2 tumors. The 4-year actuarial locoregional control rate for all patients was 61%. In summary, accelerated RT and concomitant cisplatin is feasible with acceptable tolerance even in relatively old patients. Although outcome was better for patients with low-stage tumors, local control and survival rates appeared similar to those of standard RT schedules for a similar patient population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The marsh frog (Pelophylax ridibundus) has been introduced in many places of Central and Western Europe due to commercial trades with Eastern Europe, and is rapidly replacing the native pool frog (P. lessonae). A large number of Pelophylax species are distributed in Eastern Europe and the strong phenotypic similarity between these species is rendering their identification hazardous. Consequently, alien populations of Pelophylax might not strictly be composed of P. ridibundus as previously suspected. In the present study, we analyzed the cytochrome b and NADH dehydrogenase subunit 3 genes of introduced and native Pelophylax from Switzerland (299 individuals), in order to properly identify the source populations of the invaders and the genetic status of the native species. Our study highlighted the occurrence of several genetic lineages of invasive frogs in western Switzerland. Unexpectedly, we also showed that several populations of the native pool frog (P. lessonae) cluster with the Italian pool frog P. bergeri from central Italy (considered by some authors as a subspecies of P. lessonae) Hence, these populations are probably also the result of introductions, meaning that the number of native P. lessonae populations is less important than expected in Switzerland. These findings have important implications concerning the conservation of the endemic pool frog populations, as the presence of multiple alien species could strongly affect their long-term subsistence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel approach to the study of hepatic glycogen kinetics and fractional gluconeogenesis in vivo is described. Ten healthy female subjects were fed an iso-caloric diet containing 55% carbohydrate energy with a 13C abundance of 1.083 atom percent for a 3-day baseline period; then, a diet of similar composition, but providing carbohydrate with a 13C abundance of 1.093 atom percent was started and continued for 5 days. Resting respiratory gas exchanges, urinary nitrogen excretion, breath 13CO2 and plasma 13C glucose were measured every morning in the fasting state. The enrichment in 13C of hepatic glycogen was calculated from these measured data. 13C glycogen enrichment increased after switching to a 13C enriched carbohydrate diet, and was identical to the 13C enrichment of dietary carbohydrates after 3 days. The time required to renew 50% of hepatic glycogen, as determined from the kinetics of 13C glycogen enrichment, was 18.9 +/- 3.6 h. Fractional gluconeogenesis, as determined from the difference between the enrichments of glucose oxidized originating from hepatic glycogen and plasma glucose 13C was 50.8 +/- 5.3%. This non-invasive method will allow the study of hepatic glycogen metabolism in insulin-resistant patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUME : L'application d'une ventilation non-invasive (VNI) à pression positive chez des patients avec une insuffisance respiratoire aiguë hypoxémique non liée à une broncho-pneumopathie chronique obstructive (BPCO), reste controversée malgré les résultats encourageants apparus dans de récentes études. Ce travail de thèse est composé d'une introduction qui comprend un historique de la VNI et une revue de ces applications principales dans l'insuffisance respiratoire aiguë avec, en particulier, une analyse des études cliniques principales concernant son utilisation dans l'exacerbation de la BPCO, dans l'asthme aigu sévère, dans les syndromes restrictifs et dans l'insuffisance respiratoire aiguë hypoxémique. La première partie aborde également les aspects pratiques de l'utilisation de la VNI, avec une description de l'équipement et des techniques utilisées. Ce travail de thèse a ensuite pour but d'analyser dans une étude personnelle l'application d'une VNI à pression positive chez des patients avec une insuffisance respiratoire aiguë hypoxémique non liée à une BPCO. Il s'agit d'une étude prospective et observationnelle, dans laquelle nous avons voulu analyser l'efficacité de la VNI chez un groupe de patients sélectionnés et coopérants, stables du point de vue hémodynamique, présentant un syndrome de détresse respiratoire aiguë (SDRA) primaire (atteinte pulmonaire directe). Les échanges gazeux, le taux d'intubation, la mortalité et la durée de séjour dans l'unité de soins intensifs ont été enregistrés. Dans notre travail, la VNI a été appliquée de manière prospective à 12 patients, stables du point de vue hémodynamique, présentant les critères diagnostiques pour un SDRA primaire (SDRAP) et une indication pour une ventilation mécanique classique. Leur évolution a été comparée avec celle d'un groupe contrôle de 12 patients avec SDRAP. et précédemment traités dans la même unité de soins intensifs, ayant des caractéristiques similaires à l'admission : âge, score SAPS II, rapport Pa02/Fi02 et valeurs de pH . Un échec de la VNI fut observé chez 4 patients (33%), tous bactériémiques et nécessitant une intubation endotrachéale. Un facteur prédictif négatif. Les patients traités avec succès ont présenté un temps cumulatif de ventilation (p=0.001) et une durée de séjour aux soins intensifs (p=0.004) inférieure à ceux du groupe contrôle. Pendant la première période d'observation de la ventilation, l'oxygénation après 60 minutes s'est améliorée de manière plus importante dans le groupe VNI par rapport au groupe contrôle (PaO2/FiO2 : 146 +/- 52 mmHg vs. 109 +/- 34 mmHg ; p=0.05). Le taux de mortalité globale aux soins intensifs ne fut pas différent entre le groupe VNI et le groupe de patients intubés. Le taux de complications graves fut plus élevé chez les patients du groupe contrôle. Nos résultats suggèrent que chez des patients stables et coopérants, avec une pneumonie étendue, sans bactériémie à l'admission et remplissant les critères diagnostiques d'un SDRAp, la VNI représente une alternative valable à l'intubation endotrachéale.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Blood pressures measured casually by a doctor often differ considerably from those recorded during everyday activities away from the medical environment. In the present study, we compared office and ambulatory recorded pressures in 475 consecutive untreated patients diagnosed hypertensive by physicians. Blood pressure monitored non-invasively during the day was, on average 15/7 mmHg lower than the corresponding office pressures. The difference between office and ambulatory recorded pressure tended to be greatest in those patients with the highest office blood pressure levels, although the relationship between the two types of measurement was too weak (r = 0.50 and 0.38 for systolic and diastolic pressure, respectively) to have any predictive value in the individual patient. Office blood pressures were at least 10 mmHg higher than ambulatory pressures in 62% of patients for systolic and 42% for diastolic pressure. Blood pressure levels recorded during ambulatory monitoring were higher than in the doctor's office for 18% of patients for systolic and 22% for diastolic pressure. Among patients with systolic pressures of between 161 and 180 mmHg or diastolic pressures between 96 and 105 mmHg when facing a doctor, 27 and 37% respectively, showed markedly lower systolic (less than 140 mmHg) or diastolic (less than 90 mmHg) ambulatory recorded pressures. These data therefore indicate that ambulatory blood pressure monitoring may help to identify those truly hypertensive patients who are most likely to benefit from antihypertensive therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Invasive fungal diseases (IFDs) have become major causes of morbidity and mortality among highly immunocompromised patients. Authoritative consensus criteria to diagnose IFD have been useful in establishing eligibility criteria for antifungal trials. There is an important need for generation of consensus definitions of outcomes of IFD that will form a standard for evaluating treatment success and failure in clinical trials. Therefore, an expert international panel consisting of the Mycoses Study Group and the European Organization for Research and Treatment of Cancer was convened to propose guidelines for assessing treatment responses in clinical trials of IFDs and for defining study outcomes. Major fungal diseases that are discussed include invasive disease due to Candida species, Aspergillus species and other molds, Cryptococcus neoformans, Histoplasma capsulatum, and Coccidioides immitis. We also discuss potential pitfalls in assessing outcome, such as conflicting clinical, radiological, and/or mycological data and gaps in knowledge.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION. Patient-ventilator asynchrony is a frequent issue in non invasivemechanical ventilation (NIV) and leaks at the patient-mask interface play a major role in itspathogenesis. NIV algorithms alleviate the deleterious impact of leaks and improve patient-ventilator interaction. Neurally adusted ventilatory assist (NAVA), a neurally triggered modethat avoids interferences between leaks and the usual pneumatic trigger, could further improvepatient-ventilator interaction in NIV patients.OBJECTIVES. To evaluate the feasibility ofNAVAin patients receiving a prophylactic postextubationNIV and to compare the respective impact ofPSVandNAVAwith and withoutNIValgorithm on patient-ventilator interaction.METHODS. Prospective study conducted in 16 beds adult critical care unit (ICU) in a tertiaryuniversity hospital. Over a 2 months period, were included 17 adult medical ICU patientsextubated for less than 2 h and in whom a prophylactic post-extubation NIV was indicated.Patients were randomly mechanically ventilated for 10 min with: PSV without NIV algorithm(PSV-NIV-), PSV with NIV algorithm (PSV-NIV+),NAVAwithout NIV algorithm (NAVANIV-)and NAVA with NIV algorithm (NAVA-NIV+). Breathing pattern descriptors, diaphragmelectrical activity, leaks volume, inspiratory trigger delay (Tdinsp), inspiratory time inexcess (Tiexcess) and the five main asynchronies were quantified. Asynchrony index (AI) andasynchrony index influenced by leaks (AIleaks) were computed.RESULTS. Peak inspiratory pressure and diaphragm electrical activity were similar in thefour conditions. With both PSV and NAVA, NIV algorithm significantly reduced the level ofleak (p\0.01). Tdinsp was not affected by NIV algorithm but was shorter in NAVA than inPSV (p\0.01). Tiexcess was shorter in NAVA and PSV-NIV+ than in PSV-NIV- (p\0.05).The prevalence of double triggering was significantly lower in PSV-NIV+ than in NAVANIV+.As compared to PSV,NAVAsignificantly reduced the prevalence of premature cyclingand late cycling while NIV algorithm did not influenced premature cycling. AI was not affectedby NIV algorithm but was significantly lower in NAVA than in PSV (p\0.05). AIleaks wasquasi null with NAVA and significantly lower than in PSV (p\0.05).CONCLUSIONS. NAVA is feasible in patients receiving a post-extubation prophylacticNIV. NAVA and NIV improve patient-ventilator synchrony in different manners. NAVANIV+offers the best patient-ventilator interaction. Clinical studies are required to assess thepotential clinical benefit of NAVA in patients receiving NIV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The clinical demand for a device to monitor Blood Pressure (BP) in ambulatory scenarios with minimal use of inflation cuffs is increasing. Based on the so-called Pulse Wave Velocity (PWV) principle, this paper introduces and evaluates a novel concept of BP monitor that can be fully integrated within a chest sensor. After a preliminary calibration, the sensor provides non-occlusive beat-by-beat estimations of Mean Arterial Pressure (MAP) by measuring the Pulse Transit Time (PTT) of arterial pressure pulses travelling from the ascending aorta towards the subcutaneous vasculature of the chest. In a cohort of 15 healthy male subjects, a total of 462 simultaneous readings consisting of reference MAP and chest PTT were acquired. Each subject was recorded at three different days: D, D+3 and D+14. Overall, the implemented protocol induced MAP values to range from 80 ± 6 mmHg in baseline, to 107 ± 9 mmHg during isometric handgrip maneuvers. Agreement between reference and chest-sensor MAP values was tested by using intraclass correlation coefficient (ICC = 0.78) and Bland-Altman analysis (mean error = 0.7 mmHg, standard deviation = 5.1 mmHg). The cumulative percentage of MAP values provided by the chest sensor falling within a range of ±5 mmHg compared to reference MAP readings was of 70%, within ±10 mmHg was of 91%, and within ±15mmHg was of 98%. These results point at the fact that the chest sensor complies with the British Hypertension Society (BHS) requirements of Grade A BP monitors, when applied to MAP readings. Grade A performance was maintained even two weeks after having performed the initial subject-dependent calibration. In conclusion, this paper introduces a sensor and a calibration strategy to perform MAP measurements at the chest. The encouraging performance of the presented technique paves the way towards an ambulatory-compliant, continuous and non-occlusive BP monitoring system.