741 resultados para Intrabladder catheter


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND For patients with acute iliofemoral deep vein thrombosis, it remains unclear whether the addition of intravascular high-frequency, low-power ultrasound energy facilitates the resolution of thrombosis during catheter-directed thrombolysis. METHODS AND RESULTS In a controlled clinical trial, 48 patients (mean age 50±21 years, 52% women) with acute iliofemoral deep vein thrombosis were randomized to receive ultrasound-assisted catheter-directed thrombolysis (N=24) or conventional catheter-directed thrombolysis (N=24). Thrombolysis regimen (20 mg r-tPA over 15 hours) was identical in all patients. The primary efficacy end point was the percentage of thrombus load reduction from baseline to 15 hours according to the length-adjusted thrombus score, obtained from standardized venograms and evaluated by a core laboratory blinded to group assignment. The percentage of thrombus load reduction was 55%±27% in the ultrasound-assisted catheter-directed thrombolysis group and 54%±27% in the conventional catheter-directed thrombolysis group (P=0.91). Adjunctive angioplasty and stenting was performed in 19 (80%) patients and in 20 (83%) patients, respectively (P>0.99). Treatment-related complications occurred in 3 (12%) and 2 (8%) patients, respectively (P>0.99). At 3-month follow-up, primary venous patency was 100% in the ultrasound-assisted catheter-directed thrombolysis group and 96% in the conventional catheter-directed thrombolysis group (P=0.33), and there was no difference in the severity of the post-thrombotic syndrome (mean Villalta score: 3.0±3.9 [range 0-15] versus 1.9±1.9 [range 0-7]; P=0.21), respectively. CONCLUSIONS In this randomized controlled clinical trial of patients with acute iliofemoral deep vein thrombosis treated with a fixed-dose catheter thrombolysis regimen, the addition of intravascular ultrasound did not facilitate thrombus resolution. CLINICAL TRIAL REGISTRATION URL http://www.clinicaltrials.gov. Unique identifier: NCT01482273.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND In the meantime, catheter ablation is widely used for the treatment of persistent atrial fibrillation (AF). There is a paucity of data about long-term outcomes. This study evaluates (1) 5-year single and multiple procedure success and (2) prognostic factors for arrhythmia recurrences after catheter ablation of persistent AF using the stepwise approach aiming at AF termination. METHODS AND RESULTS A total of 549 patients with persistent AF underwent de novo catheter ablation using the stepwise approach (2007-2009). A total of 493 patients were included (Holter ECGs ≥ every 6 months). Mean follow-up was 59 ± 16 months with 2.1 ± 1.1 procedures per patient. Single and multiple procedure success rates were 20.1% and 55.9%, respectively (80% off antiarrhythmic drug). Antiarrhythmic drug-free multiple procedure success was 46%. Long-term recurrences (n=171) were paroxysmal AF in 48 patients (28%) and persistent AF/atrial tachycardia in 123 patients (72%). Multivariable recurrent event analysis revealed the following factors favoring arrhythmia recurrence: failure to terminate AF during index procedure (hazard ratio [HR], 1.279; 95% confidence interval [CI], 1.093-1.497; P = 0.002), number of procedures (HR, 1.154; 95% CI, 1.051-1.267; P = 0.003), female sex (HR, 1.263; 95% CI, 1.027-1.553; P = 0.027), and the presence of structural heart disease (HR, 1.236; 95% CI, 1.003-1.524; P = 0.047). AF termination was correlated with a higher rate of consecutive procedures because of atrial tachycardia recurrences (P = 0.003; HR, 1.71; 95% CI, 1.20-2.43). CONCLUSIONS Catheter ablation of persistent AF using the stepwise approach provides limited long-term freedom of arrhythmias often requiring multiple procedures. AF termination, the number of procedures, sex, and the presence of structural heart disease correlate with outcome success. AF termination is associated with consecutive atrial tachycardia procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The analgesic effects of peripheral nerve blocks can be prolonged with the placement of perineural catheters allowing repeated injections of local anaesthetics in humans. The objectives of this study were to evaluate the clinical suitability of a perineural coiled catheter (PCC) at the sciatic nerve and to evaluate pain during the early post-operative period in dogs after tibial plateau levelling osteotomy. Pre-operatively, a combined block of the sciatic and the femoral nerves was performed under sonographic guidance (ropivacaine 0.5%; 0.3 mL kg−1 per nerve). Thereafter, a PCC was placed near the sciatic nerve. Carprofen (4 mg kg−1 intravenously) was administered at the end of anaesthesia. After surgery, all dogs were randomly assigned to receive four injections of ropivacaine (group R; 0.25%, 0.3 mL kg−1) or NaCl 0.9% (group C; 0.3 mL kg−1) every 6 h through the PCC. Pain was assessed by use of a visual analogue scale (VAS) and a multi-dimensional pain score (4Avet) before surgery (T-1), for 390 min (T0, T30, T60, T120, T180, T240, T300, T360 and T390) as well as 1 day after surgery (Day 1). Methadone (0.1 mg kg−1) was administered each time the VAS was ≥40 mm or the 4Avet was ≥5. At T390 dogs received buprenorphine (0.02 mg kg−1). Data were compared using Mann–Whitney rank sum tests and repeated measures analysis of variance. Regardless of group allocation, 55% of dogs required methadone. VAS was significantly lower at T390 (P = 0.003), and at Day 1 (P = 0.002) and so was 4Avet at Day 1 (P = 0.012) in group R than in group C. Bleeding occurred in one dog at PCC placement and PCC dislodged six times of 47 PCCs placed. Minor complications occurred with PCC but allowed four repeated administrations of ropivacaine or saline over 24 h in 91.5% of the cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION Mitral isthmus (MI) ablation is an effective option in patients undergoing ablation for persistent atrial fibrillation (AF). Achieving bidirectional conduction block across the MI is challenging, and predictors of MI ablation success remain incompletely understood. We sought to determine the impact of anatomical location of the ablation line on the efficacy of MI ablation. METHODS AND RESULTS A total of 40 consecutive patients (87% male; 54 ± 10 years) undergoing stepwise AF ablation were included. MI ablation was performed in sinus rhythm. MI ablation was performed from the left inferior PV to either the posterior (group 1) or the anterolateral (group 2) mitral annulus depending on randomization. The length of the MI line (measured with the 3D mapping system) and the amplitude of the EGMs at 3 positions on the MI were measured in each patient. MI block was achieved in 14/19 (74%) patients in group 1 and 15/21 (71%) patients in group 2 (P = NS). Total MI radiofrequency time (18 ± 7 min vs. 17 ± 8 min; P = NS) was similar between groups. Patients with incomplete MI block had a longer MI length (34 ± 6 mm vs. 24 ± 5 mm; P < 0.001), a higher bipolar voltage along the MI (1.75 ± 0.74 mV vs. 1.05 ± 0.69 mV; P < 0.01), and a longer history of continuous AF (19 ± 17 months vs. 10 ± 10 months; P < 0.05). In multivariate analysis, decreased length of the MI was an independent predictor of successful MI block (OR 1.5; 95% CI 1.1-2.1; P < 0.05). CONCLUSIONS Increased length but not anatomical location of the MI predicts failure to achieve bidirectional MI block during ablation of persistent AF.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND For chronic subdural hematoma, placement of a Blake drain with a two-burr-hole craniotomy is often preferred. However, the placement of such drains carries the risk of penetrating the brain surface or damaging superficial venous structures. OBJECTIVE To describe the use of a Nelaton catheter for the placement of a subdural drain in two-burr-hole trephination for chronic subdural hematoma. METHOD A Nelaton catheter was used to guide placement of a Blake drain into the subdural hematoma cavity and provide irrigation of the hematoma cavity. With the two-burr-hole method, the Nelaton catheter could be removed easily via the frontal burr hole after the Blake drain was in place. RESULTS We used the Nelaton catheters in many surgical procedures and found it a safe and easy technique. This method allows the surgeon to safely direct the catheter into the correct position in the subdural space. CONCLUSIONS This tool has two advantages. First, the use of a small and flexible Nelaton catheter is a safe method for irrigation of a chronic subdural hematoma cavity. Second, in comparison with insertion of subdural drainage alone through a burr hole, the placement of the Nelaton catheter in subdural space is easier and the risk of damaging relevant structures such as cortical tissue or bridging veins is lower. Thus this technique may help to avoid complications when placing a subdural drain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study has the purpose of determining the barriers and facilitators to nurses' acceptance of the Johnson and Johnson Protectiv®* Plus IV catheter safety needle device and implications for needlestick injuries at St. Luke's Episcopal Hospital, Houston, Texas. A one-time cross-sectional survey of 620 responding nurses was conducted by this researcher during December, 2000. The study objectives were to: (1) describe the perceived (a) organizational and individual barriers and facilitators and (b) acceptance of implementation of the IV catheter device; (2) examine the relative importance of these predictors; (3) describe (a) perceived changes in needlestick injuries after implementation of the device; (b) the reported incidence of injuries; and (c) the extent of underreporting by nurses; and (4) examine the relative importance of (a) the preceding predictors and (b) acceptance of the device in predicting perceived changes in needlestick injuries. Safety climate and training were evaluated as organizational factors. Individual factors evaluated were experience with the device, including time using it and frequency of use, and background information, including nursing unit, and length of time as a nurse in this hospital and in total nursing career. The conceptual framework was based upon the safety climate model. Descriptive statistics and multiple and logistic regression were utilized to address the study objectives. ^ The findings showed widespread acceptance of the device and a strong perception that it reduced the number of needlesticks. Acceptance was notably predicted by adequate training, appropriate time between training and device use, solid safety climate, and short length of service, in that order. A barrier to acceptance was nurses' longtime of use of previous needle technologies. Over four-fifths of nurses were compliant in always using the device. Compliance had two facilitators: length of time using device and, to a lesser extent, safety climate. Rates of compliance tended to be lower among nurses in units in which the device was frequently used. ^ High quality training and an atmosphere of caring about nurse safety stand out as primary facilitators that other institutions would need to adopt in order to achieve maximum success in implementing safety programs involving utilization of new safety devices. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A case-series analysis of approximately 811 cancer patients who developed Candidemia between 1989 and 1998 and seen at M. D. Anderson Cancer Center, was studied to assess the impact and timing of central venous catheter (CVC) removal on the outcome of fungal bloodstream infections in cancer patients with primary catheter-related Candidemia as well as secondary infections. ^ This study explored the diagnosis and the management of vascular catheter-associated fungemia in patients with cancer. The microbiologic and clinical factors were determined to predict catheter-related Candidemia. Those factors included, in addition to basic demographics, the underlying malignancy, chemotherapy, neutropenia, and other salient data. Statistical analyses included univariate and multivariate logistic regression to determine the outcome of Candidemia in relation to the timing of catheter removal, type of species, and to identify predictors of catheter-related infections. ^ The conclusions of the study aim at enhancing our mastery of issues involving CVC removal and potentially will have an impact on the management of nosocomial bloodstream infections related to timing of CVC removal and the optimal duration of treatment of catheter-related Candidemia. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Health care associated catheter related blood stream infections (CRBSI) represent a significant public health concern in the United States. Several studies have suggested that precautions such as maximum sterile barrier and use of antimicrobial catheters are efficacious at reducing CRBSI, but there is concern within the medical community that the prolonged use of antimicrobial catheters may be associated with increased bacterial resistance. Clinical studies have been done showing no association and a significant decrease in microbial resistance with prolonged minocycline/rifampin (M/R) catheter use. One explanation is the emergence of community acquired methicillin resistant Staphylococcus aureus (MRSA), which is more susceptible to antibiotics, as a cause of CRBSI.^ Methods. Data from 323 MRSA isolates cultured from cancer patients at The University of Texas MD Anderson Cancer center from 1997-2007 displaying MRSA infection were analyzed to determine whether there is a relationship between resistance to minocycline and rifampin and prolonged wide spread use of minocycline (M/R) catheters. Analysis was also conducted to determine whether there was a significant change in the prevalence community acquired MRSA (CA-MRSA) during this time period and if this emergence act as a confounder masquerading the true relationship between microbial resistance and prolonged M/R catheter use.^ Results. Our study showed that the significant (p=0.008) change in strain type over time is a confounding variable; the adjusted model showed a significant protective effect (OR 0.000281, 95% CI 1.4x10 -4-5.5x10-4) in the relationship between MRSA resistance to minocycline and prolonged M/R catheter use. The relationship between resistance to rifampin and prolonged M/R catheter use was not significant.^ Conclusion. The emergence of CA-MRSA is a confounder and in the relationship between resistance to minocycline and rifampin and prolonged M/R catheter use. However, despite the adjustment for the more susceptible CA-MRSA the widespread use of M/R catheters does not promote microbial resistance. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Catheter related bloodstream infections are a significant barrier to success in many inpatient healthcare facilities. The goal of this study was to analyze and determine if an evidence based methodology to reduce the number of catheter related bloodstream infections in a pediatric inpatient healthcare facility had significant impact on the infection rate. Catheter related bloodstream infection rates were compared before and after program implementation. The patient population was selected based upon a recommendation in the 2010 National Healthcare Safety Network report on device related infections. This report indicated a need for more data on pediatric populations requiring admission to a long term care facility. The study design is a retrospective cohort study. Catheter related bloodstream infection data was gathered between 2008 and 2011. In October of 2008 a program implementation began to reduce the number of catheter related bloodstream infections. The key components of this initiative were to implement a standardized catheter maintenance checklist, introduce the usage of a chlorhexadine gluconate based product for catheter maintenance and skin antisepsis, and a multidisciplinary education plan that focused on hand hygiene and aseptic technique. The catheter related bloodstream infection rate in 2008 was 21.21 infections per 1000 patient-line days. After program implementation the 2009 catheter related bloodstream infection rate dropped to 1.11 per 1000 patient-line days. The infection rates in 2010 and 2011 were 2.19 and 1.47 respectively. Additionally, this study demonstrated that there was a potential cost savings of $620,000 to $1,240,000 between 2008 and 2009. In conclusion, an evidence based program based upon CDC guidelines can have a significant impact on catheter related bloodstream infection rates. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The distinction between catheter-associated asymptomatic bacteriuria (CAABU) and catheter-associated urinary tract infection (CAUTI) has only recently been widely appreciated. Our aims were to describe the relationship between CAUTI/CAABU and subsequent bacteremia and to investigate whether CAUTI/CAABU and antimicrobial use was associated with either bacteremia or mortality within 30 days. ^ Methods: Our study design was retrospective cohort. Patients with a urinary catheter and a positive urine culture between October 2010 and June 2011 at a large tertiary care facility were included. A multivariable model for analysis was constructed which controlled for age, race, Charlson co-morbidity score, catheter type and duration, category of organism,antimicrobials and classification of the catheter-associated bacteriuria as CAUTI or CAABU. ^ Results: Data from 444 catheter associated urine culture episodes in 308 unique patients were included in the analysis. Overall mortality was 21.1% (61 of 308 patients) within 30 days. Among the 444 urine culture episodes, 402 (90.5%) of these episodes were associated with antibiotic use. 52 (11.7%) of episodes were associated with bacteremia, but only 3 episodes of bacteremia (0.7% of 444 CAB episodes) were caused by an organism from the urinary tract. One of these episodes was CAABU and the other 2 were CAUTI. Bacteremia within 30 days was associated with having CAUTI rather than CAABU and having an indwelling urinary catheter rather than a condom catheter. The variables which were found to be significant for mortality within 30 days were a higher Charlson co-morbidity score and the presence of Candida in the urine culture. Use of antimicrobial agents to treat the bacteriuria was not associated with an increase or decrease in either bacteremia or mortality. ^ Conclusions: Our findings call into question the practice of giving antimicrobial agents to treat bacteriuria in an inpatient population with nearly universal antimicrobial use. A better practice may be targeted treatment of bacteriuria in patients with risk factors predictive of bacteremia and mortality.^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An observational study was conducted in a SICU to determine the frequency of subclavian vein catheter-related infection at 72 hours, to identify the hospital cost of exchange via a guidewire and the estimated hospital cost-savings of a 72 hour vs 144 hour exchange policy.^ An overall catheter-related infection ($\geq$15 col. by Maki's technique (1977)) occurred in 3% (3/100) of the catheter tips cultured. Specific infections rates were: 9.7% (3/31) for triple lumen catheters, 0% (0/30) for Swan-Ganz catheters, 0% (0/30) for Cordes catheters, and 0% (0/9) for single lumen catheters.^ An estimated annual hospital cost-savings of $35,699.00 was identified if exchange of 72 hour policy were changed to every 144 hours.^ It was recommended that a randomized clinical trial be conducted to determine the effect of changing a subclavian vein catheter via a guidewire every 72 hours vs 144 hours. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This case report describes removal of a knotted, subclavian, pulmonary artery catheter using a tracheostomy dilator. With this simple method an invasive procedure might be averted.