198 resultados para Interobserver
Resumo:
Background: The objective of this study was to evaluate the consistency, coherence, and interobserver reliability of the Portuguese version of the Scandinavian Stroke Scale (SSS) in a multicultural population of stroke. Methods: The SSS was translated, culturally adapted, and applied by two independent investigators. This was a randomized transverse study involving two groups: group 1 included 20 patients in the acute phase and group 2 included 20 patients in the subacute phase after stroke was confirmed by computed tomography with a pre-stroke modified Rankin Scale score of 0. Each patient also underwent National Institutes of Health Stroke Scale (NIHSS) evaluation at hospital entry and at the time of the SSS evaluation for correlation with our current standard hospital practice. Consistency and coherence were analyzed by Cronbach’s α and interobserver reliability by ĸ. Results: Forty patients were evaluated with 0.88 consistency and coherence in both stroke phases. Mean interobserver ĸ was 0.76, with reliability considered excellent and good for most scale items, and moderate for only the facial palsy item. Conclusion: The SSS is adequate and validated to study post-stroke patients in a multicultural Brazilian population and in the Portuguese language.
Resumo:
Introduction: The objective of the study was to evaluate the ability of large-volume cone-beam computed tomography (CBCT) to detect horizontal root fracture and to test the influence of a metallic post. Methods: Through the examination of 40 teeth by large-volume CBCT (20-cm height and 15-cm diameter cylinder) at 0.2-mm voxel resolution, 2 observers analyzed the samples for the presence and localization of horizontal root fracture. Results: The values of accuracy in the groups that had no metallic post ranged from 33%-68%, whereas for the samples with the metallic post, values showed a wide variation (38%-83%). Intraobserver agreement showed no statistically significant difference between the groups with/without metallic post; both ranged from very weak to weak (kappa, 0.09-0.369). Conclusions: The low accuracy and low intraobserver and interobserver agreement reflect the difficulty in performing an adequate diagnosis of horizontal root fractures through a large-volume CBCT by using a small voxel reconstruction. (J Endod 2012;38:856-859)
Resumo:
The purpose of the present study was to determine ultrasound (US) arthrography diagnostic accuracy in patients with recurrent shoulder dislocation by comparing US arthrography and magnetic resonance arthrography (MRA) with intraoperative findings. Fifty-six consecutive patients with diagnosis of chronic anterior instability of the shoulder were evaluated for assessment of bone and soft tissue lesions by three radiologists. Twenty-five cases were confirmed by surgery. Sensitivity, specificity, inter-and intraobserver agreement were calculated. Ultrasound sensitivity ranged from 20% to 100% and specificity from 25% to 90%. MRA sensitivity ranged from 80% to 100% and specificity from 50% to 100%. Interobserver agreement was good for MRA (0.54-0.70) and fair for US arthrography (0.19-0.40). Despite a higher interobserver variability for US arthrography than for MRA, our results indicate that US is capable of demonstrating bone and soft tissue lesions related to chronic instability of the shoulder in the presence of intra-articular fluid. (E-mail: marcelo_simao@hotmail.com) (C) 2012 World Federation for Ultrasound in Medicine & Biology.
Resumo:
Impairment due to narcolepsy strongly limits job performance, but there are no standard criteria to assess disability in people with narcolepsy and a scale of disease severity is still lacking. We explored: 1. the interobserver reliability among Italian Medical Commissions making disability and handicap benefit decisions for people with narcolepsy, searching for correlations between the recognized disability degree and patients’ features; 2. the willingness to report patients to the driving licence authority; 3. possible sources of variance in judgement. Fifteen narcoleptic patients were examined by four Medical Commissions in simulated sessions. Raw agreement and interobserver reliability among Commissions were calculated for disability and handicap benefit decisions and for driving licence decisions. Levels of judgement differed on percentage of disability (p<0.001), severity of handicap (p=0.0007) and the need to inform the driving licence authority (p=0.032). Interobserver reliability ranged from Kappa = - 0.10 to Kappa = 0.35 for disability benefit decision and from Kappa = - 0.26 to Kappa = 0.36 for handicap benefit decision. The raw agreement on driving licence decision ranged from 73% to 100% (Kappa not calculable). Spearman’s correlation between percentages of disability and patients’ features showed correlations with age, daytime naps, sleepiness, cataplexy and quality of life. This first interobserver reliability study on social benefit decisions for narcolepsy shows the difficulty of reaching an agreement in this field, mainly due to variance in interpretation of the assessment criteria. The minimum set of indicators of disease severity correlating with patients’ self assessments encourages a disability classification of narcolepsy.
Resumo:
Auf der Suche nach dem „vulnerablen Plaque“, der ein besonders hohes Risiko für Schlaganfall und Herzinfarkt besitzt, findet momentan ein Paradigmenwechsel statt. Anstelle des klassischen Stenosegrades gewinnt die Darstellung der Plaquemorphologie zunehmend an Bedeutung. Fragestellung: Ziel dieser Arbeit ist es, die Fähigkeiten eines modernen 16-Kanal-CT hinsichtlich der Auflösung des Plaqueinneren bei Atherosklerose der Karotiden zu untersuchen und den Halo-Effekt in vivo zu erforschen. Methoden: Für die Studie wurden von 28 Patienten mit bekannter, symptomatischer Karotisstenose vor der gefäßchirurgischen Intervention CT-Bilder angefertigt, die nachfolgend mit der Histologie der Gefäßpräparate korreliert wurden. Auf diese Weise konnten die mikroskopisch identifizierten Lipidkerne im CT-Bild eingezeichnet und hinsichtlich ihrer Fläche und Dichtewerte evaluiert werden. In einem weiteren Schritt führten 2 Radiologen in Unkenntnis der histologischen Ergebnisse unabhängig voneinander eine Befundung durch und markierten mutmaßliche Lipidkerne. Zudem wurden sowohl in der verblindeten als auch in der histologiekontrollierten Auswertung die Plaquetypen anhand der AHA-Klassifikation bestimmt. Ein dritter Befundungsdurchgang geschah unter Zuhilfenahme einer von uns entwickelten Software, die CT-Bilder farbkodiert um die Detektion der Lipidkerne zu verbessern. Anhand der Farbkodierung wurde zudem ein Indexwert errechnet, der eine objektive Zuordnung zur AHA-Klassifikation ermöglichen sollte. Von 6 Patienten wurde zusätzlich noch eine native CT-Aufnahme angefertigt, die durch MPR exakt an die Kontrastmittelserie angeglichen wurde. Auf diese Weise konnte der Halo-Effekt, der die Plaqueanteile im lumennahen Bereich überstrahlt, quantifiziert und charakterisiert werden. Ergebnisse: Während die Einstufung in die AHA-Klassifikation sowohl durch den Befunder als auch durch den Softwarealgorithmus eine hohe Korrelation mit der Histologie aufweist (Typ IV/Va: 89 %, Typ Vb: 70 %, Typ Vc: 89 %, Typ VI: 55 %), ist die Detektion der Lipidkerne in beiden Fällen nicht ausreichend gut und die Befunderabhängigkeit zu groß (Cohens Kappa: 18 %). Eine Objektivierung der AHA-Klassifikation der Plaques durch Indexberechnung nach Farbkodierung scheint möglich, wenn auch dem Befunder nicht überlegen. Die fibröse Kappe kann nicht abgegrenzt werden, da Überstrahlungseffekte des Kontrastmittels dessen HU-Werte verfälschen. Dieser Halo-Effekt zeigte sich im Median 1,1 mm breit mit einer Standardabweichung von 0,38 mm. Eine Abhängigkeit von der Kontrastmitteldichte im Gefäßlumen konnte dabei nicht nachgewiesen werden. Der Halo-Effekt fiel im Median um -106 HU/mm ab, bei einer Standardabweichung von 33 HU/mm. Schlussfolgerung: Die CT-Technologie zeigt sich, was die Darstellung von einzelnen Plaquekomponenten angeht, den bekannten Fähigkeiten der MRT noch unterlegen, insbesondere in Bezug auf die fibröse Kappe. Ihre Fähigkeiten liegen bisher eher in der Einstufung von Plaques in eine grobe Klassifikation, angelehnt an die der AHA. Die klinische Relevanz dessen jedoch gilt es in Zukunft in größeren Studien weiter zu untersuchen. Auch lässt die Weiterentwicklung der Computertomographie auf eine zukünftig höhere Auflösung der Plaquemorphologie hoffen.
Resumo:
Objective : To compare two scoring systems: the Huddart/Bodenham system (HB system) and the Bauru-BCLP yardstick (BCLP yardstick), which classify treatment outcome in terms of dental arch relationships in patients with complete bilateral cleft lip and palate (CBCLP). The predictive value of these scoring systems for treatment outcome was also evaluated. Design : Retrospective longitudinal study. Patients : Dental arch relationships of 43 CBCLP patients were evaluated at 6, 9, and 12 years. Setting : Treatment outcome in BCLP patients using two scoring systems. Main Outcome Measures : For each age group, the HB scores were correlated with the BCLP yardstick scores using Spearman's correlation coefficient. The predictive value of the two scoring systems was evaluated by backward regression analysis. Results : Intraobserver Kappa values for the BCLP yardstick scoring for the two observers were .506 and .627, respectively, and the interobserver reliability ranged from .427 and .581. The intraobserver reliability for the HB system ranged from .92 to .97 and the interobserver reliability from .88 to .96. The BCLP yardstick scores of 6 and 9 years together were predictors for the outcome at 12 years (explained variance 41.3%). Adding the incisor and lateral HB scores in the regression model increased the explained variance to 67%. Conclusions : The BCLP yardstick and the HB system are reliable scoring systems for evaluation of dental arch relationships of CBCLP patients. The HB system categorizes treatment outcome into similar categories as the BCLP yardstick. In case a more sensitive measure of treatment outcome is needed, selectively both scoring systems should be used.
Resumo:
This pilot study defines the feasibility of cartilage assessment in symptomatic femoroacetabular impingement patients using intra-articular delayed gadolinium-enhanced MRI of cartilage (ia-dGEMRIC). Nine patients were scanned preliminary to study the contrast infiltration process into hip joint cartilage. Twenty-seven patients with symptomatic femoroacetabular impingement were subsequently scanned with intra-articular delayed gadolinium-enhanced MRI of cartilage. These T(1) findings were correlated to morphological findings. Zonal variations were studied. This pilot study demonstrates a significant difference between the pre- and postcontrast T(1) values (P < 0.001) remaining constant for 45 min. We noted higher mean T(1) values in morphologically normal-appearing cartilage than in damaged cartilage, which was statistically significant for all zones except the anterior-superior zone. Intraobserver (0.972) and interobserver correlation coefficients (0.933) were statistically significant. This study outlines the feasibility of intra-articular delayed gadolinium-enhanced MRI of cartilage for assessment of cartilage changes in patients with femoroacetabular impingement. It can also define the topographic extent and differing severities of cartilage damage.
Resumo:
Therapy of metacarpal neck fractures depending on radiographically measured palmar angulation is discussed controversially in the literature. Some authors describe normal hand function of malunited metacarpal neck fractures with a palmar angulation up to 70°; others define 30° as the uppermost limit to maintain normal hand function. However, the methods of measuring palmar angulation are not clearly defined. Here, we present a new method to measure palmar angulation using ultrasound. The aim of this prospective study is to compare the radiographic methods of measuring palmar angulation with the ultrasound method. PATIENTS/MATERIAL AND METHOD: 20 patients with a neck fracture of the metacarpals IV or V were treated either conservatively or operatively. 2 weeks after trauma or operation, an x-ray was performed. 2 examiners measured the palmar angulation on the oblique and lateral projections using 2 different methods (medullary canal and dorsal cortex methods). At the same time, the 2 examiners performed measurements of palmar angulation using ultrasound. The measurements obtained with the different methods as well as by the 2 examiners at 2 different terms were compared. Intra- and interobserver reliability of each method was calculated, and for the ultrasound method a test for accuracy of the measured angles was performed.
Resumo:
High-resolution ultrasound is becoming increasingly important in the diagnosis of carpal tunnel syndrome (CTS). Most studies define cut-off values of the cross-sectional area (CSA) of the median nerve in different locations. The individual range of nerve swelling, the size of the nerve, and its CSA are not addressed. The aim of the study is to define the intra- and interobserver reliability of diagnostic ultrasound using two different cross-sectional areas of the median nerve at the carpal tunnel in predefined locations.
Resumo:
BACKGROUND: The aim of this study was to develop a child-specific classification system for long bone fractures and to examine its reliability and validity on the basis of a prospective multicentre study. METHODS: Using the sequentially developed classification system, three samples of between 30 and 185 paediatric limb fractures from a pool of 2308 fractures documented in two multicenter studies were analysed in a blinded fashion by eight orthopaedic surgeons, on a total of 5 occasions. Intra- and interobserver reliability and accuracy were calculated. RESULTS: The reliability improved with successive simplification of the classification. The final version resulted in an overall interobserver agreement of κ = 0.71 with no significant difference between experienced and less experienced raters. CONCLUSIONS: In conclusion, the evaluation of the newly proposed classification system resulted in a reliable and routinely applicable system, for which training in its proper use may further improve the reliability. It can be recommended as a useful tool for clinical practice and offers the option for developing treatment recommendations and outcome predictions in the future.
Resumo:
An automated algorithm for detection of the acetabular rim was developed. Accuracy of the algorithm was validated in a sawbone study and compared against manually conducted digitization attempts, which were established as the ground truth. The latter proved to be reliable and reproducible, demonstrated by almost perfect intra- and interobserver reliability. Validation of the automated algorithm showed no significant difference compared to the manually acquired data in terms of detected version and inclination. Automated detection of the acetabular rim contour and the spatial orientation of the acetabular opening plane can be accurately achieved with this algorithm.
Resumo:
Yardsticks have been developed to measure dental arch relations in cleft lip and palate (CLP) patients as diagnostic proxies for the underlying skeletal relationship. Travelling with plaster casts to compare results between CLP centres is inefficient so the aim of this study was to investigate the reliability of using digital models or photographs of dental casts instead of plaster casts for rating dental arch relationships in children with complete bilateral cleft lip and palate (CBCLP). Dental casts of children with CBCLP (n=20) were included. Plaster casts, digital models and photographs of the plaster casts were available for all the children at 6, 9, and 12 years of age. All three record formats were scored using the bilateral cleft lip and palate (BCLP) yardstick by four observers in random order. No significant differences were found for the BCLP yardstick scores among the three formats. The interobserver weighted kappa scores were between 0.672 and 0.934. Comparison between the formats per observer resulted in weighted kappa scores between 0.692 and 0.885. It is concluded that digital models and photographs of dental casts can be used for rating dental arch relationships in patients with CBCLP. These formats are a reliable alternative for BCLP yardstick assessments on conventional plaster casts.
Resumo:
Tumor budding is recognized by the World Health Organization as an additional prognostic factor in colorectal cancer but remains unreported in diagnostic work due to the absence of a standardized scoring method. This study aims to assess the most prognostic and reproducible scoring systems for tumor budding in colorectal cancer. Tumor budding on pancytokeratin-stained whole tissue sections from 105 well-characterized stage II patients was scored by 3 observers using 7 methods: Hase, Nakamura, Ueno, Wang (conventional and rapid method), densest high-power field, and 10 densest high-power fields. The predictive value for clinicopathologic features, the prognostic significance, and interobserver variability of each scoring method was analyzed. Pancytokeratin staining allowed accurate evaluation of tumor buds. Interobserver agreement for 3 observers was excellent for densest high-power field (intraclass correlation coefficient, 0.83) and 10 densest high-power fields (intraclass correlation coefficient, 0.91). Agreement was moderate to substantial for the conventional Wang method (κ = 0.46-0.62) and moderate for the rapid method (κ = 0.46-0.58). For Nakamura, moderate agreement (κ = 0.41-0.52) was reached, whereas concordance was fair to moderate for Ueno (κ = 0.39-0.56) and Hase (κ = 0.29-0.51). The Hase, Ueno, densest high-power field, and 10 densest high-power field methods identified a significant association of tumor budding with tumor border configuration. In multivariate analysis, only tumor budding as evaluated in densest high-power field and 10 densest high-power fields had significant prognostic effects on patient survival (P < .01), with high prognostic accuracy over the full 10-year follow-up. Scoring tumor buds in 10 densest high-power fields is a promising method to identify stage II patients at high risk for recurrence in daily diagnostics; it is highly reproducible, accounts for heterogeneity, and has a strong predictive value for adverse outcome.
Resumo:
Puppa G, Senore C, Sheahan K, Vieth M, Lugli A, Zlobec I, Pecori S, Wang L M, Langner C, Mitomi H, Nakamura T, Watanabe M, Ueno H, Chasle J, Conley S A, Herlin P, Lauwers G Y & Risio M (2012) Histopathology Diagnostic reproducibility of tumour budding in colorectal cancer: a multicentre, multinational study using virtual microscopy Aims: Despite the established prognostic relevance of tumour budding in colorectal cancer, the reproducibility of the methods reported for its assessment has not yet been determined, limiting its use and reporting in routine pathology practice. Methods and results: A morphometric system within telepathology was devised to evaluate the reproducibility of the various methods published for the assessment of tumour budding in colorectal cancer. Five methods were selected to evaluate the diagnostic reproducibility among 10 investigators, using haematoxylin and eosin (H&E) and AE1-3 cytokeratin-immunostained, whole-slide digital scans from 50 pT1-pT4 colorectal cancers. The overall interobserver agreement was fair for all methods, and increased to moderate for pT1 cancers. The intraobserver agreement was also fair for all methods and moderate for pT1 cancers. Agreement was dependent on the participants' experience with tumour budding reporting and performance time. Cytokeratin immunohistochemistry detected a higher percentage of tumour budding-positive cases with all methods compared to H&E-stained slides, but did not influence agreement levels. Conclusions: An overall fair level of diagnostic agreement for tumour budding in colorectal cancer was demonstrated, which was significantly higher in early cancer and among experienced gastrointestinal pathologists. Cytokeratin immunostaining facilitated detection of budding cancer cells, but did not result in improved interobserver agreement.
Resumo:
The purpose of this study was to compare inter-observer agreement of Stratus™ OCT versus Spectralis™ OCT image grading in patients with neovascular age-related macular degeneration (AMD). Thirty eyes with neovascular AMD were examined with Stratus™ OCT and Spectralis™ OCT. Four different scan protocols were used for imaging. Three observers graded the images for the presence of various pathologies. Inter-observer agreement between OCT models was assessed by calculating intra-class correlation coefficients (ICC). In Stratus™ OCT highest interobserver agreement was found for subretinal fluid (ICC: 0.79), and in Spectralis™ OCT for intraretinal cysts (IRC) (ICC: 0.93). Spectralis™ OCT showed superior interobserver agreement for IRC and epiretinal membranes (ERM) (ICC(Stratus™): for IRC 0.61; for ERM 0.56; ICC(Spectralis™): for IRC 0.93; for ERM 0.84). Increased image resolution of Spectralis™ OCT did improve the inter-observer agreement for grading intraretinal cysts and epiretinal membranes but not for other retinal changes.