962 resultados para Image findings
Resumo:
What different forms of engagement do image and text allow the spectator/reader? We know that text and image communicate, and that all communication depends on a relationship between those who communicate. The objective of this text is therefore to understand the new possibilities available to an anthropology of the expression of knowledge that makes use of images, such as photographs and films.
Resumo:
Hemochromatosis can be classified as (a) primary, when it originates from a genetic disturbance that promotes the increase of iron absorption, or (b) secondary, when it relates to chronic diseases or to multiple transfusions. The distribution of iron accumulation differs between these two forms; therefore, they can be distinguished by using imaging methods in the majority of cases. Magnetic resonance (MR) imaging is the most sensitive and specific imaging modality in the diagnosis of hemochromatosis. The susceptibility effect caused by the accumulation of iron leads to signal loss in the affected tissues, particularly with the T2*-weighted sequences, which makes the diagnosis of iron overload possible. By using MR imaging techniques, it is possible to estimate the hepatic iron concentration in a noninvasive way, thereby avoiding repeated biopsies. Hemochromatosis can lead to complications, such as a higher frequency of neoplasia, particularly the development of hepatocellular carcinoma. Other neoplasms, such as colorectal tumors, are also associated. Complications related to the treatment of chronic anemia include the appearance of peliosis hepatis and tumors, which can regress after the suspension of treatment with drugs. Knowledge of the disease and of the patterns of iron deposition in patients with iron overload enables not only diagnosis, but also treatment, follow-up, and the detection of possible complications by using imaging methods. (C) RSNA, 2009 . radiographics.rsna.org
Resumo:
Objectives: Lung hyperinflation may be assessed by computed tomography (CT). As shown for patients with emphysema, however, CT image reconstruction affects quantification of hyperinflation. We studied the impact of reconstruction parameters on hyperinflation measurements in mechanically ventilated (MV) patients. Design: Observational analysis. Setting: A University hospital-affiliated research Unit. Patients: The patients were MV patients with injured (n = 5) or normal lungs (n = 6), and spontaneously breathing patients (n = 5). Interventions: None. Measurements and results: Eight image series involving 3, 5, 7, and 10 mm slices and standard and sharp filters were reconstructed from identical CT raw data. Hyperinflated (V-hyper), normally (V-normal), poorly (V-poor), and nonaerated (V-non) volumes were calculated by densitometry as percentage of total lung volume (V-total). V-hyper obtained with the sharp filter systematically exceeded that with the standard filter showing a median (interquartile range) increment of 138 (62-272) ml corresponding to approximately 4% of V-total. In contrast, sharp filtering minimally affected the other subvolumes (V-normal, V-poor, V-non, and V-total). Decreasing slice thickness also increased V-hyper significantly. When changing from 10 to 3 mm thickness, V-hyper increased by a median value of 107 (49-252) ml in parallel with a small and inconsistent increment in V-non of 12 (7-16) ml. Conclusions: Reconstruction parameters significantly affect quantitative CT assessment of V-hyper in MV patients. Our observations suggest that sharp filters are inappropriate for this purpose. Thin slices combined with standard filters and more appropriate thresholds (e.g., -950 HU in normal lungs) might improve the detection of V-hyper. Different studies on V-hyper can only be compared if identical reconstruction parameters were used.
Resumo:
Objective: To compare clinical evaluation, electrophysiological investigation and magnetic resonance findings in assessing the severity of idiopathic carpal tunnel syndrome. Patients and methods: Seventy-four patients with idiopathic carpal tunnel syndrome were prospectively recruited. Clinical evaluation included symptoms severity score and two-point discrimination, sensory and motor nerve conduction velocities were determined by electroneuromyography and imaging parameters were obtained after wrist magnetic resonance. The Wilcoxon test was used to define the differences between measurements of median nerve area. The Pearson and Spearman correlation tests were used to determine the relationships between all the measured parameters. Results: Cross-sectional area of median nerve was smaller at hamate level than at radio-ulnar joint and pisiform levels (p < 0.001). With exception of median nerve area at hamate level, there was a lower degree of correlation between MRI parameters and findings obtained by clinical assessments and electrophysiological measurements. The median nerve area at hamate level correlated negatively with duration of symptoms, two-point discrimination, symptoms severity score and positively with sensory nerve conduction velocity (P < 0.01). Conclusion: In patients with idiopathic carpal tunnel syndrome, median nerve area measured by wrist magnetic resonance at hamate level may be considered as a valuable indicator to grading the severity of disease. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
Previous studies have reported differences in presenting symptoms and angiographic characteristics between women and men undergoing evaluation for suspected coronary artery disease (CAD). We examined the relation between symptoms and extent of CAD in patients with type 2 diabetes mellitus and known CAD enrolled in the Bypass Angioplasty Revascularization Investigation 2 Diabetes (BARI 2D) trial. Of 1,775 patients (533 women, 30%, and 1,242 men, 70%), women were more likely than men to have angina (65% vs 56%, p < 0.001) or an atypical angina/anginal equivalent (71% vs 58%, p < 0.001). More women reported unstable angina (17% vs 13%, p = 0.047) or were in a higher Canadian Cardiology Society class compared to men (Canadian Cardiology Society classes II to IV 78% vs 68%, p = 0.002). Fewer women than men had no symptoms (14% vs 22%, p < 0.001). Women had a lower mean myocardial jeopardy index (42.5 +/- 24.3 vs 47.9 +/- 24.3, p < 0.001), smaller number of total significant lesions (2.3 +/- 17 1.7 vs 2.7 +/- 1.8, p < 0.001), and fewer jeopardized left ventricular regions (p < 0.001 for distribution) or long-term occlusions (29% vs 42%, p < 0.001). After adjustment for relevant covariates, the odds of having CAD symptoms were still higher in women than men (odds ratio for angina 1.31, 95% confidence interval 1.02 to 1.69; odds ratio for atypical angina 1.52, 95% confidence interval 1.17 to 1.96). In conclusion, in a high-risk group of patients with known CAD and diabetes mellitus, women were more symptomatic than men but had less obstructive CAD. These data suggest that factors other than epicardial CAD severity influence symptom presentation in women in this population. (C) 2011 Elsevier Inc. All rights reserved. (Am J Cardiol 2011;107:980-985)
Resumo:
Arteriovenous fistula involving renal artery and inferior vena cava are rare. We report the case of a 47-year-old woman with a chronic arteriovenous fistula between right renal artery and inferior vena cava due to a penetrating trauma. Another finding was a vena cava aneurysm caused by the fistula. The patient was successfully treated with a covered stent in the renal artery. Diagnosis and postoperative control have been documented with CT scan. Endovascular techniques may be effective and minimally invasive option for treatment and renal preservation in renal-cava arteriovenous fistulae.
Resumo:
Objective: To investigate the possible role of chromatin texture parameters, nuclear morphology, DNA ploidy and clinical functional status in discriminating benign from malignant adrenocortical tumors (ACT). Patients and Methods: Forty-eight cases of clinically benign (n=40) and clinically malignant (n=8) ACT with a minimum of 5-years` follow-up were evaluated for chromatin texture parameters (run length, standard deviation, configurable run length, valley, slope, peak and other 21 Markovian features that describe the distribution of the chromatin in the nucleus), nuclear morphology (nuclear area, nuclear perimeter, nuclear maximum and minumum diameter, nuclear shape), and DNA ploidy. Nuclear parameters were evaluated in Feulgen-stained 5 mu m paraffin-sections analyzed using a CAS 200 image analyzer. Results: Since ACTs present different biological features in children and adults, patients were divided into two groups: children (<= 15 years) and adults (>15 years). In the group of children DNA ploidy presented a marginal significance (p=0.05) in discriminating ACTs. None of the parameters discriminated between malignant and benign ACT in the adult group. Conclusion: ACTs are uncommon and definitive predictive criteria for malignancy remain uncertain, particularly in children. Our data point to DNA content evaluated by image analysis as a new candidate tool for this challenging task. Texture image analysis did not help to differentiate malignant from benign adrenal cortical tumors in children and adults.
Resumo:
This paper summarises the major findings from the Quake Impact Study (QIS), a four-phase longitudinal project that was conducted in the aftermath of the 1989 Newcastle (Australia) earthquake. A total of 3,484 subjects participated in at least one component of the QIS, comprising a stratified sample of 3,007 drawn from community electoral rolls and 477 from specially targeted supplementary samples (the injured, the displaced, the owners of damaged businesses, and the helpers). Subjects' initial earthquake experiences were rated in terms of weighted indices of exposure to threat and disruption. Psychological morbidity was measured at each phase using the General Health Questionnaire (GHQ-12) and the Impact of Event Scale (IES). Selected findings and key conclusions are presented for each of six areas of investigation: service utilisation during the first 6 months post-disaster; patterns of earthquake experience and short-term (6-month) psychosocial outcome; earthquake exposure and medium term (2-year) psychosocial outcome; vulnerability factors and medium-term psychosocial outcome: specific community groups at increased risk (e.g., the elderly and immigrants from non-English-speaking backgrounds); the effects of stress debriefing for helpers. Threshold morbidity (i.e., likely caseness) rates are also presented for a broad range of subgroups. In addition to presenting an overview of the QIS, this paper synthesises the major findings and discusses their implications for future disaster management and research from a mental health perspective.
Resumo:
Cryoablative therapies have been proposed to palliate pain from soft-tissue or osteolytic bone tumors. A case of a patient with painful thoracic and sacral spine sclerotic metastases successfully treated by image-guided percutaneous cryoablation with the aid of insulation techniques and thermosensors is reported in this case report.
Resumo:
Radiation dose calculations in nuclear medicine depend on quantification of activity via planar and/or tomographic imaging methods. However, both methods have inherent limitations, and the accuracy of activity estimates varies with object size, background levels, and other variables. The goal of this study was to evaluate the limitations of quantitative imaging with planar and single photon emission computed tomography (SPECT) approaches, with a focus on activity quantification for use in calculating absorbed dose estimates for normal organs and tumors. To do this we studied a series of phantoms of varying complexity of geometry, with three radionuclides whose decay schemes varied from simple to complex. Four aqueous concentrations of (99m)Tc, (131)I, and (111)In (74, 185, 370, and 740 kBq mL(-1)) were placed in spheres of four different sizes in a water-filled phantom, with three different levels of activity in the surrounding water. Planar and SPECT images of the phantoms were obtained on a modern SPECT/computed tomography (CT) system. These radionuclides and concentration/background studies were repeated using a cardiac phantom and a modified torso phantom with liver and ""tumor"" regions containing the radionuclide concentrations and with the same varying background levels. Planar quantification was performed using the geometric mean approach, with attenuation correction (AC), and with and without scatter corrections (SC and NSC). SPECT images were reconstructed using attenuation maps (AM) for AC; scatter windows were used to perform SC during image reconstruction. For spherical sources with corrected data, good accuracy was observed (generally within +/- 10% of known values) for the largest sphere (11.5 mL) and for both planar and SPECT methods with (99m)Tc and (131)I, but were poorest and deviated from known values for smaller objects, most notably for (111)In. SPECT quantification was affected by the partial volume effect in smaller objects and generally showed larger errors than the planar results in these cases for all radionuclides. For the cardiac phantom, results were the most accurate of all of the experiments for all radionuclides. Background subtraction was an important factor influencing these results. The contribution of scattered photons was important in quantification with (131)I; if scatter was not accounted for, activity tended to be overestimated using planar quantification methods. For the torso phantom experiments, results show a clear underestimation of activity when compared to previous experiment with spherical sources for all radionuclides. Despite some variations that were observed as the level of background increased, the SPECT results were more consistent across different activity concentrations. Planar or SPECT quantification on state-of-the-art gamma cameras with appropriate quantitative processing can provide accuracies of better than 10% for large objects and modest target-to-background concentrations; however when smaller objects are used, in the presence of higher background, and for nuclides with more complex decay schemes, SPECT quantification methods generally produce better results. Health Phys. 99(5):688-701; 2010
Resumo:
Resting state functional magnetic resonance imaging (fMRI) reveals a distinct network of correlated brain function representing a default mode state of the human brain The underlying structural basis of this functional connectivity pattern is still widely unexplored We combined fractional anisotropy measures of fiber tract integrity derived from diffusion tensor imaging (DTI) and resting state fMRI data obtained at 3 Tesla from 20 healthy elderly subjects (56 to 83 years of age) to determine white matter microstructure e 7 underlying default mode connectivity We hypothesized that the functional connectivity between the posterior cingulate and hippocampus from resting state fMRI data Would be associated with the white matter microstructure in the cingulate bundle and fiber tracts connecting posterior cingulate gyrus With lateral temporal lobes, medial temporal lobes, and precuneus This was demonstrated at the p<0001 level using a voxel-based multivariate analysis of covariance (MANCOVA) approach In addition, we used a data-driven technique of joint independent component analysis (ICA) that uncovers spatial pattern that are linked across modalities. It revealed a pattern of white matter tracts including cingulate bundle and associated fiber tracts resembling the findings from the hypothesis-driven analysis and was linked to the pattern of default mode network (DMN) connectivity in the resting state fMRI data Out findings support the notion that the functional connectivity between the posterior cingulate and hippocampus and the functional connectivity across the entire DMN is based oil distinct pattern of anatomical connectivity within the cerebral white matter (C) 2009 Elsevier Inc All rights reserved
Resumo:
The present work is a report of the characterization of superparamagnetic iron oxide nanoparticles coated with silicone used as a contrast agent in magnetic resonance imaging of the gastrointestinal tract. The hydrodynamic size of the contrast agent is 281.2 rim, where it was determined by transmission electron microscopy and a Fe(3)O(4) crystalline structure was identified by X-ray diffraction, also confirmed by Mossbauer Spectroscopy. The blocking temperature of 190 K was determined from magnetic measurements based on the Zero Field Cooled and Field Cooled methods. The hysteresis loops were measured at different temperatures below and above the blocking temperature. Ferromagnetic resonance analysis indicated the superparamagnetic nature of the nanoparticles and a strong temperature dependence of the peak-to-peak linewidth Delta H(pp), giromagnetic factor g, number of spins N(S) and relaxation time T(2) were observed. This behavior can be attributed to an increase in the superexchange interaction.