806 resultados para Homomorphic e-Auction, Bid Validity Check, Batch Verification, Oblivious Transfer
Resumo:
The production of Long-R-3-IGF-1 (an IGF-1 fusion analog) by constant-rate, fed-batch fermentation of Escherichia coli yielded 2.6 g fusion protein/L, corresponding to an actual IGF-1 concentration of 2.2 g/L. A novel strategy employing three distinct feeding stages was developed which raised product concentration to 4.3 g/L (3.6 g/L of IGF-1) while minimising glucose and acetate accumulation. This improved productivity was not accompanied by an increase in inclusion body size.
Resumo:
The Direct Assessment of Functional Status-Revised (DAFS-R) is an instrument developed to objectively measure functional capacities required for independent living. The objective of this study was to translate and culturally adapt the DAFS-R for Brazilian Portuguese (DAFS-BR) and to evaluate its reliability and validity. The DAFS-BR was administered to 89 older patients classified previously as normal controls, mild cognitive impairment (MCI) and Alzheimer`s disease (AD). The results indicated good internal consistency (Cronbach`s alpha = 0.78) in the total sample. The DAFS-BR showed high interobserver reliability (0.996; p < .001) as well as test-retest stability over 1-week interval (0.995; p < .001). Correlation between the DAFS-BR total score and the Informant Questionnaire on Cognitive Decline in the Elderly (IQCODE) was moderate and significant (r = -.65, p < .001) in the total sample, whereas it did not reach statistical significance within each diagnostic group. Receiver operating characteristic curve analyses suggested that DAFS-BR has good sensitivity and specificity to identify MCI and AD. Results suggest that DAFS-BR can document degrees of severity of functional impairment among Brazilian older adults.
Resumo:
This study examined the validity of the self-reporting questionnaire (SRQ-20) in a population-based survey with older adults in Sao Paulo, Brazil. The study sample consisted of 2,008 individuals aged 65 years or more who were living in an economically disadvantaged area of the city. The geriatric mental state (GMS) was used as the gold standard for the assessment of common mental disorders (CMD). The optimal SRQ-20 threshold for case definition was 4/5 (sensitivity = 76.1%, specificity = 74.6%, area under ROC curve = 0.82). Women, older participants and those with lower income were more likely to be misclassified by the questionnaire. The inclusion of older persons with dementia or psychosis did not change the ability of the SRQ-20 to identify cases of CMD. The SRQ-20 may be a useful instrument to be used in large epidemiological studies in resource-poor settings for the identification of cases of depression and anxiety in later life. The performance of the SRQ-20 among older adults was similar to that observed with the adult population in Brazil.
Resumo:
Background: The perception of improvement by a patient has assumed a central role in functional evaluation after a variety of knee problems. One of the instruments most used in clinical research is the International Knee Documentation Committee (IKDC) Subjective Knee Form because its psychometric properties are considered to be excellent. Nonetheless, this questionnaire was originally developed for use in the English language. Therefore, to use this questionnaire in the Brazilian population, it is essential to translate and validate it. Purpose: The aim of this study was to translate the IKDC Subjective Knee Form into a Brazilian version and to test its validity and reproducibility. Study Design: Cohort study (diagnosis); Level of evidence, 2. Methods: The translation of the original IKDC Subjective Knee Form into a Brazilian version was accomplished in accordance with the American Orthopaedic Society for Sports Medicine guidelines and was tested in 32 patients with knee pathologic conditions to develop the first Brazilian version. To test validity and reproducibility, 117 patients with several knee complaints completed the Brazilian IKDC Subjective Knee Form, the Short Form 36 (SF-36), the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and the Lysholm score. From these patients, 85 were retested within a week to achieve reproducibility. The validation was addressed by correlating the Brazilian IKDC Subjective Knee Form to the other outcome measures. The reproducibility was tested by measuring internal consistency, test-retest reliability, and agreement. Results: The Brazilian IKDC Subjective Knee Form was highly related to the physical component summary of the SF-36, the Lysholm score, and the WOMAC, and weakly related to the mental component summary of SF-36 (r=.79, .89, .85, and .51, respectively). The internal consistency was strong, with a Cronbach a value of .928 and .935 in the test and retest assessment, respectively. The test-retest reliability proved to be excellent, with a high value of the intraclass correlation coefficient (.988), as well as the agreement, demonstrated by the low differences between the means of the test and retest, and the short limit of agreement, observed in the Altman-Bland and survival-agreement plots. Conclusion: The results of this study provide evidence that the Brazilian IKDC Subjective Knee Form has psychometric properties similar to the original version. In addition, it was a reliable evaluation instrument for patients with knee-related problems.
Resumo:
Objective: The purpose of this study was to investigate the reliability and validity of photogrammetry in measuring the lateral spinal inclination angles. Methods: Forty subjects (32 female and 8 males) with a mean age of 23.4 +/- 11.2 years had their scoliosis evaluated by radiographs of their trunk, determined by the Cobb angle method, and by photogrammetry. The statistical methods used included Cronbach alpha, Pearson/Spearman correlation coefficients, and regression analyses. Results: The Cronbach a values showed that the photogrammetric measures showed high internal consistency, which indicated that the sample was bias free. The radiograph method showed to be more precise with intrarater reliabilities of 0.936, 0.975, and 0.945 for the thoracic, lumbar, and thoracolumbar curves, respectively, and interrater reliabilities of 0.942 and 0.879 for the angular measures of the thoracic and thoracolumbar segments, respectively. The regression analyses revealed a high determination coefficient although limited to the adjusted linear model between the radiographic and photographic measures. It was found that with more severe scoliosis, the lateral curve measures obtained with the photogrammetry were for the thoracic and lumbar regions (R = 0.619 and 0.551). Conclusions: The photogrammetric measures were found to be reproducible in this study and could be used as Supplementary information to decrease the number of radiographs necessary for the monitoring of scoliosis. (J Manipulative Physiol Ther 2009;32:423-430)
Resumo:
We suggest a new notion of behaviour preserving transition refinement based on partial order semantics. This notion is called transition refinement. We introduced transition refinement for elementary (low-level) Petri Nets earlier. For modelling and verifying complex distributed algorithms, high-level (Algebraic) Petri nets are usually used. In this paper, we define transition refinement for Algebraic Petri Nets. This notion is more powerful than transition refinement for elementary Petri nets because it corresponds to the simultaneous refinement of several transitions in an elementary Petri net. Transition refinement is particularly suitable for refinement steps that increase the degree of distribution of an algorithm, e.g. when synchronous communication is replaced by asynchronous message passing. We study how to prove that a replacement of a transition is a transition refinement.
Resumo:
Axial vertebral rotation, an important parameter in the assessment of scoliosis may be identified on X-ray images. In line with the advances in the field of digital radiography, hospitals have been increasingly using this technique. The objective of the present study was to evaluate the reliability of computer-processed rotation measurements obtained from digital radiographs. A software program was therefore developed, which is able to digitally reproduce the methods of Perdriolle and Raimondi and to calculate semi-automatically the rotation degree of vertebra on digital radiographs. Three independent observers estimated vertebral rotation employing both the digital and the traditional manual methods. Compared to the traditional method, the digital assessment showed a 43% smaller error and a stronger correlation. In conclusion, the digital method seems to be reliable and enhance the accuracy and precision of vertebral rotation measurements.
Resumo:
Background: Pain and anxiety are a common problem in all recovery phases after a burn. The Burns Specific Pain Anxiety Scale (BSPAS) was proposed to assess anxiety in burn patients related to painful procedures. Objectives: To assess internal consistency, discriminative construct validity, dimensionality and convergent construct validity of the Brazilian-Portuguese version of the Burns Specific Pain Anxiety Scale. Design: In this cross-sectional study, the original version of the BSPAS, adapted into Brazilian Portuguese, was tested for internal consistency (Cronbach`s Alpha), discriminative validity (related to total body surface area burned and sex), dimensionality (through factor analysis), and convergent construct validity (applying the Visual Analogue Scale for pain and State-Anxiety-STAI) in a group of 91 adult burn patients. Results: The adapted version of the BSPAS displayed a moderate and positive correlation with pain assessments: immediately before baths and dressings (r = 0.32; p < 0.001), immediately after baths and dressings (r = 0.31; p < 0.001) and during the relaxation period (r= 0.31; p < 0.001) and with anxiety assessments (r = 0.34; p < 0.001). No statistically significant differences were observed when comparing the mean of the adapted version of the BSPAS scores with sex (p = 0.194) and total body surface area burned (p = 0.162) (discriminative validity). The principal components analysis applied to our sample seems to confirm anxiety as one single domain of the Brazilian-Portuguese version of the BSPAS. Cronbach`s Alpha showed high internal consistency of the adapted version of the scale (0.90). Conclusion: The Brazilian-Portuguese version of the BSPAS 9-items has shown statically acceptable levels of reliability and validity for pain-related anxiety evaluation in burn patients. This scale can be used to assess nursing interventions aimed at decreasing pain and anxiety related to the performance of painful procedures. (c) 2010 Elsevier Ltd. All rights reserved.
Resumo:
Background: This study was aimed at assessing the psychometric qualities of the abbreviated versions of the Alcohol Use Disorders Identification Test (AUDIT-3, AUDIT-4, AUDIT-C, AUDIT-PC, AUDIT-QF, FAST, and Five-Shot) and at comparing them to the 10-item AUDIT and the CAGE in 2 samples of Brazilian adults. Methods: The validity and internal consistency of the scales were assessed in a sample of 530 subjects attended at an emergency department and at a Psychosocial Care Center for Alcohol and Drugs. The Structured Clinical Interview for DSM-IV was used as the diagnostic comparative measure for the predictive validity assessment. The concurrent validity between the scales was analyzed by means of Pearson`s correlation coefficient. Results: The assessment of the predictive validity of the abbreviated versions showed high sensitivity (of 0.78 to 0.96) and specificity (of 0.74 to 0.94) indices, with areas under the curve as elevated as those of the AUDIT (0.89 and 0.92 to screen for abuse and 0.93 and 0.95 in the screening of dependence). The CAGE presented lower indices: 0.81 for abuse and 0.87 for dependence. The analysis of the internal consistency of the AUDIT and its versions exhibited Cronbach`s alpha coefficients between 0.83 and 0.94, while the coefficient for the CAGE was 0.78. Significant correlations were found between the 10-item AUDIT and its versions, ranging from 0.91 to 0.99. Again, the results for the CAGE were satisfactory (0.77), although inferior to the other instruments. Conclusions: The results obtained in this study confirm the validity of the abbreviated versions of the AUDIT for the screening of alcohol use disorders and show that their psychometric properties are as satisfactory as those of the 10-item AUDIT and the CAGE.
Resumo:
Introduction: Parkinson`s disease (PD) is a neurodegenerative disorder with prominent motor manifestations and many other non-motor symptoms that significantly decrease quality-of-life and are frequently under-recognized, for example depression. Objective: To study the validity of a Brazilian version of the Zung Self-rating Depression Scale (SDS) for the diagnosis of depression in patients with PD. Methods: We evaluated 78 consecutive non demented patients over the age of 40 with diagnosis of PD at a Movement Disorders Outpatient Clinic, who could read and understand questionnaires. They completed the SIDS and the Geriatric Depression Scale with 15 items (GDS-15). The diagnosis of depression was made after a structured clinical interview based on DSM-IV criteria for the diagnosis of major depression (SCID-CV). Results: The prevalence of major depression was 23.1%. Cronbach`s alpha was 0.73 and the area under the ROC curve was 0.93 for the SDS. The score index of 55 had a sensitivity of 88.9% and a specificity of 83.3% for the diagnosis of depression. The total scores of the SDS and GDS-15 were highly correlated (0.652, p < 0.0001) and correlated weakly with the scores of a motor scale. Discussion: The SIDS is a valid too] for screening depression in patients with PD since the specific SDS index of 55 is adopted. Two shortened versions could be used with good results. (C) 2009 Published by Elsevier Ltd.
Resumo:
The frontal assessment battery (FAB) is a bedside cognitive scale designed to measure executive functions. Huntington`s disease (HD) is a neurodegenerative disorder characterized by motor, behavioral, and cognitive dysfunction. The aim of this study was to check the validity of the FAB for the evaluation of cognitive impairment in patients with HD. Forty-one patients diagnosed with HD and 53 healthy controls matched by education, sex and age were evaluated with a validated Brazilian version of the UHDRS, the VFT, the SDMT, the SIT, the MMSE, and the FAB. The diagnosis of HD was made by DNA analysis. FAB scores were lower in patients than in the controls (p < 0.001) and had significant correlations with the VFT (r = 0.79; p < 0.05), the SDMT (r = 0.80; p < 0.05), the SIT (r = 0.72; p < 0.05), the MMSE (r = 0.83; p < 0.05), the FCS (r = 0.79; p < 0.05) and the motor section of the UHDRS (r = -0.80; p < 0.05). The FAB differentiated between HD patients in the initial and later stages of the disease. The one-year longitudinal evaluation revealed a global trend toward a worsening in the second score of the FAB. The results demonstrate that the FAB presents good internal consistency and also convergent and discriminative validity; therefore it is a useful scale to assess executive functions and to evaluate cognitive impairment in patients with HD.
Resumo:
PURPOSE. This study aimed to assess the discriminative validity of the Brazilian version of the Patient Health Questionnaire (PHQ-9) and of its reduced version (PHQ-2). DESIGN AND METHODS. The sample consisted of 177 women (60 cases of depression and 117 noncases). The SCID-IV was used as the gold standard. FINDINGS. For the PHQ-9, a cutoff score equal to or higher than 10 proved to be the most adequate for the screening of depression, whereas the best cutoff score for the PHQ-2 was found to lie between 3 and 4. PRACTICE IMPLICATIONS. The systematic use of these instruments in nursing and in the context of primary health care could favor the early detection of depression.
Resumo:
Objective: To evaluate the validity and applicability of the Mini International Neuropsychiatric Interview (MINI) used by family medicine residents in primary health care (PHC) in Brazil. Methods: Training for administrating the MINI was given as part of a broad psychiatry education program. Interviews were held with 120 PHC patients who were at least 15 years old. MINI was administered by 25 resident physicians, while the Structured Clinical Interview for Diagnosis (SCID) was administered by a psychiatrist blind to patients` results on the MINI, and the diagnoses on both interviews were compared. The resident physicians answered questions on the applicability of the MINI. Results: Concordance levels for any mental disorder, the broader current diagnostic categories and the most common specific diagnoses were analyzed. Kappa coefficients ranged between 0.65 and 0.85; sensitivity, between 0.75 and 0.92; specificity, between 0.90 and 0.99; positive predictive values (PPV), between 0.60 and 0.86; negative predictive values (NPV), between 0.92 and 0.99; and accuracy, between 0.88 and 0.98. The resident physicians considered MINI comprehensibility and clinical relevance satisfactory. Conclusions: These good psychometric results in a real-world setting may be related to a special training program, which is more frequent, intensive and diversified. In these conditions, the MINI is a useful tool for general practitioners. (c) 2008 Elsevier Inc. All rights reserved.
Resumo:
Objective: Clinical evaluation of the stomatognathic system is indispensable for the diagnosis of orofacial myofunctional disorders. In order to obtain a more precise diagnosis, the protocol of orofacial myofunctional evaluation with scores (OMES protocol) (Int. J. Pediatr. Otorhinolaryngol. 72 (2008) 367-375) was expanded in terms of number of items and scale amplitude. The proposal of this study is to describe the expanded OMES protocol (OMES-E) for the evaluation of children. Validity of the protocol, reliability of the examiners and agreement between them were analyzed, as also were the sensitivity, specificity and predictive values of the instrument. Methods: The sample consisted of videorecorded images of 50 children, 25 boys (mean age = 8.4 years, SD = 1.8) and 25 girls (mean age = 8.2 years, SD = 1.7) selected at random from 200 samples. Three speech therapists prepared for orofacial myofunctional evaluation participated as examiners (E). The OMES and OMES-E protocols were used for evaluation on different days. E1 evaluated all images, E2 analyzed children with recordings from 1 to 25 and E3 analyzed children with recordings from 26 to 50. The validity of OMES-E was analyzed by comparing the instrument to the OMES protocol using the Pearson correlation test complemented with the split-half reliability test (p < 0.05). The linear weighted Kappa coefficient of agreement (Kw`), the sensitivity, specificity and predictive values and the prevalence of OMD were calculated. Results: There was a statistically significant correlation between the OMES and OMES-E protocols (0.79 > r < 0.94, p < 0.01) and a significant test-retest correlation with the OMES-E (0.75 > r < 0.86, p < 0.01), with a reliability range of 0.86-0.93. The correlation and reliability coefficients between examiners were: E1 x E2 (r = 0.74, 0.84), E1 x E3 (r = 0.70, 0.83) (p < 0.01). Kw` coefficients with moderate and good strength predominated. The OMES-E protocol presented mean sensitivity = 0.91, specificity = 0.77, positive predictive value = 0.87 and negative predictive value = 0.85. The mean prevalence of OMD was 0.58. Conclusion: The OMES-E protocol is valid and reliable for orofacial myofunctional evaluation. (C) 2010 Elsevier Ireland Ltd. All rights reserved.