970 resultados para Generalized failure rate


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Balloon sinuplasty is a tool that is used to treat selected patients with paranasal sinus pathologies. No studies have investigated the aetiology of failed access to the frontal sinus. The aim of our study was to specify the intraoperative technical failure rate and to analyse the aetiology of the failed access to predict potential technical difficulties before surgery. We retrospectively analysed the charts of patients who underwent balloon sinuplasty from November 2007 to July 2010 at three different ENT-Centres. CT-analysis of the patients with failed access was performed. Of the 104 frontal sinuses, dilation of 12 (12%) sinuses failed. The anatomy of all failed cases revealed variations in the frontal recess (frontoethmoidal-cell, frontal-bulla-cell or agger-nasi-cell) or osteoneogenesis. In one patient, a lymphoma was overlooked during a balloon only procedure. The lymphoma was diagnosed 6 months later with a biopsy during functional endoscopic sinus surgery. In complex anatomical situations of the frontal recess, balloon sinuplasty may be challenging or impossible. In these situations, it is essential to have knowledge of classical functional endoscopic sinus surgery of the frontal recess area. The drawbacks of not including a histopathologic exam should be considered in balloon only procedures.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Microvascular surgery has become an important method for reconstructing surgical defects due to trauma, tumors or after burn. The most important factor for successful free flap transfer is a well-executed anastomosis. The time needed to perform the anastomosis and the failure rate are not negligible despite the high level of operator's experience. During the history, many alternatives were tried to help the microsurgeon and to reduce the complications. A Medline literature search was performed to find articles dealing with non-suture methods of microvascular anastomosis. Many historical books were also included. The non-suture techniques can be divided into four groups based on the used mechanism of sutures: double intubation including tubes and stents, intubation-eversion including simple rings, double eversion including staples and double rings, and wall adjustement with adhesives or laser. All these techniques were able to produce a faster and easier microvascular anastomosis. Nevertheless, disadvantages of the suturless techniques include toxicity, high cost, leakage or aneurysm formation. More refinement is needed before their widespread adoption. Thus, laser-assisted microvascular anastomosis using 1,9 μm diode laser appeared to be a safe and reliable help for the microsurgeon and may be further developed in the near future.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Lesions of the rotator cuff (RC) are among the most frequent tendon injuries. In spite of the developments in both open and arthroscopic surgery, RC repair still very often fails. In order to reduce the failure rate after surgery, several experimental in vitro and in vivo therapy methods have been developed for biological improvement of the reinsertion. This article provides an overview of the current evidence for augmentation of RC reconstruction with growth factors. Furthermore, potential future therapeutic approaches are discussed. We performed a comprehensive search of the PubMed database using various combinations of the keywords "tendon," "rotator cuff," "augmentation," "growth factor," "platelet-rich fibrin," and "platelet-rich plasma" for publications up to 2011. Given the linguistic capabilities of the research team, we considered publications in English, German, French, and Spanish. We excluded literature reviews, case reports, and letters to the editor.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Determination of chloride concentration in sweat is the current diagnostic gold standard for Cystic Fibrosis (CF). Nanoduct(R) is a new analyzing system measuring conductivity which requires only 3 microliters of sweat and gives results within 30 minutes. The aim of the study was to evaluate the applicability of this system in a clinical setting of three children's hospitals and borderline results were compared with sweat chloride concentration. Over 3 years, 1,041 subjects were tested and in 946 diagnostic results were obtained. In 95 children, Nanoduct(R) failed (9.1% failure rate), mainly due to failures in preterm babies and newborns. Assuming 59 mmol/L as an upper limit of normal conductivity, all our 46 CF patients were correctly diagnosed (sensitivity 100%, 95% CI: 93.1-100; negative predicted value 100% (95% CI: 99.6-100) and only 39 non CF's were false positive (39/900, 4.3%; specificity 95.7%, 95%CI: 94.2-96.9, positive predicted value 54.1% with a 95%CI: 43.4-65.0). Increasing the diagnostic limit to 80 mmol/L, the rate fell to 0.3% (3/900). CF patients had a median conductivity of 115 mmol/L; the non-CF a median of 37 mmol/L. In conclusion, the Nanoduct(R) test is a reliable diagnostic tool for CF diagnosis: It has a failure rate comparable to other sweat tests and can be used as a simple bedside test for fast and reliable exclusion, diagnosis or suspicion of CF. In cases with borderline conductivity (60-80 mmol/L) other additional methods (determination of chloride and genotyping) are indicated.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Total hip arthroplasty (THA) still carries a higher failure rate in patients with avascular necrosis of the femoral head (AVN) than in a similar patient population with THA for other reasons. This is particularly true for the acetabular component. One of the major factors accounting for this is the compromised acetabular bone quality with structural defects subsequent to collapsing of the femoral head in high-grade AVN. In this study we implanted an acetabular reinforcement ring with hook (ARRH), which had been used successfully for other indications with acetabular bone stock deficiency, in 32 consecutive THA's in 29 patients with AVN. Five patients died during the observation period of causes unrelated to the surgery, one patient was lost to follow-up and one patient could not be followed up due to chronic illness, leaving 25 hips (23 patients) with a minimum follow-up of ten years (mean: 11.8; range: 10-15). The mean Merle d'Aubigne score increased significantly from 7.7 preoperatively to 16.6 postoperatively (p < 0.001). One revision was performed for aseptic stem loosening. Of the unrevised hips, one acetabular component was classified as definitively loose. The cumulative 12-year survivorship for THA with ARRH in AVN was 95.2% (confidence interval: 86.1-100%) for both components, 100% for the cup and 95.2% for the stem (86.1-100%).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: To investigate predictors of continued HIV RNA viral load suppression in individuals switched to abacavir (ABC), lamivudine (3TC) and zidovudine (ZDV) after successful previous treatment with a protease inhibitor or non-nucleoside reverse transcriptase inhibitor-based combination antiretroviral therapy. DESIGN AND METHODS: An observational cohort study, which included individuals in the Swiss HIV Cohort Study switching to ABC/3TC/ZDV following successful suppression of viral load. The primary endpoint was time to treatment failure defined as the first of the following events: two consecutiveviral load measurements > 400 copies/ml under ABC/3TC/ZDV, one viral load measurement > 400 copies/ml and subsequent discontinuation of ABC/3TC/ZDV within 3 months, AIDS or death. RESULTS: We included 495 individuals; 47 experienced treatment failure in 1459 person-years of follow-up [rate = 3.22 events/100 person-years; 95% confidence interval (95% CI), 2.30-4.14]. Of all failures, 62% occurred in the first year after switching to ABC/3TC/ZDV. In a Cox regression analysis, treatment failure was independently associated with earlier exposure to nucleoside reverse transcriptase inhibitor (NRTI) mono or dual therapy [hazard ratio (HR), 8.02; 95% CI, 4.19-15.35) and low CD4 cell count at the time of the switch (HR, 0.66; 95% CI, 0.51-0.87 by +100 cells/microl up to 500 cells/microl). In patients without earlier exposure to mono or dual therapy, AIDS prior to switch to simplified maintenance therapy was an additional risk factor. CONCLUSIONS: The failure rate was low in patients with suppressed viral load and switch to ABC/3TC/ZDV treatment. Patients with earlier exposure to mono or dual NRTI therapy, low CD4 cell count at time of switch, or AIDS are at increased risk of treatment failure, limiting the use of ABC/3TC/ZDV in these patient groups.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Standard first-line combination antiretroviral treatment (cART) against human immunodeficiency virus 1 (HIV-1) contains either a nonnucleoside reverse transcriptase inhibitor (NNRTI) or a ritonavir-boosted protease inhibitor (PI/r). Differences between these regimen types in the extent of the emergence of drug resistance on virological failure and the implications for further treatment options have rarely been assessed. METHODS: We investigated virological outcomes in patients from the Swiss HIV Cohort Study initiating cART between January 1, 1999, and December 31, 2005, with an unboosted PI, a PI/r, or an NNRTI and compared genotypic drug resistance patterns among these groups at treatment failure. RESULTS: A total of 489 patients started cART with a PI, 518 with a PI/r, and 805 with an NNRTI. A total of 177 virological failures were observed (108 [22%] PI failures, 24 [5%] PI/r failures, and 45 [6%] NNRTI failures). The failure rate was highest in the PI group (10.3 per 100 person-years; 95% confidence interval [CI], 8.5-12.4). No difference was seen between patients taking a PI/r (2.7; 95% CI, 1.8-4.0) and those taking an NNRTI (2.4; 95% CI, 1.8-3.3). Genotypic test results were available for 142 (80%) of the patients with a virological treatment failure. Resistance mutations were found in 84% (95% CI, 75%-92%) of patients taking a PI, 30% (95% CI, 12%-54%) of patients taking a PI/r, and 66% (95% CI, 49%-80%) of patients taking an NNRTI (P < .001). Multidrug resistance occurred almost exclusively as resistance against lamivudine-emtricitabine and the group-specific third drug and was observed in 17% (95% CI, 9%-26%) of patients taking a PI, 10% (95% CI, 0.1%-32%) of patients taking a PI/r, and 50% (95% CI, 33%-67%) of patients taking an NNRTI (P < .001). CONCLUSIONS: Regimens that contained a PI/r or an NNRTI exhibited similar potency as first-line regimens. However, the use of a PI/r led to less resistance in case of virological failure, preserving more drug options for the future.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVES: The objectives of this systematic review were to assess the survival rate of implants placed in sites with transalveolar sinus floor elevation. MATERIAL AND METHODS: An electronic search was conducted to identify prospective and retrospective cohort studies on transalveolar sinus floor elevation, with a mean follow-up time of at least 1 year after functional loading. Failure and complication rates were analyzed using random-effects Poisson regression models to obtain summary estimates/ year proportions. RESULTS: The search provided 849 titles. Full-text analysis was performed for 176 articles, resulting in 19 studies that met the inclusion criteria. Meta-analysis of these studies indicated an estimated annual failure rate of 2.48% (95% confidence interval (95% CI): 1.37-4.49%) translating to an estimated survival rate of 92.8% (95% CI): 87.4-96.0%) for implants placed in transalveolarly augmented sinuses, after 3 years in function. Furthermore, subject-based analysis revealed an estimated annual failure of 3.71% (95% CI: 1.21-11.38%), translating to 10.5% (95% CI: 3.6-28.9%) of the subjects experiencing implant loss over 3 years. CONCLUSION: Survival rates of implants placed in transalveolar sinus floor augmentation sites are comparable to those in non-augmented sites. This technique is predictable with a low incidence of complications during and post-operatively.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVES: The objectives of this systematic review were to assess the survival rate of grafts and implants placed with sinus floor elevation. MATERIAL AND METHODS: An electronic search was conducted to identify studies on sinus floor elevation, with a mean follow-up time of at least 1 year after functional loading. RESULTS: The search provided 839 titles. Full-text analysis was performed for 175 articles resulting in 48 studies that met the inclusion criteria, reporting on 12,020 implants. Meta-analysis indicated an estimated annual failure rate of 3.48% [95% confidence interval (CI): 2.48%-4.88%] translating into a 3-year implant survival of 90.1% (95% CI: 86.4%-92.8%). However, when failure rates was analyzed on the subject level, the estimated annual failure was 6.04% (95% CI: 3.87%-9.43%) translating into 16.6% (95% CI: 10.9%-24.6%) of the subjects experiencing implant loss over 3 years. CONCLUSION: The insertion of dental implants in combination with maxillary sinus floor elevation is a predictable treatment method showing high implant survival rates and low incidences of surgical complications. The best results (98.3% implant survival after 3 years) were obtained using rough surface implants with membrane coverage of the lateral window.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: This retrospective study analyzed the pool of patients referred for treatment with dental implants over a 3-year period in a referral specialty clinic. Materials and Methods: All patients receiving dental implants between 2002 and 2004 in the Department of Oral Surgery and Stomatology, University of Bern, were included in this retrospective study. Patients were analyzed according to age, gender, indications for implant therapy, location of implants, and type and length of implants placed. A cumulative logistic regression analysis was performed to identify and analyze potential risk factors for complications or failures. Results: A total of 1,206 patients received 1,817 dental implants. The group comprised 573 men and 633 women with a mean age of 55.2 years. Almost 60% of patients were age 50 or older. The most frequent indication for implant therapy was single-tooth replacement in the maxilla (522 implants or 28.7%). A total of 726 implants (40%) were inserted in the esthetically demanding region of the anterior maxilla. For 939 implants (51.7%), additional bone-augmentation procedures were required. Of these, ridge augmentation with guided bone regeneration was performed more frequently than sinus grafting. Thirteen complications leading to early failures were recorded, resulting in an early failure rate of 0.7%. The regression analysis failed to identify statistically significant failure etiologies for the variables assessed. Conclusions: From this study it can be concluded that patients referred to a specialty clinic for implant placement were more likely to be partially edentulous and over 50 years old. Single-tooth replacement was the most frequent indication (> 50%). Similarly, additional bone augmentation was indicated in more than 50% of cases. Adhering to strict patient selection criteria and a standardized surgical protocol, an early failure rate of 0.7% was experienced in this study population

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Civil infrastructure provides essential services for the development of both society and economy. It is very important to manage systems efficiently to ensure sound performance. However, there are challenges in information extraction from available data, which also necessitates the establishment of methodologies and frameworks to assist stakeholders in the decision making process. This research proposes methodologies to evaluate systems performance by maximizing the use of available information, in an effort to build and maintain sustainable systems. Under the guidance of problem formulation from a holistic view proposed by Mukherjee and Muga, this research specifically investigates problem solving methods that measure and analyze metrics to support decision making. Failures are inevitable in system management. A methodology is developed to describe arrival pattern of failures in order to assist engineers in failure rescues and budget prioritization especially when funding is limited. It reveals that blockage arrivals are not totally random. Smaller meaningful subsets show good random behavior. Additional overtime failure rate is analyzed by applying existing reliability models and non-parametric approaches. A scheme is further proposed to depict rates over the lifetime of a given facility system. Further analysis of sub-data sets is also performed with the discussion of context reduction. Infrastructure condition is another important indicator of systems performance. The challenges in predicting facility condition are the transition probability estimates and model sensitivity analysis. Methods are proposed to estimate transition probabilities by investigating long term behavior of the model and the relationship between transition rates and probabilities. To integrate heterogeneities, model sensitivity is performed for the application of non-homogeneous Markov chains model. Scenarios are investigated by assuming transition probabilities follow a Weibull regressed function and fall within an interval estimate. For each scenario, multiple cases are simulated using a Monte Carlo simulation. Results show that variations on the outputs are sensitive to the probability regression. While for the interval estimate, outputs have similar variations to the inputs. Life cycle cost analysis and life cycle assessment of a sewer system are performed comparing three different pipe types, which are reinforced concrete pipe (RCP) and non-reinforced concrete pipe (NRCP), and vitrified clay pipe (VCP). Life cycle cost analysis is performed for material extraction, construction and rehabilitation phases. In the rehabilitation phase, Markov chains model is applied in the support of rehabilitation strategy. In the life cycle assessment, the Economic Input-Output Life Cycle Assessment (EIO-LCA) tools are used in estimating environmental emissions for all three phases. Emissions are then compared quantitatively among alternatives to support decision making.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: To assess the literature on accuracy and clinical performance of computer technology applications in surgical implant dentistry. MATERIALS AND METHODS: Electronic and manual literature searches were conducted to collect information about (1) the accuracy and (2) clinical performance of computer-assisted implant systems. Meta-regression analysis was performed for summarizing the accuracy studies. Failure/complication rates were analyzed using random-effects Poisson regression models to obtain summary estimates of 12-month proportions. RESULTS: Twenty-nine different image guidance systems were included. From 2,827 articles, 13 clinical and 19 accuracy studies were included in this systematic review. The meta-analysis of the accuracy (19 clinical and preclinical studies) revealed a total mean error of 0.74 mm (maximum of 4.5 mm) at the entry point in the bone and 0.85 mm at the apex (maximum of 7.1 mm). For the 5 included clinical studies (total of 506 implants) using computer-assisted implant dentistry, the mean failure rate was 3.36% (0% to 8.45%) after an observation period of at least 12 months. In 4.6% of the treated cases, intraoperative complications were reported; these included limited interocclusal distances to perform guided implant placement, limited primary implant stability, or need for additional grafting procedures. CONCLUSION: Differing levels and quantity of evidence were available for computer-assisted implant placement, revealing high implant survival rates after only 12 months of observation in different indications and a reasonable level of accuracy. However, future long-term clinical data are necessary to identify clinical indications and to justify additional radiation doses, effort, and costs associated with computer-assisted implant surgery.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: This systematic review sought to determine the long-term clinical survival rates of single-tooth restorations fabricated with computer-aided design/computer-assisted manufacture (CAD/CAM) technology, as well as the frequency of failures depending on the CAD/CAM system, the type of restoration, the selected material, and the luting agent. MATERIALS AND METHODS: An electronic search from 1985 to 2007 was performed using two databases: Medline/PubMed and Embase. Selected keywords and well-defined inclusion and exclusion criteria guided the search. All articles were first reviewed by title, then by abstract, and subsequently by a full text reading. Data were assessed and extracted by two independent examiners. The pooled results were statistically analyzed and the overall failure rate was calculated by assuming a Poisson-distributed number of events. In addition, reported failures were analyzed by CAD/CAM system, type of restoration, restorative material, and luting agent. RESULTS: From a total of 1,957 single-tooth restorations with a mean exposure time of 7.9 years and 170 failures, the failure rate was 1.75% per year, estimated per 100 restoration years (95% CI: 1.22% to 2.52%). The estimated total survival rate after 5 years of 91.6% (95% CI: 88.2% to 94.1%) was based on random-effects Poisson regression analysis. CONCLUSIONS: Long-term survival rates for CAD/CAM single-tooth Cerec 1, Cerec 2, and Celay restorations appear to be similar to conventional ones. No clinical studies or randomized clinical trials reporting on other CAD/CAM systems currently used in clinical practice and with follow-up reports of 3 or more years were found at the time of the search.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: The development of arsenical and diamidine resistance in Trypanosoma brucei is associated with loss of drug uptake by the P2 purine transporter as a result of alterations in the corresponding T. brucei adenosine transporter 1 gene (TbAT1). Previously, specific TbAT1 mutant type alleles linked to melarsoprol treatment failure were significantly more prevalent in T. b. gambiense from relapse patients at Omugo health centre in Arua district. Relapse rates of up to 30% prompted a shift from melarsoprol to eflornithine (alpha-difluoromethylornithine, DFMO) as first-line treatment at this centre. The aim of this study was to determine the status of TbAT1 in recent isolates collected from T. b. gambiense sleeping sickness patients from Arua and Moyo districts in Northwestern Uganda after this shift in first-line drug choice. METHODOLOGY AND RESULTS: Blood and cerebrospinal fluids of consenting patients were collected for DNA preparation and subsequent amplification. All of the 105 isolates from Omugo that we successfully analysed by PCR-RFLP possessed the TbAT1 wild type allele. In addition, PCR/RFLP analysis was performed for 74 samples from Moyo, where melarsoprol is still the first line drug; 61 samples displayed the wild genotype while six were mutant and seven had a mixed pattern of both mutant and wild-type TbAT1. The melarsoprol treatment failure rate at Moyo over the same period was nine out of 101 stage II cases that were followed up at least once. Five of the relapse cases harboured mutant TbAT1, one had the wild type, while no amplification was achieved from the remaining three samples. CONCLUSIONS/SIGNIFICANCE: The apparent disappearance of mutant alleles at Omugo may correlate with melarsoprol withdrawal as first-line treatment. Our results suggest that melarsoprol could successfully be reintroduced following a time lag subsequent to its replacement. A field-applicable test to predict melarsoprol treatment outcome and identify patients for whom the drug can still be beneficial is clearly required. This will facilitate cost-effective management of HAT in rural resource-poor settings, given that eflornithine has a much higher logistical requirement for its application.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

INTRODUCTION The objective of this trial was to compare the survival rates of mandibular lingual retainers bonded with either chemically cured or light-cured adhesive after orthodontic treatment. METHODS Patients having undergone orthodontic treatment at a private orthodontic office were randomly allocated to fixed retainers placed with chemically cured composite or light-cured composite. Eligibility criteria included no active caries, restorations, or fractures on the mandibular anterior teeth, and adequate oral hygiene. The main outcome was any type of first-time lingual retainer breakage; pattern of failure (adapted adhesive remnant index scores) was a secondary outcome. Randomization was accomplished with random permuted blocks of 20 patients with allocation concealed in sequentially numbered, opaque, sealed envelopes. Blinding was applicable for outcome assessment only. Patients were reviewed at 1, 3, and 6 months and then every 6 months after placement of the retainer until completion of the study. Data were analyzed using survival analysis including Cox regression; sensitivity analysis was carried out after data imputation for subjects lost to follow-up. RESULTS Two hundred twenty patients (median age, 16 years; interquartile range, 2; range, 12-47 years) were randomized in a 1:1 ratio to either chemical or light curing. Baseline characteristics were similar between groups, the median follow-up period was 2.19 years (range, 0.003-3.64 years), and 16 patients were lost to follow-up. At a minimum follow-up of 2 years, 47 of 110 (42.7%) and 55 of 110 (50.0%) retainers had some type of failure with chemically cured and light-cured adhesive, respectively (log-rank test, P = 0.35). Data were analyzed on an intention-to-treat basis, and the hazard ratio (HR) was 1.15 (95% confidence interval [CI], 0.88-1.70; P = 0.47). There was weak evidence that age is a significant predictor for lingual retainer failures (HR, 0.96; 95% CI, 0.93-1.00; P = 0.08). Adhesive remnant index scoring was possible for only 66 of the 102 (64.7%) failures and did not differ between composites (Fisher exact test, P = 0.16). No serious harm was observed other than gingivitis associated with plaque accumulation. CONCLUSIONS The results of this study indicated no evidence that survival of mandibular lingual retainers differs between chemically and light-cured adhesives. The overall failure rate was 46.4%; however, this included any type of failure, which may have exaggerated the overall failure rate.